{"id":"https://openalex.org/W3003595421","doi":"https://doi.org/10.1109/access.2020.2970489","title":"A Single-Phase Line-Interactive UPS System for Transformer-Coupled Loading Conditions","display_name":"A Single-Phase Line-Interactive UPS System for Transformer-Coupled Loading Conditions","publication_year":2020,"publication_date":"2020-01-01","ids":{"openalex":"https://openalex.org/W3003595421","doi":"https://doi.org/10.1109/access.2020.2970489","mag":"3003595421"},"language":"en","primary_location":{"id":"doi:10.1109/access.2020.2970489","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2020.2970489","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/8948470/08976140.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://ieeexplore.ieee.org/ielx7/6287639/8948470/08976140.pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5036765061","display_name":"Syed Sabir Hussain Bukhari","orcid":"https://orcid.org/0000-0002-3445-4276"},"institutions":[{"id":"https://openalex.org/I67900169","display_name":"Chung-Ang University","ror":"https://ror.org/01r024a98","country_code":"KR","type":"education","lineage":["https://openalex.org/I67900169"]},{"id":"https://openalex.org/I68288478","display_name":"Sukkur IBA University","ror":"https://ror.org/03e5jvk98","country_code":"PK","type":"education","lineage":["https://openalex.org/I68288478"]}],"countries":["KR","PK"],"is_corresponding":true,"raw_author_name":"Syed Sabir Hussain Bukhari","raw_affiliation_strings":["Department of Electrical Engineering, Sukkur IBA University, Sukkur, Pakistan","School of Electrical and Electronics Engineering, Chung-Ang University, Seoul, South Korea"],"raw_orcid":"https://orcid.org/0000-0002-3445-4276","affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Sukkur IBA University, Sukkur, Pakistan","institution_ids":["https://openalex.org/I68288478"]},{"raw_affiliation_string":"School of Electrical and Electronics Engineering, Chung-Ang University, Seoul, South Korea","institution_ids":["https://openalex.org/I67900169"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5063003835","display_name":"Jong\u2010Suk Ro","orcid":null},"institutions":[{"id":"https://openalex.org/I67900169","display_name":"Chung-Ang University","ror":"https://ror.org/01r024a98","country_code":"KR","type":"education","lineage":["https://openalex.org/I67900169"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Jongsuk Ro","raw_affiliation_strings":["School of Electrical and Electronics Engineering, Chung-Ang University, Seoul, South Korea"],"raw_orcid":"https://orcid.org/0000-0003-4429-9393","affiliations":[{"raw_affiliation_string":"School of Electrical and Electronics Engineering, Chung-Ang University, Seoul, South Korea","institution_ids":["https://openalex.org/I67900169"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5036765061"],"corresponding_institution_ids":["https://openalex.org/I67900169","https://openalex.org/I68288478"],"apc_list":{"value":1850,"currency":"USD","value_usd":1850},"apc_paid":{"value":1850,"currency":"USD","value_usd":1850},"fwci":0.8321,"has_fulltext":true,"cited_by_count":9,"citation_normalized_percentile":{"value":0.71971015,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":97},"biblio":{"volume":"8","issue":null,"first_page":"23143","last_page":"23153"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T13183","display_name":"Islanding Detection in Power Systems","score":0.9970999956130981,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T13183","display_name":"Islanding Detection in Power Systems","score":0.9970999956130981,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9966999888420105,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9962999820709229,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/overcurrent","display_name":"Overcurrent","score":0.7168359160423279},{"id":"https://openalex.org/keywords/uninterruptible-power-supply","display_name":"Uninterruptible power supply","score":0.69752037525177},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.6545540690422058},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5463817119598389},{"id":"https://openalex.org/keywords/current-limiting","display_name":"Current limiting","score":0.4772907793521881},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.4724847674369812},{"id":"https://openalex.org/keywords/isolation-transformer","display_name":"Isolation transformer","score":0.45981675386428833},{"id":"https://openalex.org/keywords/current-transformer","display_name":"Current transformer","score":0.4387786090373993},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.4270049035549164},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.39787057042121887},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.33194148540496826},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3081080913543701},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.24919632077217102}],"concepts":[{"id":"https://openalex.org/C47949032","wikidata":"https://www.wikidata.org/wiki/Q663542","display_name":"Overcurrent","level":3,"score":0.7168359160423279},{"id":"https://openalex.org/C2988808934","wikidata":"https://www.wikidata.org/wiki/Q207696","display_name":"Uninterruptible power supply","level":3,"score":0.69752037525177},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.6545540690422058},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5463817119598389},{"id":"https://openalex.org/C204106720","wikidata":"https://www.wikidata.org/wiki/Q15856134","display_name":"Current limiting","level":3,"score":0.4772907793521881},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.4724847674369812},{"id":"https://openalex.org/C180850520","wikidata":"https://www.wikidata.org/wiki/Q2166404","display_name":"Isolation transformer","level":4,"score":0.45981675386428833},{"id":"https://openalex.org/C133770746","wikidata":"https://www.wikidata.org/wiki/Q856535","display_name":"Current transformer","level":4,"score":0.4387786090373993},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4270049035549164},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.39787057042121887},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.33194148540496826},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3081080913543701},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.24919632077217102},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/access.2020.2970489","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2020.2970489","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/8948470/08976140.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:7d9fd09e4d434847b9a6ad40da46d991","is_oa":true,"landing_page_url":"https://doaj.org/article/7d9fd09e4d434847b9a6ad40da46d991","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Access, Vol 8, Pp 23143-23153 (2020)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.1109/access.2020.2970489","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2020.2970489","pdf_url":"https://ieeexplore.ieee.org/ielx7/6287639/8948470/08976140.pdf","source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"sustainable_development_goals":[{"score":0.5699999928474426,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[{"id":"https://openalex.org/G1095304099","display_name":null,"funder_award_id":"20184030202070","funder_id":"https://openalex.org/F4320335199","funder_display_name":"Korea Institute of Energy Technology Evaluation and Planning"},{"id":"https://openalex.org/G1800672008","display_name":null,"funder_award_id":"20184030202070","funder_id":"https://openalex.org/F4320321681","funder_display_name":"Ministry of Trade, Industry and Energy"},{"id":"https://openalex.org/G3267014211","display_name":null,"funder_award_id":"2019H1D3A1A01102988","funder_id":"https://openalex.org/F4320321681","funder_display_name":"Ministry of Trade, Industry and Energy"},{"id":"https://openalex.org/G3278345378","display_name":null,"funder_award_id":"2016R1D1A1B01008058","funder_id":"https://openalex.org/F4320320671","funder_display_name":"National Research Foundation"},{"id":"https://openalex.org/G6027521432","display_name":null,"funder_award_id":"2016R1D1A1B01008058","funder_id":"https://openalex.org/F4320328359","funder_display_name":"Ministry of Science and ICT, South Korea"},{"id":"https://openalex.org/G8020464497","display_name":null,"funder_award_id":"2019H1D3A1A01102988","funder_id":"https://openalex.org/F4320328359","funder_display_name":"Ministry of Science and ICT, South Korea"},{"id":"https://openalex.org/G8186520223","display_name":null,"funder_award_id":"2019H1D3A1A01102988","funder_id":"https://openalex.org/F4320322120","funder_display_name":"National Research Foundation of Korea"},{"id":"https://openalex.org/G8623180540","display_name":null,"funder_award_id":"2016R1D1A1B01008058","funder_id":"https://openalex.org/F4320322120","funder_display_name":"National Research Foundation of Korea"},{"id":"https://openalex.org/G8966931991","display_name":null,"funder_award_id":"2019H1D3A1A01102988","funder_id":"https://openalex.org/F4320335199","funder_display_name":"Korea Institute of Energy Technology Evaluation and Planning"}],"funders":[{"id":"https://openalex.org/F4320320671","display_name":"National Research Foundation","ror":"https://ror.org/05s0g1g46"},{"id":"https://openalex.org/F4320321681","display_name":"Ministry of Trade, Industry and Energy","ror":"https://ror.org/008nkqk13"},{"id":"https://openalex.org/F4320322120","display_name":"National Research Foundation of Korea","ror":"https://ror.org/013aysd81"},{"id":"https://openalex.org/F4320328359","display_name":"Ministry of Science and ICT, South Korea","ror":"https://ror.org/01wpjm123"},{"id":"https://openalex.org/F4320335199","display_name":"Korea Institute of Energy Technology Evaluation and Planning","ror":"https://ror.org/02zq38y32"}],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W3003595421.pdf","grobid_xml":"https://content.openalex.org/works/W3003595421.grobid-xml"},"referenced_works_count":47,"referenced_works":["https://openalex.org/W1500313741","https://openalex.org/W1600863406","https://openalex.org/W1836674848","https://openalex.org/W1846314226","https://openalex.org/W1909679846","https://openalex.org/W1952804658","https://openalex.org/W2024398437","https://openalex.org/W2052243758","https://openalex.org/W2075092668","https://openalex.org/W2081320601","https://openalex.org/W2097576016","https://openalex.org/W2105205629","https://openalex.org/W2114715867","https://openalex.org/W2116903801","https://openalex.org/W2119871297","https://openalex.org/W2121208070","https://openalex.org/W2123109928","https://openalex.org/W2127255618","https://openalex.org/W2135083634","https://openalex.org/W2135390723","https://openalex.org/W2151334003","https://openalex.org/W2153949303","https://openalex.org/W2154536714","https://openalex.org/W2167913033","https://openalex.org/W2260237744","https://openalex.org/W2297029665","https://openalex.org/W2405967194","https://openalex.org/W2415646268","https://openalex.org/W2488936393","https://openalex.org/W2540024360","https://openalex.org/W2575930669","https://openalex.org/W2588083312","https://openalex.org/W2740430497","https://openalex.org/W2755978866","https://openalex.org/W2792945999","https://openalex.org/W2890452937","https://openalex.org/W2894885106","https://openalex.org/W2898931020","https://openalex.org/W2902943607","https://openalex.org/W2914011142","https://openalex.org/W2946601924","https://openalex.org/W2963208057","https://openalex.org/W2969227774","https://openalex.org/W2972024704","https://openalex.org/W2977288892","https://openalex.org/W2993999966","https://openalex.org/W6763518660"],"related_works":["https://openalex.org/W1497908176","https://openalex.org/W4200517652","https://openalex.org/W2572248349","https://openalex.org/W2038371332","https://openalex.org/W2001390614","https://openalex.org/W2141519932","https://openalex.org/W2366381755","https://openalex.org/W2005785045","https://openalex.org/W2173963361","https://openalex.org/W2369599332"],"abstract_inverted_index":{"A":[0],"line-interactive":[1,40,114,177],"uninterruptible":[2],"power":[3,20,83,96],"supply":[4],"(UPS)":[5],"system":[6,42,116,129,179],"is":[7,88],"one":[8],"of":[9,47,59,81,125,140,174,183],"the":[10,66,72,79,94,126,144,158,175,181,184],"important":[11],"installations":[12],"implemented":[13,135],"by":[14],"industrial":[15,23,86,103],"users":[16],"to":[17,21,92,98,151],"provide":[18],"continuous":[19],"sensitive":[22,85],"applications.":[24],"Such":[25],"loads":[26,87,160],"often":[27],"come":[28],"with":[29],"isolation":[30],"transformers":[31],"for":[32,84,102],"voltage":[33],"matching":[34],"and":[35,97,147,171],"protection":[36],"purposes.":[37],"Hence,":[38],"a":[39,44,112,119,137,154],"UPS":[41,115,128,178],"experiences":[43],"serious":[45],"problem":[46],"transient":[48,61,100],"current":[49,62,101,146],"when":[50],"it":[51,150],"operates":[52],"under":[53,106,168],"transformer-coupled":[54,107,159],"loading":[55,108,172],"conditions.":[56],"The":[57,123],"occurrence":[58],"this":[60],"can":[63],"either":[64],"impair":[65],"apparatus":[67],"itself":[68],"or":[69],"turn":[70],"on":[71,118],"overcurrent":[73],"safety":[74],"devices.":[75],"In":[76],"any":[77],"situation,":[78],"interruption":[80],"electrical":[82],"unavoidable.":[89],"So":[90],"as":[91,157],"keep":[93],"uninterrupted":[95],"eliminate":[99],"applications":[104],"operating":[105,170],"conditions,":[109],"we":[110],"propose":[111],"single-phase":[113,176],"based":[117],"customary":[120],"current-regulated":[121],"inverter.":[122],"inverter":[124],"proposed":[127,185],"employs":[130],"an":[131],"improved":[132],"current-regulating":[133],"scheme":[134],"in":[136],"stationary":[138],"frame":[139],"reference":[141],"which":[142],"regulates":[143],"load":[145],"never":[148],"let":[149],"increase":[152],"than":[153],"prescribed":[155],"value":[156],"are":[161],"turned":[162],"on.":[163],"Laboratory":[164],"test":[165],"results":[166],"obtained":[167],"various":[169],"conditions":[173],"verify":[180],"operation":[182],"system.":[186]},"counts_by_year":[{"year":2023,"cited_by_count":3},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":2},{"year":2018,"cited_by_count":1}],"updated_date":"2026-05-06T08:25:59.206177","created_date":"2025-10-10T00:00:00"}
