{"id":"https://openalex.org/W920183783","doi":"https://doi.org/10.1049/cp.2011.0590","title":"POSS","display_name":"POSS","alternate_titles":[],"publication_year":2011,"publication_date":"2011-01-01","ids":{"openalex":"https://openalex.org/W920183783","doi":"https://doi.org/10.1049/cp.2011.0590","mag":"920183783"},"language":"en","primary_location":{"id":"doi:10.1049/cp.2011.0590","doi":"https://doi.org/10.1049/cp.2011.0590","is_oa":false,"landing_page_url":"https://doi.org/10.1049/cp.2011.0590","pdf_url":null,"source":{"id":"https://openalex.org/S7407104854","display_name":"IET International Conference on Railway Condition Monitoring (RCM)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4320800662","host_organization_name":"Institution of Electrical Engineers","host_organization_lineage":["https://openalex.org/P4320800662"],"host_organization_lineage_names":["Institution of Electrical Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"5th IET Conference on Railway Condition Monitoring and Non-Destructive Testing (RCM 2011)","raw_type":"proceedings-article"},"parent_works":[],"lineage":["https://openalex.org/W920183783"],"child_works_count":0,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5040655626","display_name":"F.R. Redeker","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4405252620","display_name":"Strukton (Netherlands)","ror":"https://ror.org/03jrc1b82","country_code":"NL","type":"company","lineage":["https://openalex.org/I4405252620"]}],"countries":["NL"],"is_corresponding":true,"contributor_roles":[],"raw_author_name":"F.R. Redeker","raw_affiliation_strings":["Strukton Rail, Netherlands"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Strukton Rail, Netherlands","institution_ids":["https://openalex.org/I4405252620"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5040655626"],"corresponding_institution_ids":["https://openalex.org/I4405252620"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":1,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":87,"max":93},"biblio":{"volume":null,"issue":null,"first_page":"3B2","last_page":"3B2"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T13615","display_name":"Transportation Systems and Safety","score":0.5264000296592712,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T13615","display_name":"Transportation Systems and Safety","score":0.5264000296592712,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.2694999873638153,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10842","display_name":"Railway Engineering and Dynamics","score":0.1599999964237213,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/railway-condition-monitoring","display_name":"railway condition monitoring","score":0.9900000095367432},{"id":"https://openalex.org/keywords/polyhedral-oligomeric-silsesquioxane","display_name":"polyhedral oligomeric silsesquioxane","score":0.5410000085830688},{"id":"https://openalex.org/keywords/data-logger","display_name":"data logger","score":0.7599999904632568},{"id":"https://openalex.org/keywords/alarm-generation","display_name":"alarm generation","score":0.6499999761581421},{"id":"https://openalex.org/keywords/wheel-defect-detection","display_name":"wheel defect detection","score":0.996999979019165},{"id":"https://openalex.org/keywords/track-circuits","display_name":"track circuits","score":0.7850000262260437},{"id":"https://openalex.org/keywords/level-crossings","display_name":"level crossings","score":0.9769999980926514},{"id":"https://openalex.org/keywords/expansion-joints","display_name":"expansion joints","score":0.9629999995231628},{"id":"https://openalex.org/keywords/rail-temperature","display_name":"rail temperature","score":0.8040000200271606},{"id":"https://openalex.org/keywords/rolling-stock-maintenance","display_name":"rolling stock maintenance","score":0.8109999895095825},{"id":"https://openalex.org/keywords/maintenance-cost-reduction","display_name":"maintenance cost reduction","score":0.5479999780654907},{"id":"https://openalex.org/keywords/user-friendly-software","display_name":"user-friendly software","score":0.38499999046325684}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5201990008354187}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1049/cp.2011.0590","doi":"https://doi.org/10.1049/cp.2011.0590","is_oa":false,"landing_page_url":"https://doi.org/10.1049/cp.2011.0590","pdf_url":null,"source":{"id":"https://openalex.org/S7407104854","display_name":"IET International Conference on Railway Condition Monitoring (RCM)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4320800662","host_organization_name":"Institution of Electrical Engineers","host_organization_lineage":["https://openalex.org/P4320800662"],"host_organization_lineage_names":["Institution of Electrical Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"5th IET Conference on Railway Condition Monitoring and Non-Destructive Testing (RCM 2011)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":1.0,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W567578170","https://openalex.org/W820516156","https://openalex.org/W1916681017","https://openalex.org/W1974400615","https://openalex.org/W3143977341","https://openalex.org/W2711537620","https://openalex.org/W3160632097","https://openalex.org/W2891023556","https://openalex.org/W3036163455","https://openalex.org/W6922586293"],"abstract_inverted_index":{"Railway":[0],"Condition":[1,146],"Monitoring":[2,147],"(RCM)":[3],"can":[4,119,176,262,297],"be":[5,116,299],"a":[6,86,129,192,234],"great":[7],"tool":[8,311],"to":[9,94,98,103,115,128,257,264,277,284],"improve":[10],"the":[11,18,28,31,34,37,40,43,48,75,79,96,100,105,111,151,160,167,170,184,220,240,244,248,258,266,269,285,288,316,324,326,332],"availability":[12,131],"of":[13,25,30,39,81,89,113,139,169,180,222,247,268,287,290,318,331],"your":[14],"railways":[15,276],"and":[16,36,63,102,213,225,243,261,322],"lower":[17],"maintenance":[19,76,91,135,231,267],"costs.":[20],"Key":[21],"factor":[22],"for":[23,71,301],"success":[24],"RCM":[26,82,118,154],"is":[27,46,110,149,164,219],"implementation":[29,80],"system":[32,41],"in":[33,74,142,166,323],"organisation":[35],"appreciation":[38],"by":[42,53],"users.":[44],"This":[45,295],"where":[47],"POSS\u00ae":[49,140,198,309],"philosophy":[50],"distinguishes":[51],"itself":[52,122],"its":[54],"special":[55],"approach.":[56],"The":[57,65,137,186,229,251,272],"hardware":[58],"design":[59,168],"focuses":[60,67],"on":[61,68,183,233,239,275],"simplicity":[62],"reliability.":[64],"software":[66,188],"user":[69],"friendliness":[70],"all":[72,302,319],"layers":[73],"organisation.":[77],"For":[78],"Strukton":[83],"Rail":[84,293],"has":[85,282],"large":[87],"number":[88],"experienced":[90],"engineers,":[92],"able":[93],"advise":[95],"management,":[97],"train":[99],"users":[101],"avoid":[104],"usual":[106],"pitfalls.":[107],"Important":[108],"also":[109,298],"selection":[112],"assets":[114,321],"monitored.":[117],"only":[120],"pay":[121],"back":[123],"when":[124],"it":[125],"contributes":[126],"significantly":[127],"higher":[130],"or":[132],"an":[133],"optimised":[134],"process.":[136],"development":[138,289],"started":[141],"1999":[143],"with":[144],"Point":[145],"which":[148],"still":[150],"most":[152],"import":[153],"item.":[155],"All":[156],"experience":[157],"acquired":[158],"over":[159],"last":[161],"12":[162],"years":[163],"used":[165,300],"newest":[171],"MicroPOSS":[172],"data":[173],"loggers":[174],"that":[175],"handle":[177],"any":[178],"type":[179],"point":[181],"drive":[182],"market.":[185],"new":[187,217,252,273],"release":[189],"6.0":[190],"offers":[191],"further":[193],"improved":[194],"alarm":[195],"generation.":[196],"Other":[197],"applications":[199],"include":[200],"monitoring":[201,221],"of:":[202],"track":[203,306],"circuits,":[204],"wheel":[205,226,245],"shunt,":[206],"level":[207],"crossings,":[208],"expansion":[209],"joints,":[210],"rail":[211],"temperature":[212],"rolling":[214,270],"stock.":[215,271],"A":[216,308],"concept":[218,253],"axle":[223,241,280],"loads":[224],"defect":[227],"detection.":[228],"required":[230],"activities":[232],"railway":[235],"line":[236],"strongly":[237],"depend":[238],"load":[242],"defects":[246],"passing":[249],"trains.":[250],"gives":[254,312],"more":[255,279],"transparency":[256],"infra":[259],"manager":[260],"help":[263],"optimize":[265],"trend":[274],"use":[278,330],"counters":[281],"led":[283],"decision":[286],"POSS8'":[291],"Broken":[292],"Detection.":[294],"application":[296],"other":[303],"tracks":[304],"without":[305],"circuits.":[307],"management":[310],"easy":[313],"insight":[314],"into":[315],"quality":[317],"monitored":[320],"way":[325],"several":[327],"regions":[328],"make":[329],"system.":[333],"(5":[334],"pages)":[335]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W920183783","counts_by_year":[{"year":2021,"cited_by_count":1}],"updated_date":"2026-10-28T10:33:24.094632","created_date":"2016-06-24T00:00:00"}
