{"id":"https://openalex.org/W825397943","doi":null,"title":"Comparison of Performance Characteristics with Heat Exchanger Type in $CO_2$ Cycle","display_name":"Comparison of Performance Characteristics with Heat Exchanger Type in $CO_2$ Cycle","publication_year":2010,"publication_date":"2010-01-01","ids":{"openalex":"https://openalex.org/W825397943","mag":"825397943"},"language":"en","primary_location":{"id":"mag:2235495750","doi":null,"is_oa":false,"landing_page_url":"http://www.dbpia.co.kr/Article/NODE01536354","pdf_url":null,"source":{"id":"https://openalex.org/S4306495615","display_name":"\uc124\ube44\uacf5\ud559\ub17c\ubb38\uc9d1","issn_l":"1229-6422","issn":["1229-6422","2465-7611"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["kci-excellent"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"\uc124\ube44\uacf5\ud559\ub17c\ubb38\uc9d1","raw_type":null},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5046601454","display_name":"Kyung-Jin Bae","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"\ubc30\uacbd\uc9c4","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5027068585","display_name":"Honghyun Cho","orcid":"https://orcid.org/0000-0002-0459-6492","observed_orcids":["https://orcid.org/0000-0002-0459-6492"]},"institutions":[{"id":"https://openalex.org/I152238500","display_name":"Chosun University","ror":"https://ror.org/01zt9a375","country_code":"KR","type":"education","lineage":["https://openalex.org/I152238500"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"\uc870\ud64d\ud604","raw_affiliation_strings":["Chosun Univ"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Chosun Univ","institution_ids":["https://openalex.org/I152238500"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.6716,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.74251167,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"22","issue":"10","first_page":"657","last_page":"664"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.8794000148773193,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.8794000148773193,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10998","display_name":"Heat Transfer and Optimization","score":0.10220000147819519,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11774","display_name":"Adsorption and Cooling Systems","score":0.0044999998062849045,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/co2-refrigeration-cycle","display_name":"CO2 refrigeration cycle","score":0.9279999732971191},{"id":"https://openalex.org/keywords/microchannel-heat-exchangers","display_name":"microchannel heat exchangers","score":0.9430000185966492},{"id":"https://openalex.org/keywords/finned-tube-heat-exchanger","display_name":"finned tube heat exchanger","score":0.9980000257492065},{"id":"https://openalex.org/keywords/gas-cooler","display_name":"gas cooler","score":0.9279999732971191},{"id":"https://openalex.org/keywords/evaporator","display_name":"evaporator","score":0.9860000014305115},{"id":"https://openalex.org/keywords/coefficient-of-performance","display_name":"coefficient of performance","score":0.9610000252723694}],"concepts":[{"id":"https://openalex.org/C91311341","wikidata":"https://www.wikidata.org/wiki/Q1764892","display_name":"Evaporator","level":3,"score":0.8184704184532166},{"id":"https://openalex.org/C63662833","wikidata":"https://www.wikidata.org/wiki/Q6839341","display_name":"Microchannel","level":2,"score":0.7950982451438904},{"id":"https://openalex.org/C107706546","wikidata":"https://www.wikidata.org/wiki/Q189124","display_name":"Heat exchanger","level":2,"score":0.7087516784667969},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.5636671781539917},{"id":"https://openalex.org/C205318045","wikidata":"https://www.wikidata.org/wiki/Q1930881","display_name":"Shell and tube heat exchanger","level":3,"score":0.4770885407924652},{"id":"https://openalex.org/C118227150","wikidata":"https://www.wikidata.org/wiki/Q6839192","display_name":"Micro heat exchanger","level":4,"score":0.46801814436912537},{"id":"https://openalex.org/C32375409","wikidata":"https://www.wikidata.org/wiki/Q261231","display_name":"Plate heat exchanger","level":3,"score":0.46227532625198364},{"id":"https://openalex.org/C39420092","wikidata":"https://www.wikidata.org/wiki/Q17075298","display_name":"Plate fin heat exchanger","level":4,"score":0.4564521312713623},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.45563238859176636},{"id":"https://openalex.org/C2777551473","wikidata":"https://www.wikidata.org/wiki/Q2093072","display_name":"Tube (container)","level":2,"score":0.45206722617149353},{"id":"https://openalex.org/C91721477","wikidata":"https://www.wikidata.org/wiki/Q778612","display_name":"Fin","level":2,"score":0.4427301585674286},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.40787869691848755},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.2087113857269287},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.1249474287033081},{"id":"https://openalex.org/C171250308","wikidata":"https://www.wikidata.org/wiki/Q11468","display_name":"Nanotechnology","level":1,"score":0.07654109597206116}],"mesh":[],"locations_count":2,"locations":[{"id":"mag:2235495750","doi":null,"is_oa":false,"landing_page_url":"http://www.dbpia.co.kr/Article/NODE01536354","pdf_url":null,"source":{"id":"https://openalex.org/S4306495615","display_name":"\uc124\ube44\uacf5\ud559\ub17c\ubb38\uc9d1","issn_l":"1229-6422","issn":["1229-6422","2465-7611"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["kci-excellent"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"\uc124\ube44\uacf5\ud559\ub17c\ubb38\uc9d1","raw_type":null},{"id":"mag:825397943","doi":null,"is_oa":false,"landing_page_url":"http://www.koreascience.or.kr/article/ArticleFullRecord.jsp?cn=SBGHC5_2010_v22n10_657","pdf_url":null,"source":{"id":"https://openalex.org/S4306495615","display_name":"\uc124\ube44\uacf5\ud559\ub17c\ubb38\uc9d1","issn_l":"1229-6422","issn":["1229-6422","2465-7611"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["kci-excellent"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Korean Journal of Air-Conditioning and Refrigeration Engineering","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.9786999821662903,"id":"https://metadata.un.org/sdg/13","display_name":"Climate action"},{"score":0.875,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W779186504","https://openalex.org/W1214580979","https://openalex.org/W2004914838","https://openalex.org/W2012753444","https://openalex.org/W2025564238","https://openalex.org/W2061286638","https://openalex.org/W2070057792","https://openalex.org/W2099646663","https://openalex.org/W2527333829","https://openalex.org/W3093743845"],"related_works":["https://openalex.org/W2235495750","https://openalex.org/W2263978029","https://openalex.org/W2002991590","https://openalex.org/W2099793147","https://openalex.org/W1552167843","https://openalex.org/W2382593098","https://openalex.org/W2006130938","https://openalex.org/W2756327471","https://openalex.org/W1581648001","https://openalex.org/W4297821582"],"abstract_inverted_index":{"ABSTRACT:The":[0],"theoretical":[1],"analysis":[2],"of":[3,23,40,52,58,67,83,98],"performance":[4,22,39],"characteristics":[5],"in":[6],"a":[7,36,108],"CO":[8,100],"2":[9,101,112,142,148],"cycle":[10],"with":[11,32,90],"the":[12,24,38,41,50,59,65,84,91,99],"heat":[13,28,110,116,122],"exchanger":[14,29],"type":[15,86],"was":[16],"carried":[17],"out.":[18],"The":[19,94],"size":[20],"and":[21,26,44,62,70,77,88,96],"fin-tube":[25,42,85],"microchannel":[27,60,68,109],"were":[30,46],"compared":[31,55,80],"operating":[33,53],"conditions.":[34],"As":[35],"result,":[37],"gascooler":[43,61,69,87],"evaporator":[45,71,89],"more":[47],"sensitive":[48],"to":[49,56,81],"variation":[51],"condition":[54],"that":[57],"evaporator.":[63],"Beside,":[64],"sizes":[66],"could":[72],"be":[73,104],"decreased":[74],"by":[75,106],"73%":[76],"76%,":[78],"respectively,":[79],"those":[82],"similar":[92],"capacity.":[93],"COP":[95],"reliability":[97],"system":[102],"can":[103],"increased":[105],"using":[107],"exchanger.Keywords:CO":[111],"cycle(\uc774\uc0b0\ud654\ud0c4\uc18c":[113],"\uc0ac\uc774\ud074),":[114],"Fin-tube":[115],"exchanger(\ud540-\uad00":[117],"\uc5f4\uad50\ud658\uae30),":[118],"Microchannel":[119],"louver":[120],"fin":[121],"exchanger(\ub9c8\uc774\ud06c\ub85c\ucc44\ub110":[123],"\ub8e8\ubc84\ud540":[124],"\uc5f4\uad50\ud658\uae30)":[125],"\u2020Corresponding":[126],"author":[127],"Tel.:":[128],"+82-62-230-7050;":[129],"fax:":[130],"+82-62-230-7055":[131],"E-mail":[132],"address:":[133],"hhcho@chosun.ac.kr":[134],"\uae30":[135],"\ud638":[136],"\uc124":[137],"\uba85":[138],"A":[139],"\uff1a\uba74\uc801":[140],"[m":[141,147],"]A":[143],"t":[144],"\uff1a\uc624\ub9ac\ud53c\uc2a4\ubaa9":[145],"\uba74\uc801":[146],"]D":[149],"\uff1a\uc9c1\uacbd":[150],"[m]D":[151]},"counts_by_year":[],"updated_date":"2026-11-04T10:54:05.112534","created_date":"2016-06-24T00:00:00"}
