{"id":"https://openalex.org/W7219996663","doi":null,"title":"Energy Storage and Battery Management in Renewable Energy Systems: Advances in Power Conversion Architectures and Optimization Strategies","display_name":"Energy Storage and Battery Management in Renewable Energy Systems: Advances in Power Conversion Architectures and Optimization Strategies","alternate_titles":[],"publication_year":2025,"publication_date":"2025-10-21","ids":{"openalex":"https://openalex.org/W7219996663"},"language":"en","primary_location":{"id":"pmh:oai:oai.secitsociety.org:article/118","doi":null,"is_oa":true,"landing_page_url":"https://secitsociety.org/index.php/T-PERES/article/view/118","pdf_url":"https://secitsociety.org/index.php/T-PERES/article/download/118/234","source":{"id":"https://openalex.org/S7407078690","display_name":"Transactions on Power Electronics and Renewable Energy Systems","issn_l":"3107-5304","issn":["3107-5304"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"3107-5304","raw_type":"info:eu-repo/semantics/article"},"parent_works":[],"lineage":["https://openalex.org/W7219996663"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":true,"oa_status":"diamond","oa_url":"https://secitsociety.org/index.php/T-PERES/article/download/118/234","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5157132425","display_name":"Rasanjani Chandrakumar","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I195740183","display_name":"University of Moratuwa","ror":"https://ror.org/0491f5305","country_code":"LK","type":"education","lineage":["https://openalex.org/I195740183"]}],"countries":["LK"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Rasanjani Chandrakumar","raw_affiliation_strings":["Department of Electrical Engineering Faculty of Engineering,  University of Moratuwa Moratuwa, Sri Lanka"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering Faculty of Engineering,  University of Moratuwa Moratuwa, Sri Lanka","institution_ids":["https://openalex.org/I195740183"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5156863779","display_name":"P.K. Nestaris D. Gravino","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"P.K. Nestaris","raw_affiliation_strings":["Centro de Investigacion y Desarrollo de Tecnologias Aeronauticas (CITeA)  FuerzaAerea Argentina Las Higueras, Cordoba, Argentina"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Centro de Investigacion y Desarrollo de Tecnologias Aeronauticas (CITeA)  FuerzaAerea Argentina Las Higueras, Cordoba, Argentina","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.3408,"has_fulltext":true,"cited_by_count":2,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.4995796,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":87,"max":94},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10663","display_name":"Battery Modeling and Management","score":0.38989999890327454,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10663","display_name":"Battery Modeling and Management","score":0.38989999890327454,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.26930001378059387,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.2685999870300293,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/energy-storage-systems","display_name":"energy storage systems","score":0.9470000267028809},{"id":"https://openalex.org/keywords/battery-management-systems","display_name":"battery management systems","score":0.9760000109672546},{"id":"https://openalex.org/keywords/renewable-energy-integration","display_name":"renewable energy integration","score":0.8429999947547913},{"id":"https://openalex.org/keywords/bidirectional-dc-dc-converter","display_name":"bidirectional DC-DC converter","score":0.9700000286102295},{"id":"https://openalex.org/keywords/dual-active-bridge-converter","display_name":"dual active bridge converter","score":0.8849999904632568},{"id":"https://openalex.org/keywords/modular-multilevel-converter","display_name":"modular multilevel converter","score":0.9929999709129333},{"id":"https://openalex.org/keywords/state-of-charge-estimation","display_name":"state of charge estimation","score":0.9139999747276306},{"id":"https://openalex.org/keywords/extended-kalman-filter","display_name":"extended Kalman filter","score":0.8629999756813049},{"id":"https://openalex.org/keywords/active-balancing","display_name":"active balancing","score":0.7279999852180481},{"id":"https://openalex.org/keywords/model-predictive-control","display_name":"model predictive control","score":0.9200000166893005},{"id":"https://openalex.org/keywords/hybrid-energy-management","display_name":"hybrid energy management","score":0.7979999780654907},{"id":"https://openalex.org/keywords/round-trip-efficiency","display_name":"round-trip efficiency","score":0.8709999918937683},{"id":"https://openalex.org/keywords/battery-life","display_name":"battery life","score":0.9079999923706055},{"id":"https://openalex.org/keywords/fault-ride-through","display_name":"fault ride-through","score":0.9539999961853027},{"id":"https://openalex.org/keywords/solar-and-wind-energy","display_name":"solar and wind energy","score":0.6299999952316284}],"concepts":[{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.611299991607666},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5115000009536743},{"id":"https://openalex.org/C2778774385","wikidata":"https://www.wikidata.org/wiki/Q4437810","display_name":"Power management","level":3,"score":0.4925000071525574},{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.453000009059906},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.4399000108242035},{"id":"https://openalex.org/C101468663","wikidata":"https://www.wikidata.org/wiki/Q1620158","display_name":"Modular design","level":2,"score":0.43140000104904175},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.4284999966621399},{"id":"https://openalex.org/C86155754","wikidata":"https://www.wikidata.org/wiki/Q13636979","display_name":"Hybrid power","level":3,"score":0.415800005197525},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.40939998626708984},{"id":"https://openalex.org/C555008776","wikidata":"https://www.wikidata.org/wiki/Q267298","display_name":"Battery (electricity)","level":3,"score":0.38580000400543213},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.38440001010894775},{"id":"https://openalex.org/C70234604","wikidata":"https://www.wikidata.org/wiki/Q780813","display_name":"Galvanic isolation","level":4,"score":0.34209999442100525},{"id":"https://openalex.org/C50897621","wikidata":"https://www.wikidata.org/wiki/Q2665508","display_name":"Hybrid system","level":2,"score":0.32899999618530273},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.3264000117778778},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3100999891757965},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.30169999599456787},{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.30079999566078186},{"id":"https://openalex.org/C199845137","wikidata":"https://www.wikidata.org/wiki/Q145490","display_name":"Network topology","level":2,"score":0.29589998722076416},{"id":"https://openalex.org/C178911571","wikidata":"https://www.wikidata.org/wiki/Q593143","display_name":"Power electronics","level":3,"score":0.2937999963760376},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.2930000126361847},{"id":"https://openalex.org/C144822601","wikidata":"https://www.wikidata.org/wiki/Q11271324","display_name":"Energy transformation","level":2,"score":0.29010000824928284},{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.28839999437332153},{"id":"https://openalex.org/C2781260460","wikidata":"https://www.wikidata.org/wiki/Q6139999","display_name":"Energy management system","level":4,"score":0.2816999852657318},{"id":"https://openalex.org/C2778363213","wikidata":"https://www.wikidata.org/wiki/Q16938469","display_name":"Power management system","level":4,"score":0.28139999508857727},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.2809000015258789},{"id":"https://openalex.org/C2982719155","wikidata":"https://www.wikidata.org/wiki/Q25584060","display_name":"Energy source","level":3,"score":0.2802000045776367},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.27869999408721924},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.275299996137619},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.27000001072883606},{"id":"https://openalex.org/C194739806","wikidata":"https://www.wikidata.org/wiki/Q66221","display_name":"Computer data storage","level":2,"score":0.2669000029563904},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.263700008392334},{"id":"https://openalex.org/C145180747","wikidata":"https://www.wikidata.org/wiki/Q7236587","display_name":"Power optimizer","level":5,"score":0.25600001215934753},{"id":"https://openalex.org/C106945098","wikidata":"https://www.wikidata.org/wiki/Q2527701","display_name":"Internal resistance","level":4,"score":0.2529999911785126},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.2524000108242035}],"mesh":[],"locations_count":1,"locations":[{"id":"pmh:oai:oai.secitsociety.org:article/118","doi":null,"is_oa":true,"landing_page_url":"https://secitsociety.org/index.php/T-PERES/article/view/118","pdf_url":"https://secitsociety.org/index.php/T-PERES/article/download/118/234","source":{"id":"https://openalex.org/S7407078690","display_name":"Transactions on Power Electronics and Renewable Energy Systems","issn_l":"3107-5304","issn":["3107-5304"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"3107-5304","raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":{"id":"pmh:oai:oai.secitsociety.org:article/118","doi":null,"is_oa":true,"landing_page_url":"https://secitsociety.org/index.php/T-PERES/article/view/118","pdf_url":"https://secitsociety.org/index.php/T-PERES/article/download/118/234","source":{"id":"https://openalex.org/S7407078690","display_name":"Transactions on Power Electronics and Renewable Energy Systems","issn_l":"3107-5304","issn":["3107-5304"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"3107-5304","raw_type":"info:eu-repo/semantics/article"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":1.0},{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":0.7207000255584717},{"display_name":"Climate action","id":"https://metadata.un.org/sdg/13","score":0.685699999332428}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W7219996663.pdf","grobid_xml":"https://content.openalex.org/works/W7219996663.grobid-xml"},"referenced_works_count":7,"referenced_works":["https://openalex.org/W1990778263","https://openalex.org/W2085094058","https://openalex.org/W2105457945","https://openalex.org/W7219589444","https://openalex.org/W7219801981","https://openalex.org/W7219898897","https://openalex.org/W7220411561"],"related_works":["https://openalex.org/W7219958495","https://openalex.org/W2137367395","https://openalex.org/W7126050615","https://openalex.org/W7214987197","https://openalex.org/W7217853415","https://openalex.org/W7220156166","https://openalex.org/W4410295785","https://openalex.org/W4417209463","https://openalex.org/W7220093135"],"abstract_inverted_index":{"The":[0,63,145,295],"extensive":[1],"growth":[2],"of":[3,27,42,55,77,82,88,94,147,190,215,287,314,323],"interest":[4],"in":[5,24,39,57,80,154,253,301,325,338],"renewable":[6,89,315,340],"energy":[7,43,90,235,266,316],"sources":[8],"(RES),":[9],"more":[10],"specifically":[11],"solar":[12],"and":[13,32,60,70,86,110,120,124,139,157,165,219,233,247,282,285,304,335],"wind,":[14],"has":[15],"presented":[16],"a":[17,58],"major":[18],"challenge":[19],"to":[20,52,104,116,130,240,273,309],"modern":[21],"power":[22,67,122,170,302],"systems":[23,45],"the":[25,40,53,75,108,142,176,184,213,242,245,264,288,307,312,339],"form":[26,41],"grid":[28,135,291],"intermittency,":[29],"frequency":[30,289],"variability":[31],"decreasing":[33],"system":[34,180,185],"reliability.":[35],"Advanced":[36],"battery":[37,71,178,275,333],"technologies":[38,334],"storage":[44,248,342],"(ESS)":[46],"have":[47,306],"taken":[48],"centre-stage":[49],"as":[50,98,293],"pivotal":[51],"integration":[54,261],"renewables":[56],"stable":[59],"sustainable":[61],"manner.":[62],"work":[64,319],"explores":[65],"emerging":[66,331],"conversion":[68,303],"architecture":[69],"management":[72,179,211,236],"techniques":[73],"with":[74,330],"goal":[76],"optimizing":[78],"performance":[79,166,313],"terms":[81],"efficiency,":[83,160],"life":[84],"time":[85],"resilience":[87],"systems.":[91,317],"A":[92],"selection":[93],"converter":[95,102,127],"topologies,":[96,129],"such":[97],"bidirectional":[99,121],"DC":[100,101],"topologies":[103],"regulate":[105],"charge-discharge":[106],"on":[107,175,183],"circuit":[109],"dual":[111],"active":[112,220],"bridge":[113],"(DAB)":[114],"converters":[115,246],"provide":[117],"galvanic":[118],"isolation":[119],"transfer,":[123],"modular":[125],"multilevel":[126],"(MMC)":[128],"integrate":[131],"high-power":[132],"circuits":[133],"at":[134,141,152],"scale,":[136],"are":[137,238],"modeled":[138],"simulated":[140],"hardware":[143],"level.":[144],"functionality":[146],"these":[148],"architectures":[149],"is":[150,187,251,262],"benchmarked":[151],"switching-level":[153],"both":[155],"MATLAB/Simulink":[156],"PLECS,":[158],"prioritizing":[159],"designs":[161],"that":[162,167,256,258],"scale":[163],"well":[164],"meets":[168],"IEEE":[169],"quality":[171],"requirements.":[172],"An":[173],"evaluation":[174],"advanced":[177],"(BMS)":[181],"functions":[182],"level":[186],"conducted.":[188],"Examples":[189],"this":[191],"category":[192],"would":[193],"be":[194,269],"state-of-charge":[195],"SoC":[196],"estimation":[197],"by":[198,271,279],"applying":[199],"extended":[200],"Kalman":[201],"filtering,":[202],"state-of-health":[203],"SoH":[204],"modeling":[205],"including":[206,226],"internal":[207],"resistance":[208],"growth,":[209],"thermal":[210],"through":[212],"use":[214,322],"Foster":[216],"RC":[217],"networks":[218],"balancing":[221],"strategies.":[222],"Moreover,":[223],"optimization":[224],"strategies,":[225],"model":[227],"predictive":[228,327],"control":[229],"(MPC),":[230],"AI-based":[231],"forecasts,":[232],"hybrid":[234],"algorithms":[237],"used":[239],"enhance":[241,311],"interaction":[243],"between":[244],"units.":[249],"This":[250],"illustrated":[252],"case":[254],"studies":[255],"indicate":[257],"when":[259],"converter-BMS":[260],"optimized,":[263],"round-trip":[265],"losses":[267],"shall":[268],"reduced":[270],"up":[272],"15%,the":[274],"lifetime":[276],"utilization":[277],"improved":[278],"nearly":[280],"20%,":[281],"fault":[283],"ride-through":[284],"recovery":[286],"during":[290],"disturbances":[292],"well.":[294],"findings":[296],"demonstrate":[297],"how":[298],"combined":[299],"increases":[300],"BMS":[305],"ability":[308],"drastically":[310],"Future":[318],"will":[320],"involve":[321],"AI":[324],"building":[326],"BMS,":[328],"compatibility":[329],"solid-state":[332],"cybersecurity":[336],"models":[337],"microgrids":[341],"control.":[343]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W7219996663","counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":1}],"updated_date":"2026-11-22T12:46:00.618207","created_date":"2026-10-05T00:00:00"}
