{"id":"https://openalex.org/W2069160129","doi":"https://doi.org/10.1080/002077200418414","title":"Actuator fault-tolerant control design: Demonstration on a three-tank-system","display_name":"Actuator fault-tolerant control design: Demonstration on a three-tank-system","publication_year":2000,"publication_date":"2000-01-01","ids":{"openalex":"https://openalex.org/W2069160129","doi":"https://doi.org/10.1080/002077200418414","mag":"2069160129"},"language":"en","primary_location":{"id":"doi:10.1080/002077200418414","is_oa":false,"landing_page_url":"https://doi.org/10.1080/002077200418414","pdf_url":null,"source":{"id":"https://openalex.org/S129640837","display_name":"International Journal of Systems Science","issn_l":"0020-7721","issn":["0020-7721","1464-5319"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547"],"host_organization_lineage_names":["Taylor & Francis"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"International Journal of Systems Science","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5048673395","display_name":"Hassan Noura","orcid":"https://orcid.org/0000-0002-2589-5053"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Hassan Noura","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5106184374","display_name":"Didier Theilliol","orcid":"https://orcid.org/0000-0002-1942-0094"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Didier Theilliol","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5107837721","display_name":"Dominique Sauter","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Dominique Sauter","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":5.9481,"has_fulltext":false,"cited_by_count":54,"citation_normalized_percentile":{"value":0.95443627,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":98},"biblio":{"volume":"31","issue":"9","first_page":"1143","last_page":"1155"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10791","display_name":"Advanced Control Systems Optimization","score":0.9979000091552734,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11236","display_name":"Control Systems and Identification","score":0.9872000217437744,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.7696760296821594},{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.6597880125045776},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.6428658962249756},{"id":"https://openalex.org/keywords/fault-tolerance","display_name":"Fault tolerance","score":0.6303712129592896},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.5897789001464844},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.5327833890914917},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.5186752080917358},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.5165859460830688},{"id":"https://openalex.org/keywords/isolation","display_name":"Isolation (microbiology)","score":0.5099667310714722},{"id":"https://openalex.org/keywords/stuck-at-fault","display_name":"Stuck-at fault","score":0.4970457851886749},{"id":"https://openalex.org/keywords/control-reconfiguration","display_name":"Control reconfiguration","score":0.4452039897441864},{"id":"https://openalex.org/keywords/fault-coverage","display_name":"Fault coverage","score":0.41027718782424927},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3682302236557007},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.25174975395202637},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.09905633330345154},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.09042713046073914}],"concepts":[{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.7696760296821594},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.6597880125045776},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.6428658962249756},{"id":"https://openalex.org/C63540848","wikidata":"https://www.wikidata.org/wiki/Q3140932","display_name":"Fault tolerance","level":2,"score":0.6303712129592896},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5897789001464844},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.5327833890914917},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5186752080917358},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.5165859460830688},{"id":"https://openalex.org/C2775941552","wikidata":"https://www.wikidata.org/wiki/Q25212305","display_name":"Isolation (microbiology)","level":2,"score":0.5099667310714722},{"id":"https://openalex.org/C13625343","wikidata":"https://www.wikidata.org/wiki/Q7627418","display_name":"Stuck-at fault","level":4,"score":0.4970457851886749},{"id":"https://openalex.org/C119701452","wikidata":"https://www.wikidata.org/wiki/Q5165881","display_name":"Control reconfiguration","level":2,"score":0.4452039897441864},{"id":"https://openalex.org/C126953365","wikidata":"https://www.wikidata.org/wiki/Q5438152","display_name":"Fault coverage","level":3,"score":0.41027718782424927},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3682302236557007},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.25174975395202637},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.09905633330345154},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.09042713046073914},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C134146338","wikidata":"https://www.wikidata.org/wiki/Q1815901","display_name":"Electronic circuit","level":2,"score":0.0},{"id":"https://openalex.org/C89423630","wikidata":"https://www.wikidata.org/wiki/Q7193","display_name":"Microbiology","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1080/002077200418414","is_oa":false,"landing_page_url":"https://doi.org/10.1080/002077200418414","pdf_url":null,"source":{"id":"https://openalex.org/S129640837","display_name":"International Journal of Systems Science","issn_l":"0020-7721","issn":["0020-7721","1464-5319"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547"],"host_organization_lineage_names":["Taylor & Francis"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"International Journal of Systems Science","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.800000011920929,"display_name":"Peace, Justice and strong institutions","id":"https://metadata.un.org/sdg/16"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2125773633","https://openalex.org/W2563037058","https://openalex.org/W2076462302","https://openalex.org/W2981088687","https://openalex.org/W64633261","https://openalex.org/W2024194466","https://openalex.org/W3148663848","https://openalex.org/W4210447066","https://openalex.org/W2089451342","https://openalex.org/W2791245653"],"abstract_inverted_index":{"Fault-tolerant":[0],"control":[1,4,12,37,59,64],"or":[2,118],"reconfigurable":[3],"systems":[5],"are":[6,126,135],"generally":[7],"based":[8,44],"on":[9,45,86],"a":[10,16,34,57,129],"nominal":[11,63],"law":[13,60,65],"associated":[14],"with":[15,28],"fault":[17,52,71,75,95],"detection":[18,98],"and":[19,33,53,78,96,99,132,137],"isolation":[20],"module.":[21],"A":[22,101],"general":[23],"review":[24],"of":[25,49,56,82,93],"techniques":[26],"dealing":[27],"this":[29,74,83],"problem":[30],"is":[31,39,43,76,104],"given":[32],"new":[35,58],"fault-tolerant":[36],"approach":[38,103],"presented.":[40],"This":[41],"method":[42,84],"the":[46,54,62,70,87,91,94,111],"on-line":[47],"estimation":[48],"an":[50],"eventual":[51],"addition":[55],"to":[61,68,109,121,128],"in":[66,107],"order":[67,108],"reduce":[69],"effect":[72],"once":[73],"detected":[77],"isolated.":[79],"The":[80],"performances":[81,134],"depend":[85],"time":[88],"delay":[89],"between":[90],"occurrence":[92],"its":[97],"isolation.":[100],"modified":[102],"then":[105],"proposed":[106],"avoid":[110],"problems":[112],"generated":[113],"by":[114],"delays,":[115],"false":[116],"alarms":[117],"non-detection":[119],"inherent":[120],"diagnosis":[122],"techniques.":[123],"These":[124],"methods":[125],"applied":[127],"pilot":[130],"plant":[131],"their":[133],"compared":[136],"discussed.":[138]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":6},{"year":2019,"cited_by_count":5},{"year":2018,"cited_by_count":4},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":3},{"year":2014,"cited_by_count":3},{"year":2013,"cited_by_count":2},{"year":2012,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}