{"id":"https://openalex.org/W7238790983","doi":"https://doi.org/10.17148/ijireeice.2026.141116","title":"Power Quality Analysis of a Ceramic Manufacturing Unit Using Field Measurements","display_name":"Power Quality Analysis of a Ceramic Manufacturing Unit Using Field Measurements","alternate_titles":[],"publication_year":2026,"publication_date":"2026-11-23","ids":{"openalex":"https://openalex.org/W7238790983","doi":"https://doi.org/10.17148/ijireeice.2026.141116"},"language":"en","primary_location":{"id":"doi:10.17148/ijireeice.2026.141116","doi":"https://doi.org/10.17148/ijireeice.2026.141116","is_oa":true,"landing_page_url":"https://doi.org/10.17148/ijireeice.2026.141116","pdf_url":"https://doi.org/10.17148/ijireeice.2026.141116","source":{"id":"https://openalex.org/S4210183758","display_name":"IJIREEICE","issn_l":"2321-2004","issn":["2321-2004","2321-5526"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IJIREEICE","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W7238790983"],"child_works_count":0,"pull_notice_works":[],"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"diamond","oa_url":"https://doi.org/10.17148/ijireeice.2026.141116","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5116312181","display_name":"Ankit B. Lehru","type":null,"orcid":"https://orcid.org/0009-0009-9215-1693","observed_orcids":["https://orcid.org/0009-0009-9215-1693"]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I4210105737","display_name":"Atmiya University","ror":"https://ror.org/01cj5hx77","country_code":"IN","type":"education","lineage":["https://openalex.org/I4210105737"]}],"countries":["IN"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Ankit B. Lehru","raw_affiliation_strings":["Department of Electrical Engineering , Atmiya University , Rajkot , India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering , Atmiya University , Rajkot , India","institution_ids":["https://openalex.org/I4210105737"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5015831315","display_name":"Dharmesh J. Pandya","type":null,"orcid":"https://orcid.org/0000-0002-7146-8247","observed_orcids":["https://orcid.org/0000-0002-7146-8247"]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I4210105737","display_name":"Atmiya University","ror":"https://ror.org/01cj5hx77","country_code":"IN","type":"education","lineage":["https://openalex.org/I4210105737"]}],"countries":["IN"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Dharmesh J. Pandya","raw_affiliation_strings":["Department of Electrical Engineering , Atmiya University , Rajkot , India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering , Atmiya University , Rajkot , India","institution_ids":["https://openalex.org/I4210105737"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I4210105737"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":true,"cited_by_count":0,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"14","issue":"11","first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[],"concepts":[{"id":"https://openalex.org/C64424096","wikidata":"https://www.wikidata.org/wiki/Q750454","display_name":"Power factor","level":3,"score":0.8191999793052673},{"id":"https://openalex.org/C42156128","wikidata":"https://www.wikidata.org/wiki/Q162641","display_name":"Total harmonic distortion","level":3,"score":0.767300009727478},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.7261999845504761},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5620999932289124},{"id":"https://openalex.org/C46529443","wikidata":"https://www.wikidata.org/wiki/Q7940750","display_name":"Voltage optimisation","level":4,"score":0.5594000220298767},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5113000273704529},{"id":"https://openalex.org/C151799858","wikidata":"https://www.wikidata.org/wiki/Q587008","display_name":"Switched-mode power supply","level":3,"score":0.5110999941825867},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.4431000053882599},{"id":"https://openalex.org/C59407501","wikidata":"https://www.wikidata.org/wiki/Q550341","display_name":"Volt-ampere reactive","level":5,"score":0.43149998784065247},{"id":"https://openalex.org/C197424946","wikidata":"https://www.wikidata.org/wiki/Q1165717","display_name":"Waveform","level":3,"score":0.4228000044822693},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.42149999737739563},{"id":"https://openalex.org/C50825304","wikidata":"https://www.wikidata.org/wiki/Q260295","display_name":"Single-phase electric power","level":4,"score":0.37790000438690186},{"id":"https://openalex.org/C126780896","wikidata":"https://www.wikidata.org/wiki/Q899871","display_name":"Distortion (music)","level":4,"score":0.36340001225471497},{"id":"https://openalex.org/C173871940","wikidata":"https://www.wikidata.org/wiki/Q471846","display_name":"Three-phase","level":3,"score":0.36000001430511475},{"id":"https://openalex.org/C127934551","wikidata":"https://www.wikidata.org/wiki/Q1148098","display_name":"Harmonic","level":2,"score":0.35910001397132874},{"id":"https://openalex.org/C23340480","wikidata":"https://www.wikidata.org/wiki/Q358932","display_name":"Inrush current","level":4,"score":0.3589000105857849},{"id":"https://openalex.org/C188414643","wikidata":"https://www.wikidata.org/wiki/Q3001183","display_name":"Harmonics","level":3,"score":0.33869999647140503},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3384000062942505},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.32989999651908875},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.328000009059906},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3156000077724457},{"id":"https://openalex.org/C148367217","wikidata":"https://www.wikidata.org/wiki/Q550341","display_name":"Volt-ampere","level":5,"score":0.3086000084877014},{"id":"https://openalex.org/C131770355","wikidata":"https://www.wikidata.org/wiki/Q876215","display_name":"Harmonic analysis","level":2,"score":0.30000001192092896},{"id":"https://openalex.org/C40293303","wikidata":"https://www.wikidata.org/wiki/Q27137","display_name":"Electric power","level":3,"score":0.2854999899864197},{"id":"https://openalex.org/C29586797","wikidata":"https://www.wikidata.org/wiki/Q5163663","display_name":"Constant power circuit","level":4,"score":0.27720001339912415},{"id":"https://openalex.org/C2778160759","wikidata":"https://www.wikidata.org/wiki/Q1780079","display_name":"Electric power quality","level":4,"score":0.275299996137619},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.26989999413490295},{"id":"https://openalex.org/C2779876028","wikidata":"https://www.wikidata.org/wiki/Q124164","display_name":"Alternating current","level":3,"score":0.25760000944137573},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.2554999887943268}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.17148/ijireeice.2026.141116","doi":"https://doi.org/10.17148/ijireeice.2026.141116","is_oa":true,"landing_page_url":"https://doi.org/10.17148/ijireeice.2026.141116","pdf_url":"https://doi.org/10.17148/ijireeice.2026.141116","source":{"id":"https://openalex.org/S4210183758","display_name":"IJIREEICE","issn_l":"2321-2004","issn":["2321-2004","2321-5526"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IJIREEICE","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.17148/ijireeice.2026.141116","doi":"https://doi.org/10.17148/ijireeice.2026.141116","is_oa":true,"landing_page_url":"https://doi.org/10.17148/ijireeice.2026.141116","pdf_url":"https://doi.org/10.17148/ijireeice.2026.141116","source":{"id":"https://openalex.org/S4210183758","display_name":"IJIREEICE","issn_l":"2321-2004","issn":["2321-2004","2321-5526"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IJIREEICE","raw_type":"journal-article"},"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W7238790983.pdf","grobid_xml":"https://content.openalex.org/works/W7238790983.grobid-xml"},"referenced_works_count":8,"referenced_works":["https://openalex.org/W2767319689","https://openalex.org/W3189712079","https://openalex.org/W4402673728","https://openalex.org/W4403348628","https://openalex.org/W4408489562","https://openalex.org/W4408611674","https://openalex.org/W7151709385","https://openalex.org/W7171942653"],"related_works":[],"abstract_inverted_index":{"Power":[0],"quality":[1,45,104,241,271],"plays":[2],"a":[3,48,71,86,92,101,221,260,278],"significant":[4,239],"role":[5],"in":[6,55,200,296],"the":[7,43,82,153,168,172,211,225,237,246,257],"efficient":[8],"operation":[9],"and":[10,27,37,66,78,91,110,115,122,129,141,150,180,189,195,230,291],"energy":[11,275,294],"management":[12,295],"of":[13,47,75,177,183,205,259],"industrial":[14],"facilities.Electrical":[15],"issues":[16],"such":[17],"as":[18,236],"voltage":[19,109,114,145],"waveform":[20,155],"distortion,":[21,159],"harmonic":[22,118,228],"currents,":[23],"reactive":[24,123,184,231],"power":[25,29,44,103,131,179,188,191,203,232,240,252,270,286],"consumption,":[26],"low":[28],"factor":[30,204,253],"can":[31],"contribute":[32],"to":[33,166,284],"higher":[34],"system":[35,112],"loading":[36],"increased":[38],"electrical":[39,73],"losses.This":[40],"study":[41,243],"investigates":[42],"performance":[46],"continuously":[49],"operating":[50,170],"ceramic":[51,297],"manufacturing":[52],"unit":[53],"located":[54],"Thangadh,":[56],"Surendranagar,":[57],"Gujarat,":[58],"India,":[59],"using":[60,100],"actual":[61],"field":[62],"measurements.The":[63],"selected":[64],"small":[65,208],"medium-sized":[67],"enterprise":[68],"(SME)":[69],"has":[70],"sanctioned":[72],"load":[74],"100":[76],"kW":[77,94,176],"is":[79],"supplied":[80],"through":[81],"utility":[83],"grid,":[84],"with":[85,144,160,273],"diesel":[87],"generator":[88],"for":[89,281],"backup":[90],"50":[93],"photovoltaic":[95],"system.Electrical":[96],"measurements":[97,272],"were":[98,136,192,234],"recorded":[99,133],"three-phase":[102],"analyzer.The":[105],"assessment":[106],"included":[107],"RMS":[108],"current,":[111],"frequency,":[113],"current":[116,154,161,217],"total":[117],"distortion":[119,127,187,229],"(THD),":[120],"active":[121,178],"power,":[124,126,128],"apparent":[125,190],"overall":[130,202],"factor.The":[132],"phase":[134,213],"voltages":[135],"252.4":[137],"V,":[138,140,143],"250.1":[139],"250.0":[142],"THD":[146,162],"values":[147],"between":[148],"5.8%":[149],"6.0%.In":[151],"comparison,":[152],"showed":[156],"considerably":[157],"greater":[158],"ranging":[163],"from":[164],"15.4%":[165],"17.5%.Under":[167],"measured":[169],"condition,":[171],"facility":[173],"consumed":[174],"36.78":[175],"19.81":[181],"kVAr":[182,194,250],"power.The":[185],"corresponding":[186],"7.901":[193],"42.52":[196],"kVA,":[197],"respectively,":[198],"resulting":[199],"an":[201],"0.865.The":[206],"relatively":[207],"variation":[209],"among":[210],"three":[212],"currents":[214],"suggests":[215],"that":[216,267],"imbalance":[218],"was":[219],"not":[220],"major":[222],"concern":[223],"during":[224],"measurement":[226],"period.Instead,":[227],"demand":[233],"identified":[235],"more":[238],"issues.The":[242],"further":[244],"examines":[245],"facility's":[247],"existing":[248],"60":[249],"automatic":[251],"correction":[254],"system,":[255],"including":[256],"effect":[258],"reported":[261],"derated":[262],"capacitor":[263],"step.The":[264],"findings":[265],"indicate":[266],"combining":[268],"on-site":[269],"conventional":[274],"auditing":[276],"provides":[277],"useful":[279],"approach":[280],"identifying":[282],"opportunities":[283],"improve":[285],"factor,":[287],"reduce":[288],"harmonic-related":[289],"problems,":[290],"strengthen":[292],"demand-side":[293],"SMEs.":[298]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W7238790983","counts_by_year":[],"updated_date":"2026-11-24T14:10:38.155754","created_date":"2026-11-24T00:00:00"}
