{"id":"https://openalex.org/W2092230348","doi":"https://doi.org/10.1109/acc.2012.6314830","title":"Isolation and handling of sensor faults in nonlinear systems","display_name":"Isolation and handling of sensor faults in nonlinear systems","publication_year":2012,"publication_date":"2012-06-01","ids":{"openalex":"https://openalex.org/W2092230348","doi":"https://doi.org/10.1109/acc.2012.6314830","mag":"2092230348"},"language":"en","primary_location":{"id":"doi:10.1109/acc.2012.6314830","is_oa":false,"landing_page_url":"https://doi.org/10.1109/acc.2012.6314830","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 American Control Conference (ACC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100553993","display_name":"Miao Du","orcid":null},"institutions":[{"id":"https://openalex.org/I98251732","display_name":"McMaster University","ror":"https://ror.org/02fa3aq29","country_code":"CA","type":"education","lineage":["https://openalex.org/I98251732"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Miao Du","raw_affiliation_strings":["Department of Chemical Engineering, McMaster University, Hamilton, ONT, Canada","Department of Chemical Engineering, McMaster University, Hamilton, ON L8S 4L7, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Chemical Engineering, McMaster University, Hamilton, ONT, Canada","institution_ids":["https://openalex.org/I98251732"]},{"raw_affiliation_string":"Department of Chemical Engineering, McMaster University, Hamilton, ON L8S 4L7, Canada","institution_ids":["https://openalex.org/I98251732"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5016353717","display_name":"Prashant Mhaskar","orcid":"https://orcid.org/0000-0001-5866-211X"},"institutions":[{"id":"https://openalex.org/I98251732","display_name":"McMaster University","ror":"https://ror.org/02fa3aq29","country_code":"CA","type":"education","lineage":["https://openalex.org/I98251732"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Prashant Mhaskar","raw_affiliation_strings":["Department of Chemical Engineering, McMaster University, Hamilton, ONT, Canada","Department of Chemical Engineering, McMaster University, Hamilton, ON L8S 4L7, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Chemical Engineering, McMaster University, Hamilton, ONT, Canada","institution_ids":["https://openalex.org/I98251732"]},{"raw_affiliation_string":"Department of Chemical Engineering, McMaster University, Hamilton, ON L8S 4L7, Canada","institution_ids":["https://openalex.org/I98251732"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.1369,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.83268214,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":96},"biblio":{"volume":"44","issue":null,"first_page":"6661","last_page":"6666"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10791","display_name":"Advanced Control Systems Optimization","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11236","display_name":"Control Systems and Identification","score":0.9940999746322632,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/redundancy","display_name":"Redundancy (engineering)","score":0.815422773361206},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.8125080466270447},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.6746155023574829},{"id":"https://openalex.org/keywords/nonlinear-system","display_name":"Nonlinear system","score":0.6398212909698486},{"id":"https://openalex.org/keywords/observer","display_name":"Observer (physics)","score":0.6234160661697388},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5279221534729004},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.5141046643257141},{"id":"https://openalex.org/keywords/exploit","display_name":"Exploit","score":0.47002220153808594},{"id":"https://openalex.org/keywords/state-observer","display_name":"State observer","score":0.4433685839176178},{"id":"https://openalex.org/keywords/isolation","display_name":"Isolation (microbiology)","score":0.41674405336380005},{"id":"https://openalex.org/keywords/control-system","display_name":"Control system","score":0.41069328784942627},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3844078779220581},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.28493884205818176},{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.17756199836730957},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.11052241921424866}],"concepts":[{"id":"https://openalex.org/C152124472","wikidata":"https://www.wikidata.org/wiki/Q1204361","display_name":"Redundancy (engineering)","level":2,"score":0.815422773361206},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.8125080466270447},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.6746155023574829},{"id":"https://openalex.org/C158622935","wikidata":"https://www.wikidata.org/wiki/Q660848","display_name":"Nonlinear system","level":2,"score":0.6398212909698486},{"id":"https://openalex.org/C2780704645","wikidata":"https://www.wikidata.org/wiki/Q9251458","display_name":"Observer (physics)","level":2,"score":0.6234160661697388},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5279221534729004},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.5141046643257141},{"id":"https://openalex.org/C165696696","wikidata":"https://www.wikidata.org/wiki/Q11287","display_name":"Exploit","level":2,"score":0.47002220153808594},{"id":"https://openalex.org/C3031470","wikidata":"https://www.wikidata.org/wiki/Q818544","display_name":"State observer","level":3,"score":0.4433685839176178},{"id":"https://openalex.org/C2775941552","wikidata":"https://www.wikidata.org/wiki/Q25212305","display_name":"Isolation (microbiology)","level":2,"score":0.41674405336380005},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.41069328784942627},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3844078779220581},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.28493884205818176},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.17756199836730957},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.11052241921424866},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C89423630","wikidata":"https://www.wikidata.org/wiki/Q7193","display_name":"Microbiology","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/acc.2012.6314830","is_oa":false,"landing_page_url":"https://doi.org/10.1109/acc.2012.6314830","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 American Control Conference (ACC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":17,"referenced_works":["https://openalex.org/W1928777841","https://openalex.org/W1964729920","https://openalex.org/W1969904324","https://openalex.org/W1977834922","https://openalex.org/W2001041931","https://openalex.org/W2025420571","https://openalex.org/W2064345863","https://openalex.org/W2069717830","https://openalex.org/W2081341054","https://openalex.org/W2086706893","https://openalex.org/W2109049058","https://openalex.org/W2110710005","https://openalex.org/W2139978282","https://openalex.org/W2150005359","https://openalex.org/W2151132523","https://openalex.org/W2156279034","https://openalex.org/W2160725977"],"related_works":["https://openalex.org/W2065965834","https://openalex.org/W2394201814","https://openalex.org/W3121254296","https://openalex.org/W2060193301","https://openalex.org/W2544838361","https://openalex.org/W2315418312","https://openalex.org/W2501264310","https://openalex.org/W2113447317","https://openalex.org/W4205434950","https://openalex.org/W2111927334"],"abstract_inverted_index":{"This":[0],"work":[1],"considers":[2],"the":[3,26,58,62,79,86,96,102],"problem":[4],"of":[5,25,61,71,74,95,101],"sensor":[6,33],"fault":[7],"detection":[8],"and":[9,12,104],"isolation":[10],"(FDI)":[11],"fault-tolerant":[13],"control":[14,45],"for":[15],"nonlinear":[16],"systems":[17],"subject":[18],"to":[19,30,91],"input":[20],"constraints.":[21],"The":[22,99],"key":[23],"idea":[24],"proposed":[27],"method":[28],"is":[29,50,65,69,89,107],"exploit":[31],"model-based":[32],"redundancy":[34],"through":[35],"state":[36,80],"observer":[37,63],"design.":[38],"To":[39],"this":[40],"end,":[41],"an":[42],"output":[43],"feedback":[44],"design":[46,64],"using":[47,83,109],"high-gain":[48,75],"observers":[49],"first":[51],"presented.":[52],"An":[53],"FDI":[54,103],"scheme":[55],"that":[56],"utilizes":[57],"enhanced":[59],"applicability":[60],"then":[66],"proposed,":[67],"which":[68],"composed":[70],"a":[72,110],"bank":[73],"observers.":[76],"Upon":[77],"FDI,":[78],"estimate":[81],"generated":[82],"measurements":[84],"from":[85],"healthy":[87],"sensors":[88],"used":[90],"preserve":[92],"practical":[93],"stability":[94],"closed-loop":[97],"system.":[98],"implementation":[100],"fault-handling":[105],"framework":[106],"illustrated":[108],"chemical":[111],"reactor":[112],"example.":[113]},"counts_by_year":[{"year":2018,"cited_by_count":2},{"year":2013,"cited_by_count":2}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
