{"id":"https://openalex.org/W3006015472","doi":"https://doi.org/10.1109/access.2020.2973816","title":"A Diagnosis of Grounding Grid Corrosion Defects Based on Branch Voltage Disturbance","display_name":"A Diagnosis of Grounding Grid Corrosion Defects Based on Branch Voltage Disturbance","publication_year":2020,"publication_date":"2020-01-01","ids":{"openalex":"https://openalex.org/W3006015472","doi":"https://doi.org/10.1109/access.2020.2973816","mag":"3006015472"},"language":"en","primary_location":{"id":"doi:10.1109/access.2020.2973816","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2020.2973816","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/8948470/08998280.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://ieeexplore.ieee.org/ielx7/6287639/8948470/08998280.pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5103690177","display_name":"Manling Dong","orcid":"https://orcid.org/0000-0002-0191-183X"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Manling Dong","raw_affiliation_strings":["State Grid Henan Electric Power Corporation Research Institute, Zhengzhou, China","ORCiD"],"raw_orcid":"https://orcid.org/0000-0002-0191-183X","affiliations":[{"raw_affiliation_string":"State Grid Henan Electric Power Corporation Research Institute, Zhengzhou, China","institution_ids":[]},{"raw_affiliation_string":"ORCiD","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101576378","display_name":"Zhen Shi","orcid":"https://orcid.org/0000-0001-7164-6819"},"institutions":[{"id":"https://openalex.org/I150807315","display_name":"Guangxi University","ror":"https://ror.org/02c9qn167","country_code":"CN","type":"education","lineage":["https://openalex.org/I150807315"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhen Shi","raw_affiliation_strings":["College of Electrical Engineering, Guangxi University, Nanning, China","ORCiD"],"raw_orcid":"https://orcid.org/0000-0001-7164-6819","affiliations":[{"raw_affiliation_string":"College of Electrical Engineering, Guangxi University, Nanning, China","institution_ids":["https://openalex.org/I150807315"]},{"raw_affiliation_string":"ORCiD","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5114803955","display_name":"Xing Li","orcid":"https://orcid.org/0000-0002-9496-9378"},"institutions":[{"id":"https://openalex.org/I158842170","display_name":"Chongqing University","ror":"https://ror.org/023rhb549","country_code":"CN","type":"education","lineage":["https://openalex.org/I158842170"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xing Li","raw_affiliation_strings":["State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, China","ORCiD"],"raw_orcid":"https://orcid.org/0000-0002-9496-9378","affiliations":[{"raw_affiliation_string":"State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, China","institution_ids":["https://openalex.org/I158842170"]},{"raw_affiliation_string":"ORCiD","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5056774030","display_name":"Guangqi Shao","orcid":"https://orcid.org/0000-0003-2257-8658"},"institutions":[{"id":"https://openalex.org/I150807315","display_name":"Guangxi University","ror":"https://ror.org/02c9qn167","country_code":"CN","type":"education","lineage":["https://openalex.org/I150807315"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Guangqi Shao","raw_affiliation_strings":["College of Electrical Engineering, Guangxi University, Nanning, China","ORCiD"],"raw_orcid":"https://orcid.org/0000-0003-2257-8658","affiliations":[{"raw_affiliation_string":"College of Electrical Engineering, Guangxi University, Nanning, China","institution_ids":["https://openalex.org/I150807315"]},{"raw_affiliation_string":"ORCiD","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5114804153","display_name":"Fan Yang","orcid":"https://orcid.org/0000-0001-7542-1422"},"institutions":[{"id":"https://openalex.org/I158842170","display_name":"Chongqing University","ror":"https://ror.org/023rhb549","country_code":"CN","type":"education","lineage":["https://openalex.org/I158842170"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Fan Yang","raw_affiliation_strings":["State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, China","ORCiD"],"raw_orcid":"https://orcid.org/0000-0001-7542-1422","affiliations":[{"raw_affiliation_string":"State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, China","institution_ids":["https://openalex.org/I158842170"]},{"raw_affiliation_string":"ORCiD","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5102660286","display_name":"Degui Yao","orcid":"https://orcid.org/0000-0001-6432-8003"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Degui Yao","raw_affiliation_strings":["State Grid Henan Electric Power Corporation Research Institute, Zhengzhou, China","ORCiD"],"raw_orcid":"https://orcid.org/0000-0001-6432-8003","affiliations":[{"raw_affiliation_string":"State Grid Henan Electric Power Corporation Research Institute, Zhengzhou, China","institution_ids":[]},{"raw_affiliation_string":"ORCiD","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5114803967","display_name":"Ke Zhang","orcid":"https://orcid.org/0000-0003-4804-7417"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Ke Zhang","raw_affiliation_strings":["State Grid Henan Electric Power Corporation Research Institute, Zhengzhou, China","ORCiD"],"raw_orcid":"https://orcid.org/0000-0003-4804-7417","affiliations":[{"raw_affiliation_string":"State Grid Henan Electric Power Corporation Research Institute, Zhengzhou, China","institution_ids":[]},{"raw_affiliation_string":"ORCiD","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":1850,"currency":"USD","value_usd":1850},"apc_paid":{"value":1850,"currency":"USD","value_usd":1850},"fwci":0.9085,"has_fulltext":true,"cited_by_count":23,"citation_normalized_percentile":{"value":0.73261837,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":"8","issue":null,"first_page":"36749","last_page":"36756"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10787","display_name":"Lightning and Electromagnetic Phenomena","score":0.9958000183105469,"subfield":{"id":"https://openalex.org/subfields/3103","display_name":"Astronomy and Astrophysics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9955000281333923,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ground","display_name":"Ground","score":0.82816481590271},{"id":"https://openalex.org/keywords/disturbance","display_name":"Disturbance (geology)","score":0.6783758401870728},{"id":"https://openalex.org/keywords/corrosion","display_name":"Corrosion","score":0.6540958881378174},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.6229882836341858},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.5884681940078735},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5491249561309814},{"id":"https://openalex.org/keywords/sensitivity","display_name":"Sensitivity (control systems)","score":0.5187421441078186},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.4111831486225128},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.39448022842407227},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.38297921419143677},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.3383311629295349},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.32203567028045654},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.289643794298172},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.2037641704082489},{"id":"https://openalex.org/keywords/geology","display_name":"Geology","score":0.14350023865699768},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.07236772775650024},{"id":"https://openalex.org/keywords/composite-material","display_name":"Composite material","score":0.06615212559700012}],"concepts":[{"id":"https://openalex.org/C168993435","wikidata":"https://www.wikidata.org/wiki/Q6501125","display_name":"Ground","level":2,"score":0.82816481590271},{"id":"https://openalex.org/C2777601987","wikidata":"https://www.wikidata.org/wiki/Q5283581","display_name":"Disturbance (geology)","level":2,"score":0.6783758401870728},{"id":"https://openalex.org/C20625102","wikidata":"https://www.wikidata.org/wiki/Q137056","display_name":"Corrosion","level":2,"score":0.6540958881378174},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.6229882836341858},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5884681940078735},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5491249561309814},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.5187421441078186},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.4111831486225128},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.39448022842407227},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.38297921419143677},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3383311629295349},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.32203567028045654},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.289643794298172},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.2037641704082489},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.14350023865699768},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.07236772775650024},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.06615212559700012},{"id":"https://openalex.org/C151730666","wikidata":"https://www.wikidata.org/wiki/Q7205","display_name":"Paleontology","level":1,"score":0.0},{"id":"https://openalex.org/C13280743","wikidata":"https://www.wikidata.org/wiki/Q131089","display_name":"Geodesy","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/access.2020.2973816","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2020.2973816","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/8948470/08998280.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:1619fe81a49c434885c8357282c3aa05","is_oa":true,"landing_page_url":"https://doaj.org/article/1619fe81a49c434885c8357282c3aa05","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Access, Vol 8, Pp 36749-36756 (2020)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.1109/access.2020.2973816","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2020.2973816","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/8948470/08998280.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G1995200434","display_name":null,"funder_award_id":"5200-201924068A-0-0-00","funder_id":"https://openalex.org/F4320326707","funder_display_name":"State Grid Corporation of China"},{"id":"https://openalex.org/G2722569084","display_name":null,"funder_award_id":"61473272","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G5703351203","display_name":null,"funder_award_id":"51907034","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G721553525","display_name":null,"funder_award_id":"2018JJB160064","funder_id":"https://openalex.org/F4320322768","funder_display_name":"Natural Science Foundation of Guangxi Province"},{"id":"https://openalex.org/G8398677836","display_name":null,"funder_award_id":"2018JJA160176","funder_id":"https://openalex.org/F4320322768","funder_display_name":"Natural Science Foundation of Guangxi Province"},{"id":"https://openalex.org/G8459379121","display_name":"\u9ad8\u538b\u5957\u7ba1\u6cb9\u7eb8\u7edd\u7f18\u52a3\u5316\u7684\u591a\u7ef4\u65f6/\u9891\u57df\u4ecb\u7535\u7279\u5f81\u6307\u7eb9\u8868\u5f81\u53ca\u5176\u591a\u56e0\u7d20\u8026\u5408\u5f71\u54cd\u673a\u7406\u7814\u7a76","funder_award_id":"51867003","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G939203945","display_name":null,"funder_award_id":"2018JJB160056","funder_id":"https://openalex.org/F4320322768","funder_display_name":"Natural Science Foundation of Guangxi Province"}],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"},{"id":"https://openalex.org/F4320322768","display_name":"Natural Science Foundation of Guangxi Province","ror":null},{"id":"https://openalex.org/F4320326707","display_name":"State Grid Corporation of China","ror":"https://ror.org/05twwhs70"},{"id":"https://openalex.org/F4320335967","display_name":"Science and Technology Project of State Grid","ror":null}],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W3006015472.pdf","grobid_xml":"https://content.openalex.org/works/W3006015472.grobid-xml"},"referenced_works_count":27,"referenced_works":["https://openalex.org/W1971363186","https://openalex.org/W1973724078","https://openalex.org/W1987802078","https://openalex.org/W2012319756","https://openalex.org/W2036219076","https://openalex.org/W2050005401","https://openalex.org/W2116942241","https://openalex.org/W2160846719","https://openalex.org/W2171701594","https://openalex.org/W2313609911","https://openalex.org/W2509251148","https://openalex.org/W2511626305","https://openalex.org/W2561255397","https://openalex.org/W2596162239","https://openalex.org/W2604463422","https://openalex.org/W2772554083","https://openalex.org/W2775452455","https://openalex.org/W2780688403","https://openalex.org/W2802066933","https://openalex.org/W2805113305","https://openalex.org/W2907879871","https://openalex.org/W2921922047","https://openalex.org/W2923780625","https://openalex.org/W2948852755","https://openalex.org/W2964454164","https://openalex.org/W2972862101","https://openalex.org/W3005404166"],"related_works":["https://openalex.org/W2349891746","https://openalex.org/W2038604956","https://openalex.org/W2296560746","https://openalex.org/W2338222801","https://openalex.org/W2884282816","https://openalex.org/W2347583731","https://openalex.org/W2394115446","https://openalex.org/W1502342084","https://openalex.org/W2106602008","https://openalex.org/W2067832159"],"abstract_inverted_index":{"The":[0,15],"grounding":[1,16,46,58,99,128,149],"grid":[2,47,59,100,129],"is":[3,49,66,101,112,131,135],"the":[4,8,12,28,40,74,89,98,115,123,127,145,148],"cornerstone":[5],"for":[6,57],"maintaining":[7],"safe":[9],"operation":[10],"of":[11,45,78,91,97,126,147],"power":[13],"system.":[14,41],"network":[17],"acts":[18],"as":[19],"a":[20,104],"concealed":[21],"project,":[22],"and":[23,76,85,114,122],"its":[24],"invisible":[25],"characteristics":[26],"make":[27],"defects":[29],"difficult":[30],"to":[31,94],"be":[32],"detected,":[33],"which":[34,71],"causes":[35],"major":[36],"safety":[37],"hazards":[38],"in":[39,51,68],"Thus":[42],"accurate":[43],"diagnosis":[44,55],"corrosion":[48,60,79,124,146],"vital":[50],"electrical":[52],"engineering.":[53],"A":[54],"method":[56,141],"based":[61,107],"on":[62,108],"branch":[63,81,92,95,109,130],"voltage":[64,82,93,110,120],"disturbance":[65,83,111,121],"proposed":[67],"this":[69,140],"paper,":[70],"can":[72,142],"judge":[73],"location":[75],"degree":[77],"through":[80],"before":[84],"after":[86],"corrosion.":[87],"Firstly,":[88],"sensitivity":[90],"resistance":[96],"analyzed.":[102],"Secondly,":[103],"diagnostic":[105],"model":[106],"established,":[113],"corresponding":[116],"regularity":[117],"between":[118],"peak":[119],"state":[125],"developed.":[132],"Finally,":[133],"it":[134],"verified":[136],"by":[137],"experiments":[138],"that":[139],"effectively":[143],"diagnose":[144],"grid.":[150]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":9},{"year":2024,"cited_by_count":4},{"year":2023,"cited_by_count":3},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":4},{"year":2020,"cited_by_count":1}],"updated_date":"2026-03-27T05:58:40.876381","created_date":"2025-10-10T00:00:00"}