{"id":"https://openalex.org/W97200943","doi":null,"title":"Air and pollutant movement in a building can be evaluated using CO as a surrogate","display_name":"Air and pollutant movement in a building can be evaluated using CO as a surrogate","publication_year":1990,"publication_date":"1990-01-01","ids":{"openalex":"https://openalex.org/W97200943","mag":"97200943"},"language":"en","primary_location":{"id":"mag:97200943","doi":null,"is_oa":false,"landing_page_url":"http://www.osti.gov/scitech/biblio/6448767-air-pollutant-movement-building-can-evaluated-using-co-surrogate","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5108280938","display_name":"Jackson","orcid":"https://orcid.org/0000-0002-2802-6152","observed_orcids":["https://orcid.org/0000-0002-2802-6152","https://orcid.org/0000-0002-5520-2190"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Jackson","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5109211314","display_name":"L.E. Sparks","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"L.E. Sparks","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5016080454","display_name":"B.A. Tichenor","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"B.A. Tichenor","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":null,"display_name":"Z. Guo","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Z. Guo","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":null,"display_name":"K. Krebs","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"K. Krebs","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.01313658,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11002","display_name":"Indoor Air Quality and Microbial Exposure","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2307","display_name":"Health, Toxicology and Mutagenesis"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11002","display_name":"Indoor Air Quality and Microbial Exposure","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2307","display_name":"Health, Toxicology and Mutagenesis"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11371","display_name":"Wind and Air Flow Studies","score":0.0005000000237487257,"subfield":{"id":"https://openalex.org/subfields/2305","display_name":"Environmental Engineering"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10990","display_name":"Infection Control and Ventilation","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2740","display_name":"Pulmonary and Respiratory Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/carbon-monoxide-tracer","display_name":"carbon monoxide tracer","score":0.777999997138977},{"id":"https://openalex.org/keywords/indoor-airflow","display_name":"indoor airflow","score":0.7120000123977661},{"id":"https://openalex.org/keywords/pollutant-distribution","display_name":"pollutant distribution","score":0.5799999833106995},{"id":"https://openalex.org/keywords/aerosol-products","display_name":"aerosol products","score":0.753000020980835},{"id":"https://openalex.org/keywords/indoor-air-quality","display_name":"indoor air quality","score":0.6690000295639038},{"id":"https://openalex.org/keywords/tetrachloroethylene","display_name":"tetrachloroethylene","score":0.843999981880188},{"id":"https://openalex.org/keywords/bathroom-ventilation","display_name":"bathroom ventilation","score":0.6039999723434448},{"id":"https://openalex.org/keywords/test-house","display_name":"test house","score":0.515999972820282}],"concepts":[{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.6867718696594238},{"id":"https://openalex.org/C2779345167","wikidata":"https://www.wikidata.org/wiki/Q104541","display_name":"Aerosol","level":2,"score":0.6786903738975525},{"id":"https://openalex.org/C82685317","wikidata":"https://www.wikidata.org/wiki/Q19829510","display_name":"Pollutant","level":2,"score":0.6101840138435364},{"id":"https://openalex.org/C65469","wikidata":"https://www.wikidata.org/wiki/Q905504","display_name":"Indoor air quality","level":2,"score":0.572239875793457},{"id":"https://openalex.org/C125209513","wikidata":"https://www.wikidata.org/wiki/Q4037520","display_name":"Doors","level":2,"score":0.5408802628517151},{"id":"https://openalex.org/C548081761","wikidata":"https://www.wikidata.org/wiki/Q180388","display_name":"Waste management","level":1,"score":0.46743813157081604},{"id":"https://openalex.org/C87717796","wikidata":"https://www.wikidata.org/wiki/Q146326","display_name":"Environmental engineering","level":1,"score":0.43674591183662415},{"id":"https://openalex.org/C512735826","wikidata":"https://www.wikidata.org/wiki/Q2025","display_name":"Carbon monoxide","level":3,"score":0.42291563749313354},{"id":"https://openalex.org/C107872376","wikidata":"https://www.wikidata.org/wiki/Q321355","display_name":"Environmental chemistry","level":1,"score":0.3951694965362549},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.2538939118385315},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.20914313197135925},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.0},{"id":"https://openalex.org/C178790620","wikidata":"https://www.wikidata.org/wiki/Q11351","display_name":"Organic chemistry","level":1,"score":0.0},{"id":"https://openalex.org/C161790260","wikidata":"https://www.wikidata.org/wiki/Q82264","display_name":"Catalysis","level":2,"score":0.0},{"id":"https://openalex.org/C55493867","wikidata":"https://www.wikidata.org/wiki/Q7094","display_name":"Biochemistry","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:97200943","doi":null,"is_oa":false,"landing_page_url":"http://www.osti.gov/scitech/biblio/6448767-air-pollutant-movement-building-can-evaluated-using-co-surrogate","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W7018425099","https://openalex.org/W2886123528","https://openalex.org/W4294550806","https://openalex.org/W1968555719","https://openalex.org/W4387455392","https://openalex.org/W2338534777","https://openalex.org/W2231318213","https://openalex.org/W2547830829","https://openalex.org/W2757723049","https://openalex.org/W2610495991"],"abstract_inverted_index":{"The":[0,127,148,168,177],"paper":[1],"discusses":[2],"tracer":[3],"tests":[4],"conducted":[5],"to":[6,16,45,55,129],"determine":[7],"how":[8,188],"indoor":[9,22,68],"conditions":[10,162],"may":[11],"affect":[12],"pollutant":[13],"levels,":[14],"prior":[15],"initiating":[17],"a":[18,58,82,97,118,133,139,194],"study":[19,183],"of":[20,24,36,60,81,112,115,170,179,187],"the":[21,79,89,102,113,158,165,180,185],"use":[23,30,130],"aerosol":[25,50],"products.":[26,51],"(NOTE:":[27],"Aerosol":[28],"product":[29,149],"indoors":[31],"can":[32,191],"cause":[33],"elevated":[34],"concentrations":[35],"vapor-phase":[37],"organic":[38],"compounds.)":[39],"Carbon":[40],"monoxide":[41],"(CO)":[42],"was":[43,76,91,121,135,150,172],"chosen":[44],"represent":[46],"gas-phase":[47],"emissions":[48],"from":[49],"CO":[52,75,86,116,131,166,190],"is":[53],"easy":[54],"monitor":[56],"over":[57],"range":[59],"0-200":[61],"ppm,":[62],"and":[63,85,108,155,161,184],"background":[64],"levels":[65],"expected":[66],"in":[67,78,122,157,164],"environments":[69],"are":[70,196],"quite":[71],"low":[72],"(<1-3":[73],"ppm).":[74],"released":[77,156],"bathroom":[80,98],"test":[83],"house,":[84],"distribution":[87,169],"throughout":[88],"house":[90],"followed":[92,173],"under":[93],"several":[94],"scenarios,":[95],"including:":[96],"vent":[99],"fan":[100,104],"on/off,":[101,105],"furnace":[103],"doors":[106],"open/closed,":[107],"windows":[109],"open/closed.":[110],"Because":[111],"concentration":[114],"used,":[117],"safety":[119],"plan":[120],"effect":[123],"during":[124],"all":[125],"tests.":[126,167],"ability":[128],"as":[132,193],"surrogate":[134,195],"evaluated":[136],"by":[137],"using":[138,174],"commercially":[140],"available":[141],"home":[142],"spot":[143],"remover":[144],"containing":[145],"perchloroethylene":[146],"(perc).":[147],"used":[151,163],"per":[152],"package":[153],"directions":[154],"same":[159],"location":[160],"perc":[171],"gas":[175],"chromatography.":[176],"results":[178],"air":[181],"movement":[182],"evaluation":[186],"well":[189],"serve":[192],"presented.":[197]},"counts_by_year":[],"updated_date":"2026-11-05T12:25:35.769452","created_date":"2016-06-24T00:00:00"}
