{"id":"https://openalex.org/W7225637345","doi":"https://doi.org/10.1080/14733315.2026.2755486","title":"Field validation of EnergyPlus predictions of indoor air temperature in a hot-humid educational building","display_name":"Field validation of EnergyPlus predictions of indoor air temperature in a hot-humid educational building","publication_year":2026,"publication_date":"2026-11-09","ids":{"openalex":"https://openalex.org/W7225637345","doi":"https://doi.org/10.1080/14733315.2026.2755486"},"language":"en","primary_location":{"id":"doi:10.1080/14733315.2026.2755486","doi":"https://doi.org/10.1080/14733315.2026.2755486","is_oa":false,"landing_page_url":"https://doi.org/10.1080/14733315.2026.2755486","pdf_url":null,"source":{"id":"https://openalex.org/S188720842","display_name":"International Journal of Ventilation","issn_l":"1473-3315","issn":["1473-3315","2044-4044"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-c","jufo-1","norway-1","poland-40","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547","https://openalex.org/P4310320449"],"host_organization_lineage_names":["Taylor & Francis","Informa"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"International Journal of Ventilation","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5159653482","display_name":"Azzam H. Alosaimi","orcid":"https://orcid.org/0000-0001-6177-194X","observed_orcids":["https://orcid.org/0000-0001-6177-194X"]},"institutions":[{"id":"https://openalex.org/I91450128","display_name":"Jazan University","ror":"https://ror.org/02bjnq803","country_code":"SA","type":"education","lineage":["https://openalex.org/I91450128"]}],"countries":["SA"],"is_corresponding":true,"raw_author_name":"Azzam H. Alosaimi","raw_affiliation_strings":["Department of Civil and Architectural Engineering, College of Engineering and Computer Science, Jazan University"],"raw_orcid":"https://orcid.org/0000-0001-6177-194X","affiliations":[{"raw_affiliation_string":"Department of Civil and Architectural Engineering, College of Engineering and Computer Science, Jazan University","institution_ids":["https://openalex.org/I91450128"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5159653482"],"corresponding_institution_ids":["https://openalex.org/I91450128"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"22"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13263","display_name":"Building energy efficiency and sustainability","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11371","display_name":"Wind and Air Flow Studies","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2305","display_name":"Environmental Engineering"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/indoor-temperature","display_name":"indoor temperature","score":0.9210000038146973},{"id":"https://openalex.org/keywords/energyplus","display_name":"EnergyPlus","score":0.8930000066757202},{"id":"https://openalex.org/keywords/building-energy-simulation","display_name":"building energy simulation","score":0.6919999718666077},{"id":"https://openalex.org/keywords/field-validation","display_name":"field validation","score":0.800000011920929},{"id":"https://openalex.org/keywords/hot-humid-climate","display_name":"hot and humid climate","score":0.9049999713897705},{"id":"https://openalex.org/keywords/educational-buildings","display_name":"educational buildings","score":0.7919999957084656},{"id":"https://openalex.org/keywords/model-calibration","display_name":"model calibration","score":0.7239999771118164},{"id":"https://openalex.org/keywords/thermal-zones","display_name":"thermal zones","score":0.5419999957084656},{"id":"https://openalex.org/keywords/university-buildings","display_name":"university buildings","score":0.503000020980835},{"id":"https://openalex.org/keywords/energy-performance-of-buildings","display_name":"building energy performance","score":0.5839999914169312}],"concepts":[{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.762499988079071},{"id":"https://openalex.org/C196803488","wikidata":"https://www.wikidata.org/wiki/Q4986592","display_name":"Building envelope","level":3,"score":0.6877999901771545},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.5407000184059143},{"id":"https://openalex.org/C153400128","wikidata":"https://www.wikidata.org/wiki/Q3150731","display_name":"Infiltration (HVAC)","level":2,"score":0.5051000118255615},{"id":"https://openalex.org/C204530211","wikidata":"https://www.wikidata.org/wiki/Q752823","display_name":"Thermal","level":2,"score":0.48420000076293945},{"id":"https://openalex.org/C2983363897","wikidata":"https://www.wikidata.org/wiki/Q845339","display_name":"Air temperature","level":2,"score":0.4819999933242798},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.4609000086784363},{"id":"https://openalex.org/C133913538","wikidata":"https://www.wikidata.org/wiki/Q774514","display_name":"Thermal comfort","level":2,"score":0.4456000030040741},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.426800012588501},{"id":"https://openalex.org/C65155139","wikidata":"https://www.wikidata.org/wiki/Q5380912","display_name":"Envelope (radar)","level":3,"score":0.4189000129699707},{"id":"https://openalex.org/C2993878198","wikidata":"https://www.wikidata.org/wiki/Q905504","display_name":"Indoor air","level":2,"score":0.4171999990940094},{"id":"https://openalex.org/C72293138","wikidata":"https://www.wikidata.org/wiki/Q909741","display_name":"Temperature measurement","level":2,"score":0.4104999899864197},{"id":"https://openalex.org/C62649853","wikidata":"https://www.wikidata.org/wiki/Q199687","display_name":"Remote sensing","level":1,"score":0.4027999937534332},{"id":"https://openalex.org/C2776409380","wikidata":"https://www.wikidata.org/wiki/Q18205688","display_name":"Building energy simulation","level":4,"score":0.4004000127315521},{"id":"https://openalex.org/C2776436953","wikidata":"https://www.wikidata.org/wiki/Q5163215","display_name":"Consistency (knowledge bases)","level":2,"score":0.3926999866962433},{"id":"https://openalex.org/C65469","wikidata":"https://www.wikidata.org/wiki/Q905504","display_name":"Indoor air quality","level":2,"score":0.38429999351501465},{"id":"https://openalex.org/C139945424","wikidata":"https://www.wikidata.org/wiki/Q1940696","display_name":"Mean squared error","level":2,"score":0.3578999936580658},{"id":"https://openalex.org/C9652623","wikidata":"https://www.wikidata.org/wiki/Q190109","display_name":"Field (mathematics)","level":2,"score":0.3257000148296356},{"id":"https://openalex.org/C199104240","wikidata":"https://www.wikidata.org/wiki/Q118291","display_name":"Marine engineering","level":1,"score":0.29989999532699585},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.2912999987602234},{"id":"https://openalex.org/C84967980","wikidata":"https://www.wikidata.org/wiki/Q3517831","display_name":"Operative temperature","level":3,"score":0.2851000130176544},{"id":"https://openalex.org/C176864760","wikidata":"https://www.wikidata.org/wiki/Q217651","display_name":"Moisture","level":2,"score":0.2840000092983246},{"id":"https://openalex.org/C3019813237","wikidata":"https://www.wikidata.org/wiki/Q65089264","display_name":"Model validation","level":2,"score":0.2818000018596649},{"id":"https://openalex.org/C177803969","wikidata":"https://www.wikidata.org/wiki/Q29205","display_name":"Uncertainty analysis","level":2,"score":0.27970001101493835},{"id":"https://openalex.org/C2982928256","wikidata":"https://www.wikidata.org/wiki/Q6865456","display_name":"Energy performance","level":3,"score":0.2777000069618225},{"id":"https://openalex.org/C2778530916","wikidata":"https://www.wikidata.org/wiki/Q1352349","display_name":"Building model","level":2,"score":0.27570000290870667},{"id":"https://openalex.org/C116067010","wikidata":"https://www.wikidata.org/wiki/Q4698686","display_name":"Airflow","level":2,"score":0.27480000257492065},{"id":"https://openalex.org/C168068576","wikidata":"https://www.wikidata.org/wiki/Q190241","display_name":"Thermocouple","level":2,"score":0.26249998807907104},{"id":"https://openalex.org/C108215451","wikidata":"https://www.wikidata.org/wiki/Q7263963","display_name":"Simulation modeling","level":2,"score":0.25609999895095825},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.2531999945640564}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1080/14733315.2026.2755486","doi":"https://doi.org/10.1080/14733315.2026.2755486","is_oa":false,"landing_page_url":"https://doi.org/10.1080/14733315.2026.2755486","pdf_url":null,"source":{"id":"https://openalex.org/S188720842","display_name":"International Journal of Ventilation","issn_l":"1473-3315","issn":["1473-3315","2044-4044"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-c","jufo-1","norway-1","poland-40","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547","https://openalex.org/P4310320449"],"host_organization_lineage_names":["Taylor & Francis","Informa"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"International Journal of Ventilation","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/13","display_name":"Climate action","score":0.5351999998092651}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":21,"referenced_works":["https://openalex.org/W1986424250","https://openalex.org/W2026213824","https://openalex.org/W2307018773","https://openalex.org/W2604004165","https://openalex.org/W2907096468","https://openalex.org/W3002702374","https://openalex.org/W3166534610","https://openalex.org/W3174166618","https://openalex.org/W3178083888","https://openalex.org/W3211962390","https://openalex.org/W4361006698","https://openalex.org/W4387632475","https://openalex.org/W4387647569","https://openalex.org/W4404635567","https://openalex.org/W4406212115","https://openalex.org/W4408151977","https://openalex.org/W4408373025","https://openalex.org/W4411867765","https://openalex.org/W4411893178","https://openalex.org/W4415644104","https://openalex.org/W7117764101"],"related_works":["https://openalex.org/W4312389324","https://openalex.org/W2913925293","https://openalex.org/W2523672120","https://openalex.org/W3215246838","https://openalex.org/W7223655099","https://openalex.org/W4291743728","https://openalex.org/W4200550594","https://openalex.org/W3165552214","https://openalex.org/W7220517308","https://openalex.org/W2595308253"],"abstract_inverted_index":{"Reliable":[0],"prediction":[1],"of":[2,38,106,111,123,146,149,154,181],"indoor":[3,29,165],"air":[4],"temperature":[5],"(IAT)":[6],"is":[7],"fundamental":[8],"to":[9,86],"building":[10,47,182],"performance":[11,184],"simulation,":[12],"particularly":[13],"in":[14,48,72],"hot-humid":[15,50],"climates":[16],"where":[17],"envelope":[18],"heat":[19],"gains,":[20],"moisture":[21],"dynamics,":[22],"and":[23,108,117,140,152,185],"cooling":[24],"system":[25],"operation":[26],"strongly":[27],"influence":[28],"conditions.":[30,171],"This":[31,172],"study":[32,173],"presents":[33],"a":[34,44,49,100,175],"rigorous":[35],"field":[36],"validation":[37],"an":[39,104,109],"EnergyPlus":[40],"model":[41],"developed":[42],"for":[43,178],"university":[45],"educational":[46],"region.":[51],"IAT":[52],"measurements":[53],"were":[54,77],"collected":[55],"using":[56],"two":[57],"HOBO":[58],"U12-012":[59],"instruments,":[60],"installed":[61],"1":[62],"m":[63],"above":[64],"the":[65,69,130,161],"floor":[66],"surface":[67],"on":[68],"second":[70],"level":[71],"representative":[73],"thermal":[74,127,166],"zones.":[75],"Data":[76],"recorded":[78],"at":[79],"regular":[80],"intervals":[81],"under":[82,168],"real":[83],"operating":[84,170],"conditions":[85],"ensure":[87],"temporal":[88],"consistency":[89],"with":[90,143],"simulation":[91,162],"outputs.":[92],"Instrument":[93],"verification":[94],"demonstrated":[95],"high":[96],"measurement":[97],"reliability":[98],"within":[99,129],"single":[101],"zone,":[102],"yielding":[103],"R2":[105,121,144],"0.98":[107],"RMSE":[110,148],"0.28":[112],"\u00b0C.":[113,156],"Comparisons":[114],"between":[115,138],"north":[116],"south":[118],"zones":[119],"produced":[120],"values":[122,145],"0.83\u20130.90,":[124],"reflecting":[125],"spatial":[126],"variability":[128],"building.":[131],"Model":[132],"calibration":[133],"results":[134,158],"showed":[135],"strong":[136],"agreement":[137],"simulated":[139],"measured":[141],"IAT,":[142],"0.82\u20130.89,":[147],"0.08\u20130.11":[150],"\u00b0C,":[151],"MBE":[153],"0.03\u20130.08":[155],"These":[157],"confirm":[159],"that":[160],"reliably":[163],"reproduces":[164],"behaviour":[167],"dynamic":[169],"provides":[174],"robust":[176],"framework":[177],"subsequent":[179],"analyses":[180],"energy":[183],"infiltration":[186],"impacts.":[187]},"counts_by_year":[],"updated_date":"2026-11-11T12:16:26.678958","created_date":"2026-11-10T00:00:00"}
