{"id":"https://openalex.org/W3216648065","doi":"https://doi.org/10.1109/access.2021.3130642","title":"Fixed-Time Distributed Secondary Control for Islanded Microgrids With Mobile Emergency Resources Over Switching Communication Topologies","display_name":"Fixed-Time Distributed Secondary Control for Islanded Microgrids With Mobile Emergency Resources Over Switching Communication Topologies","publication_year":2021,"publication_date":"2021-01-01","ids":{"openalex":"https://openalex.org/W3216648065","doi":"https://doi.org/10.1109/access.2021.3130642","mag":"3216648065"},"language":"en","primary_location":{"id":"doi:10.1109/access.2021.3130642","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2021.3130642","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/6514899/09627170.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://ieeexplore.ieee.org/ielx7/6287639/6514899/09627170.pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101807659","display_name":"Zhenjie Wu","orcid":"https://orcid.org/0009-0001-5477-8307"},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Zhenjie Wu","raw_affiliation_strings":["State Grid Hangzhou Power Supply Company, Hangzhou 310020, China"],"affiliations":[{"raw_affiliation_string":"State Grid Hangzhou Power Supply Company, Hangzhou 310020, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5089398924","display_name":"Tianen Huang","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Tianen Huang","raw_affiliation_strings":["State Grid Hangzhou Power Supply Company, Hangzhou 310020, China"],"affiliations":[{"raw_affiliation_string":"State Grid Hangzhou Power Supply Company, Hangzhou 310020, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5082617820","display_name":"Yajun Mo","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Yajun Mo","raw_affiliation_strings":["State Grid Hangzhou Power Supply Company, Hangzhou 310020, China"],"affiliations":[{"raw_affiliation_string":"State Grid Hangzhou Power Supply Company, Hangzhou 310020, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100626980","display_name":"Xiang Li","orcid":"https://orcid.org/0000-0002-3017-7048"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Xiang Li","raw_affiliation_strings":["State Grid Hangzhou Power Supply Company, Hangzhou 310020, China"],"affiliations":[{"raw_affiliation_string":"State Grid Hangzhou Power Supply Company, Hangzhou 310020, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5046431337","display_name":"Wang Yuan-tao","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Yuantao Wang","raw_affiliation_strings":["State Grid Hangzhou Power Supply Company, Hangzhou 310020, China"],"affiliations":[{"raw_affiliation_string":"State Grid Hangzhou Power Supply Company, Hangzhou 310020, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5039176528","display_name":"Jian Tang","orcid":"https://orcid.org/0000-0003-4418-0114"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Jian Tang","raw_affiliation_strings":["State Grid Hangzhou Power Supply Company, Hangzhou 310020, China"],"affiliations":[{"raw_affiliation_string":"State Grid Hangzhou Power Supply Company, Hangzhou 310020, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5087011161","display_name":"Tao Niu","orcid":"https://orcid.org/0000-0003-4461-9481"},"institutions":[{"id":"https://openalex.org/I158842170","display_name":"Chongqing University","ror":"https://ror.org/023rhb549","country_code":"CN","type":"education","lineage":["https://openalex.org/I158842170"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Tao Niu","raw_affiliation_strings":["State Key Laboratory of Power Transmission Equipment and System Security at Chongqing University, Chongqing 400044, China. (e-mail: niutthu@qq.com)","State Key Laboratory of Power Transmission Equipment and System Security at Chongqing University, Chongqing 400044, China"],"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Power Transmission Equipment and System Security at Chongqing University, Chongqing 400044, China. (e-mail: niutthu@qq.com)","institution_ids":["https://openalex.org/I158842170"]},{"raw_affiliation_string":"State Key Laboratory of Power Transmission Equipment and System Security at Chongqing University, Chongqing 400044, China","institution_ids":["https://openalex.org/I158842170"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5109384635","display_name":"Pei Liao","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Pei Liao","raw_affiliation_strings":["State Grid Hangzhou Power Supply Company, Hangzhou 310020, China"],"affiliations":[{"raw_affiliation_string":"State Grid Hangzhou Power Supply Company, Hangzhou 310020, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101629933","display_name":"Xue Lin","orcid":"https://orcid.org/0000-0001-7048-6139"},"institutions":[{"id":"https://openalex.org/I158842170","display_name":"Chongqing University","ror":"https://ror.org/023rhb549","country_code":"CN","type":"education","lineage":["https://openalex.org/I158842170"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Lin Xue","raw_affiliation_strings":["State Key Laboratory of Power Transmission Equipment and System Security at Chongqing University, Chongqing 400044, China"],"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Power Transmission Equipment and System Security at Chongqing University, Chongqing 400044, China","institution_ids":["https://openalex.org/I158842170"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5107790951","display_name":"Yan Xia","orcid":"https://orcid.org/0000-0001-8839-3926"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Yan Xia","raw_affiliation_strings":["State Grid Hangzhou Power Supply Company, Hangzhou 310020, China"],"affiliations":[{"raw_affiliation_string":"State Grid Hangzhou Power Supply Company, Hangzhou 310020, China","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":10,"corresponding_author_ids":["https://openalex.org/A5101807659"],"corresponding_institution_ids":[],"apc_list":{"value":1850,"currency":"USD","value_usd":1850},"apc_paid":{"value":1850,"currency":"USD","value_usd":1850},"fwci":0.2747,"has_fulltext":true,"cited_by_count":2,"citation_normalized_percentile":{"value":0.56366893,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"9","issue":null,"first_page":"164769","last_page":"164778"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9933000206947327,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10796","display_name":"Cooperative Communication and Network Coding","score":0.9926000237464905,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/network-topology","display_name":"Network topology","score":0.8203967809677124},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6865615248680115},{"id":"https://openalex.org/keywords/robustness","display_name":"Robustness (evolution)","score":0.6755332350730896},{"id":"https://openalex.org/keywords/telecommunications-network","display_name":"Telecommunications network","score":0.5157371163368225},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.5010809898376465},{"id":"https://openalex.org/keywords/automatic-frequency-control","display_name":"Automatic frequency control","score":0.4648493826389313},{"id":"https://openalex.org/keywords/resilience","display_name":"Resilience (materials science)","score":0.42646387219429016},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.41701897978782654},{"id":"https://openalex.org/keywords/topology","display_name":"Topology (electrical circuits)","score":0.39614415168762207},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.21457970142364502},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.13879159092903137},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.11534211039543152}],"concepts":[{"id":"https://openalex.org/C199845137","wikidata":"https://www.wikidata.org/wiki/Q145490","display_name":"Network topology","level":2,"score":0.8203967809677124},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6865615248680115},{"id":"https://openalex.org/C63479239","wikidata":"https://www.wikidata.org/wiki/Q7353546","display_name":"Robustness (evolution)","level":3,"score":0.6755332350730896},{"id":"https://openalex.org/C192126672","wikidata":"https://www.wikidata.org/wiki/Q1068715","display_name":"Telecommunications network","level":2,"score":0.5157371163368225},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.5010809898376465},{"id":"https://openalex.org/C25915539","wikidata":"https://www.wikidata.org/wiki/Q220786","display_name":"Automatic frequency control","level":2,"score":0.4648493826389313},{"id":"https://openalex.org/C2779585090","wikidata":"https://www.wikidata.org/wiki/Q3457762","display_name":"Resilience (materials science)","level":2,"score":0.42646387219429016},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.41701897978782654},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.39614415168762207},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.21457970142364502},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.13879159092903137},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.11534211039543152},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C104317684","wikidata":"https://www.wikidata.org/wiki/Q7187","display_name":"Gene","level":2,"score":0.0},{"id":"https://openalex.org/C55493867","wikidata":"https://www.wikidata.org/wiki/Q7094","display_name":"Biochemistry","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/access.2021.3130642","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2021.3130642","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/6514899/09627170.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:817cc5dd597f46158adf94994c8ecd5f","is_oa":true,"landing_page_url":"https://doaj.org/article/817cc5dd597f46158adf94994c8ecd5f","pdf_url":null,"source":{"id":"https://openalex.org/S112646816","display_name":"SHILAP Revista de lepidopterolog\u00eda","issn_l":"0300-5267","issn":["0300-5267","2340-4078"],"is_oa":true,"is_in_doaj":true,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Access, Vol 9, Pp 164769-164778 (2021)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.1109/access.2021.3130642","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2021.3130642","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/6514899/09627170.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"sustainable_development_goals":[{"score":0.7599999904632568,"id":"https://metadata.un.org/sdg/13","display_name":"Climate action"}],"awards":[{"id":"https://openalex.org/G1866373937","display_name":null,"funder_award_id":"2021ZK35","funder_id":"https://openalex.org/F4320336311","funder_display_name":"State Grid Zhejiang Electric Power Company"}],"funders":[{"id":"https://openalex.org/F4320336311","display_name":"State Grid Zhejiang Electric Power Company","ror":null}],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W3216648065.pdf","grobid_xml":"https://content.openalex.org/works/W3216648065.grobid-xml"},"referenced_works_count":24,"referenced_works":["https://openalex.org/W1665876831","https://openalex.org/W1988837728","https://openalex.org/W1993958856","https://openalex.org/W2040711492","https://openalex.org/W2046944130","https://openalex.org/W2066822226","https://openalex.org/W2107396783","https://openalex.org/W2290410061","https://openalex.org/W2509627800","https://openalex.org/W2509677837","https://openalex.org/W2738399088","https://openalex.org/W2803111077","https://openalex.org/W2888193559","https://openalex.org/W2894506939","https://openalex.org/W2905912094","https://openalex.org/W2914074484","https://openalex.org/W2974143670","https://openalex.org/W2979745599","https://openalex.org/W2980677564","https://openalex.org/W3033102087","https://openalex.org/W3107574063","https://openalex.org/W3116555359","https://openalex.org/W3144812906","https://openalex.org/W3176472454"],"related_works":["https://openalex.org/W2086397253","https://openalex.org/W2133122801","https://openalex.org/W600422426","https://openalex.org/W2007156430","https://openalex.org/W2770593030","https://openalex.org/W3081478936","https://openalex.org/W3154990682","https://openalex.org/W2560201613","https://openalex.org/W2785612136","https://openalex.org/W2171975302"],"abstract_inverted_index":{"Mobile":[0],"emergency":[1,14],"resources":[2],"(MERs)":[3],"are":[4,114],"critical":[5],"to":[6,16,90,106,117],"the":[7,22,32,51,60,63,68,75,119,124],"resilience":[8],"of":[9,25,53,62,123],"distribution":[10,76],"systems":[11],"for":[12],"an":[13],"response":[15],"natural":[17],"disasters.":[18],"However,":[19],"after":[20,78],"disasters,":[21],"communication":[23,33,65,100,130],"network":[24,66],"MERs":[26],"may":[27,45],"be":[28],"unreliable.":[29],"For":[30],"example,":[31],"topology":[34],"switches":[35],"in":[36,95,108],"different":[37],"modes":[38],"randomly.":[39],"The":[40,102],"conventional":[41],"centralized":[42],"control":[43,70,86,126],"algorithms":[44],"not":[46],"converge.":[47],"As":[48],"a":[49,109],"result,":[50],"instability":[52],"frequency":[54,92],"and":[55,93,121],"voltage":[56,94],"happened.":[57],"To":[58],"alleviate":[59],"impacts":[61],"unreliable":[64],"on":[67],"second":[69],"performance,":[71],"this":[72],"paper":[73],"regards":[74],"system":[77],"disasters":[79],"as":[80],"multiple":[81],"microgrids.":[82],"A":[83],"distributed":[84],"secondary":[85],"algorithm":[87,103,127],"is":[88,104],"designed":[89],"regulate":[91],"islanded":[96],"microgrids":[97],"over":[98],"switching":[99,129],"topologies.":[101,131],"guaranteed":[105],"converge":[107],"fixed":[110],"time.":[111],"Case":[112],"studies":[113],"carried":[115],"out":[116],"demonstrate":[118],"effectiveness":[120],"robustness":[122],"proposed":[125],"under":[128]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}