{"id":"https://openalex.org/W7225737868","doi":"https://doi.org/10.68263/bjar-ked4bzg6","title":"Evaluating Human-Centred Design Strategies for Enhancing Occupant Comfort and Well-Being in Institutional Buildings in Lagos, Nigeria.","display_name":"Evaluating Human-Centred Design Strategies for Enhancing Occupant Comfort and Well-Being in Institutional Buildings in Lagos, Nigeria.","publication_year":2026,"publication_date":"2026-11-10","ids":{"openalex":"https://openalex.org/W7225737868","doi":"https://doi.org/10.68263/bjar-ked4bzg6"},"language":"en","primary_location":{"id":"doi:10.68263/bjar-ked4bzg6","doi":"https://doi.org/10.68263/bjar-ked4bzg6","is_oa":true,"landing_page_url":"https://doi.org/10.68263/bjar-ked4bzg6","pdf_url":null,"source":{"id":"https://openalex.org/S7407064920","display_name":"British Journal of Advanced Research","issn_l":"3153-709X","issn":["3153-709X"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by-nc-sa","license_id":"https://openalex.org/licenses/cc-by-nc-sa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"British Journal of Advanced Research","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"hybrid","oa_url":"https://doi.org/10.68263/bjar-ked4bzg6","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5160380181","display_name":"Ugboh Moses Chukwudi","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4387154758","display_name":"Anchor University Lagos","ror":"https://ror.org/01zr8ek85","country_code":"NG","type":"education","lineage":["https://openalex.org/I4387154758"]}],"countries":["NG"],"is_corresponding":true,"raw_author_name":"Ugboh Moses Chukwudi","raw_affiliation_strings":["Department of Architecture, Anchor University Lagos, Nigeria"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Architecture, Anchor University Lagos, Nigeria","institution_ids":["https://openalex.org/I4387154758"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5160380181"],"corresponding_institution_ids":["https://openalex.org/I4387154758"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"1","issue":"5","first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12256","display_name":"Facilities and Workplace Management","score":0.9911999702453613,"subfield":{"id":"https://openalex.org/subfields/2216","display_name":"Architecture"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12256","display_name":"Facilities and Workplace Management","score":0.9911999702453613,"subfield":{"id":"https://openalex.org/subfields/2216","display_name":"Architecture"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.00839999970048666,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12950","display_name":"Educational Environments and Student Outcomes","score":0.0,"subfield":{"id":"https://openalex.org/subfields/3304","display_name":"Education"},"field":{"id":"https://openalex.org/fields/33","display_name":"Social Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}}],"keywords":[],"concepts":[{"id":"https://openalex.org/C133913538","wikidata":"https://www.wikidata.org/wiki/Q774514","display_name":"Thermal comfort","level":2,"score":0.6643999814987183},{"id":"https://openalex.org/C2780598303","wikidata":"https://www.wikidata.org/wiki/Q65921492","display_name":"Flexibility (engineering)","level":2,"score":0.6111999750137329},{"id":"https://openalex.org/C2778215892","wikidata":"https://www.wikidata.org/wiki/Q1345987","display_name":"Post-occupancy evaluation","level":2,"score":0.6011000275611877},{"id":"https://openalex.org/C170154142","wikidata":"https://www.wikidata.org/wiki/Q150737","display_name":"Architectural engineering","level":1,"score":0.5162000060081482},{"id":"https://openalex.org/C117009084","wikidata":"https://www.wikidata.org/wiki/Q837060","display_name":"Facility management","level":2,"score":0.5001999735832214},{"id":"https://openalex.org/C65469","wikidata":"https://www.wikidata.org/wiki/Q905504","display_name":"Indoor air quality","level":2,"score":0.48919999599456787},{"id":"https://openalex.org/C190831278","wikidata":"https://www.wikidata.org/wiki/Q323611","display_name":"Building design","level":2,"score":0.46549999713897705},{"id":"https://openalex.org/C2779530757","wikidata":"https://www.wikidata.org/wiki/Q1207505","display_name":"Quality (philosophy)","level":2,"score":0.4596000015735626},{"id":"https://openalex.org/C206018219","wikidata":"https://www.wikidata.org/wiki/Q1427418","display_name":"Natural ventilation","level":3,"score":0.4535999894142151},{"id":"https://openalex.org/C148803439","wikidata":"https://www.wikidata.org/wiki/Q4986688","display_name":"Built environment","level":2,"score":0.40860000252723694},{"id":"https://openalex.org/C39896193","wikidata":"https://www.wikidata.org/wiki/Q380344","display_name":"Descriptive statistics","level":2,"score":0.38600000739097595},{"id":"https://openalex.org/C126314574","wikidata":"https://www.wikidata.org/wiki/Q2364111","display_name":"Air quality index","level":2,"score":0.36559998989105225},{"id":"https://openalex.org/C70798638","wikidata":"https://www.wikidata.org/wiki/Q4575211","display_name":"Environmental quality","level":2,"score":0.3628999888896942},{"id":"https://openalex.org/C2988118254","wikidata":"https://www.wikidata.org/wiki/Q16881889","display_name":"Rating system","level":2,"score":0.3621000051498413},{"id":"https://openalex.org/C144133560","wikidata":"https://www.wikidata.org/wiki/Q4830453","display_name":"Business","level":0,"score":0.3587000072002411},{"id":"https://openalex.org/C56995899","wikidata":"https://www.wikidata.org/wiki/Q1126687","display_name":"Focus group","level":2,"score":0.35690000653266907},{"id":"https://openalex.org/C166735990","wikidata":"https://www.wikidata.org/wiki/Q1750812","display_name":"Human factors and ergonomics","level":3,"score":0.32420000433921814},{"id":"https://openalex.org/C83854009","wikidata":"https://www.wikidata.org/wiki/Q16000091","display_name":"Environmental design","level":2,"score":0.3154999911785126},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.31029999256134033},{"id":"https://openalex.org/C2984241579","wikidata":"https://www.wikidata.org/wiki/Q323611","display_name":"Architectural design","level":3,"score":0.30799999833106995},{"id":"https://openalex.org/C26760741","wikidata":"https://www.wikidata.org/wiki/Q160402","display_name":"Perception","level":2,"score":0.3061999976634979},{"id":"https://openalex.org/C205300905","wikidata":"https://www.wikidata.org/wiki/Q63100","display_name":"Urban design","level":3,"score":0.3052999973297119},{"id":"https://openalex.org/C22212356","wikidata":"https://www.wikidata.org/wiki/Q775325","display_name":"Transport engineering","level":1,"score":0.3050999939441681},{"id":"https://openalex.org/C75630572","wikidata":"https://www.wikidata.org/wiki/Q538904","display_name":"Applied psychology","level":1,"score":0.30399999022483826},{"id":"https://openalex.org/C142546437","wikidata":"https://www.wikidata.org/wiki/Q2661195","display_name":"Descriptive research","level":2,"score":0.3027999997138977},{"id":"https://openalex.org/C2989191132","wikidata":"https://www.wikidata.org/wiki/Q2997557","display_name":"Fire safety","level":2,"score":0.29510000348091125},{"id":"https://openalex.org/C3017893058","wikidata":"https://www.wikidata.org/wiki/Q999278","display_name":"User satisfaction","level":2,"score":0.29319998621940613},{"id":"https://openalex.org/C114997826","wikidata":"https://www.wikidata.org/wiki/Q1072290","display_name":"Sick building syndrome","level":3,"score":0.2727999985218048},{"id":"https://openalex.org/C146508145","wikidata":"https://www.wikidata.org/wiki/Q1046315","display_name":"Level design","level":3,"score":0.2676999866962433},{"id":"https://openalex.org/C58581272","wikidata":"https://www.wikidata.org/wiki/Q12741163","display_name":"Workspace","level":3,"score":0.2603999972343445},{"id":"https://openalex.org/C21547014","wikidata":"https://www.wikidata.org/wiki/Q1423657","display_name":"Operations management","level":1,"score":0.25699999928474426},{"id":"https://openalex.org/C83849319","wikidata":"https://www.wikidata.org/wiki/Q7295720","display_name":"Rating scale","level":2,"score":0.2556000053882599},{"id":"https://openalex.org/C133462117","wikidata":"https://www.wikidata.org/wiki/Q4929239","display_name":"Data collection","level":2,"score":0.25189998745918274},{"id":"https://openalex.org/C2779318504","wikidata":"https://www.wikidata.org/wiki/Q1438035","display_name":"Research design","level":2,"score":0.2506999969482422}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.68263/bjar-ked4bzg6","doi":"https://doi.org/10.68263/bjar-ked4bzg6","is_oa":true,"landing_page_url":"https://doi.org/10.68263/bjar-ked4bzg6","pdf_url":null,"source":{"id":"https://openalex.org/S7407064920","display_name":"British Journal of Advanced Research","issn_l":"3153-709X","issn":["3153-709X"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by-nc-sa","license_id":"https://openalex.org/licenses/cc-by-nc-sa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"British Journal of Advanced Research","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.68263/bjar-ked4bzg6","doi":"https://doi.org/10.68263/bjar-ked4bzg6","is_oa":true,"landing_page_url":"https://doi.org/10.68263/bjar-ked4bzg6","pdf_url":null,"source":{"id":"https://openalex.org/S7407064920","display_name":"British Journal of Advanced Research","issn_l":"3153-709X","issn":["3153-709X"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by-nc-sa","license_id":"https://openalex.org/licenses/cc-by-nc-sa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"British Journal of Advanced Research","raw_type":"journal-article"},"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"The":[0,63,144,160,183,228],"quality":[1,111,174],"of":[2,70,101,121,136,209],"indoor":[3,72,109,172],"environments":[4],"in":[5,28,31,180,224,240],"institutional":[6,29,181,226],"buildings":[7,30],"significantly":[8],"influences":[9],"occupant":[10,24,105,156,200],"comfort,":[11],"productivity,":[12],"and":[13,26,56,68,89,114,125,152,155,158,176,194,202,216,237],"overall":[14],"well-being.":[15],"This":[16],"study":[17,145,184,229],"evaluated":[18],"human-centred":[19,188],"design":[20,45,189,193],"strategies":[21],"for":[22,166],"enhancing":[23],"comfort":[25,169],"well-being":[27,201],"Lagos,":[32],"Nigeria,":[33],"with":[34,141],"a":[35,49,76],"specific":[36],"focus":[37],"on":[38],"university":[39],"office":[40,61,94],"buildings.":[41,62,182],"A":[42],"quantitative":[43],"research":[44],"was":[46],"adopted,":[47],"utilising":[48],"structured":[50],"questionnaire":[51,64],"administered":[52],"to":[53,221,233],"55":[54],"academic":[55],"non-academic":[57],"staff":[58],"across":[59],"selected":[60],"assessed":[65],"demographic":[66],"characteristics":[67],"perceptions":[69],"twenty":[71],"environmental":[73],"elements":[74],"using":[75,83],"seven-point":[77],"rating":[78,100],"scale.":[79],"Data":[80],"were":[81],"analysed":[82],"descriptive":[84],"statistics,":[85],"including":[86],"mean":[87,99,134],"ratings":[88,135],"frequencies.":[90],"Findings":[91],"revealed":[92],"that":[93,186],"temperature":[95],"recorded":[96,131],"the":[97,129,132,163,207],"highest":[98],"7.9,":[102],"indicating":[103],"severe":[104],"dissatisfaction,":[106],"followed":[107],"by":[108],"air":[110,173],"at":[112,117],"6.6":[113],"storage":[115],"space":[116],"6.1.":[118],"Conversely,":[119],"availability":[120],"work-related":[122],"meeting":[123],"rooms":[124],"ancillary":[126],"facilities":[127],"within":[128],"building":[130,192],"lowest":[133],"3.9,":[137],"suggesting":[138],"relative":[139],"satisfaction":[140,157],"these":[142],"elements.":[143],"further":[146],"identified":[147],"significant":[148],"relationships":[149],"between":[150],"ergonomic":[151,217],"flexibility":[153],"factors":[154],"efficiency.":[159,204],"findings":[161],"underscore":[162],"critical":[164],"need":[165],"improved":[167,213],"thermal":[168],"strategies,":[170,212],"enhanced":[171],"management,":[175],"optimised":[177],"spatial":[178],"configurations":[179,219],"concludes":[185],"integrating":[187],"principles":[190],"into":[191],"facility":[195],"management":[196],"can":[197],"substantially":[198],"improve":[199],"operational":[203],"Recommendations":[205],"include":[206],"adoption":[208],"passive":[210],"cooling":[211],"ventilation":[214],"systems,":[215],"workspace":[218],"tailored":[220],"user":[222],"needs":[223],"Lagos":[225],"contexts.":[227],"contributes":[230],"context-specific":[231],"evidence":[232],"inform":[234],"architectural":[235],"practice":[236],"policy":[238],"formulation":[239],"tropical":[241],"urban":[242],"environments.":[243]},"counts_by_year":[],"updated_date":"2026-11-11T12:16:26.678958","created_date":"2026-11-11T00:00:00"}
