{"id":"https://openalex.org/W97339179","doi":null,"title":"R32 And HFOs As Low-GWP Refrigerants For Air Conditioning","display_name":"R32 And HFOs As Low-GWP Refrigerants For Air Conditioning","alternate_titles":[],"publication_year":2012,"publication_date":"2012-07-16","ids":{"openalex":"https://openalex.org/W97339179","mag":"97339179"},"language":"en","primary_location":{"id":"pmh:oai:docs.lib.purdue.edu:iracc-2234","doi":null,"is_oa":true,"landing_page_url":"https://docs.lib.purdue.edu/iracc/1235","pdf_url":"https://docs.lib.purdue.edu/context/iracc/article/2234/viewcontent/2262.pdf","source":{"id":"https://openalex.org/S4377196310","display_name":"Purdue e-Pubs (Purdue University System)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I2801333002","host_organization_name":"Purdue University System","host_organization_lineage":["https://openalex.org/I2801333002"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"International Refrigeration and Air Conditioning Conference","raw_type":"text"},"parent_works":[],"lineage":["https://openalex.org/W97339179"],"child_works_count":0,"pull_notice_works":[],"type":"conference-paper","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://docs.lib.purdue.edu/context/iracc/article/2234/viewcontent/2262.pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5055767765","display_name":"Hung M. Pham","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Hung M. Pham","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5114260142","display_name":"Rajan Rajendran","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Rajan Rajendran","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":12.5706,"has_fulltext":true,"cited_by_count":63,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.99089781,"is_in_top_1_percent":true,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":86,"max":99},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11774","display_name":"Adsorption and Cooling Systems","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10402","display_name":"Phase Equilibria and Thermodynamics","score":0.0,"subfield":{"id":"https://openalex.org/subfields/1606","display_name":"Physical and Theoretical Chemistry"},"field":{"id":"https://openalex.org/fields/16","display_name":"Chemistry"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/r32","display_name":"R32","score":0.9760000109672546},{"id":"https://openalex.org/keywords/hydrofluoroolefins","display_name":"hydrofluoroolefins","score":0.8870000243186951},{"id":"https://openalex.org/keywords/low-gwp-refrigerants","display_name":"low-GWP refrigerants","score":0.8769999742507935},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"air conditioning","score":0.7670000195503235},{"id":"https://openalex.org/keywords/life-cycle-climate-performance","display_name":"life cycle climate performance","score":0.8960000276565552},{"id":"https://openalex.org/keywords/scroll-compressor","display_name":"scroll compressor","score":0.6809999942779541},{"id":"https://openalex.org/keywords/compressor-discharge-temperature","display_name":"compressor discharge temperature","score":0.8080000281333923},{"id":"https://openalex.org/keywords/refrigerant-safety","display_name":"refrigerant safety","score":0.5440000295639038},{"id":"https://openalex.org/keywords/system-efficiency","display_name":"system efficiency","score":0.5270000100135803},{"id":"https://openalex.org/keywords/refrigerant-charge","display_name":"refrigerant charge","score":0.4440000057220459},{"id":"https://openalex.org/keywords/energy-efficiency-standards","display_name":"energy efficiency standards","score":0.5400000214576721}],"concepts":[{"id":"https://openalex.org/C199499590","wikidata":"https://www.wikidata.org/wiki/Q266790","display_name":"Refrigerant","level":3,"score":0.7456231117248535},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.5952455997467041},{"id":"https://openalex.org/C45262634","wikidata":"https://www.wikidata.org/wiki/Q5159291","display_name":"Conditioning","level":2,"score":0.5041977167129517},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.4901047646999359},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.259216845035553},{"id":"https://openalex.org/C131097465","wikidata":"https://www.wikidata.org/wiki/Q178898","display_name":"Gas compressor","level":2,"score":0.16346248984336853},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.13398268818855286},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.11398312449455261},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.07913735508918762}],"mesh":[],"locations_count":2,"locations":[{"id":"pmh:oai:docs.lib.purdue.edu:iracc-2234","doi":null,"is_oa":true,"landing_page_url":"https://docs.lib.purdue.edu/iracc/1235","pdf_url":"https://docs.lib.purdue.edu/context/iracc/article/2234/viewcontent/2262.pdf","source":{"id":"https://openalex.org/S4377196310","display_name":"Purdue e-Pubs (Purdue University System)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I2801333002","host_organization_name":"Purdue University System","host_organization_lineage":["https://openalex.org/I2801333002"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"International Refrigeration and Air Conditioning Conference","raw_type":"text"},{"id":"mag:97339179","doi":null,"is_oa":false,"landing_page_url":"https://docs.lib.purdue.edu/cgi/viewcontent.cgi?article=2234&context=iracc","pdf_url":null,"source":{"id":"https://openalex.org/S4306498081","display_name":"International Refrigeration and Air Conditioning Conference at Purdue","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.","raw_type":null}],"best_oa_location":{"id":"pmh:oai:docs.lib.purdue.edu:iracc-2234","doi":null,"is_oa":true,"landing_page_url":"https://docs.lib.purdue.edu/iracc/1235","pdf_url":"https://docs.lib.purdue.edu/context/iracc/article/2234/viewcontent/2262.pdf","source":{"id":"https://openalex.org/S4377196310","display_name":"Purdue e-Pubs (Purdue University System)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I2801333002","host_organization_name":"Purdue University System","host_organization_lineage":["https://openalex.org/I2801333002"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"International Refrigeration and Air Conditioning Conference","raw_type":"text"},"sustainable_development_goals":[{"score":0.685699999332428,"display_name":"Climate action","id":"https://metadata.un.org/sdg/13"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W97339179.pdf","grobid_xml":"https://content.openalex.org/works/W97339179.grobid-xml"},"referenced_works_count":12,"referenced_works":["https://openalex.org/W45543078","https://openalex.org/W1495885238","https://openalex.org/W1578591353","https://openalex.org/W1601378183","https://openalex.org/W2181297573","https://openalex.org/W2186147141","https://openalex.org/W2318701008","https://openalex.org/W3027770515","https://openalex.org/W3035937316","https://openalex.org/W3036917467","https://openalex.org/W3041266584","https://openalex.org/W7043475589"],"related_works":["https://openalex.org/W4367058044","https://openalex.org/W2591097762","https://openalex.org/W2620589257","https://openalex.org/W3035590606","https://openalex.org/W3032842859","https://openalex.org/W2943311190","https://openalex.org/W3090012794","https://openalex.org/W4221002388","https://openalex.org/W6996742885","https://openalex.org/W3153067024"],"abstract_inverted_index":{"This":[0,96],"paper":[1,97],"will":[2,128,156],"review":[3],"the":[4,42,62,103,161],"status":[5],"worldwide":[6],"on":[7,32,100],"technical":[8],"and":[9,22,41,59,88,92,113,125,133],"policy":[10],"search":[11],"for":[12,35,106,145],"next-generation":[13],"refrigerants":[14],"with":[15,29,121],"both":[16],"low":[17,23],"Global":[18,53],"Warming":[19,54],"Potential":[20,55],"(LGWP)":[21],"Life":[24],"Cycle":[25],"Climate":[26],"Performance":[27],"(LCCP)":[28],"particular":[30],"focus":[31],"R410A":[33],"replacement":[34],"unitary":[36],"A/C":[37],"&":[38],"H/P.":[39],"R32":[40,101,132],"HFO":[43,107,134],"blends":[44,108,135],"offer":[45],"potential":[46],"solutions":[47],"but":[48],"all":[49],"involve":[50],"tradeoffs":[51],"among":[52],"(GWP),":[56],"efficiency,":[57],"safety,":[58],"cost.":[60],"With":[61],"U.S.":[63],"mandating":[64],"new":[65],"higher":[66],"regional":[67],"efficiency":[68,91],"standard":[69],"taking":[70],"effect":[71],"January":[72],"2015,":[73],"there":[74],"is":[75,86,109],"even":[76],"more":[77,99],"pressure":[78],"in":[79],"finding":[80],"a":[81],"Low-GWP":[82],"refrigerant":[83],"solution":[84],"that":[85],"affordable":[87],"can":[89],"sustain":[90],"reduce":[93],"charge":[94],"requirement.":[95],"focuses":[98],"as":[102,149,151],"available":[104],"data":[105],"limited.":[110],"Theoretical":[111],"analyses":[112],"test":[114],"results":[115],"from":[116],"various":[117],"drop-in":[118],"system":[119,139],"tests":[120],"different":[122],"heat":[123],"exchangers":[124],"scroll":[126],"compressors":[127],"be":[129,157],"presented":[130],"comparing":[131],"versus":[136],"R410A.":[137],"LCCP,":[138],"economics,":[140],"compressor":[141],"discharge":[142],"temperature":[143],"envelopes":[144],"typical":[146],"US":[147],"applications,":[148],"well":[150],"A2L":[152],"flammability":[153],"safety":[154],"aspects":[155],"discussed":[158],"relative":[159],"to":[160],"HFOs.":[162]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W97339179","counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2025,"cited_by_count":3},{"year":2024,"cited_by_count":4},{"year":2023,"cited_by_count":4},{"year":2022,"cited_by_count":6},{"year":2021,"cited_by_count":6},{"year":2020,"cited_by_count":6},{"year":2019,"cited_by_count":5},{"year":2018,"cited_by_count":2},{"year":2017,"cited_by_count":4},{"year":2016,"cited_by_count":9},{"year":2015,"cited_by_count":5},{"year":2014,"cited_by_count":5},{"year":2013,"cited_by_count":1},{"year":2012,"cited_by_count":1}],"updated_date":"2026-11-23T12:01:36.302904","created_date":"2016-06-24T00:00:00"}
