{"id":"https://openalex.org/W2127581631","doi":"https://doi.org/10.1109/acc.2007.4282325","title":"Stabilizing control for power converters connected to transmission lines","display_name":"Stabilizing control for power converters connected to transmission lines","publication_year":2007,"publication_date":"2007-07-01","ids":{"openalex":"https://openalex.org/W2127581631","doi":"https://doi.org/10.1109/acc.2007.4282325","mag":"2127581631"},"language":"en","primary_location":{"id":"doi:10.1109/acc.2007.4282325","is_oa":false,"landing_page_url":"https://doi.org/10.1109/acc.2007.4282325","pdf_url":null,"source":{"id":"https://openalex.org/S4210168941","display_name":"Proceedings of the ... American Control Conference/Proceedings of the American Control Conference","issn_l":"0743-1619","issn":["0743-1619","2378-5861"],"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2007 American Control Conference","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://research.rug.nl/en/publications/4e3d5cdf-3db1-44bb-ba48-1539f0557520","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5054141449","display_name":"Marius Zainea","orcid":null},"institutions":[{"id":"https://openalex.org/I102475099","display_name":"Sup\u00e9lec","ror":"https://ror.org/00n7gwn90","country_code":"FR","type":"education","lineage":["https://openalex.org/I102475099"]},{"id":"https://openalex.org/I4210100151","display_name":"Institut d'\u00c9lectronique et des Technologies du num\u00e9Rique","ror":"https://ror.org/013q33h79","country_code":"FR","type":"facility","lineage":["https://openalex.org/I1294671590","https://openalex.org/I1294671590","https://openalex.org/I28221208","https://openalex.org/I4210095849","https://openalex.org/I4210100151","https://openalex.org/I56067802","https://openalex.org/I97188460"]}],"countries":["FR"],"is_corresponding":true,"raw_author_name":"Marius Zainea","raw_affiliation_strings":["IETR-Sup\u00e9lec, Hybrid Systems Control Group, France","IETR-Supelec, Cesson-Sevigne"],"affiliations":[{"raw_affiliation_string":"IETR-Sup\u00e9lec, Hybrid Systems Control Group, France","institution_ids":["https://openalex.org/I102475099","https://openalex.org/I4210100151"]},{"raw_affiliation_string":"IETR-Supelec, Cesson-Sevigne","institution_ids":["https://openalex.org/I102475099"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5005018540","display_name":"Arjan van der Schaft","orcid":"https://orcid.org/0000-0002-2383-9234"},"institutions":[{"id":"https://openalex.org/I169381384","display_name":"University of Groningen","ror":"https://ror.org/012p63287","country_code":"NL","type":"education","lineage":["https://openalex.org/I169381384"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Arjan van der Schaft","raw_affiliation_strings":["Research Institute for Mathematics and Computer Science, University of Groningam, Groningen, Netherlands","Research Institute for Mathematics and Computer Science, University of Groningen, PO Box 800, 9700 AV Groningen, the Netherlands. A.J.van.der.Schaft@math.rug.nl"],"affiliations":[{"raw_affiliation_string":"Research Institute for Mathematics and Computer Science, University of Groningam, Groningen, Netherlands","institution_ids":["https://openalex.org/I169381384"]},{"raw_affiliation_string":"Research Institute for Mathematics and Computer Science, University of Groningen, PO Box 800, 9700 AV Groningen, the Netherlands. A.J.van.der.Schaft@math.rug.nl","institution_ids":["https://openalex.org/I169381384"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5111973794","display_name":"Jean Buisson","orcid":null},"institutions":[{"id":"https://openalex.org/I102475099","display_name":"Sup\u00e9lec","ror":"https://ror.org/00n7gwn90","country_code":"FR","type":"education","lineage":["https://openalex.org/I102475099"]},{"id":"https://openalex.org/I4210100151","display_name":"Institut d'\u00c9lectronique et des Technologies du num\u00e9Rique","ror":"https://ror.org/013q33h79","country_code":"FR","type":"facility","lineage":["https://openalex.org/I1294671590","https://openalex.org/I1294671590","https://openalex.org/I28221208","https://openalex.org/I4210095849","https://openalex.org/I4210100151","https://openalex.org/I56067802","https://openalex.org/I97188460"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Jean Buisson","raw_affiliation_strings":["IETR-Sup\u00e9lec, Hybrid Systems Control Group, France","IETR- Sup\u00e9lec, Hybrid Systems Control Group, Avenue de la Boulaie BP 81127, F35511 Cesson-S\u00e9vign\u00e9 Cedex, France. jean.buisson@supelec.fr"],"affiliations":[{"raw_affiliation_string":"IETR-Sup\u00e9lec, Hybrid Systems Control Group, France","institution_ids":["https://openalex.org/I102475099","https://openalex.org/I4210100151"]},{"raw_affiliation_string":"IETR- Sup\u00e9lec, Hybrid Systems Control Group, Avenue de la Boulaie BP 81127, F35511 Cesson-S\u00e9vign\u00e9 Cedex, France. jean.buisson@supelec.fr","institution_ids":["https://openalex.org/I102475099","https://openalex.org/I4210100151"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5054141449"],"corresponding_institution_ids":["https://openalex.org/I102475099","https://openalex.org/I4210100151"],"apc_list":null,"apc_paid":null,"fwci":1.1283,"has_fulltext":false,"cited_by_count":17,"citation_normalized_percentile":{"value":0.72609099,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"3476","last_page":"3481"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9987999796867371,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9987999796867371,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12772","display_name":"Control and Stability of Dynamical Systems","score":0.9980999827384949,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9940000176429749,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.7475468516349792},{"id":"https://openalex.org/keywords/commutation","display_name":"Commutation","score":0.736831545829773},{"id":"https://openalex.org/keywords/converters","display_name":"Converters","score":0.7009201645851135},{"id":"https://openalex.org/keywords/lyapunov-function","display_name":"Lyapunov function","score":0.607430100440979},{"id":"https://openalex.org/keywords/electric-power-transmission","display_name":"Electric power transmission","score":0.5703179836273193},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.5619032382965088},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5433299541473389},{"id":"https://openalex.org/keywords/transmission-line","display_name":"Transmission line","score":0.5161817669868469},{"id":"https://openalex.org/keywords/power-control","display_name":"Power control","score":0.5072736144065857},{"id":"https://openalex.org/keywords/commutation-cell","display_name":"Commutation cell","score":0.4906579256057739},{"id":"https://openalex.org/keywords/line","display_name":"Line (geometry)","score":0.483808696269989},{"id":"https://openalex.org/keywords/transmission","display_name":"Transmission (telecommunications)","score":0.45284122228622437},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.4456577003002167},{"id":"https://openalex.org/keywords/function","display_name":"Function (biology)","score":0.4170609414577484},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2587122917175293},{"id":"https://openalex.org/keywords/switched-mode-power-supply","display_name":"Switched-mode power supply","score":0.2509559988975525},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.2223818600177765},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.17331305146217346},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.14750105142593384},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.13211458921432495},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.07527318596839905}],"concepts":[{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.7475468516349792},{"id":"https://openalex.org/C2780147050","wikidata":"https://www.wikidata.org/wiki/Q5155085","display_name":"Commutation","level":3,"score":0.736831545829773},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.7009201645851135},{"id":"https://openalex.org/C60640748","wikidata":"https://www.wikidata.org/wiki/Q2337858","display_name":"Lyapunov function","level":3,"score":0.607430100440979},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.5703179836273193},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.5619032382965088},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5433299541473389},{"id":"https://openalex.org/C33441834","wikidata":"https://www.wikidata.org/wiki/Q693004","display_name":"Transmission line","level":2,"score":0.5161817669868469},{"id":"https://openalex.org/C56685638","wikidata":"https://www.wikidata.org/wiki/Q2300474","display_name":"Power control","level":3,"score":0.5072736144065857},{"id":"https://openalex.org/C141572892","wikidata":"https://www.wikidata.org/wiki/Q5155086","display_name":"Commutation cell","level":5,"score":0.4906579256057739},{"id":"https://openalex.org/C198352243","wikidata":"https://www.wikidata.org/wiki/Q37105","display_name":"Line (geometry)","level":2,"score":0.483808696269989},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.45284122228622437},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.4456577003002167},{"id":"https://openalex.org/C14036430","wikidata":"https://www.wikidata.org/wiki/Q3736076","display_name":"Function (biology)","level":2,"score":0.4170609414577484},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2587122917175293},{"id":"https://openalex.org/C151799858","wikidata":"https://www.wikidata.org/wiki/Q587008","display_name":"Switched-mode power supply","level":3,"score":0.2509559988975525},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.2223818600177765},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.17331305146217346},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.14750105142593384},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.13211458921432495},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.07527318596839905},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C158622935","wikidata":"https://www.wikidata.org/wiki/Q660848","display_name":"Nonlinear system","level":2,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C29586797","wikidata":"https://www.wikidata.org/wiki/Q5163663","display_name":"Constant power circuit","level":4,"score":0.0},{"id":"https://openalex.org/C78458016","wikidata":"https://www.wikidata.org/wiki/Q840400","display_name":"Evolutionary biology","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1109/acc.2007.4282325","is_oa":false,"landing_page_url":"https://doi.org/10.1109/acc.2007.4282325","pdf_url":null,"source":{"id":"https://openalex.org/S4210168941","display_name":"Proceedings of the ... American Control Conference/Proceedings of the American Control Conference","issn_l":"0743-1619","issn":["0743-1619","2378-5861"],"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2007 American Control Conference","raw_type":"proceedings-article"},{"id":"pmh:oai:pure.rug.nl:openaire/4e3d5cdf-3db1-44bb-ba48-1539f0557520","is_oa":true,"landing_page_url":"https://research.rug.nl/en/publications/4e3d5cdf-3db1-44bb-ba48-1539f0557520","pdf_url":null,"source":{"id":"https://openalex.org/S4306400420","display_name":"University of Groningen research database (University of Groningen / Centre for Information Technology)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I169381384","host_organization_name":"University of Groningen","host_organization_lineage":["https://openalex.org/I169381384"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Zainea, M, Schaft, A V D & Buisson, J 2007, Stabilizing control for power converters connected to transmission lines. in Proceedings of the American Control Conference, 2007. University of Groningen, Johann Bernoulli Institute for Mathematics and Computer Science.","raw_type":"info:eu-repo/semantics/publishedVersion"},{"id":"pmh:oai:HAL:hal-00189547v1","is_oa":false,"landing_page_url":"https://hal.science/hal-00189547","pdf_url":null,"source":{"id":"https://openalex.org/S4406922461","display_name":"SPIRE - Sciences Po Institutional REpository","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"2007 American Control Conference, Jul 2007, New-York city, United States. pp.3476-3481","raw_type":"Conference papers"}],"best_oa_location":{"id":"pmh:oai:pure.rug.nl:openaire/4e3d5cdf-3db1-44bb-ba48-1539f0557520","is_oa":true,"landing_page_url":"https://research.rug.nl/en/publications/4e3d5cdf-3db1-44bb-ba48-1539f0557520","pdf_url":null,"source":{"id":"https://openalex.org/S4306400420","display_name":"University of Groningen research database (University of Groningen / Centre for Information Technology)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I169381384","host_organization_name":"University of Groningen","host_organization_lineage":["https://openalex.org/I169381384"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Zainea, M, Schaft, A V D & Buisson, J 2007, Stabilizing control for power converters connected to transmission lines. in Proceedings of the American Control Conference, 2007. University of Groningen, Johann Bernoulli Institute for Mathematics and Computer Science.","raw_type":"info:eu-repo/semantics/publishedVersion"},"sustainable_development_goals":[{"score":0.8299999833106995,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320320300","display_name":"European Commission","ror":"https://ror.org/00k4n6c32"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":19,"referenced_works":["https://openalex.org/W429088565","https://openalex.org/W1481666617","https://openalex.org/W1552880419","https://openalex.org/W1597768990","https://openalex.org/W1988040344","https://openalex.org/W2053147628","https://openalex.org/W2097607574","https://openalex.org/W2101636738","https://openalex.org/W2109865587","https://openalex.org/W2115293734","https://openalex.org/W2130608621","https://openalex.org/W2144355672","https://openalex.org/W2149941656","https://openalex.org/W2788256603","https://openalex.org/W2988788030","https://openalex.org/W4245176833","https://openalex.org/W6647564972","https://openalex.org/W6672321567","https://openalex.org/W6682237815"],"related_works":["https://openalex.org/W2168175536","https://openalex.org/W2087232412","https://openalex.org/W2385309427","https://openalex.org/W2146784146","https://openalex.org/W2011724798","https://openalex.org/W1960067129","https://openalex.org/W1494014730","https://openalex.org/W2136639791","https://openalex.org/W3194537130","https://openalex.org/W809035092"],"abstract_inverted_index":{"This":[0],"paper":[1],"proposes":[2],"a":[3,12,17,21,27,60,70,73,78,85],"switching":[4,56],"control":[5,57,68],"strategy":[6,25,76,81],"for":[7],"the":[8,38,45,50,64,67],"set-point":[9],"stabilization":[10],"of":[11,37,44,66],"power":[13,39],"converter":[14],"connected":[15],"via":[16],"transmission":[18,46],"line":[19,47],"to":[20],"resistive":[22],"load.":[23],"The":[24,53],"employs":[26],"Lyapunov":[28],"function":[29],"that":[30],"is":[31],"directly":[32],"based":[33],"on":[34,84],"energy":[35],"considerations":[36],"converter,":[40],"as":[41,43],"well":[42],"described":[48],"by":[49],"telegraph":[51],"equations.":[52],"proposed":[54],"stabilizing":[55],"still":[58],"allows":[59],"certain":[61],"freedom":[62],"in":[63],"choice":[65],"law,":[69],"comparison":[71],"between":[72],"maximum":[74],"descent":[75],"and":[77],"minimum":[79],"commutation":[80],"being":[82],"discussed":[83],"simple":[86],"example.":[87]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":3},{"year":2022,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":1},{"year":2012,"cited_by_count":3}],"updated_date":"2026-04-04T16:13:02.066488","created_date":"2025-10-10T00:00:00"}
