{"id":"https://openalex.org/W7225580556","doi":"https://doi.org/10.5370/kiee.2026.75.11.2864","title":"Comparison of Model Parameter Derivation Accuracy Between a PMU-Based Generator Measurement System and Conventional Test Equipment: Field Demonstration at Muju Pumped-Storage Unit 1","display_name":"Comparison of Model Parameter Derivation Accuracy Between a PMU-Based Generator Measurement System and Conventional Test Equipment: Field Demonstration at Muju Pumped-Storage Unit 1","publication_year":2026,"publication_date":"2026-11-09","ids":{"openalex":"https://openalex.org/W7225580556","doi":"https://doi.org/10.5370/kiee.2026.75.11.2864"},"language":"en","primary_location":{"id":"doi:10.5370/kiee.2026.75.11.2864","doi":"https://doi.org/10.5370/kiee.2026.75.11.2864","is_oa":false,"landing_page_url":"https://doi.org/10.5370/kiee.2026.75.11.2864","pdf_url":null,"source":{"id":"https://openalex.org/S2764620966","display_name":"The Transactions of The Korean Institute of Electrical Engineers","issn_l":"1975-8359","issn":["1975-8359","2287-4364"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["kci-registered","poland-20","russia-white-list-4"],"host_organization":"https://openalex.org/P4322697825","host_organization_name":"Korean Institute of Electrical Engineers","host_organization_lineage":["https://openalex.org/P4322697825"],"host_organization_lineage_names":["Korean Institute of Electrical Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"The transactions of The Korean Institute of Electrical Engineers","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5007970746","display_name":"Jeongmin Mun","orcid":"https://orcid.org/0000-0003-4188-2049","observed_orcids":["https://orcid.org/0000-0003-4188-2049"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Jeong-Min Mun","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5161271699","display_name":"Hyun-Ho Yang","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Hyun-Ho Yang","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5161296949","display_name":"Jeong-Uk Kim","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Jeong-Uk Kim","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"75","issue":"11","first_page":"2864","last_page":"2871"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14276","display_name":"Power Systems and Technologies","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/phasor-measurement-units","display_name":"phasor measurement units","score":0.9459999799728394},{"id":"https://openalex.org/keywords/permanent-magnet-synchronous-generator","display_name":"permanent magnet synchronous generator","score":0.593999981880188},{"id":"https://openalex.org/keywords/pumped-storage-units","display_name":"pumped storage units","score":0.6779999732971191},{"id":"https://openalex.org/keywords/measurement-accuracy","display_name":"measurement accuracy","score":0.43799999356269836},{"id":"https://openalex.org/keywords/measurement-error","display_name":"measurement error","score":0.46000000834465027}],"concepts":[{"id":"https://openalex.org/C2780992000","wikidata":"https://www.wikidata.org/wiki/Q17016113","display_name":"Generator (circuit theory)","level":3,"score":0.5895000100135803},{"id":"https://openalex.org/C9652623","wikidata":"https://www.wikidata.org/wiki/Q190109","display_name":"Field (mathematics)","level":2,"score":0.5669000148773193},{"id":"https://openalex.org/C37649242","wikidata":"https://www.wikidata.org/wiki/Q932268","display_name":"System of measurement","level":2,"score":0.4966000020503998},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.46320000290870667},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4198000133037567},{"id":"https://openalex.org/C19619285","wikidata":"https://www.wikidata.org/wiki/Q196372","display_name":"Observational error","level":2,"score":0.414000004529953},{"id":"https://openalex.org/C122637931","wikidata":"https://www.wikidata.org/wiki/Q118084","display_name":"Unit (ring theory)","level":2,"score":0.3605000078678131},{"id":"https://openalex.org/C137209882","wikidata":"https://www.wikidata.org/wiki/Q1403517","display_name":"Measurement uncertainty","level":2,"score":0.3474999964237213},{"id":"https://openalex.org/C2778229166","wikidata":"https://www.wikidata.org/wiki/Q8290","display_name":"Phasor measurement unit","level":5,"score":0.34630000591278076},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.33959999680519104},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.33869999647140503},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.32330000400543213},{"id":"https://openalex.org/C62646347","wikidata":"https://www.wikidata.org/wiki/Q2041172","display_name":"Measuring instrument","level":2,"score":0.29760000109672546},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.2971999943256378},{"id":"https://openalex.org/C76249512","wikidata":"https://www.wikidata.org/wiki/Q1206780","display_name":"Device under test","level":3,"score":0.2542000114917755}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.5370/kiee.2026.75.11.2864","doi":"https://doi.org/10.5370/kiee.2026.75.11.2864","is_oa":false,"landing_page_url":"https://doi.org/10.5370/kiee.2026.75.11.2864","pdf_url":null,"source":{"id":"https://openalex.org/S2764620966","display_name":"The Transactions of The Korean Institute of Electrical Engineers","issn_l":"1975-8359","issn":["1975-8359","2287-4364"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["kci-registered","poland-20","russia-white-list-4"],"host_organization":"https://openalex.org/P4322697825","host_organization_name":"Korean Institute of Electrical Engineers","host_organization_lineage":["https://openalex.org/P4322697825"],"host_organization_lineage_names":["Korean Institute of Electrical Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"The transactions of The Korean Institute of Electrical Engineers","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.75}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W3180910215","https://openalex.org/W4244894228","https://openalex.org/W6885202678","https://openalex.org/W2940796481","https://openalex.org/W2143174029","https://openalex.org/W2357775110","https://openalex.org/W2586604734","https://openalex.org/W2742477497","https://openalex.org/W2505655973","https://openalex.org/W6987400623"],"abstract_inverted_index":{"This":[0],"study":[1],"evaluates":[2],"the":[3,86,95,152,172],"accuracy":[4],"of":[5,90,103,107,143,154,171],"model":[6,76],"parameter":[7,50,147],"derivation":[8],"using":[9,43],"a":[10,47,99],"phasor":[11],"measurement":[12,17,88,122,137],"unit":[13],"(PMU)-based":[14],"permanently":[15],"installed":[16],"system":[18],"by":[19],"comparing":[20],"its":[21],"results":[22],"with":[23],"those":[24],"obtained":[25],"from":[26],"conventional":[27],"test":[28,166],"equipment":[29,125],"at":[30,98],"Muju":[31],"Pumped-Storage":[32],"Unit":[33],"1":[34],"(343":[35],"MVA).":[36],"Seven":[37],"characterization":[38],"tests":[39],"were":[40,78,114],"conducted":[41],"simultaneously":[42],"both":[44],"systems,":[45],"and":[46,74,111,129],"standard":[48],"eight-step":[49],"estimation":[51],"algorithm":[52],"was":[53],"applied":[54],"independently":[55],"to":[56,71,80],"each":[57],"dataset.":[58],"Raw":[59],"measurements":[60],"exhibited":[61],"minor":[62],"differences":[63,89,138],"(base":[64],"field":[65],"current":[66],"0.023%,":[67],"saturation":[68],"coefficients":[69],"up":[70],"0.81%).":[72],"GENSAE":[73],"ESST4B":[75],"parameters":[77,97,113],"identical":[79],"three":[81],"decimal":[82],"places,":[83],"indicating":[84],"that":[85,135],"observed":[87],"\u22641%":[91],"did":[92],"not":[93],"affect":[94],"derived":[96],"single":[100],"operating":[101],"point":[102],"71.2":[104],"MW":[105],"(20.76%":[106],"rated":[108],"capacity).":[109],"PSS2A":[110],"HYGOV":[112],"validated":[115],"without":[116],"re-derivation.":[117],"A":[118],"three-level":[119],"comparison":[120],"\u2014":[121,133],"error":[123],"(\u22641%),":[124],"replacement":[126],"effect":[127],"(4\u201312%),":[128],"design-field":[130],"discrepancy":[131],"(8\u201350%)":[132],"shows":[134],"PMU":[136],"are":[139],"approximately":[140],"one":[141],"order":[142],"magnitude":[144],"smaller":[145],"than":[146],"changes":[148],"requiring":[149],"re-determination.":[150],"Within":[151],"scope":[153],"this":[155],"single-unit,":[156],"single-point":[157],"demonstration,":[158],"these":[159],"findings":[160],"provide":[161],"preliminary":[162],"evidence":[163],"supporting":[164],"PMU-based":[165],"exemption":[167],"under":[168],"Article":[169],"37":[170],"Korean":[173],"Grid":[174],"Reliability":[175],"Standards.":[176]},"counts_by_year":[],"updated_date":"2026-11-11T12:16:26.678958","created_date":"2026-11-09T00:00:00"}
