{"id":"https://openalex.org/W4386766743","doi":"https://doi.org/10.1109/access.2023.3315737","title":"Research on TMR Current Transducer With Temperature Compensation Based on Reference Magnetic Field","display_name":"Research on TMR Current Transducer With Temperature Compensation Based on Reference Magnetic Field","publication_year":2023,"publication_date":"2023-01-01","ids":{"openalex":"https://openalex.org/W4386766743","doi":"https://doi.org/10.1109/access.2023.3315737"},"language":"en","primary_location":{"id":"doi:10.1109/access.2023.3315737","is_oa":true,"landing_page_url":"http://dx.doi.org/10.1109/access.2023.3315737","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/6514899/10252076.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://ieeexplore.ieee.org/ielx7/6287639/6514899/10252076.pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5107918638","display_name":"Jingru Li","orcid":null},"institutions":[{"id":"https://openalex.org/I74872605","display_name":"China Southern Power Grid (China)","ror":"https://ror.org/03hkh9419","country_code":"CN","type":"company","lineage":["https://openalex.org/I74872605"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Jingru Li","raw_affiliation_strings":["Metrology Center, Guangdong Power Grid Company Ltd., Guangzhou, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Metrology Center, Guangdong Power Grid Company Ltd., Guangzhou, China","institution_ids":["https://openalex.org/I74872605"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5032385053","display_name":"Feng Pan","orcid":"https://orcid.org/0000-0002-3788-7894"},"institutions":[{"id":"https://openalex.org/I74872605","display_name":"China Southern Power Grid (China)","ror":"https://ror.org/03hkh9419","country_code":"CN","type":"company","lineage":["https://openalex.org/I74872605"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Feng Pan","raw_affiliation_strings":["Metrology Center, Guangdong Power Grid Company Ltd., Guangzhou, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Metrology Center, Guangdong Power Grid Company Ltd., Guangzhou, China","institution_ids":["https://openalex.org/I74872605"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5052563125","display_name":"Jinli Li","orcid":"https://orcid.org/0000-0002-3556-9200"},"institutions":[{"id":"https://openalex.org/I74872605","display_name":"China Southern Power Grid (China)","ror":"https://ror.org/03hkh9419","country_code":"CN","type":"company","lineage":["https://openalex.org/I74872605"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jinli Li","raw_affiliation_strings":["Metrology Center, Guangdong Power Grid Company Ltd., Guangzhou, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Metrology Center, Guangdong Power Grid Company Ltd., Guangzhou, China","institution_ids":["https://openalex.org/I74872605"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5056960025","display_name":"Yilin Ji","orcid":"https://orcid.org/0000-0003-4072-9392"},"institutions":[{"id":"https://openalex.org/I74872605","display_name":"China Southern Power Grid (China)","ror":"https://ror.org/03hkh9419","country_code":"CN","type":"company","lineage":["https://openalex.org/I74872605"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yilin Ji","raw_affiliation_strings":["Metrology Center, Guangdong Power Grid Company Ltd., Guangzhou, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Metrology Center, Guangdong Power Grid Company Ltd., Guangzhou, China","institution_ids":["https://openalex.org/I74872605"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5081874087","display_name":"Hongtian Song","orcid":"https://orcid.org/0009-0007-0118-5982"},"institutions":[{"id":"https://openalex.org/I74872605","display_name":"China Southern Power Grid (China)","ror":"https://ror.org/03hkh9419","country_code":"CN","type":"company","lineage":["https://openalex.org/I74872605"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Hongtian Song","raw_affiliation_strings":["CSG Electric Power Research Institute, Guangzhou, China","Guangdong Provincial Key Laboratory of Intelligent Measurement and Advanced Metering of Power Grid, Guangzhou, China"],"raw_orcid":"https://orcid.org/0009-0007-0118-5982","affiliations":[{"raw_affiliation_string":"CSG Electric Power Research Institute, Guangzhou, China","institution_ids":["https://openalex.org/I74872605"]},{"raw_affiliation_string":"Guangdong Provincial Key Laboratory of Intelligent Measurement and Advanced Metering of Power Grid, Guangzhou, China","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5110637412","display_name":"Baoshuai Wang","orcid":null},"institutions":[{"id":"https://openalex.org/I74872605","display_name":"China Southern Power Grid (China)","ror":"https://ror.org/03hkh9419","country_code":"CN","type":"company","lineage":["https://openalex.org/I74872605"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Baoshuai Wang","raw_affiliation_strings":["CSG Electric Power Research Institute, Guangzhou, China","Guangdong Provincial Key Laboratory of Intelligent Measurement and Advanced Metering of Power Grid, Guangzhou, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"CSG Electric Power Research Institute, Guangzhou, China","institution_ids":["https://openalex.org/I74872605"]},{"raw_affiliation_string":"Guangdong Provincial Key Laboratory of Intelligent Measurement and Advanced Metering of Power Grid, Guangzhou, China","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":6,"corresponding_author_ids":["https://openalex.org/A5107918638"],"corresponding_institution_ids":["https://openalex.org/I74872605"],"apc_list":{"value":1850,"currency":"USD","value_usd":1850},"apc_paid":{"value":1850,"currency":"USD","value_usd":1850},"fwci":1.5193,"has_fulltext":true,"cited_by_count":12,"citation_normalized_percentile":{"value":0.82798133,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":97,"max":99},"biblio":{"volume":"11","issue":null,"first_page":"121828","last_page":"121834"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12692","display_name":"Magnetic Field Sensors Techniques","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12692","display_name":"Magnetic Field Sensors Techniques","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12169","display_name":"Non-Destructive Testing Techniques","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11325","display_name":"Inertial Sensor and Navigation","score":0.9923999905586243,"subfield":{"id":"https://openalex.org/subfields/2202","display_name":"Aerospace Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/compensation","display_name":"Compensation (psychology)","score":0.6625527739524841},{"id":"https://openalex.org/keywords/magnetic-field","display_name":"Magnetic field","score":0.6047295331954956},{"id":"https://openalex.org/keywords/transducer","display_name":"Transducer","score":0.5133344531059265},{"id":"https://openalex.org/keywords/temperature-measurement","display_name":"Temperature measurement","score":0.4835771918296814},{"id":"https://openalex.org/keywords/magnetoresistance","display_name":"Magnetoresistance","score":0.4728332459926605},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.44994890689849854},{"id":"https://openalex.org/keywords/current-sensor","display_name":"Current sensor","score":0.433660089969635},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.41862520575523376},{"id":"https://openalex.org/keywords/constant-current","display_name":"Constant current","score":0.41800352931022644},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.4084237813949585},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.39926642179489136},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.3555349111557007},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.24342599511146545},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.1991245448589325}],"concepts":[{"id":"https://openalex.org/C2780023022","wikidata":"https://www.wikidata.org/wiki/Q1338171","display_name":"Compensation (psychology)","level":2,"score":0.6625527739524841},{"id":"https://openalex.org/C115260700","wikidata":"https://www.wikidata.org/wiki/Q11408","display_name":"Magnetic field","level":2,"score":0.6047295331954956},{"id":"https://openalex.org/C56318395","wikidata":"https://www.wikidata.org/wiki/Q215928","display_name":"Transducer","level":2,"score":0.5133344531059265},{"id":"https://openalex.org/C72293138","wikidata":"https://www.wikidata.org/wiki/Q909741","display_name":"Temperature measurement","level":2,"score":0.4835771918296814},{"id":"https://openalex.org/C117958382","wikidata":"https://www.wikidata.org/wiki/Q58347","display_name":"Magnetoresistance","level":3,"score":0.4728332459926605},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.44994890689849854},{"id":"https://openalex.org/C55000061","wikidata":"https://www.wikidata.org/wiki/Q24894777","display_name":"Current sensor","level":3,"score":0.433660089969635},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.41862520575523376},{"id":"https://openalex.org/C53392680","wikidata":"https://www.wikidata.org/wiki/Q5163647","display_name":"Constant current","level":3,"score":0.41800352931022644},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4084237813949585},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.39926642179489136},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3555349111557007},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.24342599511146545},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.1991245448589325},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C11171543","wikidata":"https://www.wikidata.org/wiki/Q41630","display_name":"Psychoanalysis","level":1,"score":0.0},{"id":"https://openalex.org/C15744967","wikidata":"https://www.wikidata.org/wiki/Q9418","display_name":"Psychology","level":0,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/access.2023.3315737","is_oa":true,"landing_page_url":"http://dx.doi.org/10.1109/access.2023.3315737","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/6514899/10252076.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:cb71690424064144b3de32d6ea2f30ed","is_oa":true,"landing_page_url":"https://doaj.org/article/cb71690424064144b3de32d6ea2f30ed","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Access, Vol 11, Pp 121828-121834 (2023)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.1109/access.2023.3315737","is_oa":true,"landing_page_url":"http://dx.doi.org/10.1109/access.2023.3315737","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/6514899/10252076.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.9100000262260437,"display_name":"Affordable and clean energy"}],"awards":[{"id":"https://openalex.org/G7425354362","display_name":null,"funder_award_id":"GDKJXM20220200","funder_id":"https://openalex.org/F4320323192","funder_display_name":"China Southern Power Grid"}],"funders":[{"id":"https://openalex.org/F4320310509","display_name":"Electric Power Research Institute","ror":"https://ror.org/02dqztz06"},{"id":"https://openalex.org/F4320321125","display_name":"Beihang University","ror":"https://ror.org/00wk2mp56"},{"id":"https://openalex.org/F4320321883","display_name":"Huazhong University of Science and Technology","ror":"https://ror.org/00p991c53"},{"id":"https://openalex.org/F4320323192","display_name":"China Southern Power Grid","ror":"https://ror.org/03hkh9419"}],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4386766743.pdf","grobid_xml":"https://content.openalex.org/works/W4386766743.grobid-xml"},"referenced_works_count":19,"referenced_works":["https://openalex.org/W1944331705","https://openalex.org/W2038975402","https://openalex.org/W2119370132","https://openalex.org/W2130654330","https://openalex.org/W2255761902","https://openalex.org/W2564100306","https://openalex.org/W2590383972","https://openalex.org/W2809952567","https://openalex.org/W2899422891","https://openalex.org/W2906419301","https://openalex.org/W2908271955","https://openalex.org/W2929930813","https://openalex.org/W2943891580","https://openalex.org/W3000347616","https://openalex.org/W3011551823","https://openalex.org/W3097956140","https://openalex.org/W3133335242","https://openalex.org/W3205016666","https://openalex.org/W4313203524"],"related_works":["https://openalex.org/W3193331098","https://openalex.org/W992924612","https://openalex.org/W2344947612","https://openalex.org/W2376108318","https://openalex.org/W2352991256","https://openalex.org/W1246788070","https://openalex.org/W2012283803","https://openalex.org/W4384820447","https://openalex.org/W2376559530","https://openalex.org/W2002813990"],"abstract_inverted_index":{"TMR":[0,82,134,145,208],"magnetoresistance":[1],"sensors":[2,83,200],"have":[3],"advantages":[4],"such":[5],"as":[6],"small":[7],"size":[8],"and":[9,51,73,88,106,119,163,201,214],"low":[10],"power":[11],"consumption":[12],"in":[13,27],"the":[14,28,61,68,74,78,81,86,89,94,98,101,107,116,120,128,133,140,156,160,170,180,184],"field":[15,29,42,71,105,152,178],"of":[16,30,67,132,139,159,183,207],"current":[17,49,118,135,146],"measurement,":[18],"but":[19],"their":[20,25],"sensitivity":[21],"temperature":[22,35,129,141,164,171,181,192,199,209],"dependence":[23,182],"limits":[24],"application":[26],"electric":[31],"energy":[32],"metering.":[33],"A":[34],"compensation":[36,130,142,172,193],"method":[37,131,143,173,194],"based":[38,148,174],"on":[39,149,175],"reference":[40,62,69,150,176],"magnetic":[41,63,70,104,151,177],"was":[43,113],"proposed,":[44],"which":[45,80],"uses":[46],"a":[47,110],"constant":[48],"source":[50],"an":[52,56],"iron":[53],"core":[54],"with":[55],"air":[57,102],"gap":[58,103],"to":[59,188],"construct":[60],"field.":[64],"The":[65,137,166,190],"structures":[66],"channel":[72,76],"measurement":[75],"are":[77,85,93],"same,":[79,87],"used":[84],"signal":[90],"processing":[91],"circuits":[92],"same.":[95],"By":[96],"analyzing":[97],"relationship":[99],"between":[100,115],"primary":[108],"current,":[109],"mathematical":[111],"model":[112],"established":[114],"input":[117],"sensor":[121,185],"output":[122],"voltage,":[123],"thus":[124],"providing":[125],"support":[126],"for":[127,144],"sensor.":[136],"effectiveness":[138],"transducer":[147],"is":[153],"verified":[154],"by":[155],"test":[157],"data":[158],"nonlinear":[161],"characteristics":[162],"characteristics.":[165],"results":[167],"show":[168],"that":[169],"reduces":[179],"from":[186],"\u2212369ppm/\u00b0C":[187],"\u221249ppm/\u00b0C.":[189],"proposed":[191],"does":[195,202],"not":[196,203],"require":[197,204],"additional":[198],"prior":[205],"acquisition":[206],"characteristics,":[210],"making":[211],"it":[212],"specific":[213],"universal.":[215]},"counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2025,"cited_by_count":4},{"year":2024,"cited_by_count":6}],"updated_date":"2026-05-06T08:25:59.206177","created_date":"2025-10-10T00:00:00"}
