{"id":"https://openalex.org/W85569463","doi":null,"title":"A Sensitivity Study of the Swedish Network Performance Assessment Model Investigating the Effects of Changes in Input Data","display_name":"A Sensitivity Study of the Swedish Network Performance Assessment Model Investigating the Effects of Changes in Input Data","alternate_titles":[],"publication_year":2007,"publication_date":"2007-01-01","ids":{"openalex":"https://openalex.org/W85569463","mag":"85569463"},"language":"en","primary_location":{"id":"pmh:oai:DiVA.org:kth-8310","doi":null,"is_oa":true,"landing_page_url":"http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-8310","pdf_url":null,"source":{"id":"https://openalex.org/S4306401559","display_name":"KTH Publication Database DiVA (KTH Royal Institute of Technology)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I86987016","host_organization_name":"KTH Royal Institute of Technology","host_organization_lineage":["https://openalex.org/I86987016"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"info:eu-repo/semantics/conferenceObject"},"parent_works":[],"lineage":["https://openalex.org/W85569463"],"child_works_count":0,"pull_notice_works":[],"type":"conference-paper","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-8310","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5049343733","display_name":"Carl Johan Wallnerstr\u00f6m","type":null,"orcid":"https://orcid.org/0000-0001-6882-3642","observed_orcids":["https://orcid.org/0000-0001-6882-3642"]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I86987016","display_name":"KTH Royal Institute of Technology","ror":"https://ror.org/026vcq606","country_code":"SE","type":"education","lineage":["https://openalex.org/I86987016"]}],"countries":["SE"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Carl Johan Wallnerstr\u00f6m","raw_affiliation_strings":["Royal Inst. of Technology"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Royal Inst. of Technology","institution_ids":["https://openalex.org/I86987016"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5063119651","display_name":"Lina Bertling Tjernberg","type":null,"orcid":"https://orcid.org/0000-0003-4763-9429","observed_orcids":["https://orcid.org/0000-0003-4763-9429"]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I86987016","display_name":"KTH Royal Institute of Technology","ror":"https://ror.org/026vcq606","country_code":"SE","type":"education","lineage":["https://openalex.org/I86987016"]}],"countries":["SE"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Lina Bertling Tjernberg","raw_affiliation_strings":["Royal Inst. of Technology"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Royal Inst. of Technology","institution_ids":["https://openalex.org/I86987016"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I86987016"],"apc_list":null,"apc_paid":null,"fwci":3.2093,"has_fulltext":true,"cited_by_count":7,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.90903688,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":87,"max":93},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"4"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.8417999744415283,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.8417999744415283,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.030400000512599945,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12451","display_name":"Smart Grid and Power Systems","score":0.027499999850988388,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/network-performance-evaluation","display_name":"network performance evaluation","score":0.8320000171661377},{"id":"https://openalex.org/keywords/sensitivity-analysis","display_name":"sensitivity analysis","score":0.9179999828338623},{"id":"https://openalex.org/keywords/input-data-uncertainty","display_name":"input data uncertainty","score":0.753000020980835},{"id":"https://openalex.org/keywords/electrical-distribution-systems","display_name":"electrical distribution systems","score":0.8199999928474426},{"id":"https://openalex.org/keywords/reference-network","display_name":"reference network","score":0.6069999933242798},{"id":"https://openalex.org/keywords/low-voltage-customers","display_name":"low-voltage customers","score":0.7730000019073486}],"concepts":[{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.7389147281646729},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5471743941307068},{"id":"https://openalex.org/C149782125","wikidata":"https://www.wikidata.org/wiki/Q160039","display_name":"Econometrics","level":1,"score":0.37415313720703125},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.18549463152885437},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.1783319115638733},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"pmh:oai:DiVA.org:kth-8310","doi":null,"is_oa":true,"landing_page_url":"http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-8310","pdf_url":null,"source":{"id":"https://openalex.org/S4306401559","display_name":"KTH Publication Database DiVA (KTH Royal Institute of Technology)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I86987016","host_organization_name":"KTH Royal Institute of Technology","host_organization_lineage":["https://openalex.org/I86987016"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"info:eu-repo/semantics/conferenceObject"},{"id":"mag:85569463","doi":null,"is_oa":false,"landing_page_url":"http://www.cired.net/publications/cired2007/pdfs/CIRED2007_0664_paper.pdf","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":{"id":"pmh:oai:DiVA.org:kth-8310","doi":null,"is_oa":true,"landing_page_url":"http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-8310","pdf_url":null,"source":{"id":"https://openalex.org/S4306401559","display_name":"KTH Publication Database DiVA (KTH Royal Institute of Technology)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I86987016","host_organization_name":"KTH Royal Institute of Technology","host_organization_lineage":["https://openalex.org/I86987016"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"info:eu-repo/semantics/conferenceObject"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","score":0.428600013256073,"display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W85569463.pdf","grobid_xml":"https://content.openalex.org/works/W85569463.grobid-xml"},"referenced_works_count":1,"referenced_works":["https://openalex.org/W2054523743"],"related_works":["https://openalex.org/W2181887597","https://openalex.org/W2158789535","https://openalex.org/W7099581444","https://openalex.org/W2142930911","https://openalex.org/W579123022","https://openalex.org/W2054523743","https://openalex.org/W119139313","https://openalex.org/W258916171","https://openalex.org/W2006174201","https://openalex.org/W2547139269"],"abstract_inverted_index":{"This":[0,41],"paper":[1],"present":[2],"results":[3],"from":[4,105],"a":[5,26,31,66,69,90],"sensitivity":[6],"study":[7],"of":[8,18],"the":[9,47,55,76,102,106],"Network":[10],"Performance":[11],"Assessment":[12],"Model":[13],"(NPAM)":[14],"as":[15],"an":[16],"effect":[17],"changes":[19,50],"in":[20,93,98,101],"input":[21,94],"data.":[22],"The":[23,85],"NPAM":[24],"estimates":[25],"cost":[27],"corresponding":[28],"to":[29,81],"operate":[30],"fictive":[32],"reference":[33],"network,":[34],"so":[35],"called":[36],"network":[37],"performance":[38],"assessment":[39],"(NPA).":[40],"value":[42],"is":[43,88],"then":[44],"compared":[45],"with":[46],"revenue.":[48],"Small":[49],"have":[51],"been":[52],"implemented":[53],"at":[54],"customer":[56,68],"data":[57,95,104],"level":[58],"for":[59],"real":[60],"electrical":[61],"distribution":[62],"systems":[63],"e.g.":[64],"moving":[65],"low-voltage":[67],"few":[70],"meters.":[71],"Results":[72],"show":[73],"on":[74],"that":[75,89],"NPA":[77],"could":[78,96],"differ":[79],"up":[80],"7":[82],"million":[83],"Euros.":[84],"main":[86],"conclusion":[87],"small":[91],"divergence":[92],"result":[97],"significant":[99],"differences":[100],"output":[103],"NPAM.":[107]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W85569463","counts_by_year":[{"year":2013,"cited_by_count":1}],"updated_date":"2026-11-25T09:40:18.809321","created_date":"2016-06-24T00:00:00"}
