{"id":"https://openalex.org/W7225742337","doi":"https://doi.org/10.5281/zenodo.24108996","title":"A Disaster Mesh Communications Budget for a Town Without Grid or Towers: Coverage, Traffic, Power and Price for the First Week","display_name":"A Disaster Mesh Communications Budget for a Town Without Grid or Towers: Coverage, Traffic, Power and Price for the First Week","publication_year":2026,"publication_date":"2026-11-10","ids":{"openalex":"https://openalex.org/W7225742337","doi":"https://doi.org/10.5281/zenodo.24108996"},"language":"en","primary_location":{"id":"doi:10.5281/zenodo.24108996","doi":"https://doi.org/10.5281/zenodo.24108996","is_oa":true,"landing_page_url":"https://doi.org/10.5281/zenodo.24108996","pdf_url":null,"source":{"id":"https://openalex.org/S4306400562","display_name":"Zenodo (CERN European Organization for Nuclear Research)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I67311998","host_organization_name":"European Organization for Nuclear Research","host_organization_lineage":["https://openalex.org/I67311998"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"JournalArticle"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["datacite"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://doi.org/10.5281/zenodo.24108996","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5159396451","display_name":"William Alexander Aldred","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Aldred, William Alexander","raw_affiliation_strings":[],"raw_orcid":"https://orcid.org/0009-0000-1215-577X","affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5159396451"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12079","display_name":"IoT Networks and Protocols","score":0.8910999894142151,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12079","display_name":"IoT Networks and Protocols","score":0.8910999894142151,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10246","display_name":"Mobile Ad Hoc Networks","score":0.06449999660253525,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10080","display_name":"Energy Efficient Wireless Sensor Networks","score":0.012400000356137753,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[],"concepts":[{"id":"https://openalex.org/C2778156585","wikidata":"https://www.wikidata.org/wiki/Q174053","display_name":"Relay","level":3,"score":0.6509000062942505},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5687999725341797},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.5342000126838684},{"id":"https://openalex.org/C161840515","wikidata":"https://www.wikidata.org/wiki/Q186131","display_name":"Terrain","level":2,"score":0.5192999839782715},{"id":"https://openalex.org/C2776398200","wikidata":"https://www.wikidata.org/wiki/Q508880","display_name":"Aloha","level":4,"score":0.49790000915527344},{"id":"https://openalex.org/C2983254600","wikidata":"https://www.wikidata.org/wiki/Q1096907","display_name":"Power grid","level":3,"score":0.45669999718666077},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.44190001487731934},{"id":"https://openalex.org/C103760667","wikidata":"https://www.wikidata.org/wiki/Q798444","display_name":"Backhaul (telecommunications)","level":3,"score":0.4278999865055084},{"id":"https://openalex.org/C509933004","wikidata":"https://www.wikidata.org/wiki/Q194163","display_name":"Broadband","level":2,"score":0.40540000796318054},{"id":"https://openalex.org/C82876162","wikidata":"https://www.wikidata.org/wiki/Q17096504","display_name":"Latency (audio)","level":2,"score":0.3896999955177307},{"id":"https://openalex.org/C204323151","wikidata":"https://www.wikidata.org/wiki/Q905424","display_name":"Range (aeronautics)","level":2,"score":0.38749998807907104},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.383899986743927},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3785000145435333},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3490000069141388},{"id":"https://openalex.org/C2777831296","wikidata":"https://www.wikidata.org/wiki/Q12518","display_name":"Tower","level":2,"score":0.3336000144481659},{"id":"https://openalex.org/C101618186","wikidata":"https://www.wikidata.org/wiki/Q3633928","display_name":"UMTS frequency bands","level":2,"score":0.3312000036239624},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3228999972343445},{"id":"https://openalex.org/C105306849","wikidata":"https://www.wikidata.org/wiki/Q81054","display_name":"Storm","level":2,"score":0.32179999351501465},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.3167000114917755},{"id":"https://openalex.org/C2778258436","wikidata":"https://www.wikidata.org/wiki/Q30672262","display_name":"Outage probability","level":4,"score":0.3118000030517578},{"id":"https://openalex.org/C125599584","wikidata":"https://www.wikidata.org/wiki/Q15057100","display_name":"Broadband networks","level":3,"score":0.3059999942779541},{"id":"https://openalex.org/C2777767291","wikidata":"https://www.wikidata.org/wiki/Q1080291","display_name":"Sizing","level":2,"score":0.3059999942779541},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.30390000343322754},{"id":"https://openalex.org/C62611344","wikidata":"https://www.wikidata.org/wiki/Q1062658","display_name":"Node (physics)","level":2,"score":0.30309998989105225},{"id":"https://openalex.org/C128765274","wikidata":"https://www.wikidata.org/wiki/Q663314","display_name":"Hexagonal crystal system","level":2,"score":0.29019999504089355},{"id":"https://openalex.org/C184773241","wikidata":"https://www.wikidata.org/wiki/Q387400","display_name":"Mains electricity","level":3,"score":0.2870999872684479},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.28679999709129333},{"id":"https://openalex.org/C163164238","wikidata":"https://www.wikidata.org/wiki/Q2737027","display_name":"Failure rate","level":2,"score":0.2786000072956085},{"id":"https://openalex.org/C95491727","wikidata":"https://www.wikidata.org/wiki/Q992968","display_name":"Mobile telephony","level":3,"score":0.275299996137619},{"id":"https://openalex.org/C2984532965","wikidata":"https://www.wikidata.org/wiki/Q380170","display_name":"Power saving","level":3,"score":0.2662999927997589},{"id":"https://openalex.org/C5979214","wikidata":"https://www.wikidata.org/wiki/Q126932","display_name":"Cost of electricity by source","level":4,"score":0.25429999828338623},{"id":"https://openalex.org/C2412688","wikidata":"https://www.wikidata.org/wiki/Q503732","display_name":"Protective relay","level":4,"score":0.251800000667572},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.2517000138759613}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.5281/zenodo.24108996","doi":"https://doi.org/10.5281/zenodo.24108996","is_oa":true,"landing_page_url":"https://doi.org/10.5281/zenodo.24108996","pdf_url":null,"source":{"id":"https://openalex.org/S4306400562","display_name":"Zenodo (CERN European Organization for Nuclear Research)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I67311998","host_organization_name":"European Organization for Nuclear Research","host_organization_lineage":["https://openalex.org/I67311998"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"JournalArticle"},{"id":"doi:10.5281/zenodo.24108997","doi":"https://doi.org/10.5281/zenodo.24108997","is_oa":true,"landing_page_url":"https://doi.org/10.5281/zenodo.24108997","pdf_url":null,"source":{"id":"https://openalex.org/S4306400562","display_name":"Zenodo (CERN European Organization for Nuclear Research)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I67311998","host_organization_name":"European Organization for Nuclear Research","host_organization_lineage":["https://openalex.org/I67311998"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"JournalArticle"}],"best_oa_location":{"id":"doi:10.5281/zenodo.24108996","doi":"https://doi.org/10.5281/zenodo.24108996","is_oa":true,"landing_page_url":"https://doi.org/10.5281/zenodo.24108996","pdf_url":null,"source":{"id":"https://openalex.org/S4306400562","display_name":"Zenodo (CERN European Organization for Nuclear Research)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I67311998","host_organization_name":"European Organization for Nuclear Research","host_organization_lineage":["https://openalex.org/I67311998"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"JournalArticle"},"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"A":[0],"LoRa-class":[1],"mesh":[2],"of":[3,31,128],"solar":[4],"relay":[5,109,149],"nodes":[6],"plus":[7],"household":[8],"handsets":[9],"is":[10,126,135],"designed":[11],"and":[12,24,49,58,75,112,134,146],"priced":[13],"for":[14],"the":[15,131,143,147],"first":[16],"week":[17],"after":[18],"a":[19,28,52,61,79],"disaster":[20],"removes":[21],"grid":[22],"power":[23],"cellular":[25],"towers":[26],"from":[27],"stated":[29,62,80],"town":[30],"10.0":[32],"km":[33,36,97],"by":[34,138],"6.0":[35],"with":[37],"7500":[38],"households.":[39],"Link":[40],"budgets":[41],"over":[42],"three":[43],"terrain":[44,125],"classes,":[45],"hexagonal":[46],"node":[47],"spacing":[48],"count":[50],"under":[51,60],"double-coverage":[53],"requirement,":[54],"ALOHA":[55],"delivery":[56,154],"probability":[57],"latency":[59],"coded-message":[63],"load":[64],"(welfare":[65],"checks,":[66],"clinic":[67],"requests,":[68],"water-point":[69],"status;":[70],"11,796":[71],"messages":[72,157],"per":[73,108,110,114,158],"day),":[74],"battery/solar":[76],"sizing":[77],"through":[78],"seven-day":[81],"storm":[82],"profile":[83],"are":[84,119],"computed":[85],"in":[86],"one":[87],"integrated":[88],"budget.":[89],"The":[90],"design":[91,132],"gives":[92],"8":[93],"relays":[94,141],"at":[95,121,130,142],"4.64":[96],"spacing,":[98],"0.989":[99],"end-to-end":[100],"delivery,":[101],"2.57":[102],"s":[103],"mean":[104],"latency,":[105],"43.2":[106],"Wh":[107],"day,":[111],"$42.91":[113],"covered":[115],"household.":[116],"Failure":[117],"regimes":[118],"printed":[120],"full":[122],"size:":[123],"shadowed":[124],"out":[127],"range":[129],"rate":[133],"served":[136],"only":[137],"24":[139],"m":[140],"slowest":[144],"rate,":[145],"single-channel":[148],"backhaul":[150],"falls":[151],"below":[152],"90%":[153],"above":[155],"29,057":[156],"day.":[159],"SIMULATED,":[160],"NOT":[161],"MEASURED.":[162]},"counts_by_year":[],"updated_date":"2026-11-11T12:16:26.678958","created_date":"2026-11-11T00:00:00"}