{"id":"https://openalex.org/W87928357","doi":"https://doi.org/10.1680/hotfs.31685.0007","title":"7. Tunnel ventilation\u2013state of the art","display_name":"7. Tunnel ventilation\u2013state of the art","publication_year":2005,"publication_date":"2005-01-01","ids":{"openalex":"https://openalex.org/W87928357","doi":"https://doi.org/10.1680/hotfs.31685.0007","mag":"87928357"},"language":"en","primary_location":{"id":"doi:10.1680/hotfs.31685.0007","doi":"https://doi.org/10.1680/hotfs.31685.0007","is_oa":false,"landing_page_url":"https://doi.org/10.1680/hotfs.31685.0007","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"The handbook of tunnel fire safety","raw_type":"book-chapter"},"volume":{"id":"https://openalex.org/W37875003","display_name":"The handbook of tunnel fire safety"},"type":"book-chapter","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5084084935","display_name":"A G Bendelius","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Art Bendelius","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5084084935"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":2.8277,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.84482759,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":93},"biblio":{"volume":null,"issue":null,"first_page":"127","last_page":"143"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11317","display_name":"Fire dynamics and safety research","score":0.9940999746322632,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11317","display_name":"Fire dynamics and safety research","score":0.9940999746322632,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11371","display_name":"Wind and Air Flow Studies","score":0.002099999925121665,"subfield":{"id":"https://openalex.org/subfields/2305","display_name":"Environmental Engineering"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11002","display_name":"Indoor Air Quality and Microbial Exposure","score":0.0019000000320374966,"subfield":{"id":"https://openalex.org/subfields/2307","display_name":"Health, Toxicology and Mutagenesis"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/tunnel-ventilation","display_name":"tunnel ventilation","score":0.9990000128746033},{"id":"https://openalex.org/keywords/road-tunnels","display_name":"road tunnels","score":0.9459999799728394},{"id":"https://openalex.org/keywords/metro-tunnels","display_name":"subway tunnels","score":0.5239999890327454},{"id":"https://openalex.org/keywords/mechanical-ventilation","display_name":"mechanical ventilation","score":0.6399999856948853},{"id":"https://openalex.org/keywords/natural-ventilation","display_name":"natural ventilation","score":0.7200000286102295},{"id":"https://openalex.org/keywords/air-quality-control","display_name":"air quality control","score":0.4090000092983246},{"id":"https://openalex.org/keywords/fire-ventilation","display_name":"fire ventilation","score":0.5680000185966492},{"id":"https://openalex.org/keywords/emergency-ventilation","display_name":"emergency ventilation","score":0.6119999885559082},{"id":"https://openalex.org/keywords/ventilation-design","display_name":"ventilation system design","score":0.4790000021457672},{"id":"https://openalex.org/keywords/construction-and-operating-costs","display_name":"construction and operating costs","score":0.5569999814033508}],"concepts":[{"id":"https://openalex.org/C200457457","wikidata":"https://www.wikidata.org/wiki/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.5657544732093811},{"id":"https://openalex.org/C48103436","wikidata":"https://www.wikidata.org/wiki/Q599031","display_name":"State (computer science)","level":2,"score":0.541388213634491},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.34042954444885254},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3047090172767639},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.298101544380188},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.18677827715873718},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.047454774379730225}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1680/hotfs.31685.0007","doi":"https://doi.org/10.1680/hotfs.31685.0007","is_oa":false,"landing_page_url":"https://doi.org/10.1680/hotfs.31685.0007","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"The handbook of tunnel fire safety","raw_type":"book-chapter"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/11","score":0.7250000238418579,"display_name":"Sustainable cities and communities"},{"id":"https://metadata.un.org/sdg/9","score":0.7207000255584717,"display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2071746764","https://openalex.org/W2386600254","https://openalex.org/W2029783260","https://openalex.org/W4231062748","https://openalex.org/W2372853359","https://openalex.org/W2379633736","https://openalex.org/W2064043496","https://openalex.org/W2381131365","https://openalex.org/W2394403838","https://openalex.org/W2365105642"],"abstract_inverted_index":{"The":[0,119],"use":[1],"of":[2,64,95],"the":[3,93,125,137],"term":[4],"tunnel":[5],"in":[6],"this":[7],"paper":[8],"refers":[9],"to":[10,91,100,108],"all":[11],"transportation-related":[12],"tunnels":[13,18,32,71],"including":[14],"highway":[15,31,70],"tunnels,":[16,53],"transit":[17],"such":[19,61],"as":[20,35,52,62],"metro":[21],"and":[22,24,84,106,110,113,131,134,144],"subway,":[23],"railroad":[25],"tunnels.":[26],"From":[27],"a":[28],"ventilation":[29,86,120],"viewpoint":[30],"are":[33,50],"defined":[34],"any":[36],"enclosure":[37],"through":[38],"which":[39,74],"vehicles":[40],"travel.":[41],"This":[42],"definition":[43],"includes":[44],"not":[45],"only":[46],"those":[47,55],"facilities":[48],"that":[49,56],"built":[51],"but":[54],"result":[57],"from":[58],"other":[59],"construction":[60,143],"development":[63],"air":[65],"rights":[66],"over":[67],"roads.":[68],"All":[69],"require":[72],"ventilation,":[73],"can":[75],"be":[76,136],"provided":[77],"by":[78],"natural":[79],"means,":[80],"traffic-induced":[81],"piston":[82],"effects":[83],"mechanical":[85],"equipment.":[87],"Ventilation":[88],"is":[89],"required":[90],"limit":[92],"concentration":[94],"obnoxious":[96],"or":[97],"dangerous":[98],"contaminants":[99],"acceptable":[101],"levels":[102],"during":[103,116],"normal":[104,130],"operation":[105],"also":[107],"remove":[109],"control":[111],"some":[112],"hot":[114],"gases":[115],"fire-based":[117],"emergencies.":[118],"system":[121],"selected":[122],"must":[123],"meet":[124],"specified":[126],"criteria":[127],"for":[128],"both":[129,142],"emergency":[132],"operations":[133],"should":[135],"most":[138],"economical":[139],"solution":[140],"considering":[141],"operating":[145],"costs.":[146]},"counts_by_year":[{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":1}],"updated_date":"2026-10-10T09:11:00.788812","created_date":"2016-06-24T00:00:00"}
