{"id":"https://openalex.org/W7225311502","doi":"https://doi.org/10.3390/pr14213574","title":"Optimized Cable-Armor Blocking for Metro Stray Current Mitigation in Urban Power Grids","display_name":"Optimized Cable-Armor Blocking for Metro Stray Current Mitigation in Urban Power Grids","publication_year":2026,"publication_date":"2026-11-05","ids":{"openalex":"https://openalex.org/W7225311502","doi":"https://doi.org/10.3390/pr14213574"},"language":"en","primary_location":{"id":"doi:10.3390/pr14213574","doi":"https://doi.org/10.3390/pr14213574","is_oa":true,"landing_page_url":"https://doi.org/10.3390/pr14213574","pdf_url":null,"source":{"id":"https://openalex.org/S4210201879","display_name":"Processes","issn_l":"2227-9717","issn":["2227-9717"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","poland-70","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Processes","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://doi.org/10.3390/pr14213574","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5044548968","display_name":"Shu Zhang","orcid":"https://orcid.org/0000-0002-5739-5758","observed_orcids":["https://orcid.org/0000-0002-5739-5758"]},"institutions":[{"id":"https://openalex.org/I24185976","display_name":"Sichuan University","ror":"https://ror.org/011ashp19","country_code":"CN","type":"education","lineage":["https://openalex.org/I24185976"]},{"id":"https://openalex.org/I74872605","display_name":"China Southern Power Grid (China)","ror":"https://ror.org/03hkh9419","country_code":"CN","type":"company","lineage":["https://openalex.org/I74872605"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Shu Zhang","raw_affiliation_strings":["School of Electrical Engineering, Sichuan University, Chengdu 610065, China","Shenzhen Power Supply Bureau Co., Ltd., China Southern Power Grid, Shenzhen 518000, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Electrical Engineering, Sichuan University, Chengdu 610065, China","institution_ids":["https://openalex.org/I24185976"]},{"raw_affiliation_string":"Shenzhen Power Supply Bureau Co., Ltd., China Southern Power Grid, Shenzhen 518000, China","institution_ids":["https://openalex.org/I74872605"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5143680481","display_name":"Shengbao Zhang","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I24185976","display_name":"Sichuan University","ror":"https://ror.org/011ashp19","country_code":"CN","type":"education","lineage":["https://openalex.org/I24185976"]},{"id":"https://openalex.org/I74872605","display_name":"China Southern Power Grid (China)","ror":"https://ror.org/03hkh9419","country_code":"CN","type":"company","lineage":["https://openalex.org/I74872605"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Shengbao Zhang","raw_affiliation_strings":["School of Electrical Engineering, Sichuan University, Chengdu 610065, China","Shenzhen Power Supply Bureau Co., Ltd., China Southern Power Grid, Shenzhen 518000, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Electrical Engineering, Sichuan University, Chengdu 610065, China","institution_ids":["https://openalex.org/I24185976"]},{"raw_affiliation_string":"Shenzhen Power Supply Bureau Co., Ltd., China Southern Power Grid, Shenzhen 518000, China","institution_ids":["https://openalex.org/I74872605"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5160741949","display_name":"Shixiang Wang","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I74872605","display_name":"China Southern Power Grid (China)","ror":"https://ror.org/03hkh9419","country_code":"CN","type":"company","lineage":["https://openalex.org/I74872605"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Shixiang Wang","raw_affiliation_strings":["Shenzhen Power Supply Bureau Co., Ltd., China Southern Power Grid, Shenzhen 518000, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Shenzhen Power Supply Bureau Co., Ltd., China Southern Power Grid, Shenzhen 518000, China","institution_ids":["https://openalex.org/I74872605"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5072447268","display_name":"Hong Shen","orcid":"https://orcid.org/0000-0002-2933-8932","observed_orcids":["https://orcid.org/0000-0002-2933-8932"]},"institutions":[{"id":"https://openalex.org/I74872605","display_name":"China Southern Power Grid (China)","ror":"https://ror.org/03hkh9419","country_code":"CN","type":"company","lineage":["https://openalex.org/I74872605"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Hong Shen","raw_affiliation_strings":["Shenzhen Power Supply Bureau Co., Ltd., China Southern Power Grid, Shenzhen 518000, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Shenzhen Power Supply Bureau Co., Ltd., China Southern Power Grid, Shenzhen 518000, China","institution_ids":["https://openalex.org/I74872605"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5160936820","display_name":"Kangguan Ke","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I74872605","display_name":"China Southern Power Grid (China)","ror":"https://ror.org/03hkh9419","country_code":"CN","type":"company","lineage":["https://openalex.org/I74872605"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Kangguan Ke","raw_affiliation_strings":["Shenzhen Power Supply Bureau Co., Ltd., China Southern Power Grid, Shenzhen 518000, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Shenzhen Power Supply Bureau Co., Ltd., China Southern Power Grid, Shenzhen 518000, China","institution_ids":["https://openalex.org/I74872605"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5101694508","display_name":"Chuang Wang","orcid":"https://orcid.org/0000-0002-7170-3403","observed_orcids":["https://orcid.org/0000-0002-7170-3403","https://orcid.org/0000-0002-1643-5645"]},"institutions":[{"id":"https://openalex.org/I74872605","display_name":"China Southern Power Grid (China)","ror":"https://ror.org/03hkh9419","country_code":"CN","type":"company","lineage":["https://openalex.org/I74872605"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Chuang Wang","raw_affiliation_strings":["Shenzhen Power Supply Bureau Co., Ltd., China Southern Power Grid, Shenzhen 518000, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Shenzhen Power Supply Bureau Co., Ltd., China Southern Power Grid, Shenzhen 518000, China","institution_ids":["https://openalex.org/I74872605"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5044548968"],"corresponding_institution_ids":["https://openalex.org/I24185976","https://openalex.org/I74872605"],"apc_list":{"value":2400,"currency":"CHF","value_usd":2896},"apc_paid":{"value":2400,"currency":"CHF","value_usd":2896},"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"14","issue":"21","first_page":"3574","last_page":"3574"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.7954000234603882,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.7954000234603882,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.0430000014603138,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11568","display_name":"Railway Systems and Energy Efficiency","score":0.03200000151991844,"subfield":{"id":"https://openalex.org/subfields/3313","display_name":"Transportation"},"field":{"id":"https://openalex.org/fields/33","display_name":"Social Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/dc-bias","display_name":"DC bias","score":0.628000020980835},{"id":"https://openalex.org/keywords/urban-power-grid","display_name":"urban power grid","score":0.7409999966621399},{"id":"https://openalex.org/keywords/constrained-multi-objective-optimization","display_name":"constrained multi-objective optimization","score":0.6690000295639038},{"id":"https://openalex.org/keywords/nsga-ii","display_name":"NSGA-II","score":0.9309999942779541},{"id":"https://openalex.org/keywords/transformer-saturation","display_name":"transformer saturation","score":0.675000011920929}],"concepts":[{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.6003000140190125},{"id":"https://openalex.org/C144745244","wikidata":"https://www.wikidata.org/wiki/Q4927286","display_name":"Blocking (statistics)","level":2,"score":0.5482000112533569},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5342000126838684},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5321999788284302},{"id":"https://openalex.org/C186697258","wikidata":"https://www.wikidata.org/wiki/Q361842","display_name":"Traction power network","level":3,"score":0.4964999854564667},{"id":"https://openalex.org/C148237231","wikidata":"https://www.wikidata.org/wiki/Q657444","display_name":"Stray voltage","level":3,"score":0.4878999888896942},{"id":"https://openalex.org/C2777772068","wikidata":"https://www.wikidata.org/wiki/Q1939150","display_name":"Power cable","level":3,"score":0.44600000977516174},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4083999991416931},{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.3894999921321869},{"id":"https://openalex.org/C133770746","wikidata":"https://www.wikidata.org/wiki/Q856535","display_name":"Current transformer","level":4,"score":0.36320000886917114},{"id":"https://openalex.org/C145528699","wikidata":"https://www.wikidata.org/wiki/Q803616","display_name":"Traction substation","level":4,"score":0.3560999929904938},{"id":"https://openalex.org/C180850520","wikidata":"https://www.wikidata.org/wiki/Q2166404","display_name":"Isolation transformer","level":4,"score":0.34790000319480896},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3418000042438507},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3379000127315521},{"id":"https://openalex.org/C202374169","wikidata":"https://www.wikidata.org/wiki/Q124291","display_name":"Electrical conductor","level":2,"score":0.33090001344680786},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.32260000705718994},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.32010000944137573},{"id":"https://openalex.org/C7943809","wikidata":"https://www.wikidata.org/wiki/Q1977384","display_name":"Ampacity","level":3,"score":0.27619999647140503},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.2759000062942505},{"id":"https://openalex.org/C2983254600","wikidata":"https://www.wikidata.org/wiki/Q1096907","display_name":"Power grid","level":3,"score":0.2754000127315521},{"id":"https://openalex.org/C105339364","wikidata":"https://www.wikidata.org/wiki/Q2297740","display_name":"Software deployment","level":2,"score":0.27459999918937683},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.2581000030040741},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.2572999894618988}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.3390/pr14213574","doi":"https://doi.org/10.3390/pr14213574","is_oa":true,"landing_page_url":"https://doi.org/10.3390/pr14213574","pdf_url":null,"source":{"id":"https://openalex.org/S4210201879","display_name":"Processes","issn_l":"2227-9717","issn":["2227-9717"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","poland-70","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Processes","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.3390/pr14213574","doi":"https://doi.org/10.3390/pr14213574","is_oa":true,"landing_page_url":"https://doi.org/10.3390/pr14213574","pdf_url":null,"source":{"id":"https://openalex.org/S4210201879","display_name":"Processes","issn_l":"2227-9717","issn":["2227-9717"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","poland-70","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Processes","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","score":1.0,"display_name":"Industry, innovation and infrastructure"},{"id":"https://metadata.un.org/sdg/11","score":0.7646999955177307,"display_name":"Sustainable cities and communities"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":19,"referenced_works":["https://openalex.org/W1975599641","https://openalex.org/W2126105956","https://openalex.org/W2901376795","https://openalex.org/W2944971633","https://openalex.org/W3006741154","https://openalex.org/W3012010401","https://openalex.org/W3096918029","https://openalex.org/W3120990338","https://openalex.org/W3194376410","https://openalex.org/W4210579475","https://openalex.org/W4282968086","https://openalex.org/W4285203377","https://openalex.org/W4292794778","https://openalex.org/W4310086112","https://openalex.org/W4320727864","https://openalex.org/W4401168537","https://openalex.org/W4407761954","https://openalex.org/W4412199274","https://openalex.org/W7126240522"],"related_works":["https://openalex.org/W4399962769","https://openalex.org/W4408146622","https://openalex.org/W4320727864","https://openalex.org/W2945850782","https://openalex.org/W4396767108","https://openalex.org/W7220471567","https://openalex.org/W4380030748","https://openalex.org/W7166020882","https://openalex.org/W7213774888","https://openalex.org/W4400643110"],"abstract_inverted_index":{"Metro":[0],"DC":[1,33],"traction":[2],"systems":[3],"cause":[4,37],"return":[5],"current":[6,18,60,75,97,125,143],"to":[7,76,119,137,159],"leak":[8],"from":[9],"the":[10,14,59,68,140,145,161,188,197,208],"running":[11],"rails":[12],"into":[13,20],"earth.":[15],"This":[16],"stray":[17,74,96],"intrudes":[19],"urban":[21,99],"power":[22,100],"grids":[23,101],"through":[24],"metallic":[25],"paths":[26,218],"such":[27],"as":[28],"cable":[29,104,114,216],"armors,":[30],"driving":[31],"transformer":[32,54,70,121,193],"bias":[34],"that":[35,219],"can":[36],"core":[38],"saturation,":[39],"increased":[40],"losses,":[41],"vibration,":[42],"and":[43,133,144,150,172,232],"accelerated":[44],"insulation":[45],"aging.":[46],"Conventional":[47],"mitigation":[48,92],"measures":[49],"install":[50],"blocking":[51,116,148,206,236],"devices":[52,201],"at":[53],"neutral":[55],"points":[56],"only":[57],"after":[58],"limit":[61],"is":[62,117,131,157],"exceeded;":[63],"this":[64,85,87],"single-point":[65,204],"treatment":[66],"protects":[67],"treated":[69],"but":[71],"may":[72],"redistribute":[73],"neighboring":[77],"substations,":[78],"requiring":[79],"repeated":[80,169],"device":[81],"installations.":[82],"To":[83],"overcome":[84],"limitation,":[86],"paper":[88],"proposes":[89],"a":[90,182],"coordinated":[91,230],"method":[93,190],"for":[94],"metro":[95],"in":[98,181],"based":[102],"on":[103],"armor":[105,115,217],"path":[106],"blocking.":[107],"An":[108],"equivalent":[109],"nodal":[110],"admittance":[111],"model":[112,130],"incorporating":[113],"established":[118],"calculate":[120],"neutral-point":[122,142,194,205],"currents":[123,195],"following":[124],"redistribution.":[126],"A":[127],"constrained":[128],"optimization":[129,170],"formulated":[132],"solved":[134],"by":[135],"NSGA-II":[136],"jointly":[138],"minimize":[139],"maximum":[141],"number":[146],"of":[147,154,164,235],"devices,":[149],"Monte":[151],"Carlo":[152],"sampling":[153],"train":[155,227],"positions":[156],"used":[158],"determine":[160],"selection":[162],"frequency":[163],"each":[165],"candidate":[166],"location":[167],"across":[168,225],"outcomes":[171],"identify":[173],"priority":[174,224],"installation":[175],"locations.":[176],"Simulation":[177],"results":[178],"show":[179],"that,":[180],"practical":[183],"coupled":[184],"metro\u2013power":[185],"grid":[186],"case,":[187],"proposed":[189],"effectively":[191],"suppresses":[192],"throughout":[196],"network":[198],"with":[199],"fewer":[200],"than":[202],"conventional":[203],"under":[207],"examined":[209],"operating":[210],"conditions.":[211],"Multi-scenario":[212],"analysis":[213],"further":[214],"identifies":[215],"consistently":[220],"have":[221],"high":[222],"placement":[223],"different":[226],"positions,":[228],"supporting":[229],"siting":[231],"phased":[233],"deployment":[234],"devices.":[237]},"counts_by_year":[],"updated_date":"2026-11-07T11:25:07.637180","created_date":"2026-11-06T00:00:00"}