{"id":"https://openalex.org/W3012536983","doi":"https://doi.org/10.1109/access.2020.2981825","title":"A Practical Large-Scale Distribution Network Planning Model Based on Elite Ant-Q","display_name":"A Practical Large-Scale Distribution Network Planning Model Based on Elite Ant-Q","publication_year":2020,"publication_date":"2020-01-01","ids":{"openalex":"https://openalex.org/W3012536983","doi":"https://doi.org/10.1109/access.2020.2981825","mag":"3012536983"},"language":"en","primary_location":{"id":"doi:10.1109/access.2020.2981825","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2020.2981825","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/8948470/09040513.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://ieeexplore.ieee.org/ielx7/6287639/8948470/09040513.pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100653211","display_name":"Ziyao Wang","orcid":"https://orcid.org/0000-0003-0195-1038"},"institutions":[{"id":"https://openalex.org/I90610280","display_name":"South China University of Technology","ror":"https://ror.org/0530pts50","country_code":"CN","type":"education","lineage":["https://openalex.org/I90610280"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Ziyao Wang","raw_affiliation_strings":["Guangdong Key Laboratory of Clean Energy Technology, South China University of Technology, Guangzhou, China","School of Electric Power, South China University of Technology, Guangzhou, China"],"raw_orcid":"https://orcid.org/0000-0003-0195-1038","affiliations":[{"raw_affiliation_string":"Guangdong Key Laboratory of Clean Energy Technology, South China University of Technology, Guangzhou, China","institution_ids":["https://openalex.org/I90610280"]},{"raw_affiliation_string":"School of Electric Power, South China University of Technology, Guangzhou, China","institution_ids":["https://openalex.org/I90610280"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5009206672","display_name":"Dan Lin","orcid":"https://orcid.org/0000-0002-0914-6255"},"institutions":[{"id":"https://openalex.org/I90610280","display_name":"South China University of Technology","ror":"https://ror.org/0530pts50","country_code":"CN","type":"education","lineage":["https://openalex.org/I90610280"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Dan Lin","raw_affiliation_strings":["Guangdong Key Laboratory of Clean Energy Technology, South China University of Technology, Guangzhou, China","School of Electric Power, South China University of Technology, Guangzhou, China"],"raw_orcid":"https://orcid.org/0000-0002-0914-6255","affiliations":[{"raw_affiliation_string":"Guangdong Key Laboratory of Clean Energy Technology, South China University of Technology, Guangzhou, China","institution_ids":["https://openalex.org/I90610280"]},{"raw_affiliation_string":"School of Electric Power, South China University of Technology, Guangzhou, China","institution_ids":["https://openalex.org/I90610280"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5006146675","display_name":"Guangxuan Zeng","orcid":"https://orcid.org/0000-0001-9826-9937"},"institutions":[{"id":"https://openalex.org/I90610280","display_name":"South China University of Technology","ror":"https://ror.org/0530pts50","country_code":"CN","type":"education","lineage":["https://openalex.org/I90610280"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Guangxuan Zeng","raw_affiliation_strings":["Guangdong Key Laboratory of Clean Energy Technology, South China University of Technology, Guangzhou, China","School of Electric Power, South China University of Technology, Guangzhou, China"],"raw_orcid":"https://orcid.org/0000-0001-9826-9937","affiliations":[{"raw_affiliation_string":"Guangdong Key Laboratory of Clean Energy Technology, South China University of Technology, Guangzhou, China","institution_ids":["https://openalex.org/I90610280"]},{"raw_affiliation_string":"School of Electric Power, South China University of Technology, Guangzhou, China","institution_ids":["https://openalex.org/I90610280"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5057697869","display_name":"Tao Yu","orcid":"https://orcid.org/0000-0002-0143-261X"},"institutions":[{"id":"https://openalex.org/I90610280","display_name":"South China University of Technology","ror":"https://ror.org/0530pts50","country_code":"CN","type":"education","lineage":["https://openalex.org/I90610280"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Tao Yu","raw_affiliation_strings":["Guangdong Key Laboratory of Clean Energy Technology, South China University of Technology, Guangzhou, China","School of Electric Power, South China University of Technology, Guangzhou, China"],"raw_orcid":"https://orcid.org/0000-0002-0143-261X","affiliations":[{"raw_affiliation_string":"Guangdong Key Laboratory of Clean Energy Technology, South China University of Technology, Guangzhou, China","institution_ids":["https://openalex.org/I90610280"]},{"raw_affiliation_string":"School of Electric Power, South China University of Technology, Guangzhou, China","institution_ids":["https://openalex.org/I90610280"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":1850,"currency":"USD","value_usd":1850},"apc_paid":{"value":1850,"currency":"USD","value_usd":1850},"fwci":1.4569,"has_fulltext":true,"cited_by_count":21,"citation_normalized_percentile":{"value":0.81715799,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":98},"biblio":{"volume":"8","issue":null,"first_page":"58912","last_page":"58922"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T14276","display_name":"Power Systems and Technologies","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T14276","display_name":"Power Systems and Technologies","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12451","display_name":"Smart Grid and Power Systems","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9972000122070312,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.734457790851593},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.5566949844360352},{"id":"https://openalex.org/keywords/coding","display_name":"Coding (social sciences)","score":0.5030240416526794},{"id":"https://openalex.org/keywords/mathematical-optimization","display_name":"Mathematical optimization","score":0.47783327102661133},{"id":"https://openalex.org/keywords/network-model","display_name":"Network model","score":0.46002355217933655},{"id":"https://openalex.org/keywords/scale","display_name":"Scale (ratio)","score":0.4436691701412201},{"id":"https://openalex.org/keywords/ant-colony-optimization-algorithms","display_name":"Ant colony optimization algorithms","score":0.44018465280532837},{"id":"https://openalex.org/keywords/graph","display_name":"Graph","score":0.4182227849960327},{"id":"https://openalex.org/keywords/algorithm","display_name":"Algorithm","score":0.27790531516075134},{"id":"https://openalex.org/keywords/data-mining","display_name":"Data mining","score":0.2728636860847473},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.13607001304626465},{"id":"https://openalex.org/keywords/theoretical-computer-science","display_name":"Theoretical computer science","score":0.10017779469490051}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.734457790851593},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.5566949844360352},{"id":"https://openalex.org/C179518139","wikidata":"https://www.wikidata.org/wiki/Q5140297","display_name":"Coding (social sciences)","level":2,"score":0.5030240416526794},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.47783327102661133},{"id":"https://openalex.org/C104122410","wikidata":"https://www.wikidata.org/wiki/Q1416406","display_name":"Network model","level":2,"score":0.46002355217933655},{"id":"https://openalex.org/C2778755073","wikidata":"https://www.wikidata.org/wiki/Q10858537","display_name":"Scale (ratio)","level":2,"score":0.4436691701412201},{"id":"https://openalex.org/C40128228","wikidata":"https://www.wikidata.org/wiki/Q460851","display_name":"Ant colony optimization algorithms","level":2,"score":0.44018465280532837},{"id":"https://openalex.org/C132525143","wikidata":"https://www.wikidata.org/wiki/Q141488","display_name":"Graph","level":2,"score":0.4182227849960327},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.27790531516075134},{"id":"https://openalex.org/C124101348","wikidata":"https://www.wikidata.org/wiki/Q172491","display_name":"Data mining","level":1,"score":0.2728636860847473},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.13607001304626465},{"id":"https://openalex.org/C80444323","wikidata":"https://www.wikidata.org/wiki/Q2878974","display_name":"Theoretical computer science","level":1,"score":0.10017779469490051},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/access.2020.2981825","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2020.2981825","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/8948470/09040513.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:ee10eddb523c4c11882b86f286e9e70a","is_oa":true,"landing_page_url":"https://doaj.org/article/ee10eddb523c4c11882b86f286e9e70a","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Access, Vol 8, Pp 58912-58922 (2020)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.1109/access.2020.2981825","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2020.2981825","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/8948470/09040513.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/11","score":0.49000000953674316,"display_name":"Sustainable cities and communities"}],"awards":[{"id":"https://openalex.org/G3190776308","display_name":null,"funder_award_id":"2018KZDXM001","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G4525713837","display_name":null,"funder_award_id":"51777078","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G872480339","display_name":null,"funder_award_id":"GDKJXM20172942","funder_id":"https://openalex.org/F4320323192","funder_display_name":"China Southern Power Grid"}],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"},{"id":"https://openalex.org/F4320323192","display_name":"China Southern Power Grid","ror":"https://ror.org/03hkh9419"}],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W3012536983.pdf","grobid_xml":"https://content.openalex.org/works/W3012536983.grobid-xml"},"referenced_works_count":27,"referenced_works":["https://openalex.org/W1537315613","https://openalex.org/W1604973446","https://openalex.org/W1967804657","https://openalex.org/W1992896217","https://openalex.org/W2001979953","https://openalex.org/W2020898373","https://openalex.org/W2031183907","https://openalex.org/W2055320420","https://openalex.org/W2104227708","https://openalex.org/W2117973232","https://openalex.org/W2140869109","https://openalex.org/W2261066338","https://openalex.org/W2290883490","https://openalex.org/W2347754552","https://openalex.org/W2516542501","https://openalex.org/W2547937424","https://openalex.org/W2626942651","https://openalex.org/W2766934059","https://openalex.org/W2769230810","https://openalex.org/W2864768752","https://openalex.org/W2906059566","https://openalex.org/W2911000641","https://openalex.org/W2912792336","https://openalex.org/W2968765286","https://openalex.org/W4236546113","https://openalex.org/W4244915010","https://openalex.org/W6726578951"],"related_works":["https://openalex.org/W2727311809","https://openalex.org/W2182624400","https://openalex.org/W2767428579","https://openalex.org/W2365800168","https://openalex.org/W1992807692","https://openalex.org/W2078492738","https://openalex.org/W3014549013","https://openalex.org/W2366876790","https://openalex.org/W1971984784","https://openalex.org/W4366203707"],"abstract_inverted_index":{"In":[0,112],"order":[1],"to":[2,142,146],"effectively":[3],"apply":[4],"the":[5,41,50,54,59,62,72,114,135,153,156],"detailed":[6],"geographic":[7],"and":[8,33,69,87,104,124,138,159],"load":[9],"information":[10],"provided":[11],"by":[12],"digital":[13],"technology,":[14],"this":[15,44],"paper":[16,45],"proposes":[17],"a":[18,30,143],"practical":[19,78],"double-Q":[20],"planning":[21],"model":[22,42,125,137,158],"for":[23,39,130],"large-scale":[24,131],"medium":[25,55],"voltage":[26,56],"distribution":[27,57,63,132],"network.":[28,133],"Meanwhile,":[29],"coding":[31],"method":[32],"an":[34],"elite":[35],"Ant-Q":[36],"algorithm(EAQ)":[37],"suitable":[38,129],"solving":[40,126],"in":[43,61,71,149],"are":[46,65,108,128,140],"proposed.":[47],"Based":[48],"on":[49],"basic":[51],"characteristics":[52],"of":[53,77,95,116,155],"network,":[58],"components":[60],"network":[64,102,118],"abstracted":[66],"into":[67,110],"nodes":[68],"branches":[70],"graph":[73],"theory.":[74],"A":[75],"variety":[76],"issue,":[79],"such":[80],"as":[81,98,100],"cost":[82],"parameters":[83],"(investments,":[84],"maintenance,":[85],"reliability)":[86],"technical":[88],"constraints":[89,94,103,107],"(feeder":[90],"capacity":[91],"constraints,":[92],"number":[93],"substation":[96],"feeder),":[97],"well":[99],"road":[101,117],"connection":[105],"mode":[106],"taken":[109],"consideration.":[111],"addition,":[113],"storage":[115],"matrix":[119],"information,":[120],"reliability":[121],"evaluation":[122],"algorithm":[123,127,139],"Finally,":[134],"proposed":[136,157],"applied":[141],"business":[144],"area":[145],"be":[147],"planned":[148],"Guangzhou,":[150],"which":[151],"verifies":[152],"effectiveness":[154],"algorithm.":[160]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":4},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":4},{"year":2022,"cited_by_count":4},{"year":2021,"cited_by_count":5},{"year":2020,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
