{"id":"https://openalex.org/W7225565266","doi":"https://doi.org/10.5370/kiee.2026.75.11.3032","title":"Development of a Digital Twin-Based Safety Management System for Energy Storage System","display_name":"Development of a Digital Twin-Based Safety Management System for Energy Storage System","publication_year":2026,"publication_date":"2026-11-09","ids":{"openalex":"https://openalex.org/W7225565266","doi":"https://doi.org/10.5370/kiee.2026.75.11.3032"},"language":"en","primary_location":{"id":"doi:10.5370/kiee.2026.75.11.3032","doi":"https://doi.org/10.5370/kiee.2026.75.11.3032","is_oa":false,"landing_page_url":"https://doi.org/10.5370/kiee.2026.75.11.3032","pdf_url":null,"source":{"id":"https://openalex.org/S2764620966","display_name":"The Transactions of The Korean Institute of Electrical Engineers","issn_l":"1975-8359","issn":["1975-8359","2287-4364"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["kci-registered","poland-20","russia-white-list-4"],"host_organization":"https://openalex.org/P4322697825","host_organization_name":"Korean Institute of Electrical Engineers","host_organization_lineage":["https://openalex.org/P4322697825"],"host_organization_lineage_names":["Korean Institute of Electrical Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"The transactions of The Korean Institute of Electrical Engineers","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5017404065","display_name":"Youna Kim","orcid":"https://orcid.org/0000-0003-0221-5526","observed_orcids":["https://orcid.org/0000-0003-0221-5526"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"You-Na Kim","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5161270671","display_name":"Ho-min Kim","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Ho-min Kim","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5042256367","display_name":"Hye-Ryeon Jeon","orcid":"https://orcid.org/0000-0003-2660-7145","observed_orcids":["https://orcid.org/0000-0003-2660-7145"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Hye-Ryeon Jeon","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5022182156","display_name":"Sangjae Choi","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Sangjae Choi","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5059773924","display_name":"Pil-Sung Woo","orcid":"https://orcid.org/0000-0002-1977-6250","observed_orcids":["https://orcid.org/0000-0002-1977-6250"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Pil-Sung Woo","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"75","issue":"11","first_page":"3032","last_page":"3039"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10663","display_name":"Battery Modeling and Management","score":0.7484999895095825,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10663","display_name":"Battery Modeling and Management","score":0.7484999895095825,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10763","display_name":"Digital Transformation in Industry","score":0.09960000216960907,"subfield":{"id":"https://openalex.org/subfields/2209","display_name":"Industrial and Manufacturing Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.02759999968111515,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/digital-twin","display_name":"digital twin","score":0.9850000143051147},{"id":"https://openalex.org/keywords/energy-storage-systems","display_name":"energy storage systems","score":0.8610000014305115},{"id":"https://openalex.org/keywords/safety-management","display_name":"safety management","score":0.9570000171661377},{"id":"https://openalex.org/keywords/battery-state-of-health-estimation","display_name":"battery state of health estimation","score":0.8650000095367432},{"id":"https://openalex.org/keywords/battery-equivalent-circuit-model","display_name":"battery equivalent circuit model","score":0.902999997138977},{"id":"https://openalex.org/keywords/fault-simulation","display_name":"fault simulation","score":0.6420000195503235},{"id":"https://openalex.org/keywords/lifetime-prediction","display_name":"lifetime prediction","score":0.7910000085830688},{"id":"https://openalex.org/keywords/energy-management-strategy","display_name":"energy management strategy","score":0.8029999732971191},{"id":"https://openalex.org/keywords/real-time-monitoring","display_name":"real-time monitoring","score":0.9459999799728394}],"concepts":[{"id":"https://openalex.org/C201995342","wikidata":"https://www.wikidata.org/wiki/Q682496","display_name":"Systems engineering","level":1,"score":0.5078999996185303},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5034999847412109},{"id":"https://openalex.org/C198783460","wikidata":"https://www.wikidata.org/wiki/Q629173","display_name":"Management system","level":2,"score":0.4925999939441681},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.46799999475479126},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.4187000095844269},{"id":"https://openalex.org/C132835097","wikidata":"https://www.wikidata.org/wiki/Q7663745","display_name":"System safety","level":2,"score":0.37549999356269836},{"id":"https://openalex.org/C194739806","wikidata":"https://www.wikidata.org/wiki/Q66221","display_name":"Computer data storage","level":2,"score":0.3698999881744385},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3693999946117401},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.366100013256073},{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.3571999967098236},{"id":"https://openalex.org/C2776542497","wikidata":"https://www.wikidata.org/wiki/Q5266672","display_name":"Development (topology)","level":2,"score":0.34299999475479126},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.32839998602867126},{"id":"https://openalex.org/C2781260460","wikidata":"https://www.wikidata.org/wiki/Q6139999","display_name":"Energy management system","level":4,"score":0.31290000677108765},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.27720001339912415},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.26980000734329224},{"id":"https://openalex.org/C145798840","wikidata":"https://www.wikidata.org/wiki/Q7247299","display_name":"Process safety management","level":3,"score":0.250900000333786}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.5370/kiee.2026.75.11.3032","doi":"https://doi.org/10.5370/kiee.2026.75.11.3032","is_oa":false,"landing_page_url":"https://doi.org/10.5370/kiee.2026.75.11.3032","pdf_url":null,"source":{"id":"https://openalex.org/S2764620966","display_name":"The Transactions of The Korean Institute of Electrical Engineers","issn_l":"1975-8359","issn":["1975-8359","2287-4364"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["kci-registered","poland-20","russia-white-list-4"],"host_organization":"https://openalex.org/P4322697825","host_organization_name":"Korean Institute of Electrical Engineers","host_organization_lineage":["https://openalex.org/P4322697825"],"host_organization_lineage_names":["Korean Institute of Electrical Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"The transactions of The Korean Institute of Electrical Engineers","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.9853000044822693,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"},{"score":0.8970999717712402,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W4392091479","https://openalex.org/W4386989835","https://openalex.org/W7225598034","https://openalex.org/W7027432158","https://openalex.org/W7083678275","https://openalex.org/W7125515816","https://openalex.org/W7163307137","https://openalex.org/W4200028139","https://openalex.org/W7134968962","https://openalex.org/W7167584220"],"abstract_inverted_index":{"This":[0],"study":[1],"proposes":[2],"a":[3,50,129],"digital":[4,34,41],"twin":[5,35,42],"model":[6,54],"and":[7,25,37,49,70,80,96,107,116,124],"simulation":[8,117],"system":[9,19,61],"for":[10,131],"safety":[11,134],"management":[12],"of":[13,21,89,94,100],"energy":[14],"storage":[15],"systems":[16],"(ESS).":[17],"The":[18,60],"consists":[20],"physical,":[22],"data,":[23,115],"platform,":[24],"service":[26],"layers":[27],"integrating":[28,111],"field":[29],"facilities,":[30],"an":[31],"integrated":[32,81],"DBMS,":[33],"simulation,":[36,69,77],"services.":[38],"A":[39],"field-synchronized":[40],"is":[43,62],"constructed":[44],"using":[45],"LiDAR-based":[46],"3D":[47],"modeling":[48],"battery":[51,87],"equivalent":[52],"circuit":[53],"(ECM)":[55],"trained":[56],"with":[57],"operational":[58,114],"data.":[59],"implemented":[63],"in":[64],"four":[65],"stages:":[66],"representation,":[67],"monitoring,":[68],"federation.":[71],"It":[72],"supports":[73],"lifetime":[74],"prediction,":[75],"fault":[76,105],"grid-connected":[78],"analysis,":[79],"control":[82],"simulation.":[83],"These":[84],"functions":[85],"provide":[86],"state":[88],"health":[90],"(SOH)":[91],"estimation,":[92],"analysis":[93],"voltage":[95],"temperature":[97],"faults,":[98],"assessment":[99],"Power":[101],"Conversion":[102],"System":[103],"(PCS)":[104],"impacts,":[106],"energy-management":[108],"strategies.":[109],"By":[110],"ESS":[112,133],"models,":[113],"functions,":[118],"the":[119],"framework":[120],"enables":[121],"real-time":[122],"monitoring":[123],"predictive":[125],"decision":[126],"support,":[127],"providing":[128],"basis":[130],"preventive":[132],"management.":[135]},"counts_by_year":[],"updated_date":"2026-11-11T12:16:26.678958","created_date":"2026-11-09T00:00:00"}
