{"id":"https://openalex.org/W4360899380","doi":"https://doi.org/10.1109/access.2023.3261554","title":"Body Posture Determination for Heart Failure Patients From Ankle Orientation Measurements","display_name":"Body Posture Determination for Heart Failure Patients From Ankle Orientation Measurements","publication_year":2023,"publication_date":"2023-01-01","ids":{"openalex":"https://openalex.org/W4360899380","doi":"https://doi.org/10.1109/access.2023.3261554"},"language":"en","primary_location":{"id":"doi:10.1109/access.2023.3261554","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2023.3261554","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/6514899/10080938.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://ieeexplore.ieee.org/ielx7/6287639/6514899/10080938.pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5057913126","display_name":"Santiago F. Scagliusi","orcid":"https://orcid.org/0000-0002-5634-5126"},"institutions":[{"id":"https://openalex.org/I4210104545","display_name":"Instituto de Microelectr\u00f3nica de Sevilla","ror":"https://ror.org/01mqtzm43","country_code":"ES","type":"facility","lineage":["https://openalex.org/I134820265","https://openalex.org/I4210104545","https://openalex.org/I4210147934","https://openalex.org/I79238269"]},{"id":"https://openalex.org/I79238269","display_name":"Universidad de Sevilla","ror":"https://ror.org/03yxnpp24","country_code":"ES","type":"education","lineage":["https://openalex.org/I79238269"]}],"countries":["ES"],"is_corresponding":true,"raw_author_name":"Santiago J. Fern\u00e1ndez Scagliusi","raw_affiliation_strings":["Instituto de Microelectr&#x00F3;nica de Sevilla (IMSE-CNM), University of Seville, Seville, Spain"],"raw_orcid":"https://orcid.org/0000-0002-5634-5126","affiliations":[{"raw_affiliation_string":"Instituto de Microelectr&#x00F3;nica de Sevilla (IMSE-CNM), University of Seville, Seville, Spain","institution_ids":["https://openalex.org/I4210104545","https://openalex.org/I79238269"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5043445221","display_name":"Pablo P\u00e9rez-Garc\u00eda","orcid":"https://orcid.org/0000-0003-2248-3544"},"institutions":[{"id":"https://openalex.org/I4210104545","display_name":"Instituto de Microelectr\u00f3nica de Sevilla","ror":"https://ror.org/01mqtzm43","country_code":"ES","type":"facility","lineage":["https://openalex.org/I134820265","https://openalex.org/I4210104545","https://openalex.org/I4210147934","https://openalex.org/I79238269"]},{"id":"https://openalex.org/I79238269","display_name":"Universidad de Sevilla","ror":"https://ror.org/03yxnpp24","country_code":"ES","type":"education","lineage":["https://openalex.org/I79238269"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Pablo P\u00e9rez-Garc\u00eda","raw_affiliation_strings":["Instituto de Microelectr&#x00F3;nica de Sevilla (IMSE-CNM), University of Seville, Seville, Spain"],"raw_orcid":"https://orcid.org/0000-0003-2248-3544","affiliations":[{"raw_affiliation_string":"Instituto de Microelectr&#x00F3;nica de Sevilla (IMSE-CNM), University of Seville, Seville, Spain","institution_ids":["https://openalex.org/I4210104545","https://openalex.org/I79238269"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5062805776","display_name":"Andreea M. Oprescu","orcid":null},"institutions":[{"id":"https://openalex.org/I79238269","display_name":"Universidad de Sevilla","ror":"https://ror.org/03yxnpp24","country_code":"ES","type":"education","lineage":["https://openalex.org/I79238269"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Andreea M. Oprescu","raw_affiliation_strings":["Departamento de Tecnolog&#x00ED;a Electr&#x00F3;nic, E.T.S. de Ingenier&#x00E1;a Inform&#x00E1;tica, University of Seville, Seville, Spain"],"raw_orcid":"https://orcid.org/0000-0003-3308-4688","affiliations":[{"raw_affiliation_string":"Departamento de Tecnolog&#x00ED;a Electr&#x00F3;nic, E.T.S. de Ingenier&#x00E1;a Inform&#x00E1;tica, University of Seville, Seville, Spain","institution_ids":["https://openalex.org/I79238269"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5074920502","display_name":"Daniel Mart\u00edn","orcid":"https://orcid.org/0000-0003-0590-7341"},"institutions":[{"id":"https://openalex.org/I4210104545","display_name":"Instituto de Microelectr\u00f3nica de Sevilla","ror":"https://ror.org/01mqtzm43","country_code":"ES","type":"facility","lineage":["https://openalex.org/I134820265","https://openalex.org/I4210104545","https://openalex.org/I4210147934","https://openalex.org/I79238269"]},{"id":"https://openalex.org/I79238269","display_name":"Universidad de Sevilla","ror":"https://ror.org/03yxnpp24","country_code":"ES","type":"education","lineage":["https://openalex.org/I79238269"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Daniel Mart\u00edn Fern\u00e1ndez","raw_affiliation_strings":["Instituto de Microelectr&#x00F3;nica de Sevilla (IMSE-CNM), University of Seville, Seville, Spain"],"raw_orcid":"https://orcid.org/0000-0003-0590-7341","affiliations":[{"raw_affiliation_string":"Instituto de Microelectr&#x00F3;nica de Sevilla (IMSE-CNM), University of Seville, Seville, Spain","institution_ids":["https://openalex.org/I4210104545","https://openalex.org/I79238269"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5005211287","display_name":"Alberto Olmo","orcid":"https://orcid.org/0000-0001-6388-4462"},"institutions":[{"id":"https://openalex.org/I4210104545","display_name":"Instituto de Microelectr\u00f3nica de Sevilla","ror":"https://ror.org/01mqtzm43","country_code":"ES","type":"facility","lineage":["https://openalex.org/I134820265","https://openalex.org/I4210104545","https://openalex.org/I4210147934","https://openalex.org/I79238269"]},{"id":"https://openalex.org/I79238269","display_name":"Universidad de Sevilla","ror":"https://ror.org/03yxnpp24","country_code":"ES","type":"education","lineage":["https://openalex.org/I79238269"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Alberto Olmo","raw_affiliation_strings":["Instituto de Microelectr&#x00F3;nica de Sevilla (IMSE-CNM), University of Seville, Seville, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Instituto de Microelectr&#x00F3;nica de Sevilla (IMSE-CNM), University of Seville, Seville, Spain","institution_ids":["https://openalex.org/I4210104545","https://openalex.org/I79238269"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5073688627","display_name":"Gloria Huertas","orcid":"https://orcid.org/0000-0001-5851-2576"},"institutions":[{"id":"https://openalex.org/I4210104545","display_name":"Instituto de Microelectr\u00f3nica de Sevilla","ror":"https://ror.org/01mqtzm43","country_code":"ES","type":"facility","lineage":["https://openalex.org/I134820265","https://openalex.org/I4210104545","https://openalex.org/I4210147934","https://openalex.org/I79238269"]},{"id":"https://openalex.org/I79238269","display_name":"Universidad de Sevilla","ror":"https://ror.org/03yxnpp24","country_code":"ES","type":"education","lineage":["https://openalex.org/I79238269"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Gloria Huertas S\u00e1nchez","raw_affiliation_strings":["Instituto de Microelectr&#x00F3;nica de Sevilla (IMSE-CNM), University of Seville, Seville, Spain"],"raw_orcid":"https://orcid.org/0000-0001-5851-2576","affiliations":[{"raw_affiliation_string":"Instituto de Microelectr&#x00F3;nica de Sevilla (IMSE-CNM), University of Seville, Seville, Spain","institution_ids":["https://openalex.org/I4210104545","https://openalex.org/I79238269"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5080209850","display_name":"Alberto Y\u00fafera","orcid":"https://orcid.org/0000-0002-1814-6089"},"institutions":[{"id":"https://openalex.org/I4210104545","display_name":"Instituto de Microelectr\u00f3nica de Sevilla","ror":"https://ror.org/01mqtzm43","country_code":"ES","type":"facility","lineage":["https://openalex.org/I134820265","https://openalex.org/I4210104545","https://openalex.org/I4210147934","https://openalex.org/I79238269"]},{"id":"https://openalex.org/I79238269","display_name":"Universidad de Sevilla","ror":"https://ror.org/03yxnpp24","country_code":"ES","type":"education","lineage":["https://openalex.org/I79238269"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Alberto Y\u00fafera","raw_affiliation_strings":["Instituto de Microelectr&#x00F3;nica de Sevilla (IMSE-CNM), University of Seville, Seville, Spain"],"raw_orcid":"https://orcid.org/0000-0002-1814-6089","affiliations":[{"raw_affiliation_string":"Instituto de Microelectr&#x00F3;nica de Sevilla (IMSE-CNM), University of Seville, Seville, Spain","institution_ids":["https://openalex.org/I4210104545","https://openalex.org/I79238269"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":7,"corresponding_author_ids":["https://openalex.org/A5057913126"],"corresponding_institution_ids":["https://openalex.org/I4210104545","https://openalex.org/I79238269"],"apc_list":{"value":1850,"currency":"USD","value_usd":1850},"apc_paid":{"value":1850,"currency":"USD","value_usd":1850},"fwci":0.0,"has_fulltext":true,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0257173,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"11","issue":null,"first_page":"48893","last_page":"48900"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9934999942779541,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9934999942779541,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11209","display_name":"Cardiovascular and exercise physiology","score":0.9933000206947327,"subfield":{"id":"https://openalex.org/subfields/2707","display_name":"Complementary and alternative medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11700","display_name":"Hemodynamic Monitoring and Therapy","score":0.9901999831199646,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/inertial-measurement-unit","display_name":"Inertial measurement unit","score":0.7069176435470581},{"id":"https://openalex.org/keywords/wearable-computer","display_name":"Wearable computer","score":0.6991408467292786},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6411685347557068},{"id":"https://openalex.org/keywords/remote-patient-monitoring","display_name":"Remote patient monitoring","score":0.574310839176178},{"id":"https://openalex.org/keywords/orientation","display_name":"Orientation (vector space)","score":0.5187068581581116},{"id":"https://openalex.org/keywords/power-consumption","display_name":"Power consumption","score":0.4935978651046753},{"id":"https://openalex.org/keywords/focus","display_name":"Focus (optics)","score":0.44674691557884216},{"id":"https://openalex.org/keywords/continuous-monitoring","display_name":"Continuous monitoring","score":0.4453474283218384},{"id":"https://openalex.org/keywords/units-of-measurement","display_name":"Units of measurement","score":0.4323711693286896},{"id":"https://openalex.org/keywords/match-moving","display_name":"Match moving","score":0.43162232637405396},{"id":"https://openalex.org/keywords/motion","display_name":"Motion (physics)","score":0.42821937799453735},{"id":"https://openalex.org/keywords/work","display_name":"Work (physics)","score":0.4210112392902374},{"id":"https://openalex.org/keywords/computer-vision","display_name":"Computer vision","score":0.3912789821624756},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.37991541624069214},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.3360971510410309},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.3125458061695099},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.18169230222702026},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.15240737795829773}],"concepts":[{"id":"https://openalex.org/C79061980","wikidata":"https://www.wikidata.org/wiki/Q941680","display_name":"Inertial measurement unit","level":2,"score":0.7069176435470581},{"id":"https://openalex.org/C150594956","wikidata":"https://www.wikidata.org/wiki/Q1334829","display_name":"Wearable computer","level":2,"score":0.6991408467292786},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6411685347557068},{"id":"https://openalex.org/C175079658","wikidata":"https://www.wikidata.org/wiki/Q7312165","display_name":"Remote patient monitoring","level":2,"score":0.574310839176178},{"id":"https://openalex.org/C16345878","wikidata":"https://www.wikidata.org/wiki/Q107472979","display_name":"Orientation (vector space)","level":2,"score":0.5187068581581116},{"id":"https://openalex.org/C2984118289","wikidata":"https://www.wikidata.org/wiki/Q29954","display_name":"Power consumption","level":3,"score":0.4935978651046753},{"id":"https://openalex.org/C192209626","wikidata":"https://www.wikidata.org/wiki/Q190909","display_name":"Focus (optics)","level":2,"score":0.44674691557884216},{"id":"https://openalex.org/C2776902269","wikidata":"https://www.wikidata.org/wiki/Q5165493","display_name":"Continuous monitoring","level":2,"score":0.4453474283218384},{"id":"https://openalex.org/C151233233","wikidata":"https://www.wikidata.org/wiki/Q47574","display_name":"Units of measurement","level":2,"score":0.4323711693286896},{"id":"https://openalex.org/C95020103","wikidata":"https://www.wikidata.org/wiki/Q1813492","display_name":"Match moving","level":3,"score":0.43162232637405396},{"id":"https://openalex.org/C104114177","wikidata":"https://www.wikidata.org/wiki/Q79782","display_name":"Motion (physics)","level":2,"score":0.42821937799453735},{"id":"https://openalex.org/C18762648","wikidata":"https://www.wikidata.org/wiki/Q42213","display_name":"Work (physics)","level":2,"score":0.4210112392902374},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.3912789821624756},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.37991541624069214},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3360971510410309},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.3125458061695099},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.18169230222702026},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.15240737795829773},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.0},{"id":"https://openalex.org/C126838900","wikidata":"https://www.wikidata.org/wiki/Q77604","display_name":"Radiology","level":1,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C21547014","wikidata":"https://www.wikidata.org/wiki/Q1423657","display_name":"Operations management","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":4,"locations":[{"id":"doi:10.1109/access.2023.3261554","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2023.3261554","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/6514899/10080938.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},{"id":"pmh:oai:digital.csic.es:10261/365327","is_oa":true,"landing_page_url":"http://hdl.handle.net/10261/365327","pdf_url":null,"source":{"id":"https://openalex.org/S4306401639","display_name":"DIGITAL.CSIC (Spanish National Research Council (CSIC))","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I134820265","host_organization_name":"Consejo Superior de Investigaciones Cient\u00edficas","host_organization_lineage":["https://openalex.org/I134820265"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/publishedVersion"},{"id":"pmh:oai:doaj.org/article:d31b91d81af24814aa7799660ed7f546","is_oa":true,"landing_page_url":"https://doaj.org/article/d31b91d81af24814aa7799660ed7f546","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Access, Vol 11, Pp 48893-48900 (2023)","raw_type":"article"},{"id":"pmh:oai:idus.us.es:11441/144484","is_oa":true,"landing_page_url":"https://idus.us.es/handle//11441/144484","pdf_url":null,"source":{"id":"https://openalex.org/S4306400333","display_name":"idUS (Universidad de Sevilla)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I79238269","host_organization_name":"Universidad de Sevilla","host_organization_lineage":["https://openalex.org/I79238269"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":{"id":"doi:10.1109/access.2023.3261554","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2023.3261554","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/6514899/10080938.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"sustainable_development_goals":[{"score":0.5199999809265137,"display_name":"Reduced inequalities","id":"https://metadata.un.org/sdg/10"},{"score":0.4399999976158142,"display_name":"Peace, Justice and strong institutions","id":"https://metadata.un.org/sdg/16"}],"awards":[{"id":"https://openalex.org/G2960035765","display_name":null,"funder_award_id":"DTS19/00134","funder_id":"https://openalex.org/F4320334923","funder_display_name":"Instituto de Salud Carlos III"},{"id":"https://openalex.org/G6704071293","display_name":null,"funder_award_id":"DTS19/00134-137","funder_id":"https://openalex.org/F4320315062","funder_display_name":"Ministerio de Ciencia, Innovaci\u00f3n y Universidades"},{"id":"https://openalex.org/G864454910","display_name":null,"funder_award_id":"AT 21_00010","funder_id":"https://openalex.org/F4320326754","funder_display_name":"Junta de Andaluc\u00eda"}],"funders":[{"id":"https://openalex.org/F4320310967","display_name":"Universidad de Sevilla","ror":"https://ror.org/03yxnpp24"},{"id":"https://openalex.org/F4320315062","display_name":"Ministerio de Ciencia, Innovaci\u00f3n y Universidades","ror":null},{"id":"https://openalex.org/F4320326754","display_name":"Junta de Andaluc\u00eda","ror":"https://ror.org/01jem9c82"},{"id":"https://openalex.org/F4320334923","display_name":"Instituto de Salud Carlos III","ror":"https://ror.org/00ca2c886"}],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4360899380.pdf","grobid_xml":"https://content.openalex.org/works/W4360899380.grobid-xml"},"referenced_works_count":23,"referenced_works":["https://openalex.org/W2030270245","https://openalex.org/W2095812275","https://openalex.org/W2227482793","https://openalex.org/W2272895042","https://openalex.org/W2294559741","https://openalex.org/W2295425605","https://openalex.org/W2397911846","https://openalex.org/W2427094903","https://openalex.org/W2737503982","https://openalex.org/W2782701828","https://openalex.org/W2791453970","https://openalex.org/W2811068931","https://openalex.org/W2950145193","https://openalex.org/W2952199022","https://openalex.org/W3007492756","https://openalex.org/W3118889537","https://openalex.org/W3133275659","https://openalex.org/W3139106521","https://openalex.org/W3163763055","https://openalex.org/W3176337006","https://openalex.org/W4307503086","https://openalex.org/W4311416639","https://openalex.org/W6845697277"],"related_works":["https://openalex.org/W1967422967","https://openalex.org/W2029881158","https://openalex.org/W3196140453","https://openalex.org/W4244061106","https://openalex.org/W3044242125","https://openalex.org/W2978426962","https://openalex.org/W2768468910","https://openalex.org/W2037990170","https://openalex.org/W2999148748","https://openalex.org/W2092597637"],"abstract_inverted_index":{"Heart-Failure":[0],"(HF)":[1],"is":[2,22,35,114,139],"among":[3],"the":[4,39,47,78,90,152,187,202],"leading":[5],"hospitalization":[6],"causes":[7],"in":[8,201],"modern":[9],"healthcare":[10],"systems.":[11],"In":[12,129],"this":[13,130],"paper,":[14],"a":[15,25,57,84,132,181],"method":[16,138],"for":[17,89,141,170,184],"performing":[18],"continuous":[19,144],"patient":[20,112],"monitoring":[21],"presented":[23,166],"with":[24,99],"focus":[26],"on":[27,111],"low":[28,142],"power":[29,143],"consumption.":[30],"A":[31,101],"prototype":[32],"wearable":[33],"device":[34],"being":[36],"developed":[37],"at":[38],"University":[40],"of":[41,74,77,87],"Sevilla":[42],"to":[43,108,195],"collect":[44],"measurements.":[45,205],"Among":[46],"sensing":[48],"components":[49],"there":[50],"are":[51,168],"two":[52],"major":[53,102],"blocks":[54],"formed":[55],"by":[56],"commercial":[58],"biological":[59],"impedance":[60,204],"analog":[61,203],"frontend":[62],"from":[63],"Analog":[64],"Devices":[65],"(AD5940)":[66],"and":[67,92,95,117,156,161,163,176,199],"an":[68],"Inertial":[69],"Motion":[70],"Unit":[71],"(IMU)":[72],"capable":[73],"estimating":[75],"attitude":[76],"device.":[79],"This":[80,146],"information":[81,88,110,190],"could":[82],"provide":[83,109],"tremendous":[85],"amount":[86],"physician":[91],"help":[93],"diagnose":[94],"remote":[96],"monitor":[97],"patients":[98],"HF.":[100],"factor":[103],"that":[104],"can":[105,178,191],"be":[106,192],"analyzed":[107],"status":[113],"activity":[115,136],"level":[116],"body":[118,133,174],"states;":[119],"time":[120],"spent":[121],"walking":[122],"or":[123,127],"standing,":[124],"laying":[125,153,159],"down":[126,154,160],"seated.":[128,164],"work,":[131],"tracking":[134],"/":[135],"estimation":[137],"proposed":[140],"monitoring.":[145],"study":[147],"reports":[148],"good":[149],"results":[150,167],"characterizing":[151],"position":[155,177],"discriminating":[157],"between":[158],"standing/walking":[162],"The":[165],"relevant":[169],"clinical":[171],"practice":[172],"since":[173],"motion":[175,189],"serve":[179],"as":[180],"health":[182],"marker":[183],"patients.":[185],"Additionally,":[186],"acquired":[188],"further":[193],"processed":[194],"better":[196],"understand":[197],"artifacts":[198],"variations":[200]},"counts_by_year":[],"updated_date":"2026-05-06T08:25:59.206177","created_date":"2023-03-26T00:00:00"}
