{"id":"https://openalex.org/W4382792339","doi":"https://doi.org/10.1109/access.2023.3276475","title":"Deep Learning Based Non-Intrusive Load Monitoring for a Three-Phase System","display_name":"Deep Learning Based Non-Intrusive Load Monitoring for a Three-Phase System","publication_year":2023,"publication_date":"2023-01-01","ids":{"openalex":"https://openalex.org/W4382792339","doi":"https://doi.org/10.1109/access.2023.3276475"},"language":"en","primary_location":{"id":"doi:10.1109/access.2023.3276475","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2023.3276475","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/10005208/10124772.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://ieeexplore.ieee.org/ielx7/6287639/10005208/10124772.pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5070344631","display_name":"B. Gowrienanthan","orcid":null},"institutions":[{"id":"https://openalex.org/I195740183","display_name":"University of Moratuwa","ror":"https://ror.org/0491f5305","country_code":"LK","type":"education","lineage":["https://openalex.org/I195740183"]}],"countries":["LK"],"is_corresponding":false,"raw_author_name":"B. Gowrienanthan","raw_affiliation_strings":["Department of Electrical Engineering, University of Moratuwa, Moratuwa, Sri Lanka"],"raw_orcid":"https://orcid.org/0009-0002-3563-2887","affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, University of Moratuwa, Moratuwa, Sri Lanka","institution_ids":["https://openalex.org/I195740183"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5085900023","display_name":"N. Kiruthihan","orcid":null},"institutions":[{"id":"https://openalex.org/I195740183","display_name":"University of Moratuwa","ror":"https://ror.org/0491f5305","country_code":"LK","type":"education","lineage":["https://openalex.org/I195740183"]}],"countries":["LK"],"is_corresponding":false,"raw_author_name":"N. Kiruthihan","raw_affiliation_strings":["Department of Electrical Engineering, University of Moratuwa, Moratuwa, Sri Lanka"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, University of Moratuwa, Moratuwa, Sri Lanka","institution_ids":["https://openalex.org/I195740183"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5112845523","display_name":"K. D. I. S. Rathnayake","orcid":null},"institutions":[{"id":"https://openalex.org/I195740183","display_name":"University of Moratuwa","ror":"https://ror.org/0491f5305","country_code":"LK","type":"education","lineage":["https://openalex.org/I195740183"]}],"countries":["LK"],"is_corresponding":false,"raw_author_name":"K. D. I. S. Rathnayake","raw_affiliation_strings":["Department of Electrical Engineering, University of Moratuwa, Moratuwa, Sri Lanka"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, University of Moratuwa, Moratuwa, Sri Lanka","institution_ids":["https://openalex.org/I195740183"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5092234340","display_name":"Sithamparanathan Kiruthikan","orcid":null},"institutions":[{"id":"https://openalex.org/I195740183","display_name":"University of Moratuwa","ror":"https://ror.org/0491f5305","country_code":"LK","type":"education","lineage":["https://openalex.org/I195740183"]}],"countries":["LK"],"is_corresponding":false,"raw_author_name":"S. Kiruthikan","raw_affiliation_strings":["Department of Electrical Engineering, University of Moratuwa, Moratuwa, Sri Lanka"],"raw_orcid":"https://orcid.org/0000-0003-3784-0698","affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, University of Moratuwa, Moratuwa, Sri Lanka","institution_ids":["https://openalex.org/I195740183"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5004216606","display_name":"Logeeshan Velmanickam","orcid":"https://orcid.org/0000-0003-3767-8280"},"institutions":[{"id":"https://openalex.org/I195740183","display_name":"University of Moratuwa","ror":"https://ror.org/0491f5305","country_code":"LK","type":"education","lineage":["https://openalex.org/I195740183"]}],"countries":["LK"],"is_corresponding":false,"raw_author_name":"V. Logeeshan","raw_affiliation_strings":["Department of Electrical Engineering, University of Moratuwa, Moratuwa, Sri Lanka"],"raw_orcid":"https://orcid.org/0000-0003-3767-8280","affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, University of Moratuwa, Moratuwa, Sri Lanka","institution_ids":["https://openalex.org/I195740183"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5084154943","display_name":"Sisil Kumarawadu","orcid":null},"institutions":[{"id":"https://openalex.org/I195740183","display_name":"University of Moratuwa","ror":"https://ror.org/0491f5305","country_code":"LK","type":"education","lineage":["https://openalex.org/I195740183"]}],"countries":["LK"],"is_corresponding":false,"raw_author_name":"S. Kumarawadu","raw_affiliation_strings":["Department of Electrical Engineering, University of Moratuwa, Moratuwa, Sri Lanka"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, University of Moratuwa, Moratuwa, Sri Lanka","institution_ids":["https://openalex.org/I195740183"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5060946009","display_name":"Chathura Wanigasekara","orcid":"https://orcid.org/0000-0003-4371-6108"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"C. Wanigasekara","raw_affiliation_strings":["Institute for the Protection of Maritime Infrastructures, German Aerospace Centre, Bremerhaven, Germany"],"raw_orcid":"https://orcid.org/0000-0003-4371-6108","affiliations":[{"raw_affiliation_string":"Institute for the Protection of Maritime Infrastructures, German Aerospace Centre, Bremerhaven, Germany","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":7,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":1850,"currency":"USD","value_usd":1850},"apc_paid":{"value":909,"currency":"EUR","value_usd":980},"fwci":2.2089,"has_fulltext":true,"cited_by_count":18,"citation_normalized_percentile":{"value":0.88017113,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":97,"max":100},"biblio":{"volume":"11","issue":null,"first_page":"49337","last_page":"49349"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11052","display_name":"Energy Load and Power Forecasting","score":0.9905999898910522,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9869999885559082,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/smart-meter","display_name":"Smart meter","score":0.8236962556838989},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7351808547973633},{"id":"https://openalex.org/keywords/key","display_name":"Key (lock)","score":0.5075176954269409},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.494947612285614},{"id":"https://openalex.org/keywords/deep-learning","display_name":"Deep learning","score":0.4657937288284302},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.4634760320186615},{"id":"https://openalex.org/keywords/electricity-meter","display_name":"Electricity meter","score":0.43464407324790955},{"id":"https://openalex.org/keywords/scale","display_name":"Scale (ratio)","score":0.4239039719104767},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.42034047842025757},{"id":"https://openalex.org/keywords/artificial-neural-network","display_name":"Artificial neural network","score":0.420169472694397},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.4031798839569092},{"id":"https://openalex.org/keywords/machine-learning","display_name":"Machine learning","score":0.32339054346084595},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.31177303194999695},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.18502044677734375},{"id":"https://openalex.org/keywords/computer-security","display_name":"Computer security","score":0.10651734471321106},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.09439456462860107}],"concepts":[{"id":"https://openalex.org/C2779510800","wikidata":"https://www.wikidata.org/wiki/Q1630602","display_name":"Smart meter","level":3,"score":0.8236962556838989},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7351808547973633},{"id":"https://openalex.org/C26517878","wikidata":"https://www.wikidata.org/wiki/Q228039","display_name":"Key (lock)","level":2,"score":0.5075176954269409},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.494947612285614},{"id":"https://openalex.org/C108583219","wikidata":"https://www.wikidata.org/wiki/Q197536","display_name":"Deep learning","level":2,"score":0.4657937288284302},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4634760320186615},{"id":"https://openalex.org/C67172668","wikidata":"https://www.wikidata.org/wiki/Q622756","display_name":"Electricity meter","level":3,"score":0.43464407324790955},{"id":"https://openalex.org/C2778755073","wikidata":"https://www.wikidata.org/wiki/Q10858537","display_name":"Scale (ratio)","level":2,"score":0.4239039719104767},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.42034047842025757},{"id":"https://openalex.org/C50644808","wikidata":"https://www.wikidata.org/wiki/Q192776","display_name":"Artificial neural network","level":2,"score":0.420169472694397},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.4031798839569092},{"id":"https://openalex.org/C119857082","wikidata":"https://www.wikidata.org/wiki/Q2539","display_name":"Machine learning","level":1,"score":0.32339054346084595},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.31177303194999695},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.18502044677734375},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.10651734471321106},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.09439456462860107},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1109/access.2023.3276475","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2023.3276475","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/10005208/10124772.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},{"id":"pmh:oai:elib.dlr.de:195329","is_oa":true,"landing_page_url":"https://doi.org/10.1109/ACCESS.2023.3276475>.","pdf_url":"https://elib.dlr.de/195329/1/Deep_Learning_Based_Non-Intrusive_Load_Monitoring_for_a_Three-Phase_System.pdf","source":{"id":"https://openalex.org/S4377196266","display_name":"elib (German Aerospace Center)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I2898391981","host_organization_name":"Deutsches Zentrum f\u00fcr Luft- und Raumfahrt e. V. (DLR)","host_organization_lineage":["https://openalex.org/I2898391981"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"PeerReviewed"},{"id":"pmh:oai:doaj.org/article:2aa453377bd24414b90db3cacf072d96","is_oa":true,"landing_page_url":"https://doaj.org/article/2aa453377bd24414b90db3cacf072d96","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Access, Vol 11, Pp 49337-49349 (2023)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.1109/access.2023.3276475","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2023.3276475","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/10005208/10124772.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.8899999856948853}],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4382792339.pdf","grobid_xml":"https://content.openalex.org/works/W4382792339.grobid-xml"},"referenced_works_count":22,"referenced_works":["https://openalex.org/W1479651931","https://openalex.org/W1996944908","https://openalex.org/W2123910460","https://openalex.org/W2152615204","https://openalex.org/W2167374930","https://openalex.org/W2519091744","https://openalex.org/W2566212894","https://openalex.org/W2793588003","https://openalex.org/W2906543346","https://openalex.org/W2963808366","https://openalex.org/W3099873379","https://openalex.org/W3127412393","https://openalex.org/W3149839747","https://openalex.org/W3165162317","https://openalex.org/W3179780422","https://openalex.org/W3186852856","https://openalex.org/W4205726048","https://openalex.org/W4285101211","https://openalex.org/W6649617573","https://openalex.org/W6731843568","https://openalex.org/W6757850440","https://openalex.org/W6793364036"],"related_works":["https://openalex.org/W3018909029","https://openalex.org/W3205631650","https://openalex.org/W2246071452","https://openalex.org/W2165970106","https://openalex.org/W2775355700","https://openalex.org/W1985785385","https://openalex.org/W1124398682","https://openalex.org/W4316660856","https://openalex.org/W2387071565","https://openalex.org/W1994682479"],"abstract_inverted_index":{"Non-Intrusive":[0],"Load":[1],"Monitoring":[2],"(NILM)":[3],"is":[4,27],"a":[5,22,86,103,135,154,189],"method":[6],"to":[7,53,61,107,120,126,140,211],"determine":[8],"the":[9,16,29,34,54,124,144,176,212],"power":[10,18,116],"consumption":[11,19],"of":[12,36,44,115,143,169,194],"individual":[13,51],"appliances":[14],"from":[15],"overall":[17],"measured":[20],"by":[21],"single":[23],"measurement":[24],"device,":[25],"which":[26,46,174],"usually":[28],"main":[30],"meter.":[31],"Increase":[32],"in":[33,147,207],"adoption":[35],"smart":[37],"meters":[38],"has":[39,91,123],"facilitated":[40],"large":[41],"scale":[42],"implementation":[43],"NILM,":[45],"can":[47],"provide":[48],"information":[49],"about":[50],"loads":[52,198],"utilities":[55],"and":[56,76,98,117,179,199,215],"consumers.":[57],"This":[58],"will":[59],"lead":[60],"significant":[62,113,205],"energy":[63],"savings":[64],"as":[65,67],"well":[66],"better":[68],"demand-side":[69],"management.":[70],"Researchers":[71],"have":[72,77,85,102,153],"proposed":[73],"several":[74,108],"methods":[75,214],"successfully":[78,94],"implemented":[79,95],"NILM":[80,90,119,149],"for":[81,96,150],"residential":[82],"sectors":[83],"that":[84,101,152,164,192],"single-phase":[87,200],"supply.":[88,156],"However,":[89],"not":[92,166],"been":[93],"industrial":[97],"commercial":[99],"buildings":[100,111,122,151],"three-phase":[104,155,190],"supply,":[105],"due":[106],"challenges.":[109],"These":[110],"consume":[112],"amount":[114],"implementing":[118,148],"these":[121],"potential":[125],"yield":[127],"substantial":[128],"benefits.":[129],"In":[130],"this":[131],"paper,":[132],"we":[133],"propose":[134],"novel":[136],"deep":[137],"learning-based":[138],"approach":[139,158],"address":[141],"some":[142],"key":[145],"challenges":[146],"Our":[157],"introduces":[159],"an":[160],"ensemble":[161],"learning":[162],"technique":[163],"does":[165],"require":[167],"training":[168],"multiple":[170],"neural":[171],"network":[172],"models,":[173],"reduces":[175],"computational":[177],"requirements":[178],"makes":[180],"it":[181],"economically":[182],"feasible.":[183],"The":[184,202],"model":[185],"was":[186],"tested":[187],"on":[188],"system":[191],"consists":[193],"both":[195],"three-":[196],"phase":[197],"loads.":[201],"results":[203],"show":[204],"improvement":[206],"load":[208],"disaggregation":[209],"compared":[210],"existing":[213],"indicate":[216],"its":[217],"applicability.":[218]},"counts_by_year":[{"year":2026,"cited_by_count":7},{"year":2025,"cited_by_count":4},{"year":2024,"cited_by_count":7}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
