{"id":"https://openalex.org/W7221550102","doi":"https://doi.org/10.3390/en19204800","title":"Hydrology-Aware Maintenance Scheduling for a Large Run-of-River Hydropower Plant Using FID-Guided Large Neighborhood Search","display_name":"Hydrology-Aware Maintenance Scheduling for a Large Run-of-River Hydropower Plant Using FID-Guided Large Neighborhood Search","publication_year":2026,"publication_date":"2026-10-11","ids":{"openalex":"https://openalex.org/W7221550102","doi":"https://doi.org/10.3390/en19204800"},"language":"en","primary_location":{"id":"doi:10.3390/en19204800","doi":"https://doi.org/10.3390/en19204800","is_oa":true,"landing_page_url":"https://doi.org/10.3390/en19204800","pdf_url":null,"source":{"id":"https://openalex.org/S198098182","display_name":"Energies","issn_l":"1996-1073","issn":["1996-1073"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","doaj","norway-1","poland-140","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energies","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://doi.org/10.3390/en19204800","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5087460745","display_name":"Vin\u00edcius Teixeira de Freitas da Concei\u00e7\u00e3o","orcid":"https://orcid.org/0009-0007-4349-8469","observed_orcids":["https://orcid.org/0009-0007-4349-8469"]},"institutions":[{"id":"https://openalex.org/I101100930","display_name":"Universidade Federal de Juiz de Fora","ror":"https://ror.org/04yqw9c44","country_code":"BR","type":"education","lineage":["https://openalex.org/I101100930"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Vin\u00edcius Teixeira de Freitas Concei\u00e7\u00e3o","raw_affiliation_strings":["Graduate Program in Electrical Engineering, Federal University of Juiz de Fora, Juiz de Fora 36036-900, MG, Brazil"],"raw_orcid":"https://orcid.org/0009-0007-4349-8469","affiliations":[{"raw_affiliation_string":"Graduate Program in Electrical Engineering, Federal University of Juiz de Fora, Juiz de Fora 36036-900, MG, Brazil","institution_ids":["https://openalex.org/I101100930"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5005293249","display_name":"V. F. Vidal","orcid":"https://orcid.org/0000-0002-2576-2760","observed_orcids":["https://orcid.org/0000-0002-2576-2760"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Vin\u00edcius Ferreira Vidal","raw_affiliation_strings":["IDEPE TECH, Juiz de Fora 36037-720, MG, Brazil"],"raw_orcid":"https://orcid.org/0000-0002-2576-2760","affiliations":[{"raw_affiliation_string":"IDEPE TECH, Juiz de Fora 36037-720, MG, Brazil","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5116044521","display_name":"Lucas Dias Hudson","orcid":"https://orcid.org/0009-0006-4941-4759","observed_orcids":["https://orcid.org/0009-0006-4941-4759"]},"institutions":[{"id":"https://openalex.org/I101100930","display_name":"Universidade Federal de Juiz de Fora","ror":"https://ror.org/04yqw9c44","country_code":"BR","type":"education","lineage":["https://openalex.org/I101100930"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Lucas Dias Hudson","raw_affiliation_strings":["Graduate Program in Electrical Engineering, Federal University of Juiz de Fora, Juiz de Fora 36036-900, MG, Brazil"],"raw_orcid":"https://orcid.org/0009-0006-4941-4759","affiliations":[{"raw_affiliation_string":"Graduate Program in Electrical Engineering, Federal University of Juiz de Fora, Juiz de Fora 36036-900, MG, Brazil","institution_ids":["https://openalex.org/I101100930"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5158458052","display_name":"Jo\u00e3o Alisson Mendes Reis","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Jo\u00e3o Alisson Mendes Reis","raw_affiliation_strings":["Engineering Department, Santo Ant\u00f4nio Energia, Porto Velho 76805-812, RO, Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Engineering Department, Santo Ant\u00f4nio Energia, Porto Velho 76805-812, RO, Brazil","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5158452212","display_name":"Pedro Paulo Dominguete Carvalho","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Pedro Paulo Dominguete Carvalho","raw_affiliation_strings":["Engineering Department, Santo Ant\u00f4nio Energia, Porto Velho 76805-812, RO, Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Engineering Department, Santo Ant\u00f4nio Energia, Porto Velho 76805-812, RO, Brazil","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5037165857","display_name":"Leonardo de Mello Hon\u00f3rio","orcid":"https://orcid.org/0000-0003-2735-4792","observed_orcids":["https://orcid.org/0000-0003-2735-4792"]},"institutions":[{"id":"https://openalex.org/I101100930","display_name":"Universidade Federal de Juiz de Fora","ror":"https://ror.org/04yqw9c44","country_code":"BR","type":"education","lineage":["https://openalex.org/I101100930"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Leonardo Mello Hon\u00f3rio","raw_affiliation_strings":["Graduate Program in Electrical Engineering, Federal University of Juiz de Fora, Juiz de Fora 36036-900, MG, Brazil"],"raw_orcid":"https://orcid.org/0000-0003-2735-4792","affiliations":[{"raw_affiliation_string":"Graduate Program in Electrical Engineering, Federal University of Juiz de Fora, Juiz de Fora 36036-900, MG, Brazil","institution_ids":["https://openalex.org/I101100930"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5064556236","display_name":"Andr\u00e9 Lu\u00eds Marques Marcato","orcid":"https://orcid.org/0000-0001-9171-3089","observed_orcids":["https://orcid.org/0000-0001-9171-3089"]},"institutions":[{"id":"https://openalex.org/I101100930","display_name":"Universidade Federal de Juiz de Fora","ror":"https://ror.org/04yqw9c44","country_code":"BR","type":"education","lineage":["https://openalex.org/I101100930"]}],"countries":["BR"],"is_corresponding":true,"raw_author_name":"Andr\u00e9 Lu\u00eds Marques Marcato","raw_affiliation_strings":["Graduate Program in Electrical Engineering, Federal University of Juiz de Fora, Juiz de Fora 36036-900, MG, Brazil"],"raw_orcid":"https://orcid.org/0000-0001-9171-3089","affiliations":[{"raw_affiliation_string":"Graduate Program in Electrical Engineering, Federal University of Juiz de Fora, Juiz de Fora 36036-900, MG, Brazil","institution_ids":["https://openalex.org/I101100930"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5064556236"],"corresponding_institution_ids":["https://openalex.org/I101100930"],"apc_list":{"value":2600,"currency":"CHF","value_usd":3137},"apc_paid":{"value":2600,"currency":"CHF","value_usd":3137},"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.76510896,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"19","issue":"20","first_page":"4800","last_page":"4800"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.5062999725341797,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.5062999725341797,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.48410001397132874,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10424","display_name":"Electric Power System Optimization","score":0.002099999925121665,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/maintenance-scheduling","display_name":"maintenance scheduling","score":0.8870000243186951},{"id":"https://openalex.org/keywords/run-of-river-hydropower","display_name":"run-of-river hydropower","score":0.9160000085830688},{"id":"https://openalex.org/keywords/large-neighborhood-search","display_name":"large neighborhood search","score":0.9890000224113464},{"id":"https://openalex.org/keywords/condition-based-maintenance","display_name":"condition-based maintenance","score":0.8569999933242798},{"id":"https://openalex.org/keywords/destroy-and-repair-operators","display_name":"destroy and repair operators","score":0.7609999775886536},{"id":"https://openalex.org/keywords/decision-support-framework","display_name":"decision support framework","score":0.47099998593330383}],"concepts":[{"id":"https://openalex.org/C40675005","wikidata":"https://www.wikidata.org/wiki/Q170196","display_name":"Hydropower","level":2,"score":0.7085000276565552},{"id":"https://openalex.org/C2780505938","wikidata":"https://www.wikidata.org/wiki/Q17093282","display_name":"Unavailability","level":2,"score":0.6371999979019165},{"id":"https://openalex.org/C206729178","wikidata":"https://www.wikidata.org/wiki/Q2271896","display_name":"Scheduling (production processes)","level":2,"score":0.57669997215271},{"id":"https://openalex.org/C180591934","wikidata":"https://www.wikidata.org/wiki/Q1253369","display_name":"Downtime","level":2,"score":0.5717999935150146},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.534600019454956},{"id":"https://openalex.org/C68387754","wikidata":"https://www.wikidata.org/wiki/Q7271585","display_name":"Schedule","level":2,"score":0.5138999819755554},{"id":"https://openalex.org/C85617194","wikidata":"https://www.wikidata.org/wiki/Q2072794","display_name":"Particle swarm optimization","level":2,"score":0.459199994802475},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.42289999127388},{"id":"https://openalex.org/C55416958","wikidata":"https://www.wikidata.org/wiki/Q6206757","display_name":"Job shop scheduling","level":3,"score":0.38530001044273376},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.3831000030040741},{"id":"https://openalex.org/C2778814095","wikidata":"https://www.wikidata.org/wiki/Q6736790","display_name":"Maintenance actions","level":2,"score":0.37709999084472656},{"id":"https://openalex.org/C42475967","wikidata":"https://www.wikidata.org/wiki/Q194292","display_name":"Operations research","level":1,"score":0.36980000138282776},{"id":"https://openalex.org/C8880873","wikidata":"https://www.wikidata.org/wiki/Q187787","display_name":"Genetic algorithm","level":2,"score":0.35910001397132874},{"id":"https://openalex.org/C12725497","wikidata":"https://www.wikidata.org/wiki/Q810247","display_name":"Baseline (sea)","level":2,"score":0.31679999828338623},{"id":"https://openalex.org/C23725684","wikidata":"https://www.wikidata.org/wiki/Q616377","display_name":"Maintenance engineering","level":2,"score":0.30469998717308044},{"id":"https://openalex.org/C109718341","wikidata":"https://www.wikidata.org/wiki/Q1385229","display_name":"Metaheuristic","level":2,"score":0.30379998683929443},{"id":"https://openalex.org/C181335050","wikidata":"https://www.wikidata.org/wiki/Q14915018","display_name":"Swarm behaviour","level":2,"score":0.30079999566078186},{"id":"https://openalex.org/C2777615720","wikidata":"https://www.wikidata.org/wiki/Q11888847","display_name":"Prioritization","level":2,"score":0.295199990272522},{"id":"https://openalex.org/C40128228","wikidata":"https://www.wikidata.org/wiki/Q460851","display_name":"Ant colony optimization algorithms","level":2,"score":0.29490000009536743},{"id":"https://openalex.org/C2778047078","wikidata":"https://www.wikidata.org/wiki/Q82299449","display_name":"Tardiness","level":4,"score":0.275299996137619},{"id":"https://openalex.org/C50601946","wikidata":"https://www.wikidata.org/wiki/Q962928","display_name":"Stockout","level":2,"score":0.2694000005722046},{"id":"https://openalex.org/C126980161","wikidata":"https://www.wikidata.org/wiki/Q863783","display_name":"Simulated annealing","level":2,"score":0.25440001487731934},{"id":"https://openalex.org/C194648553","wikidata":"https://www.wikidata.org/wiki/Q1364774","display_name":"Spare part","level":2,"score":0.25360000133514404},{"id":"https://openalex.org/C185798385","wikidata":"https://www.wikidata.org/wiki/Q1161707","display_name":"Benchmark (surveying)","level":2,"score":0.2506999969482422}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.3390/en19204800","doi":"https://doi.org/10.3390/en19204800","is_oa":true,"landing_page_url":"https://doi.org/10.3390/en19204800","pdf_url":null,"source":{"id":"https://openalex.org/S198098182","display_name":"Energies","issn_l":"1996-1073","issn":["1996-1073"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","doaj","norway-1","poland-140","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energies","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:54472d11e7d34ce28644a550f2e86258","doi":null,"is_oa":false,"landing_page_url":"https://doaj.org/article/54472d11e7d34ce28644a550f2e86258","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Energies, Vol 19, Iss 20, p 4800 (2026)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.3390/en19204800","doi":"https://doi.org/10.3390/en19204800","is_oa":true,"landing_page_url":"https://doi.org/10.3390/en19204800","pdf_url":null,"source":{"id":"https://openalex.org/S198098182","display_name":"Energies","issn_l":"1996-1073","issn":["1996-1073"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","doaj","norway-1","poland-140","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energies","raw_type":"journal-article"},"sustainable_development_goals":[{"score":1.0,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"},{"score":0.9853000044822693,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"},{"score":0.53329998254776,"display_name":"Clean water and sanitation","id":"https://metadata.un.org/sdg/6"}],"study_designs":[],"awards":[{"id":"https://openalex.org/G3572596660","display_name":null,"funder_award_id":"404859/2025-9","funder_id":"https://openalex.org/F4320322025","funder_display_name":"Conselho Nacional de Desenvolvimento Cient\u00edfico e Tecnol\u00f3gico"},{"id":"https://openalex.org/G7602580251","display_name":null,"funder_award_id":"307843/2023-8","funder_id":"https://openalex.org/F4320322025","funder_display_name":"Conselho Nacional de Desenvolvimento Cient\u00edfico e Tecnol\u00f3gico"},{"id":"https://openalex.org/G9001173788","display_name":null,"funder_award_id":"PD-06683-0225/2025","funder_id":"https://openalex.org/F4320324178","funder_display_name":"Ag\u00eancia Nacional de Energia El\u00e9trica"},{"id":"https://openalex.org/G9001175431","display_name":null,"funder_award_id":"TEC-APQ-02800/23","funder_id":"https://openalex.org/F4320322980","funder_display_name":"Funda\u00e7\u00e3o de Amparo \u00e0 Pesquisa do Estado de Minas Gerais"}],"funders":[{"id":"https://openalex.org/F4320322025","display_name":"Conselho Nacional de Desenvolvimento Cient\u00edfico e Tecnol\u00f3gico","ror":"https://ror.org/03swz6y49"},{"id":"https://openalex.org/F4320322980","display_name":"Funda\u00e7\u00e3o de Amparo \u00e0 Pesquisa do Estado de Minas Gerais","ror":"https://ror.org/00nc55f03"},{"id":"https://openalex.org/F4320324178","display_name":"Ag\u00eancia Nacional de Energia El\u00e9trica","ror":"https://ror.org/049sgh675"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":20,"referenced_works":["https://openalex.org/W1409921370","https://openalex.org/W1499047025","https://openalex.org/W1999940016","https://openalex.org/W2105002757","https://openalex.org/W2106631269","https://openalex.org/W2343865207","https://openalex.org/W2943241113","https://openalex.org/W3012534795","https://openalex.org/W3026752668","https://openalex.org/W3049025261","https://openalex.org/W3129486168","https://openalex.org/W3186061170","https://openalex.org/W3201100723","https://openalex.org/W4220982741","https://openalex.org/W4238780727","https://openalex.org/W4392481772","https://openalex.org/W4407265046","https://openalex.org/W4412979408","https://openalex.org/W7117363207","https://openalex.org/W7162255722"],"related_works":["https://openalex.org/W3129486168","https://openalex.org/W2006067272","https://openalex.org/W2803209311","https://openalex.org/W4413061475","https://openalex.org/W4416366982","https://openalex.org/W2072398668","https://openalex.org/W4379179866","https://openalex.org/W7172370459","https://openalex.org/W2392658766","https://openalex.org/W4386548659"],"abstract_inverted_index":{"Maintenance":[0],"scheduling":[1],"in":[2,34,168],"large":[3,169],"run-of-river":[4,170],"hydropower":[5,171],"plants":[6],"requires":[7],"balancing":[8],"maintenance":[9,40,46,68,166],"urgency,":[10],"asset":[11],"condition,":[12],"hydrological":[13,72],"opportunity,":[14],"and":[15,48,79,91,118,122],"operational":[16,103],"constraints.":[17,81],"This":[18],"study":[19],"proposes":[20],"an":[21],"integrated":[22],"decision-support":[23],"framework":[24],"for":[25,116,120],"the":[26,107,123,130,137,157],"Santo":[27],"Ant\u00f4nio":[28],"Hydropower":[29],"Plant,":[30],"a":[31,49,151],"50-unit":[32],"facility":[33],"Brazil.":[35],"The":[36,64,82],"methodology":[37],"combines":[38],"condition-informed":[39,161],"inputs,":[41],"multi-criteria":[42],"prioritization":[43],"of":[44,52,159],"generating-unit":[45],"needs,":[47],"Forced":[50],"Impact":[51],"Downtime":[53],"(FID)-guided":[54],"Large":[55],"Neighborhood":[56],"Search":[57],"(LNS)":[58],"algorithm":[59],"with":[60,87,114],"problem-specific":[61],"destroy-and-repair":[62],"operators.":[63],"optimization":[65,162],"reallocates":[66],"eligible":[67],"activities":[69],"from":[70,142],"high-impact":[71],"periods":[73],"while":[74],"enforcing":[75],"resource,":[76],"electrical,":[77],"hydraulic,":[78],"synchronization":[80],"proposed":[83],"approach":[84],"was":[85],"compared":[86,113],"Genetic":[88],"Algorithm":[89],"(GA)":[90],"Ant":[92],"Colony":[93],"Optimization":[94],"(ACO)":[95],"benchmarks":[96],"over":[97],"1000":[98],"independent":[99],"runs":[100],"using":[101],"real":[102],"data.":[104],"LNS":[105],"achieved":[106],"lowest":[108],"mean":[109],"fitness":[110],"value":[111],"(3587.68),":[112],"3939.45":[115],"ACO":[117],"3964.54":[119],"GA,":[121],"shortest":[124],"average":[125],"execution":[126],"time.":[127],"Relative":[128],"to":[129,144,150,163],"baseline":[131],"schedule":[132,139],"prepared":[133],"by":[134],"plant":[135],"specialists,":[136],"optimized":[138],"reduced":[140],"FID":[141],"452":[143],"302":[145],"equivalent":[146],"unavailability":[147],"hours,":[148],"corresponding":[149],"33.2%":[152],"reduction.":[153],"These":[154],"results":[155],"demonstrate":[156],"potential":[158],"hydrology-aware,":[160],"support":[164],"practical":[165],"planning":[167],"plants.":[172]},"counts_by_year":[],"updated_date":"2026-11-05T12:25:35.769452","created_date":"2026-10-13T00:00:00"}
