{"id":"https://openalex.org/W7224469071","doi":"https://doi.org/10.1109/tste.2026.3748040","title":"Transient Voltage Immunity of Grid-Following Converters: Assessment and Suppression of Post-Fault Temporary Overvoltage","display_name":"Transient Voltage Immunity of Grid-Following Converters: Assessment and Suppression of Post-Fault Temporary Overvoltage","alternate_titles":[],"publication_year":2026,"publication_date":"2026-01-01","ids":{"openalex":"https://openalex.org/W7224469071","doi":"https://doi.org/10.1109/tste.2026.3748040"},"language":"en","primary_location":{"id":"doi:10.1109/tste.2026.3748040","doi":"https://doi.org/10.1109/tste.2026.3748040","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tste.2026.3748040","pdf_url":null,"source":{"id":"https://openalex.org/S201762130","display_name":"IEEE Transactions on Sustainable Energy","issn_l":"1949-3029","issn":["1949-3029","1949-3037"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-b","jufo-2","norway-1","poland-200","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Sustainable Energy","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W7224469071"],"child_works_count":0,"pull_notice_works":[],"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://spiral.imperial.ac.uk/bitstreams/e6124bf3-d7e3-462d-905a-09a16d6b9e60/download","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5038220936","display_name":"Xinyu Liu","type":null,"orcid":"https://orcid.org/0000-0001-5262-7647","observed_orcids":["https://orcid.org/0000-0001-5262-7647"]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I153473198","display_name":"North China Electric Power University","ror":"https://ror.org/04qr5t414","country_code":"CN","type":"education","lineage":["https://openalex.org/I153473198"]}],"countries":["CN"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Xinyu Liu","raw_affiliation_strings":["North China Electric Power University, Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"North China Electric Power University, Beijing, China","institution_ids":["https://openalex.org/I153473198"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5129044994","display_name":"Zhipeng Bao","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I153473198","display_name":"North China Electric Power University","ror":"https://ror.org/04qr5t414","country_code":"CN","type":"education","lineage":["https://openalex.org/I153473198"]}],"countries":["CN"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Zhipeng Bao","raw_affiliation_strings":["North China Electric Power University, Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"North China Electric Power University, Beijing, China","institution_ids":["https://openalex.org/I153473198"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5077234408","display_name":"Tianshu Bi","type":null,"orcid":"https://orcid.org/0000-0002-3555-9045","observed_orcids":["https://orcid.org/0000-0002-3555-9045"]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I153473198","display_name":"North China Electric Power University","ror":"https://ror.org/04qr5t414","country_code":"CN","type":"education","lineage":["https://openalex.org/I153473198"]}],"countries":["CN"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Tianshu Bi","raw_affiliation_strings":["North China Electric Power University, Beijing, China"],"raw_orcid":"https://orcid.org/0000-0002-3555-9045","affiliations":[{"raw_affiliation_string":"North China Electric Power University, Beijing, China","institution_ids":["https://openalex.org/I153473198"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5037203563","display_name":"Bikash Chandra Pal","type":null,"orcid":"https://orcid.org/0000-0002-9655-239X","observed_orcids":["https://orcid.org/0000-0002-9655-239X"]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I47508984","display_name":"Imperial College London","ror":"https://ror.org/041kmwe10","country_code":"GB","type":"education","lineage":["https://openalex.org/I47508984"]}],"countries":["GB"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Bikash C. Pal","raw_affiliation_strings":["Imperial College, London, U.K"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Imperial College, London, U.K","institution_ids":["https://openalex.org/I47508984"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5114377957","display_name":"Hao Liu","type":null,"orcid":"https://orcid.org/0000-0002-9569-3430","observed_orcids":["https://orcid.org/0000-0002-9569-3430"]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I153473198","display_name":"North China Electric Power University","ror":"https://ror.org/04qr5t414","country_code":"CN","type":"education","lineage":["https://openalex.org/I153473198"]}],"countries":["CN"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Hao Liu","raw_affiliation_strings":["North China Electric Power University, Beijing, China"],"raw_orcid":"https://orcid.org/0000-0002-9569-3430","affiliations":[{"raw_affiliation_string":"North China Electric Power University, Beijing, China","institution_ids":["https://openalex.org/I153473198"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":2645,"currency":"USD","value_usd":2645},"apc_paid":null,"fwci":0.0,"has_fulltext":true,"cited_by_count":0,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"14"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9653000235557556,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9653000235557556,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.01269999984651804,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.004600000102072954,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/grid-following-inverters","display_name":"grid-following inverters","score":0.9959999918937683},{"id":"https://openalex.org/keywords/singular-value-analysis","display_name":"singular value analysis","score":0.8809999823570251},{"id":"https://openalex.org/keywords/equivalent-impedance-model","display_name":"equivalent impedance model","score":0.7829999923706055},{"id":"https://openalex.org/keywords/current-tracking","display_name":"current tracking","score":0.4970000088214874},{"id":"https://openalex.org/keywords/small-signal-stability","display_name":"small-signal stability","score":0.9800000190734863},{"id":"https://openalex.org/keywords/renewable-power-plants","display_name":"renewable power plants","score":0.824999988079071}],"concepts":[{"id":"https://openalex.org/C15703209","wikidata":"https://www.wikidata.org/wiki/Q333883","display_name":"Overvoltage","level":3,"score":0.8299999833106995},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.6237999796867371},{"id":"https://openalex.org/C2989121073","wikidata":"https://www.wikidata.org/wiki/Q1309019","display_name":"Transient analysis","level":3,"score":0.5340999960899353},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.5091000199317932},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5047000050544739},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.3828999996185303},{"id":"https://openalex.org/C14915586","wikidata":"https://www.wikidata.org/wiki/Q1653998","display_name":"Transient voltage suppressor","level":3,"score":0.3700999915599823},{"id":"https://openalex.org/C2984221369","wikidata":"https://www.wikidata.org/wiki/Q422584","display_name":"Electric breakdown","level":3,"score":0.36419999599456787},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3573000133037567},{"id":"https://openalex.org/C121922863","wikidata":"https://www.wikidata.org/wiki/Q180805","display_name":"Thyristor","level":3,"score":0.33820000290870667},{"id":"https://openalex.org/C101382669","wikidata":"https://www.wikidata.org/wiki/Q1616769","display_name":"Ferroresonance in electricity networks","level":4,"score":0.3327000141143799},{"id":"https://openalex.org/C85761212","wikidata":"https://www.wikidata.org/wiki/Q1974593","display_name":"Transient response","level":2,"score":0.3043000102043152},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.2944999933242798},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.2863999903202057},{"id":"https://openalex.org/C47949032","wikidata":"https://www.wikidata.org/wiki/Q663542","display_name":"Overcurrent","level":3,"score":0.28029999136924744},{"id":"https://openalex.org/C2779341262","wikidata":"https://www.wikidata.org/wiki/Q182581","display_name":"Immunity","level":3,"score":0.26409998536109924},{"id":"https://openalex.org/C2776099285","wikidata":"https://www.wikidata.org/wiki/Q244404","display_name":"Electric shock","level":2,"score":0.2581999897956848},{"id":"https://openalex.org/C2779679103","wikidata":"https://www.wikidata.org/wiki/Q5251805","display_name":"Degradation (telecommunications)","level":2,"score":0.25600001215934753},{"id":"https://openalex.org/C38361682","wikidata":"https://www.wikidata.org/wiki/Q1756067","display_name":"Power-system protection","level":4,"score":0.25110000371932983}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/tste.2026.3748040","doi":"https://doi.org/10.1109/tste.2026.3748040","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tste.2026.3748040","pdf_url":null,"source":{"id":"https://openalex.org/S201762130","display_name":"IEEE Transactions on Sustainable Energy","issn_l":"1949-3029","issn":["1949-3029","1949-3037"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-b","jufo-2","norway-1","poland-200","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Sustainable Energy","raw_type":"journal-article"},{"id":"pmh:oai:spiral.imperial.ac.uk:10044/1/149487","doi":null,"is_oa":true,"landing_page_url":"https://spiral.imperial.ac.uk/handle/10044/1/149487","pdf_url":"https://spiral.imperial.ac.uk/bitstreams/e6124bf3-d7e3-462d-905a-09a16d6b9e60/download","source":{"id":"https://openalex.org/S4306401396","display_name":"Spiral (Imperial College London)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I47508984","host_organization_name":"Imperial College London","host_organization_lineage":["https://openalex.org/I47508984"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"1","raw_type":"Journal Article"}],"best_oa_location":{"id":"pmh:oai:spiral.imperial.ac.uk:10044/1/149487","doi":null,"is_oa":true,"landing_page_url":"https://spiral.imperial.ac.uk/handle/10044/1/149487","pdf_url":"https://spiral.imperial.ac.uk/bitstreams/e6124bf3-d7e3-462d-905a-09a16d6b9e60/download","source":{"id":"https://openalex.org/S4306401396","display_name":"Spiral (Imperial College London)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I47508984","host_organization_name":"Imperial College London","host_organization_lineage":["https://openalex.org/I47508984"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"1","raw_type":"Journal Article"},"sustainable_development_goals":[{"score":0.9853000044822693,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"},{"score":0.6773999929428101,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W7224469071.pdf","grobid_xml":"https://content.openalex.org/works/W7224469071.grobid-xml"},"referenced_works_count":17,"referenced_works":["https://openalex.org/W2065466497","https://openalex.org/W2737237243","https://openalex.org/W2771664740","https://openalex.org/W2970129518","https://openalex.org/W3049732748","https://openalex.org/W3184525368","https://openalex.org/W3196075521","https://openalex.org/W3216142264","https://openalex.org/W4285248540","https://openalex.org/W4318954062","https://openalex.org/W4361766720","https://openalex.org/W4367280447","https://openalex.org/W4395470948","https://openalex.org/W4399310872","https://openalex.org/W4405718046","https://openalex.org/W4408017316","https://openalex.org/W7154493868"],"related_works":["https://openalex.org/W7202351210","https://openalex.org/W7168687528","https://openalex.org/W7206199263","https://openalex.org/W7166722066","https://openalex.org/W7220673092","https://openalex.org/W6943682167","https://openalex.org/W7213007917","https://openalex.org/W7165622911","https://openalex.org/W7222745406","https://openalex.org/W7213558846"],"abstract_inverted_index":{"Grid-following":[0],"converters":[1],"(GFLCs)":[2],"exhibit":[3],"an":[4,124],"inherent":[5,80],"delay":[6],"in":[7],"responding":[8],"to":[9,14,33,106],"post-fault":[10,22],"voltage":[11,100,111,126],"variations":[12],"due":[13],"measurement":[15],"and":[16,49,87,137,153],"control":[17,128,135],"mode":[18],"transition":[19],"latency.":[20],"Therefore,":[21],"temporary":[23],"overvoltage":[24],"(TOV)":[25],"may":[26],"arise,":[27],"making":[28],"renewable":[29],"power":[30],"plants":[31],"vulnerable":[32],"widespread":[34],"cascading":[35],"tripping.":[36],"To":[37,117],"address":[38],"this":[39,41,96],"issue,":[40],"paper":[42],"reveals":[43],"the":[44,51,58,68,74,79,83,109,119,133,138,154,160,163],"underlying":[45],"mechanism":[46,60],"of":[47,55,67,91,115,162],"TOV":[48,52,59,88,122],"enhances":[50],"suppression":[53,89],"capability":[54,86,114],"GFLCs.":[56,116],"First,":[57],"is":[61,93,104,130],"elucidated":[62],"through":[63],"singular":[64],"value":[65],"analysis":[66],"current":[69,84,134],"division":[70],"ratio":[71],"derived":[72],"from":[73],"equivalent":[75],"impedance":[76],"model.":[77],"Thereafter,":[78],"trade-off":[81],"between":[82],"tracking":[85],"performance":[90,136],"GFLCs":[92],"revealed.":[94],"On":[95],"basis,":[97],"a":[98],"transient":[99,110,146],"immunity":[101],"(TVI)":[102],"index":[103],"proposed":[105,164],"analytically":[107],"assess":[108],"overlimit":[112],"resilience":[113],"enhance":[118],"TVI":[120],"for":[121],"suppression,":[123],"adaptive":[125],"feedforward":[127],"scheme":[129],"proposed,":[131],"where":[132],"small-signal":[139],"stability":[140],"are":[141,151],"simultaneously":[142],"satisfied.":[143],"Finally,":[144],"electromagnetic":[145],"simulations":[147],"based":[148],"on":[149],"PSCAD":[150],"conducted,":[152],"results":[155],"under":[156],"various":[157],"scenarios":[158],"validate":[159],"effectiveness":[161],"method.":[165]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W7224469071","counts_by_year":[],"updated_date":"2026-11-22T12:46:00.618207","created_date":"2026-10-30T00:00:00"}
