{"id":"https://openalex.org/W7225323888","doi":"https://doi.org/10.1080/01457632.2026.2752479","title":"Novel Heat Pipe Assembly for Enhanced Thermal Performance of Air-Cooled Condenser","display_name":"Novel Heat Pipe Assembly for Enhanced Thermal Performance of Air-Cooled Condenser","publication_year":2026,"publication_date":"2026-11-05","ids":{"openalex":"https://openalex.org/W7225323888","doi":"https://doi.org/10.1080/01457632.2026.2752479"},"language":"en","primary_location":{"id":"doi:10.1080/01457632.2026.2752479","doi":"https://doi.org/10.1080/01457632.2026.2752479","is_oa":false,"landing_page_url":"https://doi.org/10.1080/01457632.2026.2752479","pdf_url":null,"source":{"id":"https://openalex.org/S118009772","display_name":"Heat Transfer Engineering","issn_l":"0145-7632","issn":["0145-7632","1521-0537"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","jufo-1","norway-1","poland-70","russia-white-list-2"],"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547","https://openalex.org/P4310320449"],"host_organization_lineage_names":["Taylor & Francis","Informa"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Heat Transfer Engineering","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5089596120","display_name":"Masoud Darbandi","orcid":"https://orcid.org/0000-0003-3361-2743","observed_orcids":["https://orcid.org/0000-0003-3361-2743"]},"institutions":[{"id":"https://openalex.org/I133529467","display_name":"Sharif University of Technology","ror":"https://ror.org/024c2fq17","country_code":"IR","type":"education","lineage":["https://openalex.org/I133529467"]}],"countries":["IR"],"is_corresponding":true,"raw_author_name":"Masoud Darbandi","raw_affiliation_strings":["Department of Aerospace Engineering, Sharif University of Technology"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Aerospace Engineering, Sharif University of Technology","institution_ids":["https://openalex.org/I133529467"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5091531188","display_name":"Kazem Mashayekh","orcid":"https://orcid.org/0009-0000-7442-1244","observed_orcids":["https://orcid.org/0009-0000-7442-1244"]},"institutions":[{"id":"https://openalex.org/I133529467","display_name":"Sharif University of Technology","ror":"https://ror.org/024c2fq17","country_code":"IR","type":"education","lineage":["https://openalex.org/I133529467"]}],"countries":["IR"],"is_corresponding":false,"raw_author_name":"Kazem Mashayekh","raw_affiliation_strings":["Center for Developing Modern Energy Systems, Sharif University of Technology"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Center for Developing Modern Energy Systems, Sharif University of Technology","institution_ids":["https://openalex.org/I133529467"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5160933900","display_name":"Fakhereh Seyedi","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I48379061","display_name":"Shahid Beheshti University","ror":"https://ror.org/0091vmj44","country_code":"IR","type":"education","lineage":["https://openalex.org/I48379061"]}],"countries":["IR"],"is_corresponding":false,"raw_author_name":"Fakhereh Seyedi","raw_affiliation_strings":["Department of Mechanical & Energy Engineering, Shahid Beheshti University"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Mechanical & Energy Engineering, Shahid Beheshti University","institution_ids":["https://openalex.org/I48379061"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5089596120"],"corresponding_institution_ids":["https://openalex.org/I133529467"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"14"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10850","display_name":"Heat Transfer and Boiling Studies","score":0.9429000020027161,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10850","display_name":"Heat Transfer and Boiling Studies","score":0.9429000020027161,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.027899999171495438,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10998","display_name":"Heat Transfer and Optimization","score":0.025100000202655792,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/heat-pipes","display_name":"heat pipes","score":0.765999972820282},{"id":"https://openalex.org/keywords/air-cooled-condenser","display_name":"air-cooled condenser","score":0.9599999785423279},{"id":"https://openalex.org/keywords/heat-transfer-enhancement","display_name":"heat transfer enhancement","score":0.6579999923706055},{"id":"https://openalex.org/keywords/radiator-fins","display_name":"radiator fins","score":0.7409999966621399},{"id":"https://openalex.org/keywords/r-134a","display_name":"R134a","score":0.878000020980835},{"id":"https://openalex.org/keywords/ambient-temperature-effects","display_name":"ambient temperature effects","score":0.8629999756813049},{"id":"https://openalex.org/keywords/part-load-operation","display_name":"off-design operation","score":0.5350000262260437},{"id":"https://openalex.org/keywords/heat-rejection-rate","display_name":"heat rejection rate","score":0.5350000262260437}],"concepts":[{"id":"https://openalex.org/C2780934509","wikidata":"https://www.wikidata.org/wiki/Q571589","display_name":"Condenser (optics)","level":3,"score":0.7746999859809875},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.692300021648407},{"id":"https://openalex.org/C199499590","wikidata":"https://www.wikidata.org/wiki/Q266790","display_name":"Refrigerant","level":3,"score":0.6541000008583069},{"id":"https://openalex.org/C63034144","wikidata":"https://www.wikidata.org/wiki/Q1163026","display_name":"Radiator (engine cooling)","level":2,"score":0.623199999332428},{"id":"https://openalex.org/C50517652","wikidata":"https://www.wikidata.org/wiki/Q179635","display_name":"Heat transfer","level":2,"score":0.6208000183105469},{"id":"https://openalex.org/C75892298","wikidata":"https://www.wikidata.org/wiki/Q1366187","display_name":"Mass flow rate","level":2,"score":0.5485000014305115},{"id":"https://openalex.org/C24730887","wikidata":"https://www.wikidata.org/wiki/Q6675830","display_name":"Loop heat pipe","level":4,"score":0.5235999822616577},{"id":"https://openalex.org/C204530211","wikidata":"https://www.wikidata.org/wiki/Q752823","display_name":"Thermal","level":2,"score":0.5113000273704529},{"id":"https://openalex.org/C186937647","wikidata":"https://www.wikidata.org/wiki/Q1796959","display_name":"Heat sink","level":2,"score":0.4749000072479248},{"id":"https://openalex.org/C172120300","wikidata":"https://www.wikidata.org/wiki/Q1134348","display_name":"Volumetric flow rate","level":2,"score":0.4480000138282776},{"id":"https://openalex.org/C2778547687","wikidata":"https://www.wikidata.org/wiki/Q193886","display_name":"Cooling tower","level":3,"score":0.382099986076355},{"id":"https://openalex.org/C37728375","wikidata":"https://www.wikidata.org/wiki/Q600568","display_name":"Heat pipe","level":3,"score":0.3790000081062317},{"id":"https://openalex.org/C137693562","wikidata":"https://www.wikidata.org/wiki/Q899628","display_name":"Thermal resistance","level":3,"score":0.37720000743865967},{"id":"https://openalex.org/C135824740","wikidata":"https://www.wikidata.org/wiki/Q15273089","display_name":"Surface condenser","level":4,"score":0.3702000081539154},{"id":"https://openalex.org/C107706546","wikidata":"https://www.wikidata.org/wiki/Q189124","display_name":"Heat exchanger","level":2,"score":0.36340001225471497},{"id":"https://openalex.org/C116915560","wikidata":"https://www.wikidata.org/wiki/Q83504","display_name":"Nuclear engineering","level":1,"score":0.3589000105857849},{"id":"https://openalex.org/C128014804","wikidata":"https://www.wikidata.org/wiki/Q3150682","display_name":"Thermal mass","level":3,"score":0.3580999970436096},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.3506999909877777},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.3433000147342682},{"id":"https://openalex.org/C91721477","wikidata":"https://www.wikidata.org/wiki/Q778612","display_name":"Fin","level":2,"score":0.33410000801086426},{"id":"https://openalex.org/C29700514","wikidata":"https://www.wikidata.org/wiki/Q634340","display_name":"Heat transfer coefficient","level":3,"score":0.3319999873638153},{"id":"https://openalex.org/C131321042","wikidata":"https://www.wikidata.org/wiki/Q656685","display_name":"Operating temperature","level":2,"score":0.3149000108242035},{"id":"https://openalex.org/C7694927","wikidata":"https://www.wikidata.org/wiki/Q7667810","display_name":"Water cooling","level":2,"score":0.3118000030517578},{"id":"https://openalex.org/C38349280","wikidata":"https://www.wikidata.org/wiki/Q1434290","display_name":"Flow (mathematics)","level":2,"score":0.3091999888420105},{"id":"https://openalex.org/C42058472","wikidata":"https://www.wikidata.org/wiki/Q810214","display_name":"Base (topology)","level":2,"score":0.29280000925064087},{"id":"https://openalex.org/C2779301550","wikidata":"https://www.wikidata.org/wiki/Q217236","display_name":"Working fluid","level":2,"score":0.2831999957561493},{"id":"https://openalex.org/C164915370","wikidata":"https://www.wikidata.org/wiki/Q5167494","display_name":"Cooling capacity","level":2,"score":0.28029999136924744},{"id":"https://openalex.org/C9930424","wikidata":"https://www.wikidata.org/wiki/Q7426587","display_name":"Saturation (graph theory)","level":2,"score":0.2793999910354614},{"id":"https://openalex.org/C159188206","wikidata":"https://www.wikidata.org/wiki/Q1478382","display_name":"Heat flux","level":3,"score":0.27709999680519104},{"id":"https://openalex.org/C194945478","wikidata":"https://www.wikidata.org/wiki/Q5693253","display_name":"Heat capacity rate","level":4,"score":0.25929999351501465},{"id":"https://openalex.org/C51038369","wikidata":"https://www.wikidata.org/wiki/Q909534","display_name":"Mass transfer","level":2,"score":0.25609999895095825}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1080/01457632.2026.2752479","doi":"https://doi.org/10.1080/01457632.2026.2752479","is_oa":false,"landing_page_url":"https://doi.org/10.1080/01457632.2026.2752479","pdf_url":null,"source":{"id":"https://openalex.org/S118009772","display_name":"Heat Transfer Engineering","issn_l":"0145-7632","issn":["0145-7632","1521-0537"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","jufo-1","norway-1","poland-70","russia-white-list-2"],"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547","https://openalex.org/P4310320449"],"host_organization_lineage_names":["Taylor & Francis","Informa"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Heat Transfer Engineering","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.75,"display_name":"Affordable and clean energy"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":35,"referenced_works":["https://openalex.org/W1969964099","https://openalex.org/W1971289728","https://openalex.org/W1973478734","https://openalex.org/W1984987217","https://openalex.org/W1985627249","https://openalex.org/W2008334131","https://openalex.org/W2008831611","https://openalex.org/W2023419907","https://openalex.org/W2032762880","https://openalex.org/W2041582376","https://openalex.org/W2045394384","https://openalex.org/W2050196522","https://openalex.org/W2056164003","https://openalex.org/W2066904751","https://openalex.org/W2094840985","https://openalex.org/W2101937334","https://openalex.org/W2113964962","https://openalex.org/W2128958637","https://openalex.org/W2137142578","https://openalex.org/W2266661517","https://openalex.org/W2501547993","https://openalex.org/W2587293036","https://openalex.org/W2763587136","https://openalex.org/W2799879329","https://openalex.org/W2895957144","https://openalex.org/W2908229431","https://openalex.org/W2980968243","https://openalex.org/W3112817175","https://openalex.org/W3160501891","https://openalex.org/W3169784767","https://openalex.org/W3178611037","https://openalex.org/W4309825684","https://openalex.org/W4317636707","https://openalex.org/W4391171786","https://openalex.org/W4402640167"],"related_works":["https://openalex.org/W4317636707","https://openalex.org/W2122207710","https://openalex.org/W2030141026","https://openalex.org/W2047278393","https://openalex.org/W2604457976","https://openalex.org/W4213153797","https://openalex.org/W3003977104","https://openalex.org/W4415822460","https://openalex.org/W3092136625","https://openalex.org/W2587293036"],"abstract_inverted_index":{"A":[0],"significant":[1],"constraint":[2],"in":[3,88,153,197],"enhancing":[4],"the":[5,13,19,31,60,65,68,73,77,84,128,166,171,176,180,190,206],"heat":[6,55,155,172,198],"transfer":[7,173,199],"efficiency":[8],"of":[9,21,67,76,83,113,122,135,141,149,158,175,182],"air-cooled":[10,44,85],"condensers":[11,23],"is":[12],"limited":[14],"installation":[15],"space,":[16],"which":[17],"necessitates":[18],"use":[20],"compact":[22],"that":[24,165],"are":[25,57],"often":[26],"cost-prohibitive.":[27],"To":[28],"address":[29],"this,":[30],"present":[32],"study":[33],"investigates":[34],"a":[35,39,117,131,138,145,154,194],"novel":[36],"approach:":[37],"integrating":[38],"heat-pipe":[40,167],"assembly":[41,168],"with":[42,130],"an":[43,109],"condenser":[45,69,146,192],"to":[46,203],"augment":[47],"its":[48,89],"thermal":[49,81],"performance.":[50],"In":[51],"this":[52],"configuration,":[53],"multiple":[54],"pipes":[56],"installed":[58],"within":[59],"condensing":[61],"liquid":[62],"reservoir":[63],"at":[64,108],"base":[66,177],"and":[70,91,100,116,144,212],"extended":[71],"along":[72],"outer":[74],"surface":[75],"radiator":[78],"fins.":[79],"The":[80,162],"performance":[82,174],"condenser,":[86,178],"both":[87],"conventional":[90],"modified":[92,191],"forms,":[93],"was":[94],"numerically":[95],"investigated":[96],"under":[97],"various":[98],"design":[99],"off-design":[101],"ambient":[102,110,186,207],"temperatures.":[103],"Design":[104],"conditions":[105],"were":[106],"set":[107],"air":[111],"temperature":[112,140,148,187,208],"35":[114,213],"\u00b0C":[115],"fan":[118],"mass":[119,132],"flow":[120,133],"rate":[121,134,157],"6.8":[123],"kg/s,":[124,137],"utilizing":[125],"R134a":[126],"as":[127,185,205],"refrigerant":[129],"0.34":[136],"saturation":[139],"49.7":[142],"\u00b0C,":[143,151],"outlet":[147],"43.5":[150],"resulting":[152],"rejection":[156],"approximately":[159],"59.6":[160],"kW.":[161],"results":[163],"demonstrate":[164],"significantly":[169],"enhances":[170],"although":[179],"magnitude":[181],"improvement":[183,196],"diminishes":[184],"rises.":[188],"Specifically,":[189],"exhibited":[193],"percentage":[195],"ranging":[200],"from":[201],"2.5":[202],"3.4%":[204],"varied":[209],"between":[210],"15":[211],"\u00b0C.":[214]},"counts_by_year":[],"updated_date":"2026-11-07T11:25:07.637180","created_date":"2026-11-06T00:00:00"}
