{"id":"https://openalex.org/W2145921131","doi":"https://doi.org/10.1109/acc.2005.1470569","title":"Fluidic operational amplifier for mock circulatory systems - simulation and experimental results","display_name":"Fluidic operational amplifier for mock circulatory systems - simulation and experimental results","publication_year":2005,"publication_date":"2005-08-10","ids":{"openalex":"https://openalex.org/W2145921131","doi":"https://doi.org/10.1109/acc.2005.1470569","mag":"2145921131"},"language":"en","primary_location":{"id":"doi:10.1109/acc.2005.1470569","is_oa":false,"landing_page_url":"https://doi.org/10.1109/acc.2005.1470569","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 2005, American Control Conference, 2005.","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5025012457","display_name":"Kwan\u2010Woong Gwak","orcid":"https://orcid.org/0000-0001-9170-3139"},"institutions":[{"id":"https://openalex.org/I2250650973","display_name":"Samsung (South Korea)","ror":"https://ror.org/04w3jy968","country_code":"KR","type":"company","lineage":["https://openalex.org/I2250650973"]}],"countries":["KR"],"is_corresponding":true,"raw_author_name":"K. Gwak","raw_affiliation_strings":["Samsung Electronics Research and Development Center, South Korea"],"affiliations":[{"raw_affiliation_string":"Samsung Electronics Research and Development Center, South Korea","institution_ids":["https://openalex.org/I2250650973"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5054456072","display_name":"Myounggyu D. Noh","orcid":"https://orcid.org/0000-0002-9565-0625"},"institutions":[{"id":"https://openalex.org/I154570441","display_name":"University of California, Santa Barbara","ror":"https://ror.org/02t274463","country_code":"US","type":"education","lineage":["https://openalex.org/I154570441"]},{"id":"https://openalex.org/I196345858","display_name":"Chungnam National University","ror":"https://ror.org/0227as991","country_code":"KR","type":"education","lineage":["https://openalex.org/I196345858"]}],"countries":["KR","US"],"is_corresponding":false,"raw_author_name":"M.D. Noh","raw_affiliation_strings":["Chungnam National University, Daejeon, South Korea","Mechanical and Environmental Engineering Department, University of California,\uc2a0Santa Barbara, CA, USA"],"affiliations":[{"raw_affiliation_string":"Chungnam National University, Daejeon, South Korea","institution_ids":["https://openalex.org/I196345858"]},{"raw_affiliation_string":"Mechanical and Environmental Engineering Department, University of California,\uc2a0Santa Barbara, CA, USA","institution_ids":["https://openalex.org/I154570441"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5110010699","display_name":"Bradley E. Paden","orcid":null},"institutions":[{"id":"https://openalex.org/I154570441","display_name":"University of California, Santa Barbara","ror":"https://ror.org/02t274463","country_code":"US","type":"education","lineage":["https://openalex.org/I154570441"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"B.E. Paden","raw_affiliation_strings":["Department of Mechanical and Environmental Engineering, University of California,\uc2a0Santa Barbara, CA, USA"],"affiliations":[{"raw_affiliation_string":"Department of Mechanical and Environmental Engineering, University of California,\uc2a0Santa Barbara, CA, USA","institution_ids":["https://openalex.org/I154570441"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5048217378","display_name":"James F. Antaki","orcid":"https://orcid.org/0000-0002-5430-7353"},"institutions":[{"id":"https://openalex.org/I74973139","display_name":"Carnegie Mellon University","ror":"https://ror.org/05x2bcf33","country_code":"US","type":"education","lineage":["https://openalex.org/I74973139"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"J.F. Antaki","raw_affiliation_strings":["Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA, USA"],"affiliations":[{"raw_affiliation_string":"Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA, USA","institution_ids":["https://openalex.org/I74973139"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5025012457"],"corresponding_institution_ids":["https://openalex.org/I2250650973"],"apc_list":null,"apc_paid":null,"fwci":0.291,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.64421264,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"20","issue":null,"first_page":"3817","last_page":"3822"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10675","display_name":"Mechanical Circulatory Support Devices","score":0.9983000159263611,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10675","display_name":"Mechanical Circulatory Support Devices","score":0.9983000159263611,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10409","display_name":"Fuel Cells and Related Materials","score":0.9962999820709229,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10663","display_name":"Advanced Battery Technologies Research","score":0.9731000065803528,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fluidics","display_name":"Fluidics","score":0.6013368368148804},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.565576434135437},{"id":"https://openalex.org/keywords/operational-amplifier","display_name":"Operational amplifier","score":0.5039762854576111},{"id":"https://openalex.org/keywords/circulatory-system","display_name":"Circulatory system","score":0.47664889693260193},{"id":"https://openalex.org/keywords/amplifier","display_name":"Amplifier","score":0.45440998673439026},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.36910611391067505},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2886679768562317},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.19901245832443237},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.08343997597694397},{"id":"https://openalex.org/keywords/cmos","display_name":"CMOS","score":0.0802050530910492}],"concepts":[{"id":"https://openalex.org/C132651336","wikidata":"https://www.wikidata.org/wiki/Q185571","display_name":"Fluidics","level":2,"score":0.6013368368148804},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.565576434135437},{"id":"https://openalex.org/C145366948","wikidata":"https://www.wikidata.org/wiki/Q178947","display_name":"Operational amplifier","level":4,"score":0.5039762854576111},{"id":"https://openalex.org/C72859922","wikidata":"https://www.wikidata.org/wiki/Q11068","display_name":"Circulatory system","level":2,"score":0.47664889693260193},{"id":"https://openalex.org/C194257627","wikidata":"https://www.wikidata.org/wiki/Q211554","display_name":"Amplifier","level":3,"score":0.45440998673439026},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.36910611391067505},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2886679768562317},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.19901245832443237},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.08343997597694397},{"id":"https://openalex.org/C46362747","wikidata":"https://www.wikidata.org/wiki/Q173431","display_name":"CMOS","level":2,"score":0.0802050530910492},{"id":"https://openalex.org/C164705383","wikidata":"https://www.wikidata.org/wiki/Q10379","display_name":"Cardiology","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/acc.2005.1470569","is_oa":false,"landing_page_url":"https://doi.org/10.1109/acc.2005.1470569","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 2005, American Control Conference, 2005.","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.8100000023841858}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":20,"referenced_works":["https://openalex.org/W1821539644","https://openalex.org/W2011178855","https://openalex.org/W2025498980","https://openalex.org/W2028194904","https://openalex.org/W2031653900","https://openalex.org/W2047922146","https://openalex.org/W2057782427","https://openalex.org/W2064723154","https://openalex.org/W2119380123","https://openalex.org/W2145921131","https://openalex.org/W2178869586","https://openalex.org/W2413522796","https://openalex.org/W2418080502","https://openalex.org/W2773178750","https://openalex.org/W2971244461","https://openalex.org/W3157876862","https://openalex.org/W4256194675","https://openalex.org/W6715593330","https://openalex.org/W6767725242","https://openalex.org/W6794494635"],"related_works":["https://openalex.org/W1718659621","https://openalex.org/W4322494644","https://openalex.org/W2353476186","https://openalex.org/W1597743150","https://openalex.org/W4315866219","https://openalex.org/W2743184632","https://openalex.org/W4389881140","https://openalex.org/W4241338655","https://openalex.org/W2790243520","https://openalex.org/W2135814299"],"abstract_inverted_index":{"For":[0],"the":[1,7,10,16,43,87,93,122,125],"development":[2,44],"of":[3,9,12,45,78,89,124],"cardiovascular":[4,17],"devices":[5,48],"and":[6,29,52,61,104],"study":[8],"dynamics":[11],"blood":[13],"flow":[14],"through":[15],"system,":[18],"hardware":[19,105],"fluidic":[20,74,94],"models":[21],"are":[22,39,58,62],"commonly":[23],"used":[24],"to":[25,64,98,120],"minimize":[26],"animal":[27],"experiments":[28],"clinical":[30],"trials.":[31],"These":[32],"systems,":[33],"called":[34],"\"mock":[35],"circulatory":[36,118],"systems\"":[37],"(MCS)":[38],"also":[40],"critical":[41],"for":[42,114],"ventricular":[46],"assist":[47],"(VAD).":[49],"The":[50],"passive":[51,131],"active":[53],"elements":[54],"in":[55,66,116],"these":[56],"systems":[57,119],"frequently":[59],"\"hard-plumbed\"":[60],"difficult":[63],"modify":[65],"experimental":[67],"studies.":[68],"Therefore":[69],"we":[70],"propose":[71],"a":[72,79],"novel":[73],"operational":[75],"amplifier":[76],"comprised":[77],"high-gain":[80],"feedback-controlled":[81],"gear":[82],"pump.":[83],"With":[84],"pressure":[85],"being":[86],"analog":[88],"voltage,":[90],"design":[91],"with":[92],"op-amp":[95,100],"is":[96],"analogous":[97],"electrical":[99],"design.":[101],"Initial":[102],"computer":[103],"simulation":[106],"results":[107],"demonstrate":[108],"that":[109],"device":[110],"may":[111],"be":[112],"programmed":[113],"use":[115],"mock":[117],"emulate":[121],"function":[123],"energy":[126],"sources":[127],"(the":[128],"ventricle)":[129],"or":[130],"networks":[132],"(hemodynamic":[133],"loads).":[134]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2019,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
