{"id":"https://openalex.org/W2112727346","doi":"https://doi.org/10.1109/acc.2007.4282229","title":"Estimation of Fatigue Life Using Ultrasonic Sensing: A Symbolic Dynamics Approach","display_name":"Estimation of Fatigue Life Using Ultrasonic Sensing: A Symbolic Dynamics Approach","publication_year":2007,"publication_date":"2007-07-01","ids":{"openalex":"https://openalex.org/W2112727346","doi":"https://doi.org/10.1109/acc.2007.4282229","mag":"2112727346"},"language":"en","primary_location":{"id":"doi:10.1109/acc.2007.4282229","is_oa":false,"landing_page_url":"https://doi.org/10.1109/acc.2007.4282229","pdf_url":null,"source":{"id":"https://openalex.org/S4210168941","display_name":"Proceedings of the ... American Control Conference/Proceedings of the American Control Conference","issn_l":"0743-1619","issn":["0743-1619","2378-5861"],"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2007 American Control Conference","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100331772","display_name":"Shalabh Gupta","orcid":"https://orcid.org/0000-0003-0438-7700"},"institutions":[{"id":"https://openalex.org/I130769515","display_name":"Pennsylvania State University","ror":"https://ror.org/04p491231","country_code":"US","type":"education","lineage":["https://openalex.org/I130769515"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Shalabh Gupta","raw_affiliation_strings":["Pennsylvania State University, University Park, PA, USA","Pennsylvania State University, University Park#TAB#"],"affiliations":[{"raw_affiliation_string":"Pennsylvania State University, University Park, PA, USA","institution_ids":["https://openalex.org/I130769515"]},{"raw_affiliation_string":"Pennsylvania State University, University Park#TAB#","institution_ids":["https://openalex.org/I130769515"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5003487011","display_name":"Asok Ray","orcid":"https://orcid.org/0000-0003-4124-0230"},"institutions":[{"id":"https://openalex.org/I130769515","display_name":"Pennsylvania State University","ror":"https://ror.org/04p491231","country_code":"US","type":"education","lineage":["https://openalex.org/I130769515"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Asok Ray","raw_affiliation_strings":["Pennsylvania State University, University Park, PA, USA","Pennsylvania State University, University Park#TAB#"],"affiliations":[{"raw_affiliation_string":"Pennsylvania State University, University Park, PA, USA","institution_ids":["https://openalex.org/I130769515"]},{"raw_affiliation_string":"Pennsylvania State University, University Park#TAB#","institution_ids":["https://openalex.org/I130769515"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5100331772"],"corresponding_institution_ids":["https://openalex.org/I130769515"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.25122549,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1149","last_page":"1154"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10534","display_name":"Structural Health Monitoring Techniques","score":0.9758999943733215,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10534","display_name":"Structural Health Monitoring Techniques","score":0.9758999943733215,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9714999794960022,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12205","display_name":"Time Series Analysis and Forecasting","score":0.9702000021934509,"subfield":{"id":"https://openalex.org/subfields/1711","display_name":"Signal Processing"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ultrasonic-sensor","display_name":"Ultrasonic sensor","score":0.6738777756690979},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6212646961212158},{"id":"https://openalex.org/keywords/condition-monitoring","display_name":"Condition monitoring","score":0.462945818901062},{"id":"https://openalex.org/keywords/detector","display_name":"Detector","score":0.4332961440086365},{"id":"https://openalex.org/keywords/fatigue-testing","display_name":"Fatigue testing","score":0.4280022382736206},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.4261319935321808},{"id":"https://openalex.org/keywords/structural-engineering","display_name":"Structural engineering","score":0.28929758071899414},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.2854030728340149},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.20328351855278015},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.08361396193504333}],"concepts":[{"id":"https://openalex.org/C81288441","wikidata":"https://www.wikidata.org/wiki/Q20736125","display_name":"Ultrasonic sensor","level":2,"score":0.6738777756690979},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6212646961212158},{"id":"https://openalex.org/C2775846686","wikidata":"https://www.wikidata.org/wiki/Q643012","display_name":"Condition monitoring","level":2,"score":0.462945818901062},{"id":"https://openalex.org/C94915269","wikidata":"https://www.wikidata.org/wiki/Q1834857","display_name":"Detector","level":2,"score":0.4332961440086365},{"id":"https://openalex.org/C2985278600","wikidata":"https://www.wikidata.org/wiki/Q65051469","display_name":"Fatigue testing","level":2,"score":0.4280022382736206},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4261319935321808},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.28929758071899414},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.2854030728340149},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.20328351855278015},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.08361396193504333},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/acc.2007.4282229","is_oa":false,"landing_page_url":"https://doi.org/10.1109/acc.2007.4282229","pdf_url":null,"source":{"id":"https://openalex.org/S4210168941","display_name":"Proceedings of the ... American Control Conference/Proceedings of the American Control Conference","issn_l":"0743-1619","issn":["0743-1619","2378-5861"],"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2007 American Control Conference","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":14,"referenced_works":["https://openalex.org/W197629363","https://openalex.org/W1988413436","https://openalex.org/W2008178166","https://openalex.org/W2047974759","https://openalex.org/W2056985286","https://openalex.org/W2065689967","https://openalex.org/W2098703540","https://openalex.org/W2115755118","https://openalex.org/W2141514928","https://openalex.org/W2150143071","https://openalex.org/W2169739344","https://openalex.org/W3151200052","https://openalex.org/W4252103803","https://openalex.org/W4253184530"],"related_works":["https://openalex.org/W2366906938","https://openalex.org/W2349391998","https://openalex.org/W4205655149","https://openalex.org/W2618703391","https://openalex.org/W2000775715","https://openalex.org/W2361945759","https://openalex.org/W1934323445","https://openalex.org/W2349331384","https://openalex.org/W2033547812","https://openalex.org/W2011628206"],"abstract_inverted_index":{"The":[0,75],"paper":[1,27],"addresses":[2],"the":[3,26,59],"issues":[4],"of":[5,9,21,36,49,67,72],"diagnosis":[6],"and":[7,63,98],"prognosis":[8],"fatigue":[10,38,50,61,88],"failure":[11],"in":[12,40],"mechanical":[13,68],"systems":[14],"using":[15,43],"symbolic":[16],"time":[17],"series":[18],"analysis":[19,31],"(STSA)":[20],"ultrasonic":[22,95],"sensor":[23],"data.":[24],"Specifically,":[25],"presents":[28],"a":[29,86],"statistical":[30],"procedure":[32],"for":[33,57,70],"online":[34],"estimation":[35],"remaining":[37],"life":[39,64],"polycrystalline":[41],"alloys":[42],"STSA-based":[44],"information":[45,54],"from":[46],"an":[47,99],"ensemble":[48],"experiments.":[51],"This":[52],"real-time":[53],"is":[55,77,92],"useful":[56],"monitoring":[58],"evolving":[60],"damage":[62],"extending":[65],"control":[66],"structures":[69],"prevention":[71],"widespread":[73],"failures.":[74],"concept":[76],"experimentally":[78],"validated":[79],"on":[80,85],"7075-T6":[81],"aluminum":[82],"alloy":[83],"specimens":[84],"special-purpose":[87],"test":[89],"apparatus":[90],"that":[91],"equipped":[93],"with":[94],"flaw":[96],"detectors":[97],"optical":[100],"travelling":[101],"microscope.":[102]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
