{"id":"https://openalex.org/W7220960403","doi":"https://doi.org/10.1038/s41598-026-72949-2","title":"Control of variable power low voltage ride-through and imbalance under abnormal voltage conditions in grid-tied photovoltaic inverters","display_name":"Control of variable power low voltage ride-through and imbalance under abnormal voltage conditions in grid-tied photovoltaic inverters","publication_year":2026,"publication_date":"2026-10-08","ids":{"openalex":"https://openalex.org/W7220960403","doi":"https://doi.org/10.1038/s41598-026-72949-2"},"language":"en","primary_location":{"id":"doi:10.1038/s41598-026-72949-2","doi":"https://doi.org/10.1038/s41598-026-72949-2","is_oa":true,"landing_page_url":"https://doi.org/10.1038/s41598-026-72949-2","pdf_url":"https://www.nature.com/articles/s41598-026-72949-2_reference.pdf","source":{"id":"https://openalex.org/S196734849","display_name":"Scientific Reports","issn_l":"2045-2322","issn":["2045-2322"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","doaj","dongbi-c","doyens","jufo-1","ki-jl-1","medline","norway-1","poland-140","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310319908","host_organization_name":"Nature Portfolio","host_organization_lineage":["https://openalex.org/P4310319908","https://openalex.org/P4310319965"],"host_organization_lineage_names":["Nature Portfolio","Springer Nature"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Scientific Reports","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://www.nature.com/articles/s41598-026-72949-2_reference.pdf","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5157934991","display_name":"Shujie Zhang","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210131919","display_name":"Xi'an University of Technology","ror":"https://ror.org/038avdt50","country_code":"CN","type":"education","lineage":["https://openalex.org/I4210131919"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Shujie Zhang","raw_affiliation_strings":["Xi\u2019an University of Technology, Xi\u2019an, 710054, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Xi\u2019an University of Technology, Xi\u2019an, 710054, China","institution_ids":["https://openalex.org/I4210131919"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100571984","display_name":"Haojie Zhu","orcid":"https://orcid.org/0009-0003-2083-6614","observed_orcids":["https://orcid.org/0009-0003-2083-6614"]},"institutions":[{"id":"https://openalex.org/I184843921","display_name":"Hebei University of Technology","ror":"https://ror.org/018hded08","country_code":"CN","type":"education","lineage":["https://openalex.org/I184843921"]},{"id":"https://openalex.org/I4405272076","display_name":"State Key Laboratory of Reliability and Intelligence of Electrical Equipment","ror":"https://ror.org/03h0f9b72","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4405272076"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Haojie Zhu","raw_affiliation_strings":["Key Laboratory of Electromagnetic Field and Electrical Apparatus Reliability of Hebei Province, Hebei University of Technology, Tianjin, 300401, China","School of Electronic and Information Engineering, Hebei University of Technology, Tianjin, 300401, China","State Key Laboratory of Reliability and Intelligence of Electrical Equipment, Hebei University of Technology, Tianjin, 300401, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Key Laboratory of Electromagnetic Field and Electrical Apparatus Reliability of Hebei Province, Hebei University of Technology, Tianjin, 300401, China","institution_ids":["https://openalex.org/I184843921"]},{"raw_affiliation_string":"School of Electronic and Information Engineering, Hebei University of Technology, Tianjin, 300401, China","institution_ids":["https://openalex.org/I184843921"]},{"raw_affiliation_string":"State Key Laboratory of Reliability and Intelligence of Electrical Equipment, Hebei University of Technology, Tianjin, 300401, China","institution_ids":["https://openalex.org/I184843921","https://openalex.org/I4405272076"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5157972632","display_name":"Erpeng Wang","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I184843921","display_name":"Hebei University of Technology","ror":"https://ror.org/018hded08","country_code":"CN","type":"education","lineage":["https://openalex.org/I184843921"]},{"id":"https://openalex.org/I4405272076","display_name":"State Key Laboratory of Reliability and Intelligence of Electrical Equipment","ror":"https://ror.org/03h0f9b72","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4405272076"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Erpeng Wang","raw_affiliation_strings":["Key Laboratory of Electromagnetic Field and Electrical Apparatus Reliability of Hebei Province, Hebei University of Technology, Tianjin, 300401, China","State Key Laboratory of Reliability and Intelligence of Electrical Equipment, Hebei University of Technology, Tianjin, 300401, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Key Laboratory of Electromagnetic Field and Electrical Apparatus Reliability of Hebei Province, Hebei University of Technology, Tianjin, 300401, China","institution_ids":["https://openalex.org/I184843921"]},{"raw_affiliation_string":"State Key Laboratory of Reliability and Intelligence of Electrical Equipment, Hebei University of Technology, Tianjin, 300401, China","institution_ids":["https://openalex.org/I184843921","https://openalex.org/I4405272076"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5157929282","display_name":"Haoran Xu","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I160674187","display_name":"China Three Gorges Corporation (China)","ror":"https://ror.org/02yqt2385","country_code":"CN","type":"company","lineage":["https://openalex.org/I160674187"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Haoran Xu","raw_affiliation_strings":["Three Gorges New Energy (Group) Co, Ltd. Construction Management Branch, Beijing, 101100, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Three Gorges New Energy (Group) Co, Ltd. Construction Management Branch, Beijing, 101100, China","institution_ids":["https://openalex.org/I160674187"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100957150","display_name":"Yao Lixiao","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210131919","display_name":"Xi'an University of Technology","ror":"https://ror.org/038avdt50","country_code":"CN","type":"education","lineage":["https://openalex.org/I4210131919"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Lixiao Yao","raw_affiliation_strings":["Xi\u2019an University of Technology, Xi\u2019an, 710054, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Xi\u2019an University of Technology, Xi\u2019an, 710054, China","institution_ids":["https://openalex.org/I4210131919"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5037386142","display_name":"Bing-Xiang Ji","orcid":"https://orcid.org/0000-0003-2349-8174","observed_orcids":["https://orcid.org/0000-0003-2349-8174"]},"institutions":[{"id":"https://openalex.org/I184843921","display_name":"Hebei University of Technology","ror":"https://ror.org/018hded08","country_code":"CN","type":"education","lineage":["https://openalex.org/I184843921"]},{"id":"https://openalex.org/I4405272076","display_name":"State Key Laboratory of Reliability and Intelligence of Electrical Equipment","ror":"https://ror.org/03h0f9b72","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4405272076"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Bingxiang Ji","raw_affiliation_strings":["Key Laboratory of Electromagnetic Field and Electrical Apparatus Reliability of Hebei Province, Hebei University of Technology, Tianjin, 300401, China","State Key Laboratory of Reliability and Intelligence of Electrical Equipment, Hebei University of Technology, Tianjin, 300401, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Key Laboratory of Electromagnetic Field and Electrical Apparatus Reliability of Hebei Province, Hebei University of Technology, Tianjin, 300401, China","institution_ids":["https://openalex.org/I184843921"]},{"raw_affiliation_string":"State Key Laboratory of Reliability and Intelligence of Electrical Equipment, Hebei University of Technology, Tianjin, 300401, China","institution_ids":["https://openalex.org/I184843921","https://openalex.org/I4405272076"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5037386142"],"corresponding_institution_ids":["https://openalex.org/I184843921","https://openalex.org/I4405272076"],"apc_list":{"value":2690,"currency":"USD","value_usd":2690},"apc_paid":{"value":2690,"currency":"USD","value_usd":2690},"fwci":0.0,"has_fulltext":true,"cited_by_count":0,"citation_normalized_percentile":{"value":0.67289041,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.6621000170707703,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.6621000170707703,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10468","display_name":"Photovoltaic System Optimization Techniques","score":0.2985999882221222,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.010400000028312206,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/grid-tied-photovoltaic-inverter","display_name":"grid-tied photovoltaic inverter","score":0.9279999732971191},{"id":"https://openalex.org/keywords/fault-ride-through","display_name":"fault ride-through","score":0.8529999852180481},{"id":"https://openalex.org/keywords/low-voltage-ride-through","display_name":"low-voltage ride-through","score":0.8420000076293945},{"id":"https://openalex.org/keywords/voltage-unbalance","display_name":"voltage unbalance","score":0.753000020980835},{"id":"https://openalex.org/keywords/power-balance","display_name":"power balance","score":0.4099999964237213}],"concepts":[{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.703000009059906},{"id":"https://openalex.org/C128624480","wikidata":"https://www.wikidata.org/wiki/Q1504817","display_name":"Low voltage","level":3,"score":0.6189000010490417},{"id":"https://openalex.org/C182365436","wikidata":"https://www.wikidata.org/wiki/Q50701","display_name":"Variable (mathematics)","level":2,"score":0.5774000287055969},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5192999839782715},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.5177000164985657},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4341000020503998},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.4269999861717224},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3513000011444092},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.3370000123977661},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.3206000030040741},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.3127000033855438},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.295199990272522},{"id":"https://openalex.org/C36139824","wikidata":"https://www.wikidata.org/wiki/Q1052007","display_name":"Maximum power point tracking","level":4,"score":0.2824000120162964},{"id":"https://openalex.org/C2985627981","wikidata":"https://www.wikidata.org/wiki/Q828827","display_name":"Power loss","level":3,"score":0.2605000138282776},{"id":"https://openalex.org/C56685638","wikidata":"https://www.wikidata.org/wiki/Q2300474","display_name":"Power control","level":3,"score":0.25920000672340393},{"id":"https://openalex.org/C3017773396","wikidata":"https://www.wikidata.org/wiki/Q6692774","display_name":"Ultra low power","level":4,"score":0.25540000200271606}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1038/s41598-026-72949-2","doi":"https://doi.org/10.1038/s41598-026-72949-2","is_oa":true,"landing_page_url":"https://doi.org/10.1038/s41598-026-72949-2","pdf_url":"https://www.nature.com/articles/s41598-026-72949-2_reference.pdf","source":{"id":"https://openalex.org/S196734849","display_name":"Scientific Reports","issn_l":"2045-2322","issn":["2045-2322"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","doaj","dongbi-c","doyens","jufo-1","ki-jl-1","medline","norway-1","poland-140","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310319908","host_organization_name":"Nature Portfolio","host_organization_lineage":["https://openalex.org/P4310319908","https://openalex.org/P4310319965"],"host_organization_lineage_names":["Nature Portfolio","Springer Nature"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Scientific Reports","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.1038/s41598-026-72949-2","doi":"https://doi.org/10.1038/s41598-026-72949-2","is_oa":true,"landing_page_url":"https://doi.org/10.1038/s41598-026-72949-2","pdf_url":"https://www.nature.com/articles/s41598-026-72949-2_reference.pdf","source":{"id":"https://openalex.org/S196734849","display_name":"Scientific Reports","issn_l":"2045-2322","issn":["2045-2322"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","doaj","dongbi-c","doyens","jufo-1","ki-jl-1","medline","norway-1","poland-140","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310319908","host_organization_name":"Nature Portfolio","host_organization_lineage":["https://openalex.org/P4310319908","https://openalex.org/P4310319965"],"host_organization_lineage_names":["Nature Portfolio","Springer Nature"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Scientific Reports","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":1.0},{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.9987000226974487}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W7220960403.pdf","grobid_xml":"https://content.openalex.org/works/W7220960403.grobid-xml"},"referenced_works_count":4,"referenced_works":["https://openalex.org/W4225810630","https://openalex.org/W4407566503","https://openalex.org/W4413003470","https://openalex.org/W4417093121"],"related_works":["https://openalex.org/W2367936747","https://openalex.org/W2781475601","https://openalex.org/W4414051434","https://openalex.org/W2376123404","https://openalex.org/W4410853402","https://openalex.org/W3088018182","https://openalex.org/W2567025357","https://openalex.org/W2179643014","https://openalex.org/W4312831302","https://openalex.org/W2736644353"],"abstract_inverted_index":{"Grid":[0],"connection":[1,16],"is":[2,73,108,146,166],"a":[3,104,134],"key":[4],"aspect":[5],"of":[6,10,79,100,181],"the":[7,61,67,70,77,101,112,138,149,154,170,177],"stable":[8,36],"operation":[9],"PV":[11,20,56,62,182],"systems,":[12],"and":[13,89,93,116,130,142,179],"traditional":[14],"grid":[15,40,90,185],"methods":[17],"rely":[18],"on":[19,97,169],"inverters.":[21,57],"Existing":[22],"power":[23,37,64,95,131,139,150,156],"electronic":[24],"hardware":[25],"still":[26],"faces":[27],"challenges":[28],"in":[29],"providing":[30],"sufficient":[31],"transient":[32],"support":[33],"while":[34],"maintaining":[35],"output":[38],"under":[39,159,184],"fault":[41,51,186],"conditions.":[42,162,187],"To":[43],"address":[44],"this,":[45],"this":[46],"paper":[47],"proposes":[48],"an":[49],"improved":[50],"ride-through":[52],"control":[53,114],"strategy":[54,174],"for":[55],"First,":[58],"by":[59],"adjusting":[60],"cell":[63],"tracking":[65],"trajectory,":[66],"voltage":[68,161],"at":[69],"battery":[71],"end":[72],"effectively":[74,175],"reduced,":[75],"minimizing":[76],"generation":[78],"excess":[80],"energy,":[81],"thereby":[82],"avoiding":[83],"Direct":[84],"Current":[85],"(DC)":[86],"bus":[87],"overvoltage":[88],"current":[91,105,119,125,128,143],"overcurrent,":[92],"achieving":[94,127],"balance":[96,129],"both":[98],"sides":[99],"inverter.":[102],"Secondly,":[103],"reference":[106,140,151,157],"generator":[107],"used,":[109],"combined":[110],"with":[111],"inverter":[113],"algorithm":[115],"positive\u2013negative":[117],"sequence":[118],"inner":[120],"loop":[121],"control,":[122],"to":[123],"calculate":[124],"commands,":[126],"stability.":[132],"Then,":[133],"quantitative":[135],"relationship":[136],"between":[137],"setpoint":[141],"peak":[144],"threshold":[145],"established":[147],"through":[148],"generator,":[152],"guiding":[153],"inverter\u2019s":[155],"setting":[158],"unbalanced":[160],"Finally,":[163],"simulation":[164],"verification":[165],"conducted":[167],"based":[168],"Rtlab":[171],"platform.":[172],"This":[173],"improves":[176],"stability":[178],"reliability":[180],"inverters":[183]},"counts_by_year":[],"updated_date":"2026-11-08T12:12:28.789561","created_date":"2026-10-09T00:00:00"}
