{"id":"https://openalex.org/W4205096573","doi":"https://doi.org/10.1109/access.2021.3138522","title":"Development of Prototype to Measure Intraocular Pressure of Eye Along With Gonioscopy","display_name":"Development of Prototype to Measure Intraocular Pressure of Eye Along With Gonioscopy","publication_year":2021,"publication_date":"2021-12-24","ids":{"openalex":"https://openalex.org/W4205096573","doi":"https://doi.org/10.1109/access.2021.3138522"},"language":"en","primary_location":{"id":"doi:10.1109/access.2021.3138522","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2021.3138522","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/6514899/09663199.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://ieeexplore.ieee.org/ielx7/6287639/6514899/09663199.pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5112421485","display_name":"R. B. Bharathi","orcid":"https://orcid.org/0009-0005-1131-4800"},"institutions":[{"id":"https://openalex.org/I164861460","display_name":"Manipal Academy of Higher Education","ror":"https://ror.org/02xzytt36","country_code":"IN","type":"education","lineage":["https://openalex.org/I164861460"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"R. B. Bharathi","raw_affiliation_strings":["Department of Electrical & Electronics Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical & Electronics Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, India","institution_ids":["https://openalex.org/I164861460"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5037655712","display_name":"Ramesh S. Ve","orcid":"https://orcid.org/0000-0002-7592-9151"},"institutions":[{"id":"https://openalex.org/I164861460","display_name":"Manipal Academy of Higher Education","ror":"https://ror.org/02xzytt36","country_code":"IN","type":"education","lineage":["https://openalex.org/I164861460"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Ramesh S. Ve","raw_affiliation_strings":["Department of Optometry, Manipal College of Health Professions, Manipal Academy of Higher Education, India"],"raw_orcid":"https://orcid.org/0000-0002-7592-9151","affiliations":[{"raw_affiliation_string":"Department of Optometry, Manipal College of Health Professions, Manipal Academy of Higher Education, India","institution_ids":["https://openalex.org/I164861460"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5051565689","display_name":"K. Gopalakrishna Prabhu","orcid":"https://orcid.org/0000-0003-1355-4208"},"institutions":[{"id":"https://openalex.org/I73779912","display_name":"Manipal University Jaipur","ror":"https://ror.org/040h76494","country_code":null,"type":"education","lineage":["https://openalex.org/I73779912"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Gopalakrishna Prabhu","raw_affiliation_strings":["Department of Electronics and Communication Engineering, Manipal University Jaipur, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electronics and Communication Engineering, Manipal University Jaipur, India","institution_ids":["https://openalex.org/I73779912"]}]},{"author_position":"last","author":{"id":null,"display_name":"Meenatchi Sundaram Swaminathan","orcid":"https://orcid.org/0000-0001-7288-4464"},"institutions":[{"id":"https://openalex.org/I164861460","display_name":"Manipal Academy of Higher Education","ror":"https://ror.org/02xzytt36","country_code":"IN","type":"education","lineage":["https://openalex.org/I164861460"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Meenatchi Sundaram Swaminathan","raw_affiliation_strings":["Department of Instrumentation and Control Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, India"],"raw_orcid":"https://orcid.org/0000-0001-7288-4464","affiliations":[{"raw_affiliation_string":"Department of Instrumentation and Control Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, India","institution_ids":["https://openalex.org/I164861460"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":1850,"currency":"USD","value_usd":1850},"apc_paid":{"value":1850,"currency":"USD","value_usd":1850},"fwci":0.3707,"has_fulltext":true,"cited_by_count":2,"citation_normalized_percentile":{"value":0.61657033,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":"10","issue":null,"first_page":"7245","last_page":"7253"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10250","display_name":"Glaucoma and retinal disorders","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2731","display_name":"Ophthalmology"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T10250","display_name":"Glaucoma and retinal disorders","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2731","display_name":"Ophthalmology"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10563","display_name":"Corneal surgery and disorders","score":0.9937999844551086,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11438","display_name":"Retinal Imaging and Analysis","score":0.9908000230789185,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/glaucoma","display_name":"Glaucoma","score":0.8025344014167786},{"id":"https://openalex.org/keywords/gonioscopy","display_name":"Gonioscopy","score":0.8017014265060425},{"id":"https://openalex.org/keywords/intraocular-pressure","display_name":"Intraocular pressure","score":0.6375587582588196},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5221369862556458},{"id":"https://openalex.org/keywords/optometry","display_name":"Optometry","score":0.4339810013771057},{"id":"https://openalex.org/keywords/measure","display_name":"Measure (data warehouse)","score":0.41171616315841675},{"id":"https://openalex.org/keywords/ophthalmology","display_name":"Ophthalmology","score":0.37653157114982605},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.2987704277038574},{"id":"https://openalex.org/keywords/data-mining","display_name":"Data mining","score":0.06636136770248413}],"concepts":[{"id":"https://openalex.org/C2778527774","wikidata":"https://www.wikidata.org/wiki/Q159701","display_name":"Glaucoma","level":2,"score":0.8025344014167786},{"id":"https://openalex.org/C2780892088","wikidata":"https://www.wikidata.org/wiki/Q1414474","display_name":"Gonioscopy","level":3,"score":0.8017014265060425},{"id":"https://openalex.org/C2781092963","wikidata":"https://www.wikidata.org/wiki/Q650050","display_name":"Intraocular pressure","level":2,"score":0.6375587582588196},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5221369862556458},{"id":"https://openalex.org/C119767625","wikidata":"https://www.wikidata.org/wiki/Q618211","display_name":"Optometry","level":1,"score":0.4339810013771057},{"id":"https://openalex.org/C2780009758","wikidata":"https://www.wikidata.org/wiki/Q6804172","display_name":"Measure (data warehouse)","level":2,"score":0.41171616315841675},{"id":"https://openalex.org/C118487528","wikidata":"https://www.wikidata.org/wiki/Q161437","display_name":"Ophthalmology","level":1,"score":0.37653157114982605},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.2987704277038574},{"id":"https://openalex.org/C124101348","wikidata":"https://www.wikidata.org/wiki/Q172491","display_name":"Data mining","level":1,"score":0.06636136770248413}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/access.2021.3138522","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2021.3138522","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/6514899/09663199.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:43ddd50064dd4203a6989d44f81b5167","is_oa":true,"landing_page_url":"https://doaj.org/article/43ddd50064dd4203a6989d44f81b5167","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Access, Vol 10, Pp 7245-7253 (2022)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.1109/access.2021.3138522","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2021.3138522","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/6514899/09663199.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4205096573.pdf","grobid_xml":"https://content.openalex.org/works/W4205096573.grobid-xml"},"referenced_works_count":22,"referenced_works":["https://openalex.org/W12502688","https://openalex.org/W1562714951","https://openalex.org/W1856328802","https://openalex.org/W1970676909","https://openalex.org/W1978300670","https://openalex.org/W1979200335","https://openalex.org/W2011370705","https://openalex.org/W2085782484","https://openalex.org/W2114371521","https://openalex.org/W2157590007","https://openalex.org/W2160605010","https://openalex.org/W2761603723","https://openalex.org/W2769650076","https://openalex.org/W2782940690","https://openalex.org/W2808526637","https://openalex.org/W2995331514","https://openalex.org/W2999880982","https://openalex.org/W4235044801","https://openalex.org/W6600512674","https://openalex.org/W6633808326","https://openalex.org/W6773173087","https://openalex.org/W6844837464"],"related_works":["https://openalex.org/W2390881717","https://openalex.org/W4283364145","https://openalex.org/W23766661","https://openalex.org/W2412221744","https://openalex.org/W2090868427","https://openalex.org/W74963343","https://openalex.org/W427440713","https://openalex.org/W1996537036","https://openalex.org/W2048665593","https://openalex.org/W2410106096"],"abstract_inverted_index":{"Tonometry,":[0],"a":[1,49,69,190],"procedure":[2],"of":[3,97,135,172,179,181],"glaucoma":[4,42],"investigation":[5],"is":[6,65,78,87,104,107,123,144],"carried":[7],"out":[8],"effectively":[9],"in":[10,109,170],"all":[11],"eye":[12,99,137,174],"care":[13],"clinics.":[14],"The":[15,76,90,163],"other":[16],"testing":[17,43],"method":[18],"namely":[19],"gonioscopy":[20],"requires":[21],"professional":[22],"expertise":[23],"and":[24,53,58,83,100,106,184],"experience":[25],"due":[26],"to":[27,61,125,147,154,160],"which":[28,129],"optometrists/ophthalmologists":[29],"avoid":[30],"this":[31],"test.":[32],"Hence":[33],"the":[34,62,73,84,93,98,101,113,118,126,132,136,139,148,152,156,168,173,177,182,185],"proposed":[35],"technology":[36],"would":[37],"let":[38],"these":[39],"two":[40],"important":[41],"procedures":[44],"be":[45],"performed":[46,79],"simultaneously":[47],"with":[48],"common":[50],"instrument":[51],"\u201cTonogoniometry\u201d":[52],"making":[54],"detection":[55],"easier,":[56],"time-saving,":[57],"lowering":[59],"uneasiness":[60],"patient.":[63],"Tonometry":[64],"implemented":[66,108],"by":[67,117],"embedding":[68],"vibration":[70,180],"sensor":[71,102,114,183,186],"on":[72,80,138],"3-mirror":[74],"goniolens.":[75],"experiment":[77],"goat":[81],"eyes":[82],"data":[85,120],"collected":[86],"statistically":[88],"analyzed.":[89],"relation":[91],"between":[92],"Intraocular":[94],"pressure":[95],"(IOP)":[96],"output":[103,115,187],"derived":[105],"LabVIEW.":[110],"During":[111],"tonometry,":[112],"captured":[116],"NI":[119],"acquisition":[121],"card":[122],"fed":[124],"LabVIEW":[127],"platform":[128],"will":[130,175,188],"display":[131],"evaluated":[133],"IOP":[134,171],"computer":[140],"screen.":[141],"Meanwhile,":[142],"there":[143],"no":[145],"obstruction":[146],"light":[149],"path":[150],"through":[151],"goniolens":[153],"visualize":[155],"anterior":[157],"chamber":[158],"angle":[159],"perform":[161],"gonioscopy.":[162],"experimental":[164],"results":[165],"epitomized":[166],"that":[167],"rise":[169],"increase":[176],"intensity":[178],"have":[189],"higher":[191],"magnitude.":[192]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
