{"id":"https://openalex.org/W2167627980","doi":"https://doi.org/10.1007/s10845-010-0488-y","title":"Verification of the indoor GPS system, by comparison with calibrated coordinates and by angular reference","display_name":"Verification of the indoor GPS system, by comparison with calibrated coordinates and by angular reference","publication_year":2010,"publication_date":"2010-12-04","ids":{"openalex":"https://openalex.org/W2167627980","doi":"https://doi.org/10.1007/s10845-010-0488-y","mag":"2167627980"},"language":"en","primary_location":{"id":"doi:10.1007/s10845-010-0488-y","is_oa":false,"landing_page_url":"https://doi.org/10.1007/s10845-010-0488-y","pdf_url":null,"source":{"id":"https://openalex.org/S161464388","display_name":"Journal of Intelligent Manufacturing","issn_l":"0956-5515","issn":["0956-5515","1572-8145"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319900","host_organization_name":"Springer Science+Business Media","host_organization_lineage":["https://openalex.org/P4310319900","https://openalex.org/P4310319965"],"host_organization_lineage_names":["Springer Science+Business Media","Springer Nature"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Intelligent Manufacturing","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://pureportal.coventry.ac.uk/en/publications/08722d74-63ef-4697-8ce2-8780ccf782e1","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5056222530","display_name":"Jody Muelaner","orcid":null},"institutions":[{"id":"https://openalex.org/I51601045","display_name":"University of Bath","ror":"https://ror.org/002h8g185","country_code":"GB","type":"education","lineage":["https://openalex.org/I51601045"]}],"countries":["GB"],"is_corresponding":true,"raw_author_name":"J. E. Muelaner","raw_affiliation_strings":["The University of Bath, Bath, BA2 7AY, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"The University of Bath, Bath, BA2 7AY, UK","institution_ids":["https://openalex.org/I51601045"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5069584227","display_name":"Zheng Wang","orcid":"https://orcid.org/0000-0001-5619-9045"},"institutions":[{"id":"https://openalex.org/I51601045","display_name":"University of Bath","ror":"https://ror.org/002h8g185","country_code":"GB","type":"education","lineage":["https://openalex.org/I51601045"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Z. Wang","raw_affiliation_strings":["The University of Bath, Bath, BA2 7AY, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"The University of Bath, Bath, BA2 7AY, UK","institution_ids":["https://openalex.org/I51601045"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5039819531","display_name":"Olivier J. F. Martin","orcid":"https://orcid.org/0000-0002-9574-3119"},"institutions":[{"id":"https://openalex.org/I51601045","display_name":"University of Bath","ror":"https://ror.org/002h8g185","country_code":"GB","type":"education","lineage":["https://openalex.org/I51601045"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"O. Martin","raw_affiliation_strings":["The University of Bath, Bath, BA2 7AY, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"The University of Bath, Bath, BA2 7AY, UK","institution_ids":["https://openalex.org/I51601045"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5014591889","display_name":"Jafar Jamshidi","orcid":"https://orcid.org/0000-0003-2412-5492"},"institutions":[{"id":"https://openalex.org/I51601045","display_name":"University of Bath","ror":"https://ror.org/002h8g185","country_code":"GB","type":"education","lineage":["https://openalex.org/I51601045"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"J. Jamshidi","raw_affiliation_strings":["The University of Bath, Bath, BA2 7AY, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"The University of Bath, Bath, BA2 7AY, UK","institution_ids":["https://openalex.org/I51601045"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5084089866","display_name":"Paul Maropoulos","orcid":"https://orcid.org/0000-0001-6525-6216"},"institutions":[{"id":"https://openalex.org/I51601045","display_name":"University of Bath","ror":"https://ror.org/002h8g185","country_code":"GB","type":"education","lineage":["https://openalex.org/I51601045"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"P. G. Maropoulos","raw_affiliation_strings":["The University of Bath, Bath, BA2 7AY, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"The University of Bath, Bath, BA2 7AY, UK","institution_ids":["https://openalex.org/I51601045"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5056222530"],"corresponding_institution_ids":["https://openalex.org/I51601045"],"apc_list":{"value":2990,"currency":"USD","value_usd":2990},"apc_paid":null,"fwci":1.5275,"has_fulltext":false,"cited_by_count":32,"citation_normalized_percentile":{"value":0.84433622,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":98},"biblio":{"volume":"23","issue":"6","first_page":"2323","last_page":"2331"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11583","display_name":"Advanced Measurement and Metrology Techniques","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11583","display_name":"Advanced Measurement and Metrology Techniques","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11890","display_name":"Scientific Measurement and Uncertainty Evaluation","score":0.9976999759674072,"subfield":{"id":"https://openalex.org/subfields/1804","display_name":"Statistics, Probability and Uncertainty"},"field":{"id":"https://openalex.org/fields/18","display_name":"Decision Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}},{"id":"https://openalex.org/T14163","display_name":"Astronomical Observations and Instrumentation","score":0.9876999855041504,"subfield":{"id":"https://openalex.org/subfields/2206","display_name":"Computational Mechanics"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/theodolite","display_name":"Theodolite","score":0.8227554559707642},{"id":"https://openalex.org/keywords/global-positioning-system","display_name":"Global Positioning System","score":0.6351344585418701},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.5776407718658447},{"id":"https://openalex.org/keywords/coordinate-measuring-machine","display_name":"Coordinate-measuring machine","score":0.5167062282562256},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.49711182713508606},{"id":"https://openalex.org/keywords/measurement-uncertainty","display_name":"Measurement uncertainty","score":0.4709547460079193},{"id":"https://openalex.org/keywords/coordinate-system","display_name":"Coordinate system","score":0.4675527811050415},{"id":"https://openalex.org/keywords/transmitter","display_name":"Transmitter","score":0.44379839301109314},{"id":"https://openalex.org/keywords/interval","display_name":"Interval (graph theory)","score":0.42265450954437256},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.34287187457084656},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.34091490507125854},{"id":"https://openalex.org/keywords/computer-vision","display_name":"Computer vision","score":0.20137038826942444},{"id":"https://openalex.org/keywords/statistics","display_name":"Statistics","score":0.20032551884651184},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.1902613639831543},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.15839532017707825}],"concepts":[{"id":"https://openalex.org/C46399941","wikidata":"https://www.wikidata.org/wiki/Q181517","display_name":"Theodolite","level":2,"score":0.8227554559707642},{"id":"https://openalex.org/C60229501","wikidata":"https://www.wikidata.org/wiki/Q18822","display_name":"Global Positioning System","level":2,"score":0.6351344585418701},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.5776407718658447},{"id":"https://openalex.org/C2777511293","wikidata":"https://www.wikidata.org/wiki/Q1426871","display_name":"Coordinate-measuring machine","level":2,"score":0.5167062282562256},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.49711182713508606},{"id":"https://openalex.org/C137209882","wikidata":"https://www.wikidata.org/wiki/Q1403517","display_name":"Measurement uncertainty","level":2,"score":0.4709547460079193},{"id":"https://openalex.org/C80551277","wikidata":"https://www.wikidata.org/wiki/Q11210","display_name":"Coordinate system","level":2,"score":0.4675527811050415},{"id":"https://openalex.org/C47798520","wikidata":"https://www.wikidata.org/wiki/Q190157","display_name":"Transmitter","level":3,"score":0.44379839301109314},{"id":"https://openalex.org/C2778067643","wikidata":"https://www.wikidata.org/wiki/Q166507","display_name":"Interval (graph theory)","level":2,"score":0.42265450954437256},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.34287187457084656},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.34091490507125854},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.20137038826942444},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.20032551884651184},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.1902613639831543},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.15839532017707825},{"id":"https://openalex.org/C127162648","wikidata":"https://www.wikidata.org/wiki/Q16858953","display_name":"Channel (broadcasting)","level":2,"score":0.0},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.0},{"id":"https://openalex.org/C114614502","wikidata":"https://www.wikidata.org/wiki/Q76592","display_name":"Combinatorics","level":1,"score":0.0},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.0}],"mesh":[],"locations_count":7,"locations":[{"id":"doi:10.1007/s10845-010-0488-y","is_oa":false,"landing_page_url":"https://doi.org/10.1007/s10845-010-0488-y","pdf_url":null,"source":{"id":"https://openalex.org/S161464388","display_name":"Journal of Intelligent Manufacturing","issn_l":"0956-5515","issn":["0956-5515","1572-8145"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319900","host_organization_name":"Springer Science+Business Media","host_organization_lineage":["https://openalex.org/P4310319900","https://openalex.org/P4310319965"],"host_organization_lineage_names":["Springer Science+Business Media","Springer Nature"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Intelligent Manufacturing","raw_type":"journal-article"},{"id":"pmh:oai:publications.aston.ac.uk:26659","is_oa":false,"landing_page_url":"https://publications.aston.ac.uk/view/author/d2a0b260b38586ddb545b04997e73116.html>","pdf_url":null,"source":{"id":"https://openalex.org/S4306400483","display_name":"Aston Publications Explorer (Aston University)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I169199633","host_organization_name":"Aston University","host_organization_lineage":["https://openalex.org/I169199633"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"acceptedVersion","is_accepted":true,"is_published":false,"raw_source_name":null,"raw_type":"Article"},{"id":"pmh:oai:opus.bath.ac.uk:26426","is_oa":false,"landing_page_url":"http://opus.bath.ac.uk/26426/1/Muelaner_JIM_2011.pdf","pdf_url":"http://opus.bath.ac.uk/26426/1/Muelaner_JIM_2011.pdf","source":{"id":"https://openalex.org/S4306401631","display_name":"The University of Bath Online Publications Store (The University of Bath)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I51601045","host_organization_name":"University of Bath","host_organization_lineage":["https://openalex.org/I51601045"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"Articles"},{"id":"pmh:oai:http://curve.coventry.ac.uk/open/p/oai:037935c6-4210-9a18-ef6a-f7731c9a9cef/1","is_oa":false,"landing_page_url":"http://curve.coventry.ac.uk/open/items/037935c6-4210-9a18-ef6a-f7731c9a9cef/1","pdf_url":null,"source":{"id":"https://openalex.org/S4306401989","display_name":"Coventry University Open Collections (Coventry university)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I73417466","host_organization_name":"Coventry University","host_organization_lineage":["https://openalex.org/I73417466"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"Article"},{"id":"pmh:oai:pure.atira.dk:openaire/08722d74-63ef-4697-8ce2-8780ccf782e1","is_oa":true,"landing_page_url":"https://pureportal.coventry.ac.uk/en/publications/08722d74-63ef-4697-8ce2-8780ccf782e1","pdf_url":null,"source":{"id":"https://openalex.org/S4306402411","display_name":"Pure (Coventry University)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I73417466","host_organization_name":"Coventry University","host_organization_lineage":["https://openalex.org/I73417466"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Muelaner, J E, Wang, Z, Martin, O, Jamshidi, J & Maropoulos, P G 2012, 'Verification of the indoor GPS system, by comparison with calibrated coordinates and by angular reference', Journal of Intelligent Manufacturing, vol. 23, no. 6, pp. 2323-2331. https://doi.org/10.1007/s10845-010-0488-y","raw_type":"info:eu-repo/semantics/article"},{"id":"pmh:oai:pure.atira.dk:publications/08722d74-63ef-4697-8ce2-8780ccf782e1","is_oa":true,"landing_page_url":"https://pureportal.coventry.ac.uk/en/publications/verification-of-the-indoor-gps-system-by-comparison-with-calibrated-coordinates-and-by-angular-reference(08722d74-63ef-4697-8ce2-8780ccf782e1).html","pdf_url":null,"source":{"id":"https://openalex.org/S4306402411","display_name":"Pure (Coventry University)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I73417466","host_organization_name":"Coventry University","host_organization_lineage":["https://openalex.org/I73417466"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Muelaner, J E, Wang, Z, Martin, O, Jamshidi, J & Maropoulos, P G 2012, 'Verification of the indoor GPS system, by comparison with calibrated coordinates and by angular reference', Journal of Intelligent Manufacturing, vol. 23, no. 6, pp. 2323-2331. https://doi.org/10.1007/s10845-010-0488-y","raw_type":"info:eu-repo/semantics/article"},{"id":"pmh:oai:purehost.bath.ac.uk:publications/3d364004-5da3-4de2-9e50-87bc90815094","is_oa":false,"landing_page_url":"https://researchportal.bath.ac.uk/en/publications/3d364004-5da3-4de2-9e50-87bc90815094","pdf_url":null,"source":{"id":"https://openalex.org/S4377196294","display_name":"Pure (University of Bath)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I51601045","host_organization_name":"University of Bath","host_organization_lineage":["https://openalex.org/I51601045"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":""}],"best_oa_location":{"id":"pmh:oai:pure.atira.dk:openaire/08722d74-63ef-4697-8ce2-8780ccf782e1","is_oa":true,"landing_page_url":"https://pureportal.coventry.ac.uk/en/publications/08722d74-63ef-4697-8ce2-8780ccf782e1","pdf_url":null,"source":{"id":"https://openalex.org/S4306402411","display_name":"Pure (Coventry University)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I73417466","host_organization_name":"Coventry University","host_organization_lineage":["https://openalex.org/I73417466"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Muelaner, J E, Wang, Z, Martin, O, Jamshidi, J & Maropoulos, P G 2012, 'Verification of the indoor GPS system, by comparison with calibrated coordinates and by angular reference', Journal of Intelligent Manufacturing, vol. 23, no. 6, pp. 2323-2331. https://doi.org/10.1007/s10845-010-0488-y","raw_type":"info:eu-repo/semantics/article"},"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G7488359200","display_name":null,"funder_award_id":"EP/E00184X/1","funder_id":"https://openalex.org/F4320334627","funder_display_name":"Engineering and Physical Sciences Research Council"}],"funders":[{"id":"https://openalex.org/F4320334627","display_name":"Engineering and Physical Sciences Research Council","ror":"https://ror.org/0439y7842"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":17,"referenced_works":["https://openalex.org/W293149846","https://openalex.org/W1554311993","https://openalex.org/W1882240345","https://openalex.org/W1979449810","https://openalex.org/W1981942456","https://openalex.org/W2001394702","https://openalex.org/W2033226899","https://openalex.org/W2054662219","https://openalex.org/W2074603608","https://openalex.org/W2081374807","https://openalex.org/W2084955675","https://openalex.org/W2109721906","https://openalex.org/W2124313187","https://openalex.org/W4239021801","https://openalex.org/W4248245878","https://openalex.org/W4403340453","https://openalex.org/W6678941962"],"related_works":["https://openalex.org/W2057864726","https://openalex.org/W2358950976","https://openalex.org/W2108980705","https://openalex.org/W2040657385","https://openalex.org/W2073265318","https://openalex.org/W4205815119","https://openalex.org/W2102404685","https://openalex.org/W2174910901","https://openalex.org/W2185855723","https://openalex.org/W2267843076"],"abstract_inverted_index":null,"counts_by_year":[{"year":2025,"cited_by_count":4},{"year":2024,"cited_by_count":4},{"year":2023,"cited_by_count":2},{"year":2021,"cited_by_count":4},{"year":2020,"cited_by_count":3},{"year":2019,"cited_by_count":2},{"year":2017,"cited_by_count":3},{"year":2016,"cited_by_count":2},{"year":2015,"cited_by_count":3},{"year":2014,"cited_by_count":2},{"year":2013,"cited_by_count":1},{"year":2012,"cited_by_count":2}],"updated_date":"2026-08-18T07:49:30.821534","created_date":"2025-10-10T00:00:00"}
