{"id":"https://openalex.org/W2979605361","doi":"https://doi.org/10.1109/access.2019.2945990","title":"Hybrid Photovoltaic-Thermoelectric Generator Powered Synchronous Reluctance Motor for Pumping Applications","display_name":"Hybrid Photovoltaic-Thermoelectric Generator Powered Synchronous Reluctance Motor for Pumping Applications","publication_year":2019,"publication_date":"2019-01-01","ids":{"openalex":"https://openalex.org/W2979605361","doi":"https://doi.org/10.1109/access.2019.2945990","mag":"2979605361"},"language":"en","primary_location":{"id":"doi:10.1109/access.2019.2945990","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2019.2945990","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://doi.org/10.1109/access.2019.2945990","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5064433185","display_name":"Mohamed N. Ibrahim","orcid":"https://orcid.org/0000-0002-4087-3792"},"institutions":[{"id":"https://openalex.org/I32597200","display_name":"Ghent University","ror":"https://ror.org/00cv9y106","country_code":"BE","type":"education","lineage":["https://openalex.org/I32597200"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"Mohamed N. Ibrahim","raw_affiliation_strings":["Department of Electrical Energy, Metals, Mechanical Constructions and Systems, Ghent University, Ghent, Belgium"],"raw_orcid":"https://orcid.org/0000-0002-4087-3792","affiliations":[{"raw_affiliation_string":"Department of Electrical Energy, Metals, Mechanical Constructions and Systems, Ghent University, Ghent, Belgium","institution_ids":["https://openalex.org/I32597200"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5086816810","display_name":"Hegazy Rezk","orcid":"https://orcid.org/0000-0001-9254-2744"},"institutions":[{"id":"https://openalex.org/I89466785","display_name":"Minia University","ror":"https://ror.org/02hcv4z63","country_code":"EG","type":"education","lineage":["https://openalex.org/I89466785"]}],"countries":["EG"],"is_corresponding":false,"raw_author_name":"Hegazy Rezk","raw_affiliation_strings":["Electrical Engineering Department, Minia University, Minia, Egypt"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical Engineering Department, Minia University, Minia, Egypt","institution_ids":["https://openalex.org/I89466785"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5108694194","display_name":"Mujahed Al-Dahifallah","orcid":null},"institutions":[{"id":"https://openalex.org/I134085113","display_name":"King Fahd University of Petroleum and Minerals","ror":"https://ror.org/03yez3163","country_code":"SA","type":"education","lineage":["https://openalex.org/I134085113"]}],"countries":["SA"],"is_corresponding":false,"raw_author_name":"Mujahed Al-Dahifallah","raw_affiliation_strings":["Systems Engineering Department, King Fahd University of Petroleum and Minerals, Dhahran, Saudi Arabia"],"raw_orcid":"https://orcid.org/0000-0002-8441-2146","affiliations":[{"raw_affiliation_string":"Systems Engineering Department, King Fahd University of Petroleum and Minerals, Dhahran, Saudi Arabia","institution_ids":["https://openalex.org/I134085113"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5085931627","display_name":"Peter Sergeant","orcid":"https://orcid.org/0000-0001-8601-7839"},"institutions":[{"id":"https://openalex.org/I32597200","display_name":"Ghent University","ror":"https://ror.org/00cv9y106","country_code":"BE","type":"education","lineage":["https://openalex.org/I32597200"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"Peter Sergeant","raw_affiliation_strings":["Department of Electrical Energy, Metals, Mechanical Constructions and Systems, Ghent University, Ghent, Belgium"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Energy, Metals, Mechanical Constructions and Systems, Ghent University, Ghent, Belgium","institution_ids":["https://openalex.org/I32597200"]}]}],"institutions":[],"countries_distinct_count":3,"institutions_distinct_count":4,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":1850,"currency":"USD","value_usd":1850},"apc_paid":{"value":1850,"currency":"USD","value_usd":1850},"fwci":1.2425,"has_fulltext":false,"cited_by_count":36,"citation_normalized_percentile":{"value":0.77576775,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":95,"max":99},"biblio":{"volume":"7","issue":null,"first_page":"146979","last_page":"146988"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10468","display_name":"Photovoltaic System Optimization Techniques","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10468","display_name":"Photovoltaic System Optimization Techniques","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11007","display_name":"Hybrid Renewable Energy Systems","score":0.9945999979972839,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10905","display_name":"Solar Thermal and Photovoltaic Systems","score":0.9921000003814697,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/thermoelectric-generator","display_name":"Thermoelectric generator","score":0.633307933807373},{"id":"https://openalex.org/keywords/switched-reluctance-motor","display_name":"Switched reluctance motor","score":0.6288212537765503},{"id":"https://openalex.org/keywords/photovoltaic-system","display_name":"Photovoltaic system","score":0.6030265092849731},{"id":"https://openalex.org/keywords/magnetic-reluctance","display_name":"Magnetic reluctance","score":0.5580503940582275},{"id":"https://openalex.org/keywords/reluctance-motor","display_name":"Reluctance motor","score":0.542233943939209},{"id":"https://openalex.org/keywords/synchronous-motor","display_name":"Synchronous motor","score":0.4940078854560852},{"id":"https://openalex.org/keywords/generator","display_name":"Generator (circuit theory)","score":0.4915224015712738},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4347038269042969},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.4250989258289337},{"id":"https://openalex.org/keywords/permanent-magnet-synchronous-generator","display_name":"Permanent magnet synchronous generator","score":0.42453712224960327},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.42361077666282654},{"id":"https://openalex.org/keywords/thermoelectric-effect","display_name":"Thermoelectric effect","score":0.4118032455444336},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.1803569197654724},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.1711447834968567},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.1676385998725891},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.0854426920413971},{"id":"https://openalex.org/keywords/rotor","display_name":"Rotor (electric)","score":0.07500147819519043},{"id":"https://openalex.org/keywords/magnet","display_name":"Magnet","score":0.0642140805721283}],"concepts":[{"id":"https://openalex.org/C117127486","wikidata":"https://www.wikidata.org/wiki/Q11569191","display_name":"Thermoelectric generator","level":3,"score":0.633307933807373},{"id":"https://openalex.org/C12090584","wikidata":"https://www.wikidata.org/wiki/Q4107232","display_name":"Switched reluctance motor","level":3,"score":0.6288212537765503},{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.6030265092849731},{"id":"https://openalex.org/C197993065","wikidata":"https://www.wikidata.org/wiki/Q863390","display_name":"Magnetic reluctance","level":3,"score":0.5580503940582275},{"id":"https://openalex.org/C90172651","wikidata":"https://www.wikidata.org/wiki/Q2142883","display_name":"Reluctance motor","level":4,"score":0.542233943939209},{"id":"https://openalex.org/C71376005","wikidata":"https://www.wikidata.org/wiki/Q845675","display_name":"Synchronous motor","level":2,"score":0.4940078854560852},{"id":"https://openalex.org/C2780992000","wikidata":"https://www.wikidata.org/wiki/Q17016113","display_name":"Generator (circuit theory)","level":3,"score":0.4915224015712738},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4347038269042969},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4250989258289337},{"id":"https://openalex.org/C201320609","wikidata":"https://www.wikidata.org/wiki/Q3274420","display_name":"Permanent magnet synchronous generator","level":3,"score":0.42453712224960327},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.42361077666282654},{"id":"https://openalex.org/C63024428","wikidata":"https://www.wikidata.org/wiki/Q552456","display_name":"Thermoelectric effect","level":2,"score":0.4118032455444336},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.1803569197654724},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.1711447834968567},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.1676385998725891},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0854426920413971},{"id":"https://openalex.org/C17281054","wikidata":"https://www.wikidata.org/wiki/Q193466","display_name":"Rotor (electric)","level":2,"score":0.07500147819519043},{"id":"https://openalex.org/C16389437","wikidata":"https://www.wikidata.org/wiki/Q11421","display_name":"Magnet","level":2,"score":0.0642140805721283},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1109/access.2019.2945990","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2019.2945990","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},{"id":"pmh:oai:archive.ugent.be:8632949","is_oa":true,"landing_page_url":"http://hdl.handle.net/1854/LU-8632949","pdf_url":null,"source":{"id":"https://openalex.org/S4306400478","display_name":"Ghent University Academic Bibliography (Ghent University)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I32597200","host_organization_name":"Ghent University","host_organization_lineage":["https://openalex.org/I32597200"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"ISSN: 2169-3536","raw_type":"info:eu-repo/semantics/publishedVersion"},{"id":"pmh:oai:doaj.org/article:177bb3b128cc4ba9ad2a11a3b5d39542","is_oa":true,"landing_page_url":"https://doaj.org/article/177bb3b128cc4ba9ad2a11a3b5d39542","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Access, Vol 7, Pp 146979-146988 (2019)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.1109/access.2019.2945990","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2019.2945990","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.6000000238418579}],"awards":[],"funders":[{"id":"https://openalex.org/F4320322323","display_name":"King Fahd University of Petroleum and Minerals","ror":"https://ror.org/03yez3163"},{"id":"https://openalex.org/F4320322603","display_name":"Universiteit Gent","ror":"https://ror.org/00cv9y106"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":23,"referenced_works":["https://openalex.org/W638084065","https://openalex.org/W1242819450","https://openalex.org/W1794337152","https://openalex.org/W1971465990","https://openalex.org/W1972288659","https://openalex.org/W2021006451","https://openalex.org/W2033950133","https://openalex.org/W2055793425","https://openalex.org/W2080978846","https://openalex.org/W2091493242","https://openalex.org/W2119760459","https://openalex.org/W2130715736","https://openalex.org/W2134241280","https://openalex.org/W2292474796","https://openalex.org/W2415704035","https://openalex.org/W2499113799","https://openalex.org/W2529569391","https://openalex.org/W2607767440","https://openalex.org/W2735411314","https://openalex.org/W2758253446","https://openalex.org/W2772925746","https://openalex.org/W2885331409","https://openalex.org/W2951596082"],"related_works":["https://openalex.org/W2898226232","https://openalex.org/W3215329723","https://openalex.org/W2559094042","https://openalex.org/W2359982076","https://openalex.org/W2061566850","https://openalex.org/W2965609695","https://openalex.org/W2388180642","https://openalex.org/W2116720091","https://openalex.org/W2781252968","https://openalex.org/W2119992074"],"abstract_inverted_index":{"The":[0,56],"interest":[1],"in":[2,10,117],"photovoltaic":[3,47],"(PV)":[4],"pumping":[5,54],"systems":[6],"has":[7],"increased,":[8],"particularly":[9],"rural":[11],"areas":[12],"where":[13],"there":[14],"is":[15,51,73,114,139,164],"no":[16],"grid":[17],"supply":[18],"available.":[19],"However,":[20],"both":[21],"the":[22,25,28,71,82,96,100,110,118,142,147,160,173,179,193],"performance":[23],"and":[24,64,93,130,146,156,176],"cost":[26,175],"of":[27,39,99,178,196],"whole":[29],"system":[30,102,180],"are":[31,124,134,151,181,189],"still":[32],"an":[33,65,185],"obstacle":[34],"for":[35,53,70],"a":[36,45,60,87],"wide":[37],"spread":[38],"this":[40,43,197],"technology.":[41],"In":[42],"article,":[44],"hybrid":[46,161],"(PV)-thermoelectric":[48],"generator":[49],"(TEG)":[50],"investigated":[52],"applications.":[55],"electric":[57],"drivetrain":[58,72],"comprises":[59],"synchronous":[61],"reluctance":[62],"motor":[63,83,143],"inverter.":[66],"A":[67],"control":[68],"strategy":[69],"employed":[74],"to":[75,85,167,191],"execute":[76],"two":[77],"main":[78],"tasks:":[79],"1)":[80],"driving":[81],"properly":[84],"achieve":[86],"maximum":[88],"torque":[89],"per":[90],"Amp\u00e8re":[91],"condition":[92],"2)":[94],"maximizing":[95],"output":[97,144],"power":[98,145],"PV":[101,170],"at":[103],"different":[104],"weather":[105],"conditions.":[106],"This":[107],"means":[108],"that":[109,141],"conventional":[111],"DC-DC":[112],"converter":[113],"not":[115,136],"used":[116,165],"proposed":[119],"system.":[120],"Moreover,":[121],"batteries,":[122],"which":[123],"characterized":[125],"by":[126,153],"short":[127],"life":[128],"expectancy":[129],"high":[131],"replacement":[132],"cost,":[133],"also":[135],"used.":[137],"It":[138],"found":[140],"pump":[148],"flow":[149],"rate":[150],"increased":[152],"about":[154],"9.5%":[155],"12%":[157],"respectively":[158],"when":[159],"PV-TEG":[162],"array":[163],"compared":[166],"only":[168],"using":[169],"array.":[171],"Accordingly,":[172],"performance,":[174],"complexity":[177],"improved.":[182],"Measurements":[183],"on":[184],"experimental":[186],"laboratory":[187],"setup":[188],"constructed":[190],"validate":[192],"theoretical":[194],"results":[195],"work.":[198]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":6},{"year":2023,"cited_by_count":7},{"year":2022,"cited_by_count":6},{"year":2021,"cited_by_count":8},{"year":2020,"cited_by_count":7}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
