{"id":"https://openalex.org/W4226232614","doi":"https://doi.org/10.1109/access.2022.3157310","title":"Remote Synchronization of the Microgrid to the Utility Grid Without Access to Point of Common Coupling in the Presence of Disturbances","display_name":"Remote Synchronization of the Microgrid to the Utility Grid Without Access to Point of Common Coupling in the Presence of Disturbances","publication_year":2022,"publication_date":"2022-01-01","ids":{"openalex":"https://openalex.org/W4226232614","doi":"https://doi.org/10.1109/access.2022.3157310"},"language":"en","primary_location":{"id":"doi:10.1109/access.2022.3157310","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2022.3157310","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/9668973/09729744.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://ieeexplore.ieee.org/ielx7/6287639/9668973/09729744.pdf","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5048200646","display_name":"Mateusz Litwin","orcid":"https://orcid.org/0000-0002-0749-6665"},"institutions":[{"id":"https://openalex.org/I8264552","display_name":"Lublin University of Technology","ror":"https://ror.org/024zjzd49","country_code":"PL","type":"education","lineage":["https://openalex.org/I8264552"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Mateusz Litwin","raw_affiliation_strings":["Department of Electrical Drives and Machines, Lublin University of Technology, Lublin, Poland"],"raw_orcid":"https://orcid.org/0000-0002-0749-6665","affiliations":[{"raw_affiliation_string":"Department of Electrical Drives and Machines, Lublin University of Technology, Lublin, Poland","institution_ids":["https://openalex.org/I8264552"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5034151241","display_name":"Dariusz Zieli\u0144ski","orcid":"https://orcid.org/0000-0002-7382-6052"},"institutions":[{"id":"https://openalex.org/I108403487","display_name":"Warsaw University of Technology","ror":"https://ror.org/00y0xnp53","country_code":"PL","type":"education","lineage":["https://openalex.org/I108403487"]},{"id":"https://openalex.org/I8264552","display_name":"Lublin University of Technology","ror":"https://ror.org/024zjzd49","country_code":"PL","type":"education","lineage":["https://openalex.org/I8264552"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Dariusz Zielinski","raw_affiliation_strings":["Department of Electrical Drives and Machines, Lublin University of Technology, Lublin, Poland","Institute of Control and Industrial Electronics, Warsaw University of Technology, Warsaw, Poland"],"raw_orcid":"https://orcid.org/0000-0002-7382-6052","affiliations":[{"raw_affiliation_string":"Department of Electrical Drives and Machines, Lublin University of Technology, Lublin, Poland","institution_ids":["https://openalex.org/I8264552"]},{"raw_affiliation_string":"Institute of Control and Industrial Electronics, Warsaw University of Technology, Warsaw, Poland","institution_ids":["https://openalex.org/I108403487"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5027355729","display_name":"Sebastian Sty\u0144ski","orcid":"https://orcid.org/0000-0002-3786-6700"},"institutions":[{"id":"https://openalex.org/I108403487","display_name":"Warsaw University of Technology","ror":"https://ror.org/00y0xnp53","country_code":"PL","type":"education","lineage":["https://openalex.org/I108403487"]},{"id":"https://openalex.org/I8264552","display_name":"Lublin University of Technology","ror":"https://ror.org/024zjzd49","country_code":"PL","type":"education","lineage":["https://openalex.org/I8264552"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Sebastian Stynski","raw_affiliation_strings":["Department of Electrical Drives and Machines, Lublin University of Technology, Lublin, Poland","Institute of Control and Industrial Electronics, Warsaw University of Technology, Warsaw, Poland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Drives and Machines, Lublin University of Technology, Lublin, Poland","institution_ids":["https://openalex.org/I8264552"]},{"raw_affiliation_string":"Institute of Control and Industrial Electronics, Warsaw University of Technology, Warsaw, Poland","institution_ids":["https://openalex.org/I108403487"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":1850,"currency":"USD","value_usd":1850},"apc_paid":{"value":1850,"currency":"USD","value_usd":1850},"fwci":1.2136,"has_fulltext":true,"cited_by_count":11,"citation_normalized_percentile":{"value":0.77506178,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":98},"biblio":{"volume":"10","issue":null,"first_page":"27819","last_page":"27831"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13183","display_name":"Islanding Detection in Power Systems","score":0.9918000102043152,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9753000140190125,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/voltage-sag","display_name":"Voltage sag","score":0.8441553711891174},{"id":"https://openalex.org/keywords/harmonics","display_name":"Harmonics","score":0.694917619228363},{"id":"https://openalex.org/keywords/synchronization","display_name":"Synchronization (alternating current)","score":0.657069206237793},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.64436936378479},{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.6429068446159363},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.6059144735336304},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.6011385917663574},{"id":"https://openalex.org/keywords/phase-locked-loop","display_name":"Phase-locked loop","score":0.5413063168525696},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.48850905895233154},{"id":"https://openalex.org/keywords/voltage-source","display_name":"Voltage source","score":0.41624921560287476},{"id":"https://openalex.org/keywords/voltage-optimisation","display_name":"Voltage optimisation","score":0.41116976737976074},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.3591797351837158},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.2809757590293884},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.1936853528022766},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.14292055368423462},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.1313822865486145},{"id":"https://openalex.org/keywords/power-quality","display_name":"Power quality","score":0.11236333847045898},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.08409982919692993}],"concepts":[{"id":"https://openalex.org/C2781134633","wikidata":"https://www.wikidata.org/wiki/Q14945479","display_name":"Voltage sag","level":4,"score":0.8441553711891174},{"id":"https://openalex.org/C188414643","wikidata":"https://www.wikidata.org/wiki/Q3001183","display_name":"Harmonics","level":3,"score":0.694917619228363},{"id":"https://openalex.org/C2778562939","wikidata":"https://www.wikidata.org/wiki/Q1298791","display_name":"Synchronization (alternating current)","level":3,"score":0.657069206237793},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.64436936378479},{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.6429068446159363},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.6059144735336304},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.6011385917663574},{"id":"https://openalex.org/C12707504","wikidata":"https://www.wikidata.org/wiki/Q52637","display_name":"Phase-locked loop","level":3,"score":0.5413063168525696},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.48850905895233154},{"id":"https://openalex.org/C144655898","wikidata":"https://www.wikidata.org/wiki/Q1161128","display_name":"Voltage source","level":3,"score":0.41624921560287476},{"id":"https://openalex.org/C46529443","wikidata":"https://www.wikidata.org/wiki/Q7940750","display_name":"Voltage optimisation","level":4,"score":0.41116976737976074},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3591797351837158},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.2809757590293884},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.1936853528022766},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.14292055368423462},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.1313822865486145},{"id":"https://openalex.org/C2779665505","wikidata":"https://www.wikidata.org/wiki/Q1780079","display_name":"Power quality","level":3,"score":0.11236333847045898},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.08409982919692993},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C127162648","wikidata":"https://www.wikidata.org/wiki/Q16858953","display_name":"Channel (broadcasting)","level":2,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C134652429","wikidata":"https://www.wikidata.org/wiki/Q1052698","display_name":"Jitter","level":2,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/access.2022.3157310","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2022.3157310","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/9668973/09729744.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:85d438a2f4764e6b9ef1c4f5a6476c56","is_oa":false,"landing_page_url":"https://doaj.org/article/85d438a2f4764e6b9ef1c4f5a6476c56","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Access, Vol 10, Pp 27819-27831 (2022)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.1109/access.2022.3157310","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2022.3157310","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/9668973/09729744.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"sustainable_development_goals":[{"score":0.8299999833106995,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4226232614.pdf","grobid_xml":"https://content.openalex.org/works/W4226232614.grobid-xml"},"referenced_works_count":33,"referenced_works":["https://openalex.org/W1770637019","https://openalex.org/W1980236788","https://openalex.org/W1999146686","https://openalex.org/W2003177701","https://openalex.org/W2021038145","https://openalex.org/W2027007802","https://openalex.org/W2032919163","https://openalex.org/W2041178557","https://openalex.org/W2049155710","https://openalex.org/W2055851902","https://openalex.org/W2057474934","https://openalex.org/W2057975886","https://openalex.org/W2123102226","https://openalex.org/W2130055347","https://openalex.org/W2150026168","https://openalex.org/W2165822319","https://openalex.org/W2166642351","https://openalex.org/W2170063465","https://openalex.org/W2337249968","https://openalex.org/W2479454431","https://openalex.org/W2517305838","https://openalex.org/W2649842847","https://openalex.org/W2669559693","https://openalex.org/W2793798581","https://openalex.org/W2803856212","https://openalex.org/W2901814362","https://openalex.org/W2903775112","https://openalex.org/W2906633606","https://openalex.org/W2918750212","https://openalex.org/W3107686147","https://openalex.org/W3124523326","https://openalex.org/W6789073279","https://openalex.org/W6814551054"],"related_works":["https://openalex.org/W2992869285","https://openalex.org/W794857952","https://openalex.org/W2902929055","https://openalex.org/W2774383274","https://openalex.org/W2138391653","https://openalex.org/W2558892172","https://openalex.org/W4223577069","https://openalex.org/W2363577217","https://openalex.org/W2781302742","https://openalex.org/W1965278685"],"abstract_inverted_index":{"The":[0,19,95,125,143],"article":[1],"presents":[2],"the":[3,10,14,30,33,55,88,99,105,111,114,118,123,147,151,162],"method":[4],"of":[5,16,32,40,47,51,57,80,82,101,113,117,128,149,164],"remote":[6,107,153],"micro-grid":[7,157],"synchronization":[8,89,108],"with":[9,71],"utility":[11,166],"grid":[12,58,62,83,129,167],"in":[13,38,78,156,161],"presence":[15,56,79,163],"voltage":[17,35,41,59,63,102,130,141,168],"disturbances.":[18,169],"proposed":[20,106,152],"algorithm":[21,90,155],"and":[22,44,68,91,110,139],"control":[23],"devices":[24],"synchronize":[25],"different":[26],"power":[27,120,158],"systems":[28],"on":[29,87,98,104,122],"basis":[31],"instantaneous":[34,61],"phase":[36,64,140],"angle":[37,65],"spite":[39],"quality":[42],"problems":[43],"without":[45],"need":[46],"access":[48],"to":[49],"point":[50],"common":[52],"coupling.":[53],"In":[54],"disturbances,":[60],"is":[66,76],"estimated":[67],"transmitted":[69],"remotely":[70],"a":[72],"certain":[73],"accuracy,":[74],"which":[75],"varies":[77],"disturbances":[81,103,131],"voltages":[84],"or":[85],"depends":[86],"data":[92],"transmission":[93],"rate.":[94],"paper":[96],"focuses":[97],"influence":[100],"strategy":[109],"shape":[112],"output":[115],"current":[116],"synchronized":[119],"converter":[121,159],"micro-grid.":[124],"four":[126],"types":[127],"are":[132],"presented:":[133],"harmonics,":[134],"one-phase":[135],"sag,":[136,138],"two-phase":[137],"jump.":[142],"final":[144],"conclusions":[145],"present":[146],"possibility":[148],"using":[150],"synchronizations":[154],"applications":[160],"typical":[165]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":3},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":3},{"year":2022,"cited_by_count":2}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
