{"id":"https://openalex.org/W75100994","doi":null,"title":"Airtightness of Dwellings in Ireland: Design, Workmanship and Control","display_name":"Airtightness of Dwellings in Ireland: Design, Workmanship and Control","alternate_titles":[],"publication_year":2011,"publication_date":"2011-09-01","ids":{"openalex":"https://openalex.org/W75100994","mag":"75100994"},"language":"en","primary_location":{"id":"pmh:oai:repository.wit.ie:2680","doi":null,"is_oa":true,"landing_page_url":"http://repository.wit.ie/2680/1/Airtightness%20of%20Dwellings%20in%20Ireland%20Design%20Workmanship%20and%20Control%20Camera%20Version.pdf","pdf_url":"http://repository.wit.ie/2680/1/Airtightness%20of%20Dwellings%20in%20Ireland%20Design%20Workmanship%20and%20Control%20Camera%20Version.pdf","source":{"id":"https://openalex.org/S4377196138","display_name":"SETU Waterford Libraries - Open Access Repository","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"Conference or Workshop Item"},"parent_works":[],"lineage":["https://openalex.org/W75100994"],"child_works_count":0,"type":"conference-paper","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"http://repository.wit.ie/2680/1/Airtightness%20of%20Dwellings%20in%20Ireland%20Design%20Workmanship%20and%20Control%20Camera%20Version.pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5051135986","display_name":"Derek Sinnott","orcid":"https://orcid.org/0000-0003-3969-8699","observed_orcids":["https://orcid.org/0000-0003-3969-8699"]},"institutions":[{"id":"https://openalex.org/I7478328","display_name":"Waterford Institute of Technology","ror":"https://ror.org/03ypxwh20","country_code":"IE","type":"nonprofit","lineage":["https://openalex.org/I4387156359","https://openalex.org/I7478328"]}],"countries":["IE"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Sinnott, Derek","raw_affiliation_strings":["Department of Construction and Civil Engineering , Waterford Institute of Technology , Waterford , Ireland","[Waterford Institute of Technology]"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Construction and Civil Engineering , Waterford Institute of Technology , Waterford , Ireland","institution_ids":["https://openalex.org/I7478328"]},{"raw_affiliation_string":"[Waterford Institute of Technology]","institution_ids":["https://openalex.org/I7478328"]}]},{"author_position":"last","author":{"id":null,"display_name":"Dyer, Mark","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I205274468","display_name":"Trinity College Dublin","ror":"https://ror.org/02tyrky19","country_code":"IE","type":"education","lineage":["https://openalex.org/I205274468"]}],"countries":["IE"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Dyer, Mark","raw_affiliation_strings":["TrinityHaus , Trinity College Dublin , Dublin 2 , Ireland","Trinity College Dublin"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"TrinityHaus , Trinity College Dublin , Dublin 2 , Ireland","institution_ids":["https://openalex.org/I205274468"]},{"raw_affiliation_string":"Trinity College Dublin","institution_ids":["https://openalex.org/I205274468"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.8526,"has_fulltext":true,"cited_by_count":14,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.66000908,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":97},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T13263","display_name":"Building energy efficiency and sustainability","score":0.9404000043869019,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T13263","display_name":"Building energy efficiency and sustainability","score":0.9404000043869019,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.05609999969601631,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12105","display_name":"Hygrothermal properties of building materials","score":0.00039999998989515007,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/air-tightness","display_name":"air tightness","score":0.9350000023841858},{"id":"https://openalex.org/keywords/dwelling","display_name":"dwelling","score":0.8460000157356262},{"id":"https://openalex.org/keywords/air-tightness-testing","display_name":"airtightness testing","score":0.9319999814033508},{"id":"https://openalex.org/keywords/household-energy-consumption","display_name":"household energy consumption","score":0.7839999794960022},{"id":"https://openalex.org/keywords/space-heating","display_name":"space heating","score":0.9700000286102295},{"id":"https://openalex.org/keywords/building-design","display_name":"building design","score":0.5640000104904175},{"id":"https://openalex.org/keywords/construction-workmanship","display_name":"construction workmanship","score":0.9589999914169312},{"id":"https://openalex.org/keywords/building-control","display_name":"building control","score":0.4009999930858612},{"id":"https://openalex.org/keywords/indoor-environmental-quality","display_name":"indoor environmental quality","score":0.906000018119812}],"concepts":[{"id":"https://openalex.org/C2776232490","wikidata":"https://www.wikidata.org/wiki/Q8035029","display_name":"Workmanship","level":2,"score":0.957744836807251},{"id":"https://openalex.org/C170154142","wikidata":"https://www.wikidata.org/wiki/Q150737","display_name":"Architectural engineering","level":1,"score":0.5690950751304626},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.5353245139122009},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.48631343245506287},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.4265861213207245},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.41135331988334656},{"id":"https://openalex.org/C133913538","wikidata":"https://www.wikidata.org/wiki/Q774514","display_name":"Thermal comfort","level":2,"score":0.4109021723270416},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.39876285195350647},{"id":"https://openalex.org/C147176958","wikidata":"https://www.wikidata.org/wiki/Q77590","display_name":"Civil engineering","level":1,"score":0.3910284638404846},{"id":"https://openalex.org/C205649164","wikidata":"https://www.wikidata.org/wiki/Q1071","display_name":"Geography","level":0,"score":0.2762908637523651},{"id":"https://openalex.org/C21547014","wikidata":"https://www.wikidata.org/wiki/Q1423657","display_name":"Operations management","level":1,"score":0.23630449175834656},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.1847492754459381},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.13638955354690552},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"pmh:oai:repository.wit.ie:2680","doi":null,"is_oa":true,"landing_page_url":"http://repository.wit.ie/2680/1/Airtightness%20of%20Dwellings%20in%20Ireland%20Design%20Workmanship%20and%20Control%20Camera%20Version.pdf","pdf_url":"http://repository.wit.ie/2680/1/Airtightness%20of%20Dwellings%20in%20Ireland%20Design%20Workmanship%20and%20Control%20Camera%20Version.pdf","source":{"id":"https://openalex.org/S4377196138","display_name":"SETU Waterford Libraries - Open Access Repository","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"Conference or Workshop Item"}],"best_oa_location":{"id":"pmh:oai:repository.wit.ie:2680","doi":null,"is_oa":true,"landing_page_url":"http://repository.wit.ie/2680/1/Airtightness%20of%20Dwellings%20in%20Ireland%20Design%20Workmanship%20and%20Control%20Camera%20Version.pdf","pdf_url":"http://repository.wit.ie/2680/1/Airtightness%20of%20Dwellings%20in%20Ireland%20Design%20Workmanship%20and%20Control%20Camera%20Version.pdf","source":{"id":"https://openalex.org/S4377196138","display_name":"SETU Waterford Libraries - Open Access Repository","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"Conference or Workshop Item"},"sustainable_development_goals":[{"score":0.5142999887466431,"display_name":"Sustainable cities and communities","id":"https://metadata.un.org/sdg/11"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W75100994.pdf","grobid_xml":"https://content.openalex.org/works/W75100994.grobid-xml"},"referenced_works_count":6,"referenced_works":["https://openalex.org/W1965990468","https://openalex.org/W2013085419","https://openalex.org/W2050569461","https://openalex.org/W2078837689","https://openalex.org/W2297693228","https://openalex.org/W2773808691"],"related_works":["https://openalex.org/W2058005988","https://openalex.org/W7064307612","https://openalex.org/W2752408392","https://openalex.org/W7135260171","https://openalex.org/W1986285002","https://openalex.org/W2947661018","https://openalex.org/W2958839750","https://openalex.org/W2625291731","https://openalex.org/W6929142937","https://openalex.org/W2292594380"],"abstract_inverted_index":{"The":[0,55,65,93,106],"residential":[1],"sector":[2],"accounts":[3],"for":[4,15,63],"25%":[5],"of":[6,11,44,53,60,80,88],"Ireland'\\ns":[7],"total":[8],"energy":[9,33],"consumption,":[10],"which\\n60%":[12],"is":[13,25,83,119],"used":[14],"space":[16],"heating.":[17],"As":[18],"thermal":[19],"insulatio\\nn":[20],"standards":[21],"increase,":[22],"building":[23],"air\\ntightness":[24],"playing":[26],"an":[27],"increasing":[28],"role":[29],"in":[30,91],"both":[31],"bui\\nlding":[32],"performance":[34],"and":[35,72,114],"indoor\\nenvironmental":[36],"quality.":[37],"This":[38],"paper":[39,56,107],"reports":[40],"on":[41,49],"the":[42,58,74,78],"re\\nsults":[43],"air":[45],"tightness":[46],"testing":[47],"carried\\nout":[48],"a":[50,96],"small":[51,84],"number":[52,79],"dwellings.":[54,123],"highl\\nights":[57],"paucity":[59],"dwelling\\nairtightness":[61],"data":[62],"Ireland.":[64,92],"results":[66],"are":[67,86,100],"comp\\nared":[68],"to":[69,112],"past":[70],"studies":[71],"compliance\\nwith":[73],"existing":[75],"standards.":[76],"While":[77],"ho\\nuses":[81],"tested":[82],"they":[85],"broadly\\nrepresentative":[87],"urban":[89],"dwellings":[90],"s\\ntudy":[94],"indicates":[95],"misconception":[97],"that\\nnewer":[98],"buildings":[99],"more":[101],"airtight":[102],"than":[103],"older":[104],"buildi\\nngs.":[105],"concludes":[108],"that":[109],"good\\ndesign,":[110],"attention":[111],"detail":[113],"rigorous":[115],"controls":[116],"t\\nhroughout":[117],"construction":[118],"vital":[120],"to\\ndelivering":[121],"air-tight":[122]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W75100994","counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":4},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":4},{"year":2017,"cited_by_count":1},{"year":2015,"cited_by_count":2},{"year":2014,"cited_by_count":1}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2025-10-10T00:00:00"}