{"id":"https://openalex.org/W2781601434","doi":"https://doi.org/10.1109/access.2017.2788893","title":"Optimal Allocation of Fire Extinguishing Equipment for a Power Grid Under Widespread Fire Disasters","display_name":"Optimal Allocation of Fire Extinguishing Equipment for a Power Grid Under Widespread Fire Disasters","publication_year":2018,"publication_date":"2018-01-01","ids":{"openalex":"https://openalex.org/W2781601434","doi":"https://doi.org/10.1109/access.2017.2788893","mag":"2781601434"},"language":"en","primary_location":{"id":"doi:10.1109/access.2017.2788893","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2017.2788893","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://doi.org/10.1109/access.2017.2788893","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5103213346","display_name":"Jiazheng Lu","orcid":"https://orcid.org/0000-0002-9601-1841"},"institutions":[{"id":"https://openalex.org/I4210122501","display_name":"Hunan Xiangdian Test Research Institute (China)","ror":"https://ror.org/0391pty66","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210122501"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Jiazheng Lu","raw_affiliation_strings":["State Key Laboratory of Disaster Prevention and Reduction for Power Grid Transmission and Distribution Equipment, State Grid Hunan Electric Company Disaster Prevention and Reduction Center, Changsha, China"],"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Disaster Prevention and Reduction for Power Grid Transmission and Distribution Equipment, State Grid Hunan Electric Company Disaster Prevention and Reduction Center, Changsha, China","institution_ids":["https://openalex.org/I4210122501"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100445479","display_name":"Jun Guo","orcid":"https://orcid.org/0000-0003-1737-8344"},"institutions":[{"id":"https://openalex.org/I4210122501","display_name":"Hunan Xiangdian Test Research Institute (China)","ror":"https://ror.org/0391pty66","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210122501"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jun Guo","raw_affiliation_strings":["State Key Laboratory of Disaster Prevention and Reduction for Power Grid Transmission and Distribution Equipment, State Grid Hunan Electric Company Disaster Prevention and Reduction Center, Changsha, China"],"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Disaster Prevention and Reduction for Power Grid Transmission and Distribution Equipment, State Grid Hunan Electric Company Disaster Prevention and Reduction Center, Changsha, China","institution_ids":["https://openalex.org/I4210122501"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101411613","display_name":"Zhou Jian","orcid":"https://orcid.org/0000-0003-3641-8399"},"institutions":[{"id":"https://openalex.org/I4210122501","display_name":"Hunan Xiangdian Test Research Institute (China)","ror":"https://ror.org/0391pty66","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210122501"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhou Jian","raw_affiliation_strings":["State Key Laboratory of Disaster Prevention and Reduction for Power Grid Transmission and Distribution Equipment, State Grid Hunan Electric Company Disaster Prevention and Reduction Center, Changsha, China"],"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Disaster Prevention and Reduction for Power Grid Transmission and Distribution Equipment, State Grid Hunan Electric Company Disaster Prevention and Reduction Center, Changsha, China","institution_ids":["https://openalex.org/I4210122501"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5068210435","display_name":"Xunjian Xu","orcid":null},"institutions":[{"id":"https://openalex.org/I4210122501","display_name":"Hunan Xiangdian Test Research Institute (China)","ror":"https://ror.org/0391pty66","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210122501"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xunjian Xu","raw_affiliation_strings":["State Key Laboratory of Disaster Prevention and Reduction for Power Grid Transmission and Distribution Equipment, State Grid Hunan Electric Company Disaster Prevention and Reduction Center, Changsha, China"],"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Disaster Prevention and Reduction for Power Grid Transmission and Distribution Equipment, State Grid Hunan Electric Company Disaster Prevention and Reduction Center, Changsha, China","institution_ids":["https://openalex.org/I4210122501"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5103213346"],"corresponding_institution_ids":["https://openalex.org/I4210122501"],"apc_list":{"value":1850,"currency":"USD","value_usd":1850},"apc_paid":{"value":1850,"currency":"USD","value_usd":1850},"fwci":2.0194,"has_fulltext":false,"cited_by_count":28,"citation_normalized_percentile":{"value":0.8459662,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":95,"max":99},"biblio":{"volume":"6","issue":null,"first_page":"6382","last_page":"6389"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11807","display_name":"Infrastructure Resilience and Vulnerability Analysis","score":0.9890999794006348,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11807","display_name":"Infrastructure Resilience and Vulnerability Analysis","score":0.9890999794006348,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11317","display_name":"Fire dynamics and safety research","score":0.9887999892234802,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9815000295639038,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.6289443969726562},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6144163608551025},{"id":"https://openalex.org/keywords/electric-power-transmission","display_name":"Electric power transmission","score":0.5698788166046143},{"id":"https://openalex.org/keywords/tripping","display_name":"Tripping","score":0.5436332821846008},{"id":"https://openalex.org/keywords/power-grid","display_name":"Power grid","score":0.47843578457832336},{"id":"https://openalex.org/keywords/fire-protection","display_name":"Fire protection","score":0.4773388206958771},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.43994519114494324},{"id":"https://openalex.org/keywords/range","display_name":"Range (aeronautics)","score":0.4311107397079468},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.4169308841228485},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.3765982985496521},{"id":"https://openalex.org/keywords/computer-security","display_name":"Computer security","score":0.3333730697631836},{"id":"https://openalex.org/keywords/operations-research","display_name":"Operations research","score":0.3263680934906006},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.18153876066207886},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.16209515929222107},{"id":"https://openalex.org/keywords/civil-engineering","display_name":"Civil engineering","score":0.13875475525856018},{"id":"https://openalex.org/keywords/circuit-breaker","display_name":"Circuit breaker","score":0.12829944491386414},{"id":"https://openalex.org/keywords/geography","display_name":"Geography","score":0.09767481684684753}],"concepts":[{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.6289443969726562},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6144163608551025},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.5698788166046143},{"id":"https://openalex.org/C2779733308","wikidata":"https://www.wikidata.org/wiki/Q17146464","display_name":"Tripping","level":3,"score":0.5436332821846008},{"id":"https://openalex.org/C2983254600","wikidata":"https://www.wikidata.org/wiki/Q1096907","display_name":"Power grid","level":3,"score":0.47843578457832336},{"id":"https://openalex.org/C122156500","wikidata":"https://www.wikidata.org/wiki/Q41399","display_name":"Fire protection","level":2,"score":0.4773388206958771},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.43994519114494324},{"id":"https://openalex.org/C204323151","wikidata":"https://www.wikidata.org/wiki/Q905424","display_name":"Range (aeronautics)","level":2,"score":0.4311107397079468},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.4169308841228485},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3765982985496521},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.3333730697631836},{"id":"https://openalex.org/C42475967","wikidata":"https://www.wikidata.org/wiki/Q194292","display_name":"Operations research","level":1,"score":0.3263680934906006},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.18153876066207886},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.16209515929222107},{"id":"https://openalex.org/C147176958","wikidata":"https://www.wikidata.org/wiki/Q77590","display_name":"Civil engineering","level":1,"score":0.13875475525856018},{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.12829944491386414},{"id":"https://openalex.org/C205649164","wikidata":"https://www.wikidata.org/wiki/Q1071","display_name":"Geography","level":0,"score":0.09767481684684753},{"id":"https://openalex.org/C13280743","wikidata":"https://www.wikidata.org/wiki/Q131089","display_name":"Geodesy","level":1,"score":0.0},{"id":"https://openalex.org/C146978453","wikidata":"https://www.wikidata.org/wiki/Q3798668","display_name":"Aerospace engineering","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/access.2017.2788893","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2017.2788893","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:697822015ab642819232519896b05b03","is_oa":true,"landing_page_url":"https://doaj.org/article/697822015ab642819232519896b05b03","pdf_url":null,"source":{"id":"https://openalex.org/S112646816","display_name":"SHILAP Revista de lepidopterolog\u00eda","issn_l":"0300-5267","issn":["0300-5267","2340-4078"],"is_oa":true,"is_in_doaj":true,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Access, Vol 6, Pp 6382-6389 (2018)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.1109/access.2017.2788893","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2017.2788893","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"sustainable_development_goals":[{"score":0.7599999904632568,"id":"https://metadata.un.org/sdg/13","display_name":"Climate action"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":9,"referenced_works":["https://openalex.org/W2075028659","https://openalex.org/W2115894864","https://openalex.org/W2126043700","https://openalex.org/W2150738367","https://openalex.org/W2356300970","https://openalex.org/W2373612569","https://openalex.org/W2376471461","https://openalex.org/W2554529300","https://openalex.org/W2565993559"],"related_works":["https://openalex.org/W2052282468","https://openalex.org/W2051639166","https://openalex.org/W2372607241","https://openalex.org/W1485498677","https://openalex.org/W2256564961","https://openalex.org/W2238685368","https://openalex.org/W2385546206","https://openalex.org/W2357247767","https://openalex.org/W2373263525","https://openalex.org/W2371597700"],"abstract_inverted_index":{"Widespread":[0],"fire":[1,14,56,72,106,127,174],"disasters":[2,15],"always":[3],"occur":[4],"in":[5,112,135,166],"several":[6],"concentrated":[7],"short":[8],"periods.":[9],"A":[10],"large":[11,66],"range":[12],"of":[13,20,22,33,39,52,55,64,84,118,151,204],"can":[16,153,195],"cause":[17],"the":[18,34,50,53,62,103,119,124,136,149,164,185,205],"tripping":[19],"dozens":[21],"transmission":[23,85,169],"lines":[24,170],"simultaneously,":[25],"posing":[26],"a":[27,65,79,142],"serious":[28],"threat":[29],"to":[30,48,99,102,114,156],"safe":[31],"operation":[32],"power":[35,69,96,139,207],"grid.":[36,208],"The":[37,88,130,145],"degree":[38],"risk":[40,89],"cannot":[41],"be":[42,110,154],"efficiently":[43],"calculated,":[44],"making":[45],"it":[46],"difficult":[47],"guide":[49],"optimization":[51],"allocation":[54,76],"extinguishing":[57,73,107,128],"equipment.":[58],"This":[59,193],"paper":[60],"describes":[61],"development":[63],"wildfire":[67],"disaster":[68,202],"grid":[70,104,120,140],"fault":[71],"equipment":[74,108,126],"optimal":[75],"method":[77,83,132],"and":[78,198],"proposed":[80,131],"fast":[81],"calculation":[82,186],"line":[86],"risk.":[87],"index":[90],"is":[91,133,188],"calculated":[92],"for":[93,163,201],"different":[94],"regional":[95],"grids":[97],"according":[98],"subareas.":[100],"According":[101],"risk,":[105],"will":[109],"deployed":[111],"advance":[113],"address":[115],"high-risk":[116],"areas":[117],"fire,":[121],"fully":[122],"exploiting":[123],"limited":[125],"effectiveness.":[129],"verified":[134],"Hunan":[137],"provincial":[138],"as":[141],"case":[143,165],"study.":[144],"results":[146],"show":[147],"that":[148],"number":[150],"calculations":[152],"reduced":[155],"1.2":[157],"\u00d7":[158],"10":[159],"<sup":[160],"xmlns:mml=\"http://www.w3.org/1998/Math/MathML\"":[161],"xmlns:xlink=\"http://www.w3.org/1999/xlink\">3</sup>":[162],"which":[167],"20":[168],"are":[171],"threatened":[172],"by":[173],"disasters;":[175],"using":[176],"computer":[177],"resources":[178],"with":[179],"30":[180],"trillion":[181],"operations":[182],"per":[183],"second,":[184],"time":[187],"less":[189],"than":[190],"5":[191],"min.":[192],"capability":[194],"provide":[196],"scientific":[197],"efficient":[199],"guidance":[200],"treatment":[203],"electric":[206]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":6},{"year":2024,"cited_by_count":6},{"year":2023,"cited_by_count":3},{"year":2022,"cited_by_count":3},{"year":2021,"cited_by_count":3},{"year":2020,"cited_by_count":3},{"year":2019,"cited_by_count":3}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}