{"id":"https://openalex.org/W2151397260","doi":"https://doi.org/10.1109/acc.2008.4586698","title":"Model-based predictive control of a multi-evaporator vapor compression cooling cycle","display_name":"Model-based predictive control of a multi-evaporator vapor compression cooling cycle","publication_year":2008,"publication_date":"2008-06-01","ids":{"openalex":"https://openalex.org/W2151397260","doi":"https://doi.org/10.1109/acc.2008.4586698","mag":"2151397260"},"language":"en","primary_location":{"id":"doi:10.1109/acc.2008.4586698","is_oa":false,"landing_page_url":"https://doi.org/10.1109/acc.2008.4586698","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2008 American Control Conference","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5104351614","display_name":"Matthew Elliott","orcid":null},"institutions":[{"id":"https://openalex.org/I91045830","display_name":"Texas A&M University","ror":"https://ror.org/01f5ytq51","country_code":"US","type":"education","lineage":["https://openalex.org/I91045830"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Matthew S. Elliott","raw_affiliation_strings":["Department of Mechanical Engineering, Texas A and M University, College Station, TX, USA"],"affiliations":[{"raw_affiliation_string":"Department of Mechanical Engineering, Texas A and M University, College Station, TX, USA","institution_ids":["https://openalex.org/I91045830"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5008830504","display_name":"Bryan P. Rasmussen","orcid":"https://orcid.org/0000-0001-7342-2851"},"institutions":[{"id":"https://openalex.org/I91045830","display_name":"Texas A&M University","ror":"https://ror.org/01f5ytq51","country_code":"US","type":"education","lineage":["https://openalex.org/I91045830"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Bryan P. Rasmussen","raw_affiliation_strings":["Mechanical Engineering, Texas A and M University, College Station, TX, USA"],"affiliations":[{"raw_affiliation_string":"Mechanical Engineering, Texas A and M University, College Station, TX, USA","institution_ids":["https://openalex.org/I91045830"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5104351614"],"corresponding_institution_ids":["https://openalex.org/I91045830"],"apc_list":null,"apc_paid":null,"fwci":4.1125,"has_fulltext":false,"cited_by_count":51,"citation_normalized_percentile":{"value":0.94039854,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":90,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"1463","last_page":"1468"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10791","display_name":"Advanced Control Systems Optimization","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10791","display_name":"Advanced Control Systems Optimization","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.9951000213623047,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11053","display_name":"Process Optimization and Integration","score":0.9908000230789185,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/vapor-compression-refrigeration","display_name":"Vapor-compression refrigeration","score":0.8749266862869263},{"id":"https://openalex.org/keywords/evaporator","display_name":"Evaporator","score":0.853557825088501},{"id":"https://openalex.org/keywords/model-predictive-control","display_name":"Model predictive control","score":0.742390513420105},{"id":"https://openalex.org/keywords/gas-compressor","display_name":"Gas compressor","score":0.695006787776947},{"id":"https://openalex.org/keywords/thermal-expansion-valve","display_name":"Thermal expansion valve","score":0.6271367073059082},{"id":"https://openalex.org/keywords/refrigeration","display_name":"Refrigeration","score":0.554955005645752},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"Air conditioning","score":0.5380114912986755},{"id":"https://openalex.org/keywords/control-system","display_name":"Control system","score":0.5343040227890015},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.5057001113891602},{"id":"https://openalex.org/keywords/cooling-capacity","display_name":"Cooling capacity","score":0.5002872943878174},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.4964786171913147},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4647029936313629},{"id":"https://openalex.org/keywords/temperature-control","display_name":"Temperature control","score":0.43509337306022644},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.42225080728530884},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.40715983510017395},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.3216487169265747},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2879965901374817},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.14895111322402954},{"id":"https://openalex.org/keywords/refrigerant","display_name":"Refrigerant","score":0.12729215621948242}],"concepts":[{"id":"https://openalex.org/C36570524","wikidata":"https://www.wikidata.org/wiki/Q615475","display_name":"Vapor-compression refrigeration","level":4,"score":0.8749266862869263},{"id":"https://openalex.org/C91311341","wikidata":"https://www.wikidata.org/wiki/Q1764892","display_name":"Evaporator","level":3,"score":0.853557825088501},{"id":"https://openalex.org/C172205157","wikidata":"https://www.wikidata.org/wiki/Q1782962","display_name":"Model predictive control","level":3,"score":0.742390513420105},{"id":"https://openalex.org/C131097465","wikidata":"https://www.wikidata.org/wiki/Q178898","display_name":"Gas compressor","level":2,"score":0.695006787776947},{"id":"https://openalex.org/C184593036","wikidata":"https://www.wikidata.org/wiki/Q279421","display_name":"Thermal expansion valve","level":4,"score":0.6271367073059082},{"id":"https://openalex.org/C69907114","wikidata":"https://www.wikidata.org/wiki/Q747713","display_name":"Refrigeration","level":2,"score":0.554955005645752},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.5380114912986755},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.5343040227890015},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.5057001113891602},{"id":"https://openalex.org/C164915370","wikidata":"https://www.wikidata.org/wiki/Q5167494","display_name":"Cooling capacity","level":2,"score":0.5002872943878174},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.4964786171913147},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4647029936313629},{"id":"https://openalex.org/C536315585","wikidata":"https://www.wikidata.org/wiki/Q7698332","display_name":"Temperature control","level":2,"score":0.43509337306022644},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.42225080728530884},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.40715983510017395},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.3216487169265747},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2879965901374817},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.14895111322402954},{"id":"https://openalex.org/C199499590","wikidata":"https://www.wikidata.org/wiki/Q266790","display_name":"Refrigerant","level":3,"score":0.12729215621948242},{"id":"https://openalex.org/C6557445","wikidata":"https://www.wikidata.org/wiki/Q173113","display_name":"Agronomy","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/acc.2008.4586698","is_oa":false,"landing_page_url":"https://doi.org/10.1109/acc.2008.4586698","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2008 American Control Conference","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.9100000262260437}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":8,"referenced_works":["https://openalex.org/W178056938","https://openalex.org/W1965324089","https://openalex.org/W2076420009","https://openalex.org/W2132800800","https://openalex.org/W2142788127","https://openalex.org/W2979925632","https://openalex.org/W3102923851","https://openalex.org/W4292069080"],"related_works":["https://openalex.org/W2969464436","https://openalex.org/W1995478587","https://openalex.org/W3131096903","https://openalex.org/W2019894243","https://openalex.org/W2331271821","https://openalex.org/W4235850239","https://openalex.org/W2905005384","https://openalex.org/W2563064567","https://openalex.org/W4386334208","https://openalex.org/W2006412919"],"abstract_inverted_index":{"This":[0,57,104],"paper":[1,58],"presents":[2],"a":[3,30,60,66,81],"decentralized":[4,61],"control":[5,39,62,112,126],"architecture":[6,127],"for":[7,23],"multiple":[8],"evaporator":[9,77],"vapor":[10],"compression":[11,18],"systems":[12,19],"using":[13],"model-based":[14],"predictive":[15],"control.":[16],"Vapor":[17],"are":[20,90],"widely":[21],"used":[22,91],"heating,":[24],"air-conditioning":[25],"and":[26,28,86,100],"refrigeration,":[27],"constitute":[29],"major":[31],"part":[32],"of":[33,54,68,75,123],"total":[34],"US":[35],"energy":[36,47],"use.":[37],"Advanced":[38],"strategies":[40],"have":[41],"the":[42,51,72,124],"potential":[43],"to":[44,92],"significantly":[45],"increase":[46],"efficiency,":[48],"while":[49],"delivering":[50],"necessary":[52],"amount":[53],"cooling":[55,73],"capacity.":[56],"proposes":[59],"approach":[63],"based":[64],"on":[65,130],"study":[67],"interacting":[69],"dynamics,":[70],"wherein":[71],"capacity":[74],"each":[76],"is":[78,105,128],"controlled":[79],"by":[80,96],"multi-input,":[82],"multi-output":[83],"MPC":[84],"controller":[85],"standard":[87],"PI":[88],"controllers":[89],"regulate":[93],"system":[94],"pressures":[95],"modulating":[97],"compressor":[98],"speed":[99],"discharge":[101],"valve":[102],"opening.":[103],"in":[106,117],"contrast":[107],"with":[108],"traditional":[109],"single-input,":[110],"single-output":[111],"approaches,":[113],"which":[114],"can":[115],"result":[116],"undesired":[118],"dynamic":[119],"behavior.":[120],"The":[121],"efficacy":[122],"proposed":[125],"demonstrated":[129],"an":[131],"experimental":[132],"system.":[133]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2022,"cited_by_count":4},{"year":2020,"cited_by_count":3},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":3},{"year":2017,"cited_by_count":5},{"year":2016,"cited_by_count":7},{"year":2015,"cited_by_count":3},{"year":2014,"cited_by_count":5},{"year":2013,"cited_by_count":8},{"year":2012,"cited_by_count":6}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}