{"id":"https://openalex.org/W2111893204","doi":"https://doi.org/10.1109/acc.2002.1025365","title":"Detection of induction motor faults-combining signal-based and model-based techniques","display_name":"Detection of induction motor faults-combining signal-based and model-based techniques","publication_year":2002,"publication_date":"2002-01-01","ids":{"openalex":"https://openalex.org/W2111893204","doi":"https://doi.org/10.1109/acc.2002.1025365","mag":"2111893204"},"language":"en","primary_location":{"id":"doi:10.1109/acc.2002.1025365","is_oa":false,"landing_page_url":"https://doi.org/10.1109/acc.2002.1025365","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 2002 American Control Conference (IEEE Cat. No.CH37301)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5017676848","display_name":"A.G. Parlos","orcid":null},"institutions":[{"id":"https://openalex.org/I91045830","display_name":"Texas A&M University","ror":"https://ror.org/01f5ytq51","country_code":"US","type":"education","lineage":["https://openalex.org/I91045830"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"A.G. Parlos","raw_affiliation_strings":["Department of Mechanical Engineering, Texas A and M University, College Station, TX, USA","Dept. of Mech. Eng., Texas A&M Univ., College Station, TX, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Mechanical Engineering, Texas A and M University, College Station, TX, USA","institution_ids":["https://openalex.org/I91045830"]},{"raw_affiliation_string":"Dept. of Mech. Eng., Texas A&M Univ., College Station, TX, USA","institution_ids":["https://openalex.org/I91045830"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5005001225","display_name":"Kyusung Kim","orcid":"https://orcid.org/0000-0003-0999-6759"},"institutions":[{"id":"https://openalex.org/I91045830","display_name":"Texas A&M University","ror":"https://ror.org/01f5ytq51","country_code":"US","type":"education","lineage":["https://openalex.org/I91045830"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Kyusung Kim","raw_affiliation_strings":["Department of Mechanical Engineering, Texas A and M University, College Station, TX, USA","Dept. of Mech. Eng., Texas A&M Univ., College Station, TX, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Mechanical Engineering, Texas A and M University, College Station, TX, USA","institution_ids":["https://openalex.org/I91045830"]},{"raw_affiliation_string":"Dept. of Mech. Eng., Texas A&M Univ., College Station, TX, USA","institution_ids":["https://openalex.org/I91045830"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5109884932","display_name":"Raj Bharadwaj","orcid":null},"institutions":[{"id":"https://openalex.org/I91045830","display_name":"Texas A&M University","ror":"https://ror.org/01f5ytq51","country_code":"US","type":"education","lineage":["https://openalex.org/I91045830"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"R. Bharadwaj","raw_affiliation_strings":["Department of Mechanical Engineering, Texas A and M University, College Station, TX, USA","Dept. of Mech. Eng., Texas A&M Univ., College Station, TX, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Mechanical Engineering, Texas A and M University, College Station, TX, USA","institution_ids":["https://openalex.org/I91045830"]},{"raw_affiliation_string":"Dept. of Mech. Eng., Texas A&M Univ., College Station, TX, USA","institution_ids":["https://openalex.org/I91045830"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.2775,"has_fulltext":false,"cited_by_count":12,"citation_normalized_percentile":{"value":0.80992069,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9957000017166138,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12169","display_name":"Non-Destructive Testing Techniques","score":0.994700014591217,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/induction-motor","display_name":"Induction motor","score":0.8675655126571655},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.5480832457542419},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5231412649154663},{"id":"https://openalex.org/keywords/condition-monitoring","display_name":"Condition monitoring","score":0.507803738117218},{"id":"https://openalex.org/keywords/signal","display_name":"SIGNAL (programming language)","score":0.4936748445034027},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.4575369358062744},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.45320063829421997},{"id":"https://openalex.org/keywords/artificial-neural-network","display_name":"Artificial neural network","score":0.4347347617149353},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.432184636592865},{"id":"https://openalex.org/keywords/mains-electricity","display_name":"Mains electricity","score":0.419971764087677},{"id":"https://openalex.org/keywords/dc-motor","display_name":"DC motor","score":0.41508570313453674},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.38963228464126587},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.14518314599990845},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.1149049699306488}],"concepts":[{"id":"https://openalex.org/C80962145","wikidata":"https://www.wikidata.org/wiki/Q207450","display_name":"Induction motor","level":3,"score":0.8675655126571655},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5480832457542419},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5231412649154663},{"id":"https://openalex.org/C2775846686","wikidata":"https://www.wikidata.org/wiki/Q643012","display_name":"Condition monitoring","level":2,"score":0.507803738117218},{"id":"https://openalex.org/C2779843651","wikidata":"https://www.wikidata.org/wiki/Q7390335","display_name":"SIGNAL (programming language)","level":2,"score":0.4936748445034027},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.4575369358062744},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.45320063829421997},{"id":"https://openalex.org/C50644808","wikidata":"https://www.wikidata.org/wiki/Q192776","display_name":"Artificial neural network","level":2,"score":0.4347347617149353},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.432184636592865},{"id":"https://openalex.org/C184773241","wikidata":"https://www.wikidata.org/wiki/Q387400","display_name":"Mains electricity","level":3,"score":0.419971764087677},{"id":"https://openalex.org/C76684090","wikidata":"https://www.wikidata.org/wiki/Q3842034","display_name":"DC motor","level":2,"score":0.41508570313453674},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.38963228464126587},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.14518314599990845},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.1149049699306488},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/acc.2002.1025365","is_oa":false,"landing_page_url":"https://doi.org/10.1109/acc.2002.1025365","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 2002 American Control Conference (IEEE Cat. No.CH37301)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.4399999976158142,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":7,"referenced_works":["https://openalex.org/W613155140","https://openalex.org/W2060106113","https://openalex.org/W2098039475","https://openalex.org/W2132383137","https://openalex.org/W2169762136","https://openalex.org/W2171592504","https://openalex.org/W6679546357"],"related_works":["https://openalex.org/W2267082454","https://openalex.org/W1986012101","https://openalex.org/W2808272244","https://openalex.org/W4254154279","https://openalex.org/W2004189302","https://openalex.org/W2513110030","https://openalex.org/W2036218083","https://openalex.org/W1980179937","https://openalex.org/W2902511954","https://openalex.org/W2786447778"],"abstract_inverted_index":{"Effective":[0],"detection":[1],"and":[2,16,48,72,74,90,96],"diagnosis":[3,36,65,81],"of":[4,20,79,88],"incipient":[5],"faults":[6,87],"is":[7,38,83],"desirable":[8],"for":[9,40,59],"on-line":[10],"condition":[11],"assessment,":[12],"product":[13],"quality":[14],"assurance":[15],"improved":[17],"operational":[18],"efficiency":[19],"induction":[21,41],"motors":[22,42],"running":[23],"off":[24],"the":[25,60,63,80],"power":[26],"supply":[27],"mains.":[28],"In":[29,53],"this":[30],"paper,":[31],"an":[32],"empirical":[33],"model-based":[34],"fault":[35],"system":[37,66,82],"developed":[39],"using":[43],"recurrent":[44],"dynamic":[45],"neural":[46],"networks":[47],"multiresolution":[49],"signal":[50],"processing":[51],"methods.":[52],"addition":[54],"to":[55],"nameplate":[56],"information":[57],"required":[58],"initial":[61],"set-up,":[62],"proposed":[64],"uses":[67],"measured":[68],"motor":[69,75,86],"terminal":[70],"currents":[71],"voltages,":[73],"speed.":[76],"The":[77],"effectiveness":[78],"demonstrated":[84],"through":[85],"electrical":[89],"mechanical":[91],"origin":[92],"staged":[93],"in":[94],"small":[95],"large":[97],"motors.":[98]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2012,"cited_by_count":2}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
