{"id":"https://openalex.org/W7225588653","doi":"https://doi.org/10.5370/kiee.2026.75.11.3014","title":"Task-Specific Arc-Flash Incident-Energy Analysis and Protection Criteria Using Field Incident Data and PSCAD in the Electric Power Industry","display_name":"Task-Specific Arc-Flash Incident-Energy Analysis and Protection Criteria Using Field Incident Data and PSCAD in the Electric Power Industry","publication_year":2026,"publication_date":"2026-11-09","ids":{"openalex":"https://openalex.org/W7225588653","doi":"https://doi.org/10.5370/kiee.2026.75.11.3014"},"language":"en","primary_location":{"id":"doi:10.5370/kiee.2026.75.11.3014","doi":"https://doi.org/10.5370/kiee.2026.75.11.3014","is_oa":false,"landing_page_url":"https://doi.org/10.5370/kiee.2026.75.11.3014","pdf_url":null,"source":{"id":"https://openalex.org/S2764620966","display_name":"The Transactions of The Korean Institute of Electrical Engineers","issn_l":"1975-8359","issn":["1975-8359","2287-4364"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["kci-registered","poland-20","russia-white-list-4"],"host_organization":"https://openalex.org/P4322697825","host_organization_name":"Korean Institute of Electrical Engineers","host_organization_lineage":["https://openalex.org/P4322697825"],"host_organization_lineage_names":["Korean Institute of Electrical Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"The transactions of The Korean Institute of Electrical Engineers","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5161284326","display_name":"Dongyeop Lee","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Dongyeop Lee","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5096199182","display_name":"Daesik Lim","orcid":"https://orcid.org/0000-0002-8692-2510","observed_orcids":["https://orcid.org/0000-0002-8692-2510"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Daesik Lim","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5161301985","display_name":"Kihyun Kim","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Kihyun Kim","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"75","issue":"11","first_page":"3014","last_page":"3022"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.8862000107765198,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.8862000107765198,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12077","display_name":"Vacuum and Plasma Arcs","score":0.02759999968111515,"subfield":{"id":"https://openalex.org/subfields/3107","display_name":"Atomic and Molecular Physics, and Optics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.01679999940097332,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/arc-flash","display_name":"arc flash","score":0.8420000076293945},{"id":"https://openalex.org/keywords/incident-energy","display_name":"incident energy","score":0.9079999923706055},{"id":"https://openalex.org/keywords/protection-criteria","display_name":"protection criteria","score":0.7360000014305115},{"id":"https://openalex.org/keywords/pscad-emtdc-simulation","display_name":"PSCAD/EMTDC simulation","score":0.6930000185966492},{"id":"https://openalex.org/keywords/personal-protective-equipment","display_name":"personal protective equipment","score":0.7020000219345093},{"id":"https://openalex.org/keywords/working-distance","display_name":"working distance","score":0.890999972820282},{"id":"https://openalex.org/keywords/electrical-safety","display_name":"electrical safety","score":0.44999998807907104}],"concepts":[{"id":"https://openalex.org/C9652623","wikidata":"https://www.wikidata.org/wiki/Q190109","display_name":"Field (mathematics)","level":2,"score":0.5277000069618225},{"id":"https://openalex.org/C170777988","wikidata":"https://www.wikidata.org/wiki/Q2316331","display_name":"Electric power industry","level":3,"score":0.4991999864578247},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4699000120162964},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.46059998869895935},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4388999938964844},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3864000141620636},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3671000003814697},{"id":"https://openalex.org/C40293303","wikidata":"https://www.wikidata.org/wiki/Q27137","display_name":"Electric power","level":3,"score":0.3546999990940094},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.34139999747276306},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.3407999873161316},{"id":"https://openalex.org/C2779665505","wikidata":"https://www.wikidata.org/wiki/Q1780079","display_name":"Power quality","level":3,"score":0.33410000801086426},{"id":"https://openalex.org/C60799052","wikidata":"https://www.wikidata.org/wiki/Q46221","display_name":"Electric field","level":2,"score":0.28690001368522644},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.2531999945640564}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.5370/kiee.2026.75.11.3014","doi":"https://doi.org/10.5370/kiee.2026.75.11.3014","is_oa":false,"landing_page_url":"https://doi.org/10.5370/kiee.2026.75.11.3014","pdf_url":null,"source":{"id":"https://openalex.org/S2764620966","display_name":"The Transactions of The Korean Institute of Electrical Engineers","issn_l":"1975-8359","issn":["1975-8359","2287-4364"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["kci-registered","poland-20","russia-white-list-4"],"host_organization":"https://openalex.org/P4322697825","host_organization_name":"Korean Institute of Electrical Engineers","host_organization_lineage":["https://openalex.org/P4322697825"],"host_organization_lineage_names":["Korean Institute of Electrical Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"The transactions of The Korean Institute of Electrical Engineers","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W7152996668","https://openalex.org/W4391135680","https://openalex.org/W2807941192","https://openalex.org/W7026901386","https://openalex.org/W7211950661","https://openalex.org/W7204841311","https://openalex.org/W3019477607","https://openalex.org/W2770391342","https://openalex.org/W7204794125","https://openalex.org/W7204827287"],"abstract_inverted_index":{"This":[0],"study":[1],"develops":[2],"task-specific":[3],"arc-flash":[4],"incident-energy":[5],"analysis":[6,105],"and":[7,35,46,63,87,133],"protection":[8,148],"criteria":[9],"using":[10,42],"41":[11],"accidents":[12],"in":[13,24],"power":[14],"facilities":[15],"from":[16,54,64],"2018":[17],"to":[18,56,66],"2023.":[19],"Each":[20],"case":[21],"was":[22,40,76,107,117],"reconstructed":[23],"PSCAD/EMTDC":[25],"with":[26],"system":[27],"impedance,":[28],"fault":[29],"type,":[30],"working":[31,98],"distance,":[32],"equipment":[33],"geometry,":[34],"protective-device":[36],"characteristics.":[37],"Incident":[38],"energy":[39,129,144],"calculated":[41],"IEEE":[43],"Std":[44],"1584-2018":[45],"a":[47],"high-voltage":[48,71,83],"arc":[49,121],"model.":[50],"The":[51],"results":[52],"ranged":[53],"1.37":[55],"127.1":[57],"J/cm\u00b2":[58,68],"for":[59,69,109],"14":[60],"low-voltage":[61],"cases":[62],"12.7":[65],"613.6":[67],"27":[70],"cases.":[72],"Low-voltage":[73],"metering":[74],"work":[75,135],"dominated":[77],"by":[78,92],"delayed":[79],"upstream-fuse":[80],"clearing,":[81],"whereas":[82],"transformer,":[84],"switchgear,":[85],"VLF,":[86],"MOF":[88],"tasks":[89],"were":[90],"affected":[91],"long":[93],"clearing":[94],"times":[95],"or":[96,125,142],"short":[97],"distances.":[99],"Only":[100],"the":[101,112,146],"NFPA":[102],"70E":[103],"incidentenergy":[104],"method":[106,116],"used":[108],"PPE":[110,113,120],"selection;":[111],"category":[114],"table":[115],"not":[118],"applied.":[119],"ratings":[122],"must":[123],"equal":[124],"exceed":[126],"residual":[127,143],"incident":[128],"after":[130],"engineering":[131],"controls,":[132],"de-energized":[134],"is":[136],"prioritized":[137],"when":[138],"inputs":[139],"are":[140],"uncertain":[141],"exceeds":[145],"available":[147],"system.":[149]},"counts_by_year":[],"updated_date":"2026-11-11T12:16:26.678958","created_date":"2026-11-09T00:00:00"}
