{"id":"https://openalex.org/W3093486115","doi":"https://doi.org/10.1109/access.2020.3033425","title":"Void Fraction Measurement in a Gas-Liquid Swirling Flow Using an Ultrasonic Sensor","display_name":"Void Fraction Measurement in a Gas-Liquid Swirling Flow Using an Ultrasonic Sensor","publication_year":2020,"publication_date":"2020-01-01","ids":{"openalex":"https://openalex.org/W3093486115","doi":"https://doi.org/10.1109/access.2020.3033425","mag":"3093486115"},"language":"en","primary_location":{"id":"doi:10.1109/access.2020.3033425","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2020.3033425","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/8948470/09237984.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://ieeexplore.ieee.org/ielx7/6287639/8948470/09237984.pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5076033783","display_name":"C\u00e9sar Y. Ofuchi","orcid":"https://orcid.org/0000-0003-3925-086X"},"institutions":[{"id":"https://openalex.org/I1283613182","display_name":"Universidade Tecnol\u00f3gica Federal do Paran\u00e1","ror":"https://ror.org/002v2kq79","country_code":"BR","type":"education","lineage":["https://openalex.org/I1283613182"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Cesar Yutaka Ofuchi","raw_affiliation_strings":["Graduate Program in Electrical and Computer Engineering (CPGEI), Federal University of Technology-Parana, Curitiba, Brazil","Multiphase Flow Research Center (NUEM), Federal University of Technology-Parana, Curitiba, Brazil"],"raw_orcid":"https://orcid.org/0000-0003-3925-086X","affiliations":[{"raw_affiliation_string":"Graduate Program in Electrical and Computer Engineering (CPGEI), Federal University of Technology-Parana, Curitiba, Brazil","institution_ids":["https://openalex.org/I1283613182"]},{"raw_affiliation_string":"Multiphase Flow Research Center (NUEM), Federal University of Technology-Parana, Curitiba, Brazil","institution_ids":["https://openalex.org/I1283613182"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5035673204","display_name":"Henrique Krainer Eidt","orcid":null},"institutions":[{"id":"https://openalex.org/I1283613182","display_name":"Universidade Tecnol\u00f3gica Federal do Paran\u00e1","ror":"https://ror.org/002v2kq79","country_code":"BR","type":"education","lineage":["https://openalex.org/I1283613182"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Henrique Krainer Eidt","raw_affiliation_strings":["Multiphase Flow Research Center (NUEM), Federal University of Technology-Parana, Curitiba, Brazil","Graduate Program in Mechanical and Materials Engineering (PPGEM), Federal University of Technology-Parana, Curitiba, Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Multiphase Flow Research Center (NUEM), Federal University of Technology-Parana, Curitiba, Brazil","institution_ids":["https://openalex.org/I1283613182"]},{"raw_affiliation_string":"Graduate Program in Mechanical and Materials Engineering (PPGEM), Federal University of Technology-Parana, Curitiba, Brazil","institution_ids":["https://openalex.org/I1283613182"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5082215874","display_name":"Dalton Bertoldi","orcid":"https://orcid.org/0000-0003-3318-8903"},"institutions":[{"id":"https://openalex.org/I1283613182","display_name":"Universidade Tecnol\u00f3gica Federal do Paran\u00e1","ror":"https://ror.org/002v2kq79","country_code":"BR","type":"education","lineage":["https://openalex.org/I1283613182"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Dalton Bertoldi","raw_affiliation_strings":["Multiphase Flow Research Center (NUEM), Federal University of Technology-Parana, Curitiba, Brazil"],"raw_orcid":"https://orcid.org/0000-0003-3318-8903","affiliations":[{"raw_affiliation_string":"Multiphase Flow Research Center (NUEM), Federal University of Technology-Parana, Curitiba, Brazil","institution_ids":["https://openalex.org/I1283613182"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5017487342","display_name":"Marco J. da Silva","orcid":"https://orcid.org/0000-0003-1955-8293"},"institutions":[{"id":"https://openalex.org/I1283613182","display_name":"Universidade Tecnol\u00f3gica Federal do Paran\u00e1","ror":"https://ror.org/002v2kq79","country_code":"BR","type":"education","lineage":["https://openalex.org/I1283613182"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Marco Jose Da Silva","raw_affiliation_strings":["Graduate Program in Electrical and Computer Engineering (CPGEI), Federal University of Technology-Parana, Curitiba, Brazil","Multiphase Flow Research Center (NUEM), Federal University of Technology-Parana, Curitiba, Brazil"],"raw_orcid":"https://orcid.org/0000-0003-1955-8293","affiliations":[{"raw_affiliation_string":"Graduate Program in Electrical and Computer Engineering (CPGEI), Federal University of Technology-Parana, Curitiba, Brazil","institution_ids":["https://openalex.org/I1283613182"]},{"raw_affiliation_string":"Multiphase Flow Research Center (NUEM), Federal University of Technology-Parana, Curitiba, Brazil","institution_ids":["https://openalex.org/I1283613182"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5031182921","display_name":"Rigoberto Morales","orcid":"https://orcid.org/0000-0003-3297-7361"},"institutions":[{"id":"https://openalex.org/I1283613182","display_name":"Universidade Tecnol\u00f3gica Federal do Paran\u00e1","ror":"https://ror.org/002v2kq79","country_code":"BR","type":"education","lineage":["https://openalex.org/I1283613182"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Rigoberto E. M. Morales","raw_affiliation_strings":["Multiphase Flow Research Center (NUEM), Federal University of Technology-Parana, Curitiba, Brazil","Graduate Program in Mechanical and Materials Engineering (PPGEM), Federal University of Technology-Parana, Curitiba, Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Multiphase Flow Research Center (NUEM), Federal University of Technology-Parana, Curitiba, Brazil","institution_ids":["https://openalex.org/I1283613182"]},{"raw_affiliation_string":"Graduate Program in Mechanical and Materials Engineering (PPGEM), Federal University of Technology-Parana, Curitiba, Brazil","institution_ids":["https://openalex.org/I1283613182"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5009972800","display_name":"Fl\u00e1vio Neves","orcid":"https://orcid.org/0000-0002-1627-1425"},"institutions":[{"id":"https://openalex.org/I1283613182","display_name":"Universidade Tecnol\u00f3gica Federal do Paran\u00e1","ror":"https://ror.org/002v2kq79","country_code":"BR","type":"education","lineage":["https://openalex.org/I1283613182"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Flavio Neves","raw_affiliation_strings":["Graduate Program in Electrical and Computer Engineering (CPGEI), Federal University of Technology-Parana, Curitiba, Brazil","Multiphase Flow Research Center (NUEM), Federal University of Technology-Parana, Curitiba, Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Graduate Program in Electrical and Computer Engineering (CPGEI), Federal University of Technology-Parana, Curitiba, Brazil","institution_ids":["https://openalex.org/I1283613182"]},{"raw_affiliation_string":"Multiphase Flow Research Center (NUEM), Federal University of Technology-Parana, Curitiba, Brazil","institution_ids":["https://openalex.org/I1283613182"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":6,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":1850,"currency":"USD","value_usd":1850},"apc_paid":{"value":1850,"currency":"USD","value_usd":1850},"fwci":0.4357,"has_fulltext":true,"cited_by_count":12,"citation_normalized_percentile":{"value":0.59331334,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":98},"biblio":{"volume":"8","issue":null,"first_page":"194477","last_page":"194484"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10864","display_name":"Fluid Dynamics and Mixing","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10864","display_name":"Fluid Dynamics and Mixing","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12537","display_name":"Flow Measurement and Analysis","score":0.9986000061035156,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11401","display_name":"Minerals Flotation and Separation Techniques","score":0.9961000084877014,"subfield":{"id":"https://openalex.org/subfields/2312","display_name":"Water Science and Technology"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ultrasonic-sensor","display_name":"Ultrasonic sensor","score":0.7294239401817322},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.6839016675949097},{"id":"https://openalex.org/keywords/porosity","display_name":"Porosity","score":0.6166887879371643},{"id":"https://openalex.org/keywords/void","display_name":"Void (composites)","score":0.56852787733078},{"id":"https://openalex.org/keywords/flow-measurement","display_name":"Flow measurement","score":0.5604610443115234},{"id":"https://openalex.org/keywords/ultrasonic-flow-meter","display_name":"Ultrasonic flow meter","score":0.5416584014892578},{"id":"https://openalex.org/keywords/ultrasound","display_name":"Ultrasound","score":0.532328724861145},{"id":"https://openalex.org/keywords/mechanics","display_name":"Mechanics","score":0.4950084090232849},{"id":"https://openalex.org/keywords/two-phase-flow","display_name":"Two-phase flow","score":0.46442142128944397},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.4462149739265442},{"id":"https://openalex.org/keywords/volumetric-flow-rate","display_name":"Volumetric flow rate","score":0.4291534423828125},{"id":"https://openalex.org/keywords/root-mean-square","display_name":"Root mean square","score":0.4173929989337921},{"id":"https://openalex.org/keywords/flow","display_name":"Flow (mathematics)","score":0.40525931119918823},{"id":"https://openalex.org/keywords/analytical-chemistry","display_name":"Analytical Chemistry (journal)","score":0.3298684358596802},{"id":"https://openalex.org/keywords/composite-material","display_name":"Composite material","score":0.32806992530822754},{"id":"https://openalex.org/keywords/chromatography","display_name":"Chromatography","score":0.17719879746437073},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.15223360061645508},{"id":"https://openalex.org/keywords/chemistry","display_name":"Chemistry","score":0.14462894201278687},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.12000709772109985},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.07776710391044617}],"concepts":[{"id":"https://openalex.org/C81288441","wikidata":"https://www.wikidata.org/wiki/Q20736125","display_name":"Ultrasonic sensor","level":2,"score":0.7294239401817322},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.6839016675949097},{"id":"https://openalex.org/C6648577","wikidata":"https://www.wikidata.org/wiki/Q622669","display_name":"Porosity","level":2,"score":0.6166887879371643},{"id":"https://openalex.org/C2779772531","wikidata":"https://www.wikidata.org/wiki/Q19689164","display_name":"Void (composites)","level":2,"score":0.56852787733078},{"id":"https://openalex.org/C16302685","wikidata":"https://www.wikidata.org/wiki/Q15091623","display_name":"Flow measurement","level":2,"score":0.5604610443115234},{"id":"https://openalex.org/C63066824","wikidata":"https://www.wikidata.org/wiki/Q2165466","display_name":"Ultrasonic flow meter","level":3,"score":0.5416584014892578},{"id":"https://openalex.org/C143753070","wikidata":"https://www.wikidata.org/wiki/Q162564","display_name":"Ultrasound","level":2,"score":0.532328724861145},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.4950084090232849},{"id":"https://openalex.org/C144308804","wikidata":"https://www.wikidata.org/wiki/Q232997","display_name":"Two-phase flow","level":3,"score":0.46442142128944397},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.4462149739265442},{"id":"https://openalex.org/C172120300","wikidata":"https://www.wikidata.org/wiki/Q1134348","display_name":"Volumetric flow rate","level":2,"score":0.4291534423828125},{"id":"https://openalex.org/C71907059","wikidata":"https://www.wikidata.org/wiki/Q223323","display_name":"Root mean square","level":2,"score":0.4173929989337921},{"id":"https://openalex.org/C38349280","wikidata":"https://www.wikidata.org/wiki/Q1434290","display_name":"Flow (mathematics)","level":2,"score":0.40525931119918823},{"id":"https://openalex.org/C113196181","wikidata":"https://www.wikidata.org/wiki/Q485223","display_name":"Analytical Chemistry (journal)","level":2,"score":0.3298684358596802},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.32806992530822754},{"id":"https://openalex.org/C43617362","wikidata":"https://www.wikidata.org/wiki/Q170050","display_name":"Chromatography","level":1,"score":0.17719879746437073},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.15223360061645508},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.14462894201278687},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.12000709772109985},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.07776710391044617}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/access.2020.3033425","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2020.3033425","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/8948470/09237984.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:aa377f27ac4a40d7856535d7f822fb7f","is_oa":true,"landing_page_url":"https://doaj.org/article/aa377f27ac4a40d7856535d7f822fb7f","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Access, Vol 8, Pp 194477-194484 (2020)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.1109/access.2020.3033425","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2020.3033425","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/8948470/09237984.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"sustainable_development_goals":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320321091","display_name":"Coordena\u00e7\u00e3o de Aperfei\u00e7oamento de Pessoal de N\u00edvel Superior","ror":"https://ror.org/00x0ma614"},{"id":"https://openalex.org/F4320322025","display_name":"Conselho Nacional de Desenvolvimento Cient\u00edfico e Tecnol\u00f3gico","ror":"https://ror.org/03swz6y49"},{"id":"https://openalex.org/F4320322468","display_name":"Petrobras","ror":"https://ror.org/0235kyq22"},{"id":"https://openalex.org/F4320322904","display_name":"Financiadora de Estudos e Projetos","ror":"https://ror.org/030w99567"}],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W3093486115.pdf","grobid_xml":"https://content.openalex.org/works/W3093486115.grobid-xml"},"referenced_works_count":31,"referenced_works":["https://openalex.org/W1170214759","https://openalex.org/W1481473432","https://openalex.org/W1766888123","https://openalex.org/W1963991705","https://openalex.org/W1976028596","https://openalex.org/W1990101252","https://openalex.org/W2001028188","https://openalex.org/W2001254464","https://openalex.org/W2033945014","https://openalex.org/W2044762986","https://openalex.org/W2081297406","https://openalex.org/W2088017925","https://openalex.org/W2091114832","https://openalex.org/W2091398243","https://openalex.org/W2148196487","https://openalex.org/W2200902360","https://openalex.org/W2326954665","https://openalex.org/W2392339705","https://openalex.org/W2696639487","https://openalex.org/W2773233464","https://openalex.org/W2806105913","https://openalex.org/W2873123678","https://openalex.org/W2906713832","https://openalex.org/W2925310335","https://openalex.org/W2978292925","https://openalex.org/W2989969228","https://openalex.org/W3018189068","https://openalex.org/W3109938142","https://openalex.org/W4237010734","https://openalex.org/W4300752724","https://openalex.org/W6628943719"],"related_works":["https://openalex.org/W2371824631","https://openalex.org/W4366315075","https://openalex.org/W4366320868","https://openalex.org/W4366320126","https://openalex.org/W2350425252","https://openalex.org/W2906209913","https://openalex.org/W2351040364","https://openalex.org/W2354654388","https://openalex.org/W2005252818","https://openalex.org/W2057718659"],"abstract_inverted_index":{"In":[0],"this":[1],"article,":[2],"we":[3],"propose":[4,41],"a":[5,16,30,36,67,70,78,131],"novel":[6],"ultrasonic":[7,94],"technique":[8],"to":[9,29,56,106],"measure":[10],"the":[11,24,42,45,51,58,92,97,107,121],"gas":[12,31,73,126],"void":[13,32,74,127],"fraction":[14,33,75,128],"in":[15,77,130],"liquid-gas":[17],"intermittent":[18],"swirling":[19,133],"flow.":[20,134],"The":[21,62,113],"method":[22,95,111,119],"converts":[23],"liquid":[25,59],"film":[26,60,109],"thickness":[27,110],"measurement":[28,129],"value":[34],"considering":[35],"symmetrical":[37],"flow":[38,82],"pattern.":[39],"We":[40],"use":[43,122],"of":[44,50,87,102,123],"first":[46],"echo":[47,54],"peak":[48,55],"instead":[49],"standard":[52,108],"maximum":[53],"estimate":[57],"thickness.":[61],"results":[63],"are":[64],"compared":[65,105],"with":[66],"wire-mesh":[68],"sensor,":[69],"reference":[71,98],"for":[72,125],"measurement,":[76],"1-inch":[79],"inner-diameter":[80],"vertical":[81],"loop.":[83],"A":[84],"Root-Mean-Square-Deviation":[85],"(RMSD)":[86],"2.87%":[88],"was":[89],"observed":[90],"between":[91],"proposed":[93],"and":[96],"sensor.":[99],"An":[100],"improvement":[101],"6.06%":[103],"if":[104],"(8.93%).":[112],"studied":[114],"cases":[115],"show":[116],"that":[117],"our":[118],"improves":[120],"ultrasound":[124],"gas-liquid":[132]},"counts_by_year":[{"year":2025,"cited_by_count":4},{"year":2024,"cited_by_count":3},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
