{"id":"https://openalex.org/W2625161879","doi":"https://doi.org/10.1109/access.2017.2715239","title":"Optimizing HVAC Energy Usage in Industrial Processes by Scheduling Based on Weather Data","display_name":"Optimizing HVAC Energy Usage in Industrial Processes by Scheduling Based on Weather Data","publication_year":2017,"publication_date":"2017-01-01","ids":{"openalex":"https://openalex.org/W2625161879","doi":"https://doi.org/10.1109/access.2017.2715239","mag":"2625161879"},"language":"en","primary_location":{"id":"doi:10.1109/access.2017.2715239","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2017.2715239","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://doi.org/10.1109/access.2017.2715239","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5033319067","display_name":"Kashif Hesham Khan","orcid":"https://orcid.org/0000-0002-6529-6725"},"institutions":[{"id":"https://openalex.org/I1320473756","display_name":"The Royal Melbourne Hospital","ror":"https://ror.org/005bvs909","country_code":"AU","type":"funder","lineage":["https://openalex.org/I1320473756","https://openalex.org/I4210158168"]}],"countries":["AU"],"is_corresponding":false,"raw_author_name":"Kashif Hesham Khan","raw_affiliation_strings":["Royal Melbourne Institute of Technology, Melbourne, VIC, Australia"],"raw_orcid":"https://orcid.org/0000-0002-6529-6725","affiliations":[{"raw_affiliation_string":"Royal Melbourne Institute of Technology, Melbourne, VIC, Australia","institution_ids":["https://openalex.org/I1320473756"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5000983360","display_name":"Caspar Ryan","orcid":"https://orcid.org/0000-0002-5569-6012"},"institutions":[{"id":"https://openalex.org/I1320473756","display_name":"The Royal Melbourne Hospital","ror":"https://ror.org/005bvs909","country_code":"AU","type":"funder","lineage":["https://openalex.org/I1320473756","https://openalex.org/I4210158168"]}],"countries":["AU"],"is_corresponding":false,"raw_author_name":"Caspar Ryan","raw_affiliation_strings":["Royal Melbourne Institute of Technology, Melbourne, VIC, Australia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Royal Melbourne Institute of Technology, Melbourne, VIC, Australia","institution_ids":["https://openalex.org/I1320473756"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5005140412","display_name":"Ermyas Abebe","orcid":null},"institutions":[{"id":"https://openalex.org/I4210120068","display_name":"IBM Research - Australia","ror":"https://ror.org/027r3nx49","country_code":"AU","type":"facility","lineage":["https://openalex.org/I1341412227","https://openalex.org/I4210114115","https://openalex.org/I4210120068"]}],"countries":["AU"],"is_corresponding":false,"raw_author_name":"Ermyas Abebe","raw_affiliation_strings":["IBM Australia, Carlton, VIC, Australia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"IBM Australia, Carlton, VIC, Australia","institution_ids":["https://openalex.org/I4210120068"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":1850,"currency":"USD","value_usd":1850},"apc_paid":{"value":1850,"currency":"USD","value_usd":1850},"fwci":3.1713,"has_fulltext":false,"cited_by_count":26,"citation_normalized_percentile":{"value":0.90886859,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":90,"max":99},"biblio":{"volume":"5","issue":null,"first_page":"11228","last_page":"11235"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9976999759674072,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11954","display_name":"Energy Efficiency and Management","score":0.9898999929428101,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hvac","display_name":"HVAC","score":0.9653010368347168},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.7155674695968628},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6433653831481934},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"Air conditioning","score":0.6231793761253357},{"id":"https://openalex.org/keywords/schedule","display_name":"Schedule","score":0.593765914440155},{"id":"https://openalex.org/keywords/scheduling","display_name":"Scheduling (production processes)","score":0.5678385496139526},{"id":"https://openalex.org/keywords/integer-programming","display_name":"Integer programming","score":0.5171563029289246},{"id":"https://openalex.org/keywords/ventilation","display_name":"Ventilation (architecture)","score":0.49953675270080566},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.4784412682056427},{"id":"https://openalex.org/keywords/environmental-science","display_name":"Environmental science","score":0.3565523624420166},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.34987300634384155},{"id":"https://openalex.org/keywords/mathematical-optimization","display_name":"Mathematical optimization","score":0.24378535151481628},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.20504581928253174},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.10806754231452942},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.09401249885559082},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.06781479716300964}],"concepts":[{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.9653010368347168},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.7155674695968628},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6433653831481934},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.6231793761253357},{"id":"https://openalex.org/C68387754","wikidata":"https://www.wikidata.org/wiki/Q7271585","display_name":"Schedule","level":2,"score":0.593765914440155},{"id":"https://openalex.org/C206729178","wikidata":"https://www.wikidata.org/wiki/Q2271896","display_name":"Scheduling (production processes)","level":2,"score":0.5678385496139526},{"id":"https://openalex.org/C56086750","wikidata":"https://www.wikidata.org/wiki/Q6042592","display_name":"Integer programming","level":2,"score":0.5171563029289246},{"id":"https://openalex.org/C200457457","wikidata":"https://www.wikidata.org/wiki/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.49953675270080566},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.4784412682056427},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.3565523624420166},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.34987300634384155},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.24378535151481628},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.20504581928253174},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.10806754231452942},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.09401249885559082},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.06781479716300964},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.0}],"mesh":[],"locations_count":6,"locations":[{"id":"doi:10.1109/access.2017.2715239","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2017.2715239","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},{"id":"pmh:oai:alma.61RMIT_INST:11246736160001341","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ACCESS.2017.2715239","pdf_url":null,"source":{"id":"https://openalex.org/S4306402074","display_name":"RMIT Research Repository (RMIT University Library)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I82951845","host_organization_name":"RMIT University","host_organization_lineage":["https://openalex.org/I82951845"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"text"},{"id":"pmh:oai:doaj.org/article:939fcc3ef52d4801a71eaa434c2af752","is_oa":true,"landing_page_url":"https://doaj.org/article/939fcc3ef52d4801a71eaa434c2af752","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Access, Vol 5, Pp 11228-11235 (2017)","raw_type":"article"},{"id":"pmh:oai:dro.deakin.edu.au:DU:30166521","is_oa":false,"landing_page_url":null,"pdf_url":null,"source":{"id":"https://openalex.org/S4306401102","display_name":"Own your potential (DEAKIN)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I149704539","host_organization_name":"Deakin University","host_organization_lineage":["https://openalex.org/I149704539"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"Journal Article"},{"id":"pmh:oai:figshare.com:article/20608470","is_oa":true,"landing_page_url":"https://figshare.com/articles/journal_contribution/Optimizing_HVAC_Energy_Usage_in_Industrial_Processes_by_Scheduling_Based_on_Weather_Data/20608470","pdf_url":null,"source":{"id":"https://openalex.org/S4377196282","display_name":"Figshare","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4210132348","host_organization_name":"Figshare (United Kingdom)","host_organization_lineage":["https://openalex.org/I4210132348"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Text"},{"id":"pmh:oai:figshare.com:article/27504825","is_oa":true,"landing_page_url":"https://figshare.com/articles/journal_contribution/Optimizing_HVAC_energy_usage_in_industrial_processes_by_scheduling_based_on_weather_data/27504825","pdf_url":null,"source":{"id":"https://openalex.org/S4377196282","display_name":"Figshare","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4210132348","host_organization_name":"Figshare (United Kingdom)","host_organization_lineage":["https://openalex.org/I4210132348"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Text"}],"best_oa_location":{"id":"doi:10.1109/access.2017.2715239","is_oa":true,"landing_page_url":"https://doi.org/10.1109/access.2017.2715239","pdf_url":null,"source":{"id":"https://openalex.org/S2485537415","display_name":"IEEE Access","issn_l":"2169-3536","issn":["2169-3536"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Access","raw_type":"journal-article"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.8999999761581421}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":32,"referenced_works":["https://openalex.org/W572085233","https://openalex.org/W1583339069","https://openalex.org/W1966814098","https://openalex.org/W1968524480","https://openalex.org/W1975404935","https://openalex.org/W1976981503","https://openalex.org/W2001960389","https://openalex.org/W2030582429","https://openalex.org/W2034810256","https://openalex.org/W2036920508","https://openalex.org/W2041279153","https://openalex.org/W2041701590","https://openalex.org/W2043572767","https://openalex.org/W2054376004","https://openalex.org/W2061434834","https://openalex.org/W2078940037","https://openalex.org/W2092792488","https://openalex.org/W2107303585","https://openalex.org/W2131414398","https://openalex.org/W2148158851","https://openalex.org/W2164639462","https://openalex.org/W2166313543","https://openalex.org/W2303448516","https://openalex.org/W2336598650","https://openalex.org/W2460347009","https://openalex.org/W2531561353","https://openalex.org/W2994193126","https://openalex.org/W4255976119","https://openalex.org/W4285719527","https://openalex.org/W6634855459","https://openalex.org/W6728459563","https://openalex.org/W6771488179"],"related_works":["https://openalex.org/W2112866972","https://openalex.org/W4240233711","https://openalex.org/W2900606913","https://openalex.org/W4320003279","https://openalex.org/W2326910963","https://openalex.org/W3046823714","https://openalex.org/W2348218441","https://openalex.org/W3021806226","https://openalex.org/W4205684936","https://openalex.org/W4281297310"],"abstract_inverted_index":{"Industrial":[0],"buildings":[1],"are":[2,27],"demonstrating":[3],"increasing":[4],"rates":[5],"of":[6,20,39],"energy":[7,25,59,84,92],"consumption,":[8],"with":[9],"heating,":[10],"ventilation,":[11],"and":[12,41,55],"air":[13],"conditioning":[14],"(HVAC)":[15],"typically":[16],"constituting":[17],"over":[18,52],"50%":[19],"this":[21,62],"consumption.":[22],"However,":[23],"these":[24],"requirements":[26],"heavily":[28],"influenced":[29],"by":[30,86,97],"weather":[31,79],"conditions":[32],"based":[33,77],"on":[34,78],"the":[35,37,83],"season,":[36],"time":[38],"day,":[40],"different":[42,57],"in-building":[43],"activities.":[44],"These":[45],"activities":[46,76],"take":[47],"place":[48],"in":[49],"industrial":[50],"setup":[51],"24":[53],"h":[54],"have":[56],"HVAC":[58],"requirements.":[60],"In":[61],"paper,":[63],"we":[64],"propose":[65],"a":[66],"binary":[67],"(0,1)":[68],"integer":[69],"linear":[70],"programming":[71],"approach":[72],"to":[73,99],"efficiently":[74],"schedule":[75],"forecasting,":[80],"thus":[81],"minimizing":[82],"required":[85],"HVAC.":[87],"Experimental":[88],"results":[89],"show":[90],"that":[91],"consumption":[93],"can":[94],"be":[95],"reduced":[96],"up":[98],"30%.":[100]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":6},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":2},{"year":2020,"cited_by_count":5},{"year":2019,"cited_by_count":6},{"year":2018,"cited_by_count":2},{"year":2017,"cited_by_count":1}],"updated_date":"2026-07-02T09:51:11.867554","created_date":"2025-10-10T00:00:00"}