{"id":"https://openalex.org/W7225229489","doi":"https://doi.org/10.1109/cpem68396.2026.11756461","title":"Multi-Method Measurement and Deviation Analysis of the Calibration Factor of an Attenuator Assembly","display_name":"Multi-Method Measurement and Deviation Analysis of the Calibration Factor of an Attenuator Assembly","publication_year":2026,"publication_date":"2026-09-01","ids":{"openalex":"https://openalex.org/W7225229489","doi":"https://doi.org/10.1109/cpem68396.2026.11756461"},"language":"en","primary_location":{"id":"doi:10.1109/cpem68396.2026.11756461","doi":"https://doi.org/10.1109/cpem68396.2026.11756461","is_oa":true,"landing_page_url":"https://doi.org/10.1109/cpem68396.2026.11756461","pdf_url":null,"source":{"id":"https://openalex.org/S4306418090","display_name":"Conference on Precision Electromagnetic Measurements","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2026 Conference on Precision Electromagnetic Measurements (CPEM)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"hybrid","oa_url":"https://doi.org/10.1109/cpem68396.2026.11756461","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101358952","display_name":"Yi Wei","orcid":"https://orcid.org/0009-0005-4430-8810","observed_orcids":["https://orcid.org/0009-0005-4430-8810"]},"institutions":[{"id":"https://openalex.org/I55538621","display_name":"China Jiliang University","ror":"https://ror.org/05v1y0t93","country_code":"CN","type":"education","lineage":["https://openalex.org/I55538621"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yi Wei","raw_affiliation_strings":["China Jiliang University"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"China Jiliang University","institution_ids":["https://openalex.org/I55538621"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5018406581","display_name":"Jinwen Liu","orcid":"https://orcid.org/0000-0002-6511-3730","observed_orcids":["https://orcid.org/0000-0002-6511-3730"]},"institutions":[{"id":"https://openalex.org/I4210162136","display_name":"National Institute of Metrology","ror":"https://ror.org/05dw0p167","country_code":"CN","type":"other","lineage":["https://openalex.org/I4210162136"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jinwen Liu","raw_affiliation_strings":["National Institute of Metrology"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Institute of Metrology","institution_ids":["https://openalex.org/I4210162136"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5071589064","display_name":"Xiaohai Cui","orcid":"https://orcid.org/0000-0001-9202-5800","observed_orcids":["https://orcid.org/0000-0001-9202-5800"]},"institutions":[{"id":"https://openalex.org/I4210162136","display_name":"National Institute of Metrology","ror":"https://ror.org/05dw0p167","country_code":"CN","type":"other","lineage":["https://openalex.org/I4210162136"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xiaohai Cui","raw_affiliation_strings":["National Institute of Metrology"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Institute of Metrology","institution_ids":["https://openalex.org/I4210162136"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5110452290","display_name":"Wenze Yuan","orcid":"https://orcid.org/0000-0001-5913-7587","observed_orcids":["https://orcid.org/0000-0001-5913-7587"]},"institutions":[{"id":"https://openalex.org/I4210162136","display_name":"National Institute of Metrology","ror":"https://ror.org/05dw0p167","country_code":"CN","type":"other","lineage":["https://openalex.org/I4210162136"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Wenze Yuan","raw_affiliation_strings":["National Institute of Metrology"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Institute of Metrology","institution_ids":["https://openalex.org/I4210162136"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5135859967","display_name":"Xiangjun Li","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I55538621","display_name":"China Jiliang University","ror":"https://ror.org/05v1y0t93","country_code":"CN","type":"education","lineage":["https://openalex.org/I55538621"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xiangjun Li","raw_affiliation_strings":["China Jiliang University"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"China Jiliang University","institution_ids":["https://openalex.org/I55538621"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"2"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11607","display_name":"Microwave and Dielectric Measurement Techniques","score":0.5175999999046326,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11607","display_name":"Microwave and Dielectric Measurement Techniques","score":0.5175999999046326,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.3345000147819519,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12019","display_name":"Calibration and Measurement Techniques","score":0.08309999853372574,"subfield":{"id":"https://openalex.org/subfields/2202","display_name":"Aerospace Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microwave-power-measurement","display_name":"microwave power measurement","score":0.5690000057220459},{"id":"https://openalex.org/keywords/calibration-factor","display_name":"calibration factor","score":0.9570000171661377},{"id":"https://openalex.org/keywords/traceability","display_name":"traceability","score":0.6610000133514404},{"id":"https://openalex.org/keywords/repeatability","display_name":"repeatability","score":0.699999988079071},{"id":"https://openalex.org/keywords/s-parameters","display_name":"S-parameters","score":0.5189999938011169},{"id":"https://openalex.org/keywords/extrapolation","display_name":"extrapolation","score":0.8190000057220459},{"id":"https://openalex.org/keywords/error-source-analysis","display_name":"error source analysis","score":0.5899999737739563},{"id":"https://openalex.org/keywords/consistency-evaluation","display_name":"consistency evaluation","score":0.6610000133514404}],"concepts":[{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.6665999889373779},{"id":"https://openalex.org/C174847166","wikidata":"https://www.wikidata.org/wiki/Q1269728","display_name":"Attenuator (electronics)","level":3,"score":0.4325000047683716},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.42419999837875366},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.34850001335144043},{"id":"https://openalex.org/C22679943","wikidata":"https://www.wikidata.org/wiki/Q159375","display_name":"Standard deviation","level":2,"score":0.32580000162124634},{"id":"https://openalex.org/C19619285","wikidata":"https://www.wikidata.org/wiki/Q196372","display_name":"Observational error","level":2,"score":0.3061000108718872},{"id":"https://openalex.org/C62646347","wikidata":"https://www.wikidata.org/wiki/Q2041172","display_name":"Measuring instrument","level":2,"score":0.26409998536109924},{"id":"https://openalex.org/C2986587452","wikidata":"https://www.wikidata.org/wiki/Q938438","display_name":"Statistical analysis","level":2,"score":0.25519999861717224},{"id":"https://openalex.org/C3018824978","wikidata":"https://www.wikidata.org/wiki/Q2894891","display_name":"Error analysis","level":2,"score":0.2506999969482422},{"id":"https://openalex.org/C175291020","wikidata":"https://www.wikidata.org/wiki/Q1156822","display_name":"Offset (computer science)","level":2,"score":0.25060001015663147}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/cpem68396.2026.11756461","doi":"https://doi.org/10.1109/cpem68396.2026.11756461","is_oa":true,"landing_page_url":"https://doi.org/10.1109/cpem68396.2026.11756461","pdf_url":null,"source":{"id":"https://openalex.org/S4306418090","display_name":"Conference on Precision Electromagnetic Measurements","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2026 Conference on Precision Electromagnetic Measurements (CPEM)","raw_type":"proceedings-article"}],"best_oa_location":{"id":"doi:10.1109/cpem68396.2026.11756461","doi":"https://doi.org/10.1109/cpem68396.2026.11756461","is_oa":true,"landing_page_url":"https://doi.org/10.1109/cpem68396.2026.11756461","pdf_url":null,"source":{"id":"https://openalex.org/S4306418090","display_name":"Conference on Precision Electromagnetic Measurements","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2026 Conference on Precision Electromagnetic Measurements (CPEM)","raw_type":"proceedings-article"},"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":1,"referenced_works":["https://openalex.org/W2996700105"],"related_works":["https://openalex.org/W2324272726","https://openalex.org/W4255472975","https://openalex.org/W2071612872","https://openalex.org/W2052765060","https://openalex.org/W7064628700","https://openalex.org/W2069771883","https://openalex.org/W2024727971","https://openalex.org/W2083524304","https://openalex.org/W2074788937","https://openalex.org/W2063499595"],"abstract_inverted_index":{"Medium-power":[0],"microwave":[1,24],"traceability":[2],"requires":[3],"a":[4,19,23,66,72],"balance":[5],"between":[6],"measurement":[7,14,29],"accuracy":[8],"and":[9,44,65,77,92],"practical":[10],"implementation.":[11],"A":[12],"power":[13],"assembly":[15],"formed":[16],"by":[17,38],"cascading":[18],"medium-power":[20],"attenuator":[21,39],"with":[22],"low-power":[25],"sensor":[26],"extends":[27],"the":[28,62,79],"range,":[30],"but":[31],"its":[32],"calibration":[33,90],"factor,":[34],"KCC,":[35],"is":[36],"affected":[37],"transmission":[40],"characteristics,":[41],"port":[42],"mismatch,":[43],"connection":[45],"repeatability,":[46],"leading":[47],"to":[48],"discrepancies":[49],"among":[50],"different":[51],"determination":[52],"methods.":[53],"This":[54],"paper":[55],"compares":[56],"three":[57],"approaches\u2014the":[58],"direct":[59],"comparison":[60],"method,":[61,64],"extrapolation":[63],"scattering":[67],"parameter":[68],"based":[69],"method":[70],"using":[71],"three-port":[73],"transfer":[74],"standard":[75],"\u2014":[76],"analyzes":[78],"main":[80],"error":[81],"sources":[82],"responsible":[83],"for":[84,89],"their":[85],"differences,":[86],"providing":[87],"guidance":[88],"implementation":[91],"consistency":[93],"evaluation.":[94]},"counts_by_year":[],"updated_date":"2026-11-10T11:39:43.021295","created_date":"2026-11-05T00:00:00"}
