{"id":"https://openalex.org/W3135066433","doi":"https://doi.org/10.1109/access.2021.3064347","title":"Diagnosis of Inter-Turn Shorts of Loaded Transformer Under Various Load Currents and Power Factors; Impulse Voltage-Based Frequency Response Approach","display_name":"Diagnosis of Inter-Turn Shorts of Loaded Transformer Under Various Load Currents and Power Factors; Impulse Voltage-Based Frequency Response Approach","publication_year":2021,"publication_date":"2021-01-01","ids":{"openalex":"https://openalex.org/W3135066433","doi":"https://doi.org/10.1109/access.2021.3064347","mag":"3135066433"},"language":"en","primary_location":{"id":"doi:10.1109/access.2021.3064347","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2021.3064347","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://doi.org/10.1109/access.2021.3064347","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5086569350","display_name":"N. Shanmugam","orcid":null},"institutions":[{"id":"https://openalex.org/I932239252","display_name":"SASTRA University","ror":"https://ror.org/032jk8892","country_code":"IN","type":"education","lineage":["https://openalex.org/I932239252"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"Natarajan Shanmugam","raw_affiliation_strings":["Department of Electrical and Electronics Engineering, Shanmugha Arts, Science, Technology and Research Academy (SASTRA), Deemed University, Thanjavur, India","ORCiD"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Electronics Engineering, Shanmugha Arts, Science, Technology and Research Academy (SASTRA), Deemed University, Thanjavur, India","institution_ids":["https://openalex.org/I932239252"]},{"raw_affiliation_string":"ORCiD","institution_ids":[]}]},{"author_position":"middle","author":{"id":null,"display_name":"Srinivasan Gopal","orcid":"https://orcid.org/0000-0002-2511-0703"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Srinivasan Gopal","raw_affiliation_strings":["W.S. Test Systems, Bengaluru, India","ORCiD"],"affiliations":[{"raw_affiliation_string":"W.S. Test Systems, Bengaluru, India","institution_ids":[]},{"raw_affiliation_string":"ORCiD","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101849091","display_name":"Balasubramanian Madanmohan","orcid":"https://orcid.org/0000-0002-1345-367X"},"institutions":[{"id":"https://openalex.org/I932239252","display_name":"SASTRA University","ror":"https://ror.org/032jk8892","country_code":"IN","type":"education","lineage":["https://openalex.org/I932239252"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Balasubramanian Madanmohan","raw_affiliation_strings":["Department of Electrical and Electronics Engineering, Shanmugha Arts, Science, Technology and Research Academy (SASTRA), Deemed University, Thanjavur, India","ORCiD"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Electronics Engineering, Shanmugha Arts, Science, Technology and Research Academy (SASTRA), Deemed University, Thanjavur, India","institution_ids":["https://openalex.org/I932239252"]},{"raw_affiliation_string":"ORCiD","institution_ids":[]}]},{"author_position":"middle","author":{"id":null,"display_name":"S. P. Balaji","orcid":"https://orcid.org/0000-0002-3684-5000"},"institutions":[{"id":"https://openalex.org/I109493002","display_name":"Central Power Research Institute","ror":"https://ror.org/00d1evr30","country_code":"IN","type":"government","lineage":["https://openalex.org/I109493002"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"S. P. Balaji","raw_affiliation_strings":["Global Power Research Institute (GPRI), Cuddalore, India","ORCiD"],"affiliations":[{"raw_affiliation_string":"Global Power Research Institute (GPRI), Cuddalore, India","institution_ids":["https://openalex.org/I109493002"]},{"raw_affiliation_string":"ORCiD","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5101744245","display_name":"Rajesh Rajamani","orcid":"https://orcid.org/0000-0001-7535-8777"},"institutions":[{"id":"https://openalex.org/I932239252","display_name":"SASTRA University","ror":"https://ror.org/032jk8892","country_code":"IN","type":"education","lineage":["https://openalex.org/I932239252"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Rajesh Rajamani","raw_affiliation_strings":["Department of Electrical and Electronics Engineering, Shanmugha Arts, Science, Technology and Research Academy (SASTRA), Deemed University, Thanjavur, India","ORCiD"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Electronics Engineering, Shanmugha Arts, Science, Technology and Research Academy (SASTRA), Deemed University, Thanjavur, India","institution_ids":["https://openalex.org/I932239252"]},{"raw_affiliation_string":"ORCiD","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5086569350"],"corresponding_institution_ids":["https://openalex.org/I932239252"],"apc_list":{"value":1850,"currency":"USD","value_usd":1850},"apc_paid":{"value":1850,"currency":"USD","value_usd":1850},"fwci":0.6097,"has_fulltext":false,"cited_by_count":8,"citation_normalized_percentile":{"value":0.66202685,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":97},"biblio":{"volume":"9","issue":null,"first_page":"40811","last_page":"40822"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.9988999962806702,"subfield":{"id":"https://openalex.org/subfields/2505","display_name":"Materials Chemistry"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11222","display_name":"Magnetic Properties and Applications","score":0.9958999752998352,"subfield":{"id":"https://openalex.org/subfields/2504","display_name":"Electronic, Optical and Magnetic Materials"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/distribution-transformer","display_name":"Distribution transformer","score":0.6786818504333496},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.6087089776992798},{"id":"https://openalex.org/keywords/energy-efficient-transformer","display_name":"Energy efficient transformer","score":0.583461582660675},{"id":"https://openalex.org/keywords/delta-wye-transformer","display_name":"Delta-wye transformer","score":0.5330288410186768},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.5151535272598267},{"id":"https://openalex.org/keywords/electromagnetic-coil","display_name":"Electromagnetic coil","score":0.46497607231140137},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4459901750087738},{"id":"https://openalex.org/keywords/power-factor","display_name":"Power factor","score":0.4275650084018707},{"id":"https://openalex.org/keywords/current-transformer","display_name":"Current transformer","score":0.41805386543273926},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.38029831647872925},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.3310808837413788}],"concepts":[{"id":"https://openalex.org/C117323899","wikidata":"https://www.wikidata.org/wiki/Q1907989","display_name":"Distribution transformer","level":4,"score":0.6786818504333496},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.6087089776992798},{"id":"https://openalex.org/C9121194","wikidata":"https://www.wikidata.org/wiki/Q5377050","display_name":"Energy efficient transformer","level":5,"score":0.583461582660675},{"id":"https://openalex.org/C138838965","wikidata":"https://www.wikidata.org/wiki/Q1258026","display_name":"Delta-wye transformer","level":5,"score":0.5330288410186768},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5151535272598267},{"id":"https://openalex.org/C30403606","wikidata":"https://www.wikidata.org/wiki/Q2981904","display_name":"Electromagnetic coil","level":2,"score":0.46497607231140137},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4459901750087738},{"id":"https://openalex.org/C64424096","wikidata":"https://www.wikidata.org/wiki/Q750454","display_name":"Power factor","level":3,"score":0.4275650084018707},{"id":"https://openalex.org/C133770746","wikidata":"https://www.wikidata.org/wiki/Q856535","display_name":"Current transformer","level":4,"score":0.41805386543273926},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.38029831647872925},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3310808837413788}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/access.2021.3064347","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2021.3064347","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:e220530dee7249c18a06a2790837547a","is_oa":true,"landing_page_url":"https://doaj.org/article/e220530dee7249c18a06a2790837547a","pdf_url":null,"source":{"id":"https://openalex.org/S112646816","display_name":"SHILAP Revista de lepidopterolog\u00eda","issn_l":"0300-5267","issn":["0300-5267","2340-4078"],"is_oa":true,"is_in_doaj":true,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Access, Vol 9, Pp 40811-40822 (2021)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.1109/access.2021.3064347","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2021.3064347","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.8500000238418579,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":29,"referenced_works":["https://openalex.org/W2004490681","https://openalex.org/W2010836831","https://openalex.org/W2015636842","https://openalex.org/W2035211726","https://openalex.org/W2042063379","https://openalex.org/W2050124321","https://openalex.org/W2074939239","https://openalex.org/W2111631801","https://openalex.org/W2123399671","https://openalex.org/W2131449031","https://openalex.org/W2136061582","https://openalex.org/W2147602330","https://openalex.org/W2150462500","https://openalex.org/W2315435332","https://openalex.org/W2326627434","https://openalex.org/W2346313263","https://openalex.org/W2541526644","https://openalex.org/W2604206045","https://openalex.org/W2734710128","https://openalex.org/W2740950875","https://openalex.org/W2745913135","https://openalex.org/W2772996055","https://openalex.org/W2887158351","https://openalex.org/W2888958752","https://openalex.org/W2891478690","https://openalex.org/W2963098347","https://openalex.org/W2965005217","https://openalex.org/W3008367020","https://openalex.org/W4256038846"],"related_works":["https://openalex.org/W3017739981","https://openalex.org/W2048016652","https://openalex.org/W2963477019","https://openalex.org/W2378847117","https://openalex.org/W2774734052","https://openalex.org/W4251988900","https://openalex.org/W2367749627","https://openalex.org/W2009258334","https://openalex.org/W3161194314","https://openalex.org/W2392597137"],"abstract_inverted_index":{"Inter-turn":[0],"short":[1,119],"circuits":[2,120],"within":[3],"the":[4,10,19,26,33,38,99,107,112,124,150,153,160,163,167,173,180,184,197],"transformer":[5,71,154],"winding":[6],"are":[7,169],"diagnosable":[8],"through":[9],"impulse":[11],"voltage":[12],"based":[13,41,186],"frequency":[14,39,174],"response":[15,40,182],"analysis":[16],"(IFRA).":[17],"If":[18],"diagnosis":[20],"is":[21],"made":[22],"Online,":[23],"interruption":[24],"to":[25,88,171],"power":[27,87,94,104,164],"network":[28],"can":[29],"be":[30,145],"avoided.":[31],"However,":[32],"transformer\u2019s":[34,113],"load":[35,100,142,168],"may":[36],"influence":[37,97,172],"diagnostic":[42],"process,":[43],"and":[44,72,93,102,116,162,195],"this":[45,54],"aspect":[46],"has":[47],"not":[48],"yet":[49],"been":[50],"investigated.":[51],"Motivated":[52],"by":[53],"research":[55],"gap,":[56],"experimental":[57],"investigations":[58],"were":[59,85],"carried":[60],"out":[61],"on":[62,106,187],"a":[63,73,134,140,156],"three-phase":[64,74],"5":[65],"kVA,":[66,76],"440":[67],"V/440":[68],"V":[69],"Star/Delta":[70],"315":[75],"11":[77],"kV/433":[78],"V,":[79],"Dyn11":[80],"distribution":[81],"transformer,":[82,185],"when":[83],"they":[84],"supplying":[86],"loads":[89],"of":[90,98,123,152,166,179,183],"different":[91,129,157],"magnitudes":[92],"factors.":[95],"The":[96],"current":[101],"its":[103,188],"factor":[105,165],"IFRA":[108],"was":[109,190],"observed":[110],"under":[111,127],"healthy":[114],"condition":[115,143,151],"with":[117],"inter-turn":[118,198],"in":[121,193],"one":[122],"windings.":[125],"Investigations":[126],"these":[128],"loaded":[130],"conditions":[131],"revealed":[132],"that":[133],"signature":[135],"FRA":[136],"plot":[137],"developed":[138],"at":[139,155],"particular":[141],"cannot":[144],"directly":[146],"used":[147],"for":[148],"assessing":[149],"load.":[158],"Both":[159],"magnitude":[161],"found":[170,191],"response.":[175],"A":[176],"careful":[177],"interpretation":[178],"Frequency":[181],"load,":[189],"effective":[192],"detecting":[194],"locating":[196],"shorts.":[199]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2023,"cited_by_count":3},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":2}],"updated_date":"2026-04-15T08:11:43.952461","created_date":"2025-10-10T00:00:00"}