{"id":"https://openalex.org/W94006283","doi":null,"title":"Development of Low Global Warming Potential Refrigerant Solutions for Commercial Refrigeration Systems using a Life Cycle Climate Performance Design Tool","display_name":"Development of Low Global Warming Potential Refrigerant Solutions for Commercial Refrigeration Systems using a Life Cycle Climate Performance Design Tool","alternate_titles":[],"publication_year":2012,"publication_date":"2012-07-16","ids":{"openalex":"https://openalex.org/W94006283","mag":"94006283"},"language":"en","primary_location":{"id":"pmh:oai:docs.lib.purdue.edu:iracc-2352","doi":null,"is_oa":false,"landing_page_url":"https://docs.lib.purdue.edu/iracc/1353","pdf_url":null,"source":{"id":"https://openalex.org/S4377196310","display_name":"Purdue e-Pubs (Purdue University System)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I2801333002","host_organization_name":"Purdue University System","host_organization_lineage":["https://openalex.org/I2801333002"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"International Refrigeration and Air Conditioning Conference","raw_type":"text"},"parent_works":[],"lineage":["https://openalex.org/W94006283"],"child_works_count":0,"pull_notice_works":[],"type":"conference-paper","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5078161269","display_name":"Omar A. Abdelaziz","type":null,"orcid":"https://orcid.org/0000-0002-4418-0125","observed_orcids":["https://orcid.org/0000-0002-4418-0125"]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Omar Abdelaziz","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5006407180","display_name":"Brian Albert Fricke","type":null,"orcid":"https://orcid.org/0000-0001-8197-3477","observed_orcids":["https://orcid.org/0000-0001-8197-3477"]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Brian Fricke","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5114374220","display_name":"E.A. Vineyard","type":null,"orcid":"https://orcid.org/0000-0003-4695-7441","observed_orcids":["https://orcid.org/0000-0003-4695-7441"]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"E.A. Vineyard","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":4.1902,"has_fulltext":false,"cited_by_count":12,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.9196761,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":86,"max":96},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11774","display_name":"Adsorption and Cooling Systems","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/low-gwp-refrigerants","display_name":"low-GWP refrigerants","score":0.9070000052452087},{"id":"https://openalex.org/keywords/commercial-refrigeration-systems","display_name":"commercial refrigeration systems","score":0.9860000014305115},{"id":"https://openalex.org/keywords/life-cycle-climate-performance","display_name":"life cycle climate performance","score":0.9900000095367432}],"concepts":[{"id":"https://openalex.org/C199499590","wikidata":"https://www.wikidata.org/wiki/Q266790","display_name":"Refrigerant","level":3,"score":0.9360363483428955},{"id":"https://openalex.org/C69907114","wikidata":"https://www.wikidata.org/wiki/Q747713","display_name":"Refrigeration","level":2,"score":0.7487437725067139},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.6697049140930176},{"id":"https://openalex.org/C36570524","wikidata":"https://www.wikidata.org/wiki/Q615475","display_name":"Vapor-compression refrigeration","level":4,"score":0.5809198021888733},{"id":"https://openalex.org/C4638862","wikidata":"https://www.wikidata.org/wiki/Q1501558","display_name":"Chiller","level":2,"score":0.5128612518310547},{"id":"https://openalex.org/C21880701","wikidata":"https://www.wikidata.org/wiki/Q2144042","display_name":"Process engineering","level":1,"score":0.48683494329452515},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.4625489115715027},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.449365496635437},{"id":"https://openalex.org/C115343472","wikidata":"https://www.wikidata.org/wiki/Q7942","display_name":"Global warming","level":3,"score":0.4201889932155609},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.41432827711105347},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3631187081336975},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.32467126846313477},{"id":"https://openalex.org/C132651083","wikidata":"https://www.wikidata.org/wiki/Q7942","display_name":"Climate change","level":2,"score":0.2586766183376312},{"id":"https://openalex.org/C107706546","wikidata":"https://www.wikidata.org/wiki/Q189124","display_name":"Heat exchanger","level":2,"score":0.18964403867721558},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.1330130696296692},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.09363895654678345},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C18903297","wikidata":"https://www.wikidata.org/wiki/Q7150","display_name":"Ecology","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"pmh:oai:docs.lib.purdue.edu:iracc-2352","doi":null,"is_oa":false,"landing_page_url":"https://docs.lib.purdue.edu/iracc/1353","pdf_url":null,"source":{"id":"https://openalex.org/S4377196310","display_name":"Purdue e-Pubs (Purdue University System)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I2801333002","host_organization_name":"Purdue University System","host_organization_lineage":["https://openalex.org/I2801333002"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"International Refrigeration and Air Conditioning Conference","raw_type":"text"},{"id":"mag:94006283","doi":null,"is_oa":false,"landing_page_url":"https://docs.lib.purdue.edu/cgi/viewcontent.cgi?article=2352&context=iracc","pdf_url":null,"source":{"id":"https://openalex.org/S4306498081","display_name":"International Refrigeration and Air Conditioning Conference at Purdue","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"score":1.0,"display_name":"Climate action","id":"https://metadata.un.org/sdg/13"},{"score":0.7811999917030334,"display_name":"Responsible consumption and production","id":"https://metadata.un.org/sdg/12"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":3,"referenced_works":["https://openalex.org/W2034314604","https://openalex.org/W2052373076","https://openalex.org/W2317092132"],"related_works":["https://openalex.org/W3029338333","https://openalex.org/W2297743333","https://openalex.org/W109692167","https://openalex.org/W2507768565","https://openalex.org/W2120073535","https://openalex.org/W641194507","https://openalex.org/W3035283949","https://openalex.org/W2463369958","https://openalex.org/W4317470328","https://openalex.org/W2005029505"],"abstract_inverted_index":{"Commercial":[0],"refrigeration":[1,64,160,214],"systems":[2],"are":[3,120,165],"known":[4],"to":[5,8,13,26,40,56,73,86,146,168,191],"be":[6,206,220],"prone":[7],"high":[9],"leak":[10],"rates":[11,145],"and":[12,29,69,99,117,175,237,256],"consume":[14],"large":[15],"amounts":[16],"of":[17,60,151],"electricity.":[18],"As":[19],"such,":[20,239],"both":[21],"the":[22,30,58,138,184,195,250],"direct":[23,169],"emissions":[24,32,164,170,197],"related":[25],"refrigerant":[27,80,173,253],"leakage":[28],"indirect":[31,152,196],"resulting":[33],"from":[34,122],"primary":[35],"energy":[36,127],"consumption":[37],"contribute":[38],"greatly":[39],"their":[41],"Life":[42],"Cycle":[43],"Climate":[44],"Performance":[45],"(LCCP).":[46],"In":[47],"this":[48],"paper,":[49],"an":[50,148],"LCCP":[51,84,90,132],"design":[52,91,133],"tool":[53,92,113,129,134],"is":[54,104],"used":[55,125],"evaluate":[57],"performance":[59,103],"a":[61,107,123,180,188,230,246],"typical":[62],"commercial":[63,159,213],"system":[65,71,95,100,102,111,118,161,177],"with":[66,82,172,245],"alternative":[67],"refrigerants":[68,203,228,236],"minor":[70],"modifications":[72],"provide":[74],"lower":[75,232],"Global":[76],"Warming":[77],"Potential":[78],"(GWP)":[79],"solutions":[81],"improved":[83,240],"compared":[85],"baseline":[87,235],"systems.":[88],"The":[89,131,154,242],"accounts":[93,136],"for":[94,137,208],"performance,":[96],"ambient":[97,115],"temperature,":[98],"load;":[101],"evaluated":[105],"using":[106],"validated":[108],"vapor":[109],"compression":[110],"simulation":[112],"while":[114],"temperature":[116],"load":[119],"devised":[121],"widely":[124],"building":[126],"modeling":[128],"(EnergyPlus).":[130],"also":[135],"change":[139],"in":[140,183,211],"hourly":[141],"electricity":[142],"CO2":[143],"emission":[144],"yield":[147],"accurate":[149],"prediction":[150],"emissions.":[153],"analysis":[155],"shows":[156],"that":[157,176],"conventional":[158,212],"life":[162],"cycle":[163],"largely":[166],"due":[167],"associated":[171],"leaks":[174],"efficiency":[178,255],"plays":[179],"smaller":[181],"role":[182],"LCCP.":[185,241],"However,":[186],"as":[187,222,238],"transition":[189],"occurs":[190],"low":[192],"GWP":[193,202,233],"refrigerants,":[194],"become":[198],"more":[199],"relevant.":[200],"Low":[201],"may":[204,219],"not":[205],"suitable":[207],"drop-in":[209,224],"replacements":[210],"systems;":[215],"however":[216],"some":[217],"mixtures":[218],"introduced":[221],"transitional":[223,227],"replacements.":[225],"These":[226],"have":[229],"significantly":[231],"than":[234],"paper":[243],"concludes":[244],"brief":[247],"discussion":[248],"on":[249],"tradeoffs":[251],"between":[252],"GWP,":[254],"capacity.":[257]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W94006283","counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":2},{"year":2015,"cited_by_count":3},{"year":2014,"cited_by_count":1}],"updated_date":"2026-11-21T10:27:49.728292","created_date":"2016-06-24T00:00:00"}
