{"id":"https://openalex.org/W7225177664","doi":"https://doi.org/10.5281/zenodo.23908084","title":"AI Based predictive Maintenance System for Industrial Equipment","display_name":"AI Based predictive Maintenance System for Industrial Equipment","publication_year":2026,"publication_date":"2026-11-03","ids":{"openalex":"https://openalex.org/W7225177664","doi":"https://doi.org/10.5281/zenodo.23908084"},"language":"en","primary_location":{"id":"doi:10.5281/zenodo.23908084","doi":"https://doi.org/10.5281/zenodo.23908084","is_oa":true,"landing_page_url":"https://doi.org/10.5281/zenodo.23908084","pdf_url":null,"source":{"id":"https://openalex.org/S4306400562","display_name":"Zenodo (CERN European Organization for Nuclear Research)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I67311998","host_organization_name":"European Organization for Nuclear Research","host_organization_lineage":["https://openalex.org/I67311998"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"JournalArticle"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["datacite"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://doi.org/10.5281/zenodo.23908084","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5160558426","display_name":"Krishna Rumale","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Krishna Rumale","raw_affiliation_strings":["School of Engineering and Technology, MGM University, Chhatrapati Sambhajinagar, MS, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Engineering and Technology, MGM University, Chhatrapati Sambhajinagar, MS, India","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5160515066","display_name":"Rushikesh Waghmare","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Rushikesh Waghmare","raw_affiliation_strings":["School of Engineering and Technology, MGM University, Chhatrapati Sambhajinagar, MS, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Engineering and Technology, MGM University, Chhatrapati Sambhajinagar, MS, India","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5071882119","display_name":"Pranav Kulkarni","orcid":"https://orcid.org/0000-0002-3212-4070","observed_orcids":["https://orcid.org/0000-0002-3212-4070"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Pranav Kulkarni","raw_affiliation_strings":["School of Engineering and Technology, MGM University, Chhatrapati Sambhajinagar, MS, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Engineering and Technology, MGM University, Chhatrapati Sambhajinagar, MS, India","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5160436273","display_name":"Pankaj Borude","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Pankaj Borude","raw_affiliation_strings":["School of Engineering and Technology, MGM University, Chhatrapati Sambhajinagar, MS, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Engineering and Technology, MGM University, Chhatrapati Sambhajinagar, MS, India","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5035282447","display_name":"Snehal Ratnaparkhi","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Snehal Ratnaparkhi","raw_affiliation_strings":["School of Engineering and Technology, MGM University, Chhatrapati Sambhajinagar, MS, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Engineering and Technology, MGM University, Chhatrapati Sambhajinagar, MS, India","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5035350498","display_name":"Madhuri Kawarkhe","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Dr. Madhuri Kawarkhe","raw_affiliation_strings":["School of Engineering and Technology, MGM University, Chhatrapati Sambhajinagar, MS, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Engineering and Technology, MGM University, Chhatrapati Sambhajinagar, MS, India","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.78671335,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.7979000210762024,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.7979000210762024,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.1412000060081482,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.0421999990940094,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/predictive-maintenance","display_name":"predictive maintenance","score":1.0},{"id":"https://openalex.org/keywords/iot-sensor-data","display_name":"IoT sensor data","score":0.8299999833106995},{"id":"https://openalex.org/keywords/lstm","display_name":"LSTM","score":0.7580000162124634},{"id":"https://openalex.org/keywords/xgboost","display_name":"XGBoost","score":0.9980000257492065},{"id":"https://openalex.org/keywords/class-imbalance","display_name":"class imbalance","score":0.6370000243186951},{"id":"https://openalex.org/keywords/smote-oversampling","display_name":"SMOTE oversampling","score":0.9800000190734863},{"id":"https://openalex.org/keywords/anomaly-detection","display_name":"anomaly detection","score":0.6320000290870667},{"id":"https://openalex.org/keywords/unplanned-downtime-reduction","display_name":"unplanned downtime reduction","score":0.9160000085830688},{"id":"https://openalex.org/keywords/maintenance-cost-reduction","display_name":"maintenance cost reduction","score":0.9710000157356262},{"id":"https://openalex.org/keywords/manufacturing-industry","display_name":"manufacturing industry","score":0.6000000238418579}],"concepts":[{"id":"https://openalex.org/C180591934","wikidata":"https://www.wikidata.org/wiki/Q1253369","display_name":"Downtime","level":2,"score":0.8471999764442444},{"id":"https://openalex.org/C70452415","wikidata":"https://www.wikidata.org/wiki/Q3182448","display_name":"Predictive maintenance","level":2,"score":0.8172000050544739},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.6316999793052673},{"id":"https://openalex.org/C41661131","wikidata":"https://www.wikidata.org/wiki/Q220764","display_name":"Interrupt","level":3,"score":0.6067000031471252},{"id":"https://openalex.org/C2984282874","wikidata":"https://www.wikidata.org/wiki/Q10952243","display_name":"Industrial equipment","level":2,"score":0.6014000177383423},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.49309998750686646},{"id":"https://openalex.org/C24090081","wikidata":"https://www.wikidata.org/wiki/Q1043452","display_name":"Preventive maintenance","level":2,"score":0.46639999747276306},{"id":"https://openalex.org/C12267149","wikidata":"https://www.wikidata.org/wiki/Q282453","display_name":"Support vector machine","level":2,"score":0.390500009059906},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3698999881744385},{"id":"https://openalex.org/C2781106871","wikidata":"https://www.wikidata.org/wiki/Q1029015","display_name":"Overall equipment effectiveness","level":3,"score":0.3635999858379364},{"id":"https://openalex.org/C2778814095","wikidata":"https://www.wikidata.org/wiki/Q6736790","display_name":"Maintenance actions","level":2,"score":0.3564000129699707},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.352400004863739},{"id":"https://openalex.org/C29825287","wikidata":"https://www.wikidata.org/wiki/Q1427940","display_name":"Warning system","level":2,"score":0.3465999960899353},{"id":"https://openalex.org/C2775846686","wikidata":"https://www.wikidata.org/wiki/Q643012","display_name":"Condition monitoring","level":2,"score":0.33709999918937683},{"id":"https://openalex.org/C141417316","wikidata":"https://www.wikidata.org/wiki/Q3278390","display_name":"Proactive maintenance","level":3,"score":0.33640000224113464},{"id":"https://openalex.org/C129529059","wikidata":"https://www.wikidata.org/wiki/Q2291518","display_name":"Corrective maintenance","level":3,"score":0.326200008392334},{"id":"https://openalex.org/C23725684","wikidata":"https://www.wikidata.org/wiki/Q616377","display_name":"Maintenance engineering","level":2,"score":0.32580000162124634},{"id":"https://openalex.org/C147494362","wikidata":"https://www.wikidata.org/wiki/Q2078905","display_name":"Troubleshooting","level":2,"score":0.3240000009536743},{"id":"https://openalex.org/C197323446","wikidata":"https://www.wikidata.org/wiki/Q331222","display_name":"Oversampling","level":3,"score":0.32339999079704285},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.3199999928474426},{"id":"https://openalex.org/C4402595","wikidata":"https://www.wikidata.org/wiki/Q1043452","display_name":"Planned maintenance","level":2,"score":0.31929999589920044},{"id":"https://openalex.org/C2777212361","wikidata":"https://www.wikidata.org/wiki/Q5127848","display_name":"Class (philosophy)","level":2,"score":0.31540000438690186},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.3149000108242035},{"id":"https://openalex.org/C81860439","wikidata":"https://www.wikidata.org/wiki/Q251212","display_name":"Internet of Things","level":2,"score":0.2969000041484833},{"id":"https://openalex.org/C42259789","wikidata":"https://www.wikidata.org/wiki/Q1392940","display_name":"Fail-safe","level":2,"score":0.29670000076293945},{"id":"https://openalex.org/C119857082","wikidata":"https://www.wikidata.org/wiki/Q2539","display_name":"Machine learning","level":1,"score":0.28279998898506165},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.28139999508857727},{"id":"https://openalex.org/C2983725658","wikidata":"https://www.wikidata.org/wiki/Q7705768","display_name":"Test equipment","level":2,"score":0.2809000015258789},{"id":"https://openalex.org/C158066952","wikidata":"https://www.wikidata.org/wiki/Q960289","display_name":"Work order","level":2,"score":0.2784000039100647},{"id":"https://openalex.org/C2776907094","wikidata":"https://www.wikidata.org/wiki/Q1043452","display_name":"Condition-based maintenance","level":2,"score":0.27390000224113464},{"id":"https://openalex.org/C163164238","wikidata":"https://www.wikidata.org/wiki/Q2737027","display_name":"Failure rate","level":2,"score":0.259799987077713},{"id":"https://openalex.org/C175700187","wikidata":"https://www.wikidata.org/wiki/Q187939","display_name":"Manufacturing","level":2,"score":0.2597000002861023},{"id":"https://openalex.org/C2776544517","wikidata":"https://www.wikidata.org/wiki/Q189447","display_name":"Unexpected events","level":2,"score":0.251800000667572}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.5281/zenodo.23908084","doi":"https://doi.org/10.5281/zenodo.23908084","is_oa":true,"landing_page_url":"https://doi.org/10.5281/zenodo.23908084","pdf_url":null,"source":{"id":"https://openalex.org/S4306400562","display_name":"Zenodo (CERN European Organization for Nuclear Research)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I67311998","host_organization_name":"European Organization for Nuclear Research","host_organization_lineage":["https://openalex.org/I67311998"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"JournalArticle"},{"id":"doi:10.5281/zenodo.23908085","doi":"https://doi.org/10.5281/zenodo.23908085","is_oa":true,"landing_page_url":"https://doi.org/10.5281/zenodo.23908085","pdf_url":null,"source":{"id":"https://openalex.org/S4306400562","display_name":"Zenodo (CERN European Organization for Nuclear Research)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I67311998","host_organization_name":"European Organization for Nuclear Research","host_organization_lineage":["https://openalex.org/I67311998"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"JournalArticle"}],"best_oa_location":{"id":"doi:10.5281/zenodo.23908084","doi":"https://doi.org/10.5281/zenodo.23908084","is_oa":true,"landing_page_url":"https://doi.org/10.5281/zenodo.23908084","pdf_url":null,"source":{"id":"https://openalex.org/S4306400562","display_name":"Zenodo (CERN European Organization for Nuclear Research)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I67311998","host_organization_name":"European Organization for Nuclear Research","host_organization_lineage":["https://openalex.org/I67311998"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"JournalArticle"},"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","score":1.0,"id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W7165028785","https://openalex.org/W7216720611","https://openalex.org/W7154058572","https://openalex.org/W7162402445","https://openalex.org/W7118556438","https://openalex.org/W7160966335","https://openalex.org/W4410129763","https://openalex.org/W7225185299","https://openalex.org/W7139987336","https://openalex.org/W4413084002"],"abstract_inverted_index":{"Unexpected":[0],"equipment":[1,36],"failures":[2],"can":[3,170],"interrupt":[4],"production,":[5],"increase":[6],"maintenance":[7,22,148,158,172],"expenses,":[8],"and":[9,86,124,177],"create":[10],"safety":[11],"concerns":[12],"in":[13,55,69],"manufacturing":[14,114],"environments.":[15],"This":[16],"paper":[17],"describes":[18],"an":[19,61,130],"AI-based":[20],"predictive":[21],"system,":[23],"called":[24],"PrimeAI,":[25],"that":[26,64,163],"uses":[27],"live":[28],"IoT":[29,165],"sensor":[30,56,71,104],"information":[31,105,176],"to":[32,91],"identify":[33],"signs":[34],"of":[35,95,133],"failure":[37,40,74],"before":[38,136],"the":[39,93,156],"actually":[41],"happens.":[42],"The":[43,98,127],"system":[44,99],"combines":[45],"a":[46,137],"Long":[47],"Short-Term":[48],"Memory":[49],"(LSTM)":[50],"network,":[51],"which":[52],"learns":[53],"changes":[54],"readings":[57],"over":[58],"time,":[59],"with":[60,155,167],"XGBoost":[62],"model":[63,128],"looks":[65],"for":[66],"abnormal":[67],"patterns":[68],"engineered":[70],"features.":[72],"Because":[73],"cases":[75],"are":[76,89],"much":[77],"less":[78],"common":[79],"than":[80],"normal":[81],"operating":[82],"cases,":[83],"SMOTE":[84],"oversampling":[85],"class-weighted":[87],"training":[88],"used":[90],"reduce":[92],"effect":[94],"class":[96],"imbalance.":[97],"was":[100],"evaluated":[101],"using":[102],"streaming":[103],"collected":[106],"from":[107],"50":[108],"industrial":[109],"machines":[110],"located":[111],"across":[112],"three":[113],"facilities.":[115],"On":[116],"unseen":[117],"test":[118],"data,":[119],"PrimeAI":[120],"achieved":[121],"94.2%":[122],"precision":[123],"91.7%":[125],"recall.":[126],"provided":[129],"average":[131],"warning":[132],"14.3":[134],"days":[135],"documented":[138],"failure.":[139],"During":[140],"deployment,":[141],"unplanned":[142],"downtime":[143],"decreased":[144,150],"by":[145,151],"68%,":[146],"while":[147],"costs":[149],"42%":[152],"when":[153],"compared":[154],"baseline":[157],"approach.":[159],"These":[160],"results":[161],"indicate":[162],"combining":[164],"monitoring":[166],"machine":[168],"learning":[169],"give":[171],"teams":[173],"useful":[174],"advance":[175],"support":[178],"better":[179],"planning.":[180]},"counts_by_year":[],"updated_date":"2026-11-05T12:25:35.769452","created_date":"2026-11-04T00:00:00"}
