{"id":"https://openalex.org/W77041545","doi":null,"title":"Psychrometric Bin Analysis for Alternative Cooling Strategies in Data Centers","display_name":"Psychrometric Bin Analysis for Alternative Cooling Strategies in Data Centers","publication_year":2011,"publication_date":"2011-01-01","ids":{"openalex":"https://openalex.org/W77041545","mag":"77041545"},"language":"en","primary_location":{"id":"mag:77041545","doi":null,"is_oa":false,"landing_page_url":"http://apps1.eere.energy.gov/buildings/publications/pdfs/rsf/psychrometric_bin_analysis_alternative_cooling_strategies_data_centers.pdf","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5015054862","display_name":"Ian Metzger","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Ian Metzger","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5011300065","display_name":"Otto VanGeet","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Otto VanGeet","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5008799100","display_name":"C. Rockenbaugh","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"C. Rockenbaugh","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5113779792","display_name":"Jesse Dean","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Jesse Dean","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5089535613","display_name":"Charles W. Kurnik","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Charles W. Kurnik","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.5866,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.85826192,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":93},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9502000212669373,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9502000212669373,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.024000000208616257,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14098","display_name":"Energy Efficiency in Computing","score":0.00930000003427267,"subfield":{"id":"https://openalex.org/subfields/1708","display_name":"Hardware and Architecture"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/data-center-cooling","display_name":"data center cooling","score":0.9950000047683716},{"id":"https://openalex.org/keywords/evaporative-cooling","display_name":"evaporative cooling","score":0.9769999980926514},{"id":"https://openalex.org/keywords/cooling-energy-savings","display_name":"cooling energy savings","score":0.9210000038146973},{"id":"https://openalex.org/keywords/ashrae-climate-zones","display_name":"ASHRAE climate zones","score":0.9570000171661377},{"id":"https://openalex.org/keywords/control-strategy","display_name":"control strategy","score":0.625},{"id":"https://openalex.org/keywords/data-center-energy-efficiency","display_name":"data center energy efficiency","score":0.699999988079071}],"concepts":[{"id":"https://openalex.org/C206145494","wikidata":"https://www.wikidata.org/wiki/Q4654236","display_name":"ASHRAE 90.1","level":2,"score":0.9654983878135681},{"id":"https://openalex.org/C51983180","wikidata":"https://www.wikidata.org/wiki/Q899784","display_name":"Psychrometrics","level":3,"score":0.8903849124908447},{"id":"https://openalex.org/C41004858","wikidata":"https://www.wikidata.org/wiki/Q1389702","display_name":"Economizer","level":3,"score":0.770490288734436},{"id":"https://openalex.org/C4638862","wikidata":"https://www.wikidata.org/wiki/Q1501558","display_name":"Chiller","level":2,"score":0.6968175172805786},{"id":"https://openalex.org/C156273044","wikidata":"https://www.wikidata.org/wiki/Q4913766","display_name":"Bin","level":2,"score":0.6654918789863586},{"id":"https://openalex.org/C173991790","wikidata":"https://www.wikidata.org/wiki/Q1896787","display_name":"Evaporative cooler","level":2,"score":0.6298683881759644},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.5456006526947021},{"id":"https://openalex.org/C2781099182","wikidata":"https://www.wikidata.org/wiki/Q24963825","display_name":"Cooling load","level":3,"score":0.5210070610046387},{"id":"https://openalex.org/C49996111","wikidata":"https://www.wikidata.org/wiki/Q2277783","display_name":"Free cooling","level":3,"score":0.5176437497138977},{"id":"https://openalex.org/C2778547687","wikidata":"https://www.wikidata.org/wiki/Q193886","display_name":"Cooling tower","level":3,"score":0.45972201228141785},{"id":"https://openalex.org/C7694927","wikidata":"https://www.wikidata.org/wiki/Q7667810","display_name":"Water cooling","level":2,"score":0.4065925180912018},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.3948700428009033},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3175874650478363},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.23415908217430115},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.22876974940299988},{"id":"https://openalex.org/C205649164","wikidata":"https://www.wikidata.org/wiki/Q1071","display_name":"Geography","level":0,"score":0.113640695810318},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C107706546","wikidata":"https://www.wikidata.org/wiki/Q189124","display_name":"Heat exchanger","level":2,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:77041545","doi":null,"is_oa":false,"landing_page_url":"http://apps1.eere.energy.gov/buildings/publications/pdfs/rsf/psychrometric_bin_analysis_alternative_cooling_strategies_data_centers.pdf","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.685699999332428,"id":"https://metadata.un.org/sdg/13","display_name":"Climate action"},{"score":0.571399986743927,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":2,"referenced_works":["https://openalex.org/W1564695234","https://openalex.org/W2165701737"],"related_works":["https://openalex.org/W2409952290","https://openalex.org/W2067653988","https://openalex.org/W2082902869","https://openalex.org/W2237263160","https://openalex.org/W1942537973","https://openalex.org/W2803823791","https://openalex.org/W2146968125","https://openalex.org/W3149410624","https://openalex.org/W2743016843","https://openalex.org/W4391099658"],"abstract_inverted_index":{"Data":[0],"centers":[1,21,139],"are":[2,132,144],"significant":[3],"energy":[4,33,86,98],"users":[5],"and":[6,47,62,117],"require":[7],"continuous":[8],"cooling":[9,54,67,85,97,142],"to":[10,71],"maintain":[11],"high":[12],"levels":[13],"of":[14,19,31,35,59,96,136],"computing":[15],"performance.":[16],"The":[17,107],"majority":[18],"data":[20,36,46,83,138],"have":[22,68],"direct-expansion":[23],"cooling,":[24],"which":[25],"typically":[26],"accounts":[27],"for":[28,102,113],"approximately":[29,92],"50%":[30],"the":[32,79,89,114],"usage":[34],"centers.":[37],"However,":[38],"using":[39,56,140],"typical":[40],"meteorological":[41],"year":[42],"3":[43],"(TMY3)":[44],"weather":[45],"a":[48,57,125],"simple":[49],"psychrometric":[50,108],"bin":[51,109],"analysis,":[52],"alternative":[53,141],"strategies":[55,131,143],"combination":[58],"economizer,":[60],"evaporative,":[61],"supplemental":[63],"direct":[64],"expansion":[65],"(DX)":[66],"been":[69],"shown":[70],"be":[72],"applicable":[73],"in":[74,78],"all":[75],"climate":[76,105],"zones":[77,121],"United":[80],"States.":[81],"Average":[82],"center":[84],"savings":[87,99],"across":[88],"U.S.":[90],"was":[91],"80%.":[93],"An":[94],"analysis":[95,110],"is":[100,111],"presented":[101],"various":[103],"ASHRAE":[104,115],"zones.":[106],"conducted":[112],"recommended":[116],"allowable":[118,127],"operating":[119,128],"environment":[120],"as":[122,124],"well":[123],"modified":[126],"environment.":[129],"Control":[130],"discussed.":[133],"Finally,":[134],"examples":[135],"energy-efficient":[137],"presented.":[145]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":1}],"updated_date":"2025-11-06T04:12:42.849631","created_date":"2016-06-24T00:00:00"}
