{"id":"https://openalex.org/W1978118650","doi":"https://doi.org/10.1109/acc.2014.6859151","title":"Energy-efficient control of under-actuated HVAC zones in buildings","display_name":"Energy-efficient control of under-actuated HVAC zones in buildings","publication_year":2014,"publication_date":"2014-06-01","ids":{"openalex":"https://openalex.org/W1978118650","doi":"https://doi.org/10.1109/acc.2014.6859151","mag":"1978118650"},"language":"en","primary_location":{"id":"doi:10.1109/acc.2014.6859151","is_oa":false,"landing_page_url":"https://doi.org/10.1109/acc.2014.6859151","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 American Control Conference","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5067448128","display_name":"Jonathan Brooks","orcid":"https://orcid.org/0000-0001-5365-2617"},"institutions":[{"id":"https://openalex.org/I33213144","display_name":"University of Florida","ror":"https://ror.org/02y3ad647","country_code":"US","type":"education","lineage":["https://openalex.org/I33213144"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Jonathan Brooks","raw_affiliation_strings":["University of Florida, Gainesville, FL, US","MAE Dept., Univ. of Florida, Gainesville, FL, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Florida, Gainesville, FL, US","institution_ids":["https://openalex.org/I33213144"]},{"raw_affiliation_string":"MAE Dept., Univ. of Florida, Gainesville, FL, USA","institution_ids":["https://openalex.org/I33213144"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5026067872","display_name":"Prabir Barooah","orcid":"https://orcid.org/0000-0002-2929-8301"},"institutions":[{"id":"https://openalex.org/I33213144","display_name":"University of Florida","ror":"https://ror.org/02y3ad647","country_code":"US","type":"education","lineage":["https://openalex.org/I33213144"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Prabir Barooah","raw_affiliation_strings":["University of Florida, Gainesville, FL, US","MAE Dept., Univ. of Florida, Gainesville, FL, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Florida, Gainesville, FL, US","institution_ids":["https://openalex.org/I33213144"]},{"raw_affiliation_string":"MAE Dept., Univ. of Florida, Gainesville, FL, USA","institution_ids":["https://openalex.org/I33213144"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.6741,"has_fulltext":false,"cited_by_count":15,"citation_normalized_percentile":{"value":0.84669844,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":"9","issue":null,"first_page":"424","last_page":"429"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11371","display_name":"Wind and Air Flow Studies","score":0.9710999727249146,"subfield":{"id":"https://openalex.org/subfields/2305","display_name":"Environmental Engineering"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hvac","display_name":"HVAC","score":0.9326440095901489},{"id":"https://openalex.org/keywords/occupancy","display_name":"Occupancy","score":0.8094054460525513},{"id":"https://openalex.org/keywords/variable-air-volume","display_name":"Variable air volume","score":0.7761212587356567},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"Air conditioning","score":0.7140648365020752},{"id":"https://openalex.org/keywords/model-predictive-control","display_name":"Model predictive control","score":0.6056796908378601},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.5891128182411194},{"id":"https://openalex.org/keywords/ventilation","display_name":"Ventilation (architecture)","score":0.5792214274406433},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.5777071118354797},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.5464431643486023},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.5423989295959473},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5378818511962891},{"id":"https://openalex.org/keywords/temperature-control","display_name":"Temperature control","score":0.4528423845767975},{"id":"https://openalex.org/keywords/airflow","display_name":"Airflow","score":0.4337575435638428},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.4311944842338562},{"id":"https://openalex.org/keywords/volume","display_name":"Volume (thermodynamics)","score":0.4205359220504761},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.4002643823623657},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.3692786693572998},{"id":"https://openalex.org/keywords/environmental-science","display_name":"Environmental science","score":0.36492300033569336},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.3236009478569031},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2628311216831207},{"id":"https://openalex.org/keywords/architectural-engineering","display_name":"Architectural engineering","score":0.1293124258518219},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.10225611925125122},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.09756383299827576},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.0822313129901886},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.07046568393707275}],"concepts":[{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.9326440095901489},{"id":"https://openalex.org/C160331591","wikidata":"https://www.wikidata.org/wiki/Q7075743","display_name":"Occupancy","level":2,"score":0.8094054460525513},{"id":"https://openalex.org/C51176869","wikidata":"https://www.wikidata.org/wiki/Q7915706","display_name":"Variable air volume","level":3,"score":0.7761212587356567},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.7140648365020752},{"id":"https://openalex.org/C172205157","wikidata":"https://www.wikidata.org/wiki/Q1782962","display_name":"Model predictive control","level":3,"score":0.6056796908378601},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.5891128182411194},{"id":"https://openalex.org/C200457457","wikidata":"https://www.wikidata.org/wiki/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.5792214274406433},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.5777071118354797},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.5464431643486023},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.5423989295959473},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5378818511962891},{"id":"https://openalex.org/C536315585","wikidata":"https://www.wikidata.org/wiki/Q7698332","display_name":"Temperature control","level":2,"score":0.4528423845767975},{"id":"https://openalex.org/C116067010","wikidata":"https://www.wikidata.org/wiki/Q4698686","display_name":"Airflow","level":2,"score":0.4337575435638428},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.4311944842338562},{"id":"https://openalex.org/C20556612","wikidata":"https://www.wikidata.org/wiki/Q4469374","display_name":"Volume (thermodynamics)","level":2,"score":0.4205359220504761},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.4002643823623657},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.3692786693572998},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.36492300033569336},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3236009478569031},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2628311216831207},{"id":"https://openalex.org/C170154142","wikidata":"https://www.wikidata.org/wiki/Q150737","display_name":"Architectural engineering","level":1,"score":0.1293124258518219},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.10225611925125122},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.09756383299827576},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0822313129901886},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.07046568393707275},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C6557445","wikidata":"https://www.wikidata.org/wiki/Q173113","display_name":"Agronomy","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/acc.2014.6859151","is_oa":false,"landing_page_url":"https://doi.org/10.1109/acc.2014.6859151","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 American Control Conference","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.9100000262260437,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":22,"referenced_works":["https://openalex.org/W1970181869","https://openalex.org/W2020314398","https://openalex.org/W2039105817","https://openalex.org/W2042317950","https://openalex.org/W2064999786","https://openalex.org/W2077589412","https://openalex.org/W2083974252","https://openalex.org/W2089832331","https://openalex.org/W2113291960","https://openalex.org/W2113994252","https://openalex.org/W2114117309","https://openalex.org/W2123871098","https://openalex.org/W2127559206","https://openalex.org/W2136369753","https://openalex.org/W2163239971","https://openalex.org/W2164038031","https://openalex.org/W2164132178","https://openalex.org/W2166313543","https://openalex.org/W2223761917","https://openalex.org/W2622603338","https://openalex.org/W6676827085","https://openalex.org/W6684085282"],"related_works":["https://openalex.org/W3045934583","https://openalex.org/W2437015738","https://openalex.org/W4312641736","https://openalex.org/W4283833227","https://openalex.org/W3093054803","https://openalex.org/W2616917605","https://openalex.org/W2053123345","https://openalex.org/W3046823714","https://openalex.org/W2348218441","https://openalex.org/W2360486038"],"abstract_inverted_index":{"We":[0],"study":[1,103],"control-oriented":[2],"methods":[3],"of":[4,8,60,74,137,153],"improving":[5],"energy":[6,111],"efficiency":[7,136],"\u201cunder-actuated\u201d":[9],"heating,":[10],"ventilation,":[11],"and":[12,47,62,72],"air-conditioning":[13],"systems":[14],"in":[15,80,92,99,122],"commercial":[16,100],"buildings":[17],"where":[18],"multiple":[19],"rooms":[20,79,124],"are":[21,34,96],"served":[22],"by":[23],"a":[24,38,81],"single":[25],"variable":[26],"air":[27,76],"volume":[28],"box.":[29],"Two":[30],"novel":[31],"control":[32,55],"algorithms":[33],"studied:":[35],"one":[36],"is":[37,50,107,125,130],"rule-based,":[39],"feedback":[40],"controller":[41],"that":[42,57,105,141],"uses":[43,58],"real-time":[44],"occupancy":[45,61,121,143],"measurements,":[46],"the":[48,93,123],"other":[49,63],"based":[51],"on":[52,151,160],"model":[53],"predictive":[54],"(MPC)":[56],"predictions":[59],"exogenous":[64],"inputs.":[65],"In":[66],"an":[67],"under-actuated":[68,118],"zone,":[69],"flow":[70],"rate":[71],"temperature":[73,154],"ventilation":[75],"to":[77,114,147],"individual":[78],"zone":[82],"cannot":[83],"be":[84,148],"independently":[85],"controlled.":[86],"These":[87],"have":[88],"not":[89,167],"been":[90],"studied":[91],"literature":[94],"but":[95],"quite":[97],"common":[98],"buildings.":[101],"Our":[102],"finds":[104],"there":[106],"potential":[108],"for":[109,117,132],"significant":[110],"savings":[112],"relative":[113],"conventional":[115],"controllers":[116,140],"zones\u2014even":[119],"when":[120],"vastly":[126],"different\u2014when":[127],"independent":[128],"heating":[129],"available":[131],"each":[133],"room.":[134],"Energy":[135],"simple,":[138],"rule-based":[139,171],"use":[142],"measurements":[144],"was":[145],"found":[146],"highly":[149],"dependent":[150],"choice":[152],"constraints":[155],"during":[156],"unoccupied":[157],"times.":[158],"Depending":[159],"this":[161],"choice,":[162],"MPC":[163],"may":[164,166],"or":[165],"perform":[168],"better":[169],"than":[170],"control.":[172]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":3},{"year":2022,"cited_by_count":2},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2016,"cited_by_count":2},{"year":2015,"cited_by_count":2}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
