{"id":"https://openalex.org/W7220699080","doi":"https://doi.org/10.1109/icps67768.2026.11712966","title":"Investigation of Differential Protection Failure During an Internal Single-Line-to-Ground Fault in a Dyn-Connected Transformer","display_name":"Investigation of Differential Protection Failure During an Internal Single-Line-to-Ground Fault in a Dyn-Connected Transformer","alternate_titles":[],"publication_year":2026,"publication_date":"2026-05-01","ids":{"openalex":"https://openalex.org/W7220699080","doi":"https://doi.org/10.1109/icps67768.2026.11712966"},"language":"en","primary_location":{"id":"doi:10.1109/icps67768.2026.11712966","doi":"https://doi.org/10.1109/icps67768.2026.11712966","is_oa":true,"landing_page_url":"https://doi.org/10.1109/icps67768.2026.11712966","pdf_url":null,"source":{"id":"https://openalex.org/S4306418630","display_name":"IEEE/IAS Industrial and Commercial Power Systems Technical Conference","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2026 IEEE/IAS 62nd Industrial and Commercial Power Systems Technical Conference (I&amp;CPS)","raw_type":"proceedings-article"},"parent_works":[],"lineage":["https://openalex.org/W7220699080"],"child_works_count":0,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"hybrid","oa_url":"https://doi.org/10.1109/icps67768.2026.11712966","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5139900681","display_name":"Maxwell Kwesi Graham","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4387155091","display_name":"Ghana Standards Authority","ror":"https://ror.org/0084fbz83","country_code":"GH","type":"government","lineage":["https://openalex.org/I4387155091"]}],"countries":["GH"],"is_corresponding":false,"raw_author_name":"Maxwell Kwesi Graham","raw_affiliation_strings":["Electricity Company of Ghana, Accra, Ghana"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electricity Company of Ghana, Accra, Ghana","institution_ids":["https://openalex.org/I4387155091"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5092747933","display_name":"E. S. Kwaffo","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4387155091","display_name":"Ghana Standards Authority","ror":"https://ror.org/0084fbz83","country_code":"GH","type":"government","lineage":["https://openalex.org/I4387155091"]}],"countries":["GH"],"is_corresponding":false,"raw_author_name":"Emmanuel Sarfo Kwaffo","raw_affiliation_strings":["Electricity Company of Ghana, Accra, Ghana"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electricity Company of Ghana, Accra, Ghana","institution_ids":["https://openalex.org/I4387155091"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I4387155091"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/single-line-to-ground-fault","display_name":"single-phase grounding fault","score":0.9800000190734863},{"id":"https://openalex.org/keywords/relay-sensitivity","display_name":"relay sensitivity","score":0.7300000190734863},{"id":"https://openalex.org/keywords/protective-grounding","display_name":"protective earthing","score":0.7229999899864197},{"id":"https://openalex.org/keywords/touch-potential","display_name":"touch potential","score":0.44200000166893005}],"concepts":[{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.46209999918937683},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.4406999945640564},{"id":"https://openalex.org/C2986957705","wikidata":"https://www.wikidata.org/wiki/Q1756067","display_name":"Differential protection","level":4,"score":0.4320000112056732},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.33399999141693115},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3312999904155731},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.32269999384880066},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3041999936103821},{"id":"https://openalex.org/C38361682","wikidata":"https://www.wikidata.org/wiki/Q1756067","display_name":"Power-system protection","level":4,"score":0.2953000068664551},{"id":"https://openalex.org/C93226319","wikidata":"https://www.wikidata.org/wiki/Q193137","display_name":"Differential (mechanical device)","level":2,"score":0.28439998626708984},{"id":"https://openalex.org/C133770746","wikidata":"https://www.wikidata.org/wiki/Q856535","display_name":"Current transformer","level":4,"score":0.27250000834465027},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.26510000228881836},{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.258899986743927}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icps67768.2026.11712966","doi":"https://doi.org/10.1109/icps67768.2026.11712966","is_oa":true,"landing_page_url":"https://doi.org/10.1109/icps67768.2026.11712966","pdf_url":null,"source":{"id":"https://openalex.org/S4306418630","display_name":"IEEE/IAS Industrial and Commercial Power Systems Technical Conference","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2026 IEEE/IAS 62nd Industrial and Commercial Power Systems Technical Conference (I&amp;CPS)","raw_type":"proceedings-article"}],"best_oa_location":{"id":"doi:10.1109/icps67768.2026.11712966","doi":"https://doi.org/10.1109/icps67768.2026.11712966","is_oa":true,"landing_page_url":"https://doi.org/10.1109/icps67768.2026.11712966","pdf_url":null,"source":{"id":"https://openalex.org/S4306418630","display_name":"IEEE/IAS Industrial and Commercial Power Systems Technical Conference","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2026 IEEE/IAS 62nd Industrial and Commercial Power Systems Technical Conference (I&amp;CPS)","raw_type":"proceedings-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","score":0.4943999946117401,"display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":3,"referenced_works":["https://openalex.org/W1976500542","https://openalex.org/W2166205028","https://openalex.org/W4300611169"],"related_works":["https://openalex.org/W2377229449","https://openalex.org/W4410181717","https://openalex.org/W2248151856","https://openalex.org/W3016682220","https://openalex.org/W2368428366","https://openalex.org/W2388175482","https://openalex.org/W2595193439","https://openalex.org/W2101713628","https://openalex.org/W2140441178","https://openalex.org/W7164956226"],"abstract_inverted_index":{"This":[0,68],"paper":[1],"investigates":[2],"a":[3,8,12,20,51],"critical":[4],"protection":[5,88,107,135],"failure":[6],"at":[7],"primary":[9],"substation":[10],"where":[11],"single-line-to-ground":[13],"fault":[14,120],"within":[15],"the":[16,31,40,60,64,90,93,105,131],"differential":[17,34,115],"zone":[18],"of":[19,58,113,133],"20/26":[21],"MVA,":[22],"33/11":[23],"kV":[24],"Dyn1":[25],"transformer":[26,65],"was":[27,44,48],"not":[28],"detected":[29],"by":[30],"installed":[32],"electromechanical":[33,144],"relay.":[35],"The":[36,128],"fault,":[37],"initiated":[38],"on":[39],"transformer's":[41],"secondary":[42,61],"side,":[43],"sustained":[45],"because":[46],"current":[47],"supplied":[49],"through":[50],"zig-zag":[52],"grounding":[53,106],"transformer,":[54],"resulting":[55],"in":[56,104],"tripping":[57,124],"only":[59],"breaker":[62],"while":[63],"remained":[66],"energized.":[67],"condition":[69],"created":[70],"severe":[71],"safety":[72],"hazards,":[73],"including":[74,111],"dangerous":[75],"touch":[76],"potentials":[77],"that":[78],"nearly":[79],"led":[80],"to":[81],"operator":[82],"electrocution.":[83],"Through":[84],"system":[85],"modeling":[86],"and":[87,102,122,137],"analysis,":[89],"study":[91],"identifies":[92],"root":[94],"causes-limited":[95],"relay":[96],"sensitivity,":[97],"inappropriate":[98],"CT":[99],"ratio":[100],"selection,":[101],"deficiencies":[103],"philosophy.":[108],"Corrective":[109],"measures,":[110],"deployment":[112],"microprocessor-based":[114],"relays,":[116],"sensitive":[117],"residual":[118],"ground":[119],"elements,":[121],"revised":[123],"logic,":[125],"are":[126],"proposed.":[127],"findings":[129],"underscore":[130],"importance":[132],"modern":[134],"schemes":[136],"provide":[138],"lessons":[139],"for":[140],"utilities":[141],"managing":[142],"legacy":[143],"systems.":[145]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W7220699080","counts_by_year":[],"updated_date":"2026-11-17T12:49:18.490984","created_date":"2026-10-07T00:00:00"}