{"id":"https://openalex.org/W7219102454","doi":"https://doi.org/10.82553/josc.2026.202605131239589","title":"A Trajectory Sensitivity-Based Stability Mapping for Optimal Grid Integration of Wind Farms into Low-Inertia Hybrid Power Systems","display_name":"A Trajectory Sensitivity-Based Stability Mapping for Optimal Grid Integration of Wind Farms into Low-Inertia Hybrid Power Systems","publication_year":2026,"publication_date":"2026-05-13","ids":{"openalex":"https://openalex.org/W7219102454","doi":"https://doi.org/10.82553/josc.2026.202605131239589"},"language":"en","primary_location":{"id":"doi:10.82553/josc.2026.202605131239589","doi":"https://doi.org/10.82553/josc.2026.202605131239589","is_oa":true,"landing_page_url":"https://doi.org/10.82553/josc.2026.202605131239589","pdf_url":null,"source":{"id":"https://openalex.org/S7407052608","display_name":"Journal of Optimization in Soft Computing (JOSC)  \u0628\u0647\u064a\u0646\u0647 \u0633\u0627\u0632\u064a \u062f\u0631 \u0645\u062d\u0627\u0633\u0628\u0627\u062a \u0646\u0631\u0645","issn_l":"3041-8534","issn":["3041-8534"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"JournalArticle"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["datacite"],"open_access":{"is_oa":true,"oa_status":"hybrid","oa_url":"https://doi.org/10.82553/josc.2026.202605131239589","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5027717988","display_name":"Alireza Solat","orcid":"https://orcid.org/0000-0001-8012-0851","observed_orcids":["https://orcid.org/0000-0001-8012-0851"]},"institutions":[{"id":"https://openalex.org/I4210162396","display_name":"Islamic Azad University Saveh","ror":"https://ror.org/053s4kp50","country_code":"IR","type":"education","lineage":["https://openalex.org/I110525433","https://openalex.org/I4210162396"]}],"countries":["IR"],"is_corresponding":true,"raw_author_name":"Solat, Alireza","raw_affiliation_strings":["Department of Electrical Engineering, College of Electrical Engineering and Computer, Saveh Branch, Islamic Azad University, Saveh, Iran"],"raw_orcid":"https://orcid.org/0000-0001-8012-0851","affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, College of Electrical Engineering and Computer, Saveh Branch, Islamic Azad University, Saveh, Iran","institution_ids":["https://openalex.org/I4210162396"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5027717988"],"corresponding_institution_ids":["https://openalex.org/I4210162396"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.6894999742507935,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.6894999742507935,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.2615000009536743,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.01979999989271164,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/trajectory-sensitivity-analysis","display_name":"trajectory sensitivity","score":0.9480000138282776},{"id":"https://openalex.org/keywords/transient-stability-assessment","display_name":"transient stability assessment","score":0.8500000238418579},{"id":"https://openalex.org/keywords/low-inertia-power-systems","display_name":"low-inertia power systems","score":0.9200000166893005},{"id":"https://openalex.org/keywords/hybrid-energy-systems","display_name":"hybrid energy systems","score":0.8870000243186951},{"id":"https://openalex.org/keywords/doubly-fed-induction-generator","display_name":"doubly fed induction generator","score":0.7860000133514404},{"id":"https://openalex.org/keywords/wind-power-integration","display_name":"wind power integration","score":0.8669999837875366},{"id":"https://openalex.org/keywords/inverter-based-resources","display_name":"inverter-based resources","score":0.8100000023841858},{"id":"https://openalex.org/keywords/critical-clearing-time","display_name":"critical clearing time","score":0.6140000224113464},{"id":"https://openalex.org/keywords/transient-energy-function","display_name":"transient energy function","score":0.9700000286102295},{"id":"https://openalex.org/keywords/wind-power-penetration","display_name":"wind power penetration","score":0.6790000200271606},{"id":"https://openalex.org/keywords/ieee-9-bus-system","display_name":"IEEE 9-bus system","score":0.75}],"concepts":[{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.6010000109672546},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.585099995136261},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5497999787330627},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.5493999719619751},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.5378999710083008},{"id":"https://openalex.org/C13662910","wikidata":"https://www.wikidata.org/wiki/Q193139","display_name":"Trajectory","level":2,"score":0.5235999822616577},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.4731000065803528},{"id":"https://openalex.org/C31395832","wikidata":"https://www.wikidata.org/wiki/Q1318674","display_name":"Testbed","level":2,"score":0.45719999074935913},{"id":"https://openalex.org/C86155754","wikidata":"https://www.wikidata.org/wiki/Q13636979","display_name":"Hybrid power","level":3,"score":0.43720000982284546},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.43470001220703125},{"id":"https://openalex.org/C50897621","wikidata":"https://www.wikidata.org/wiki/Q2665508","display_name":"Hybrid system","level":2,"score":0.4284999966621399},{"id":"https://openalex.org/C112972136","wikidata":"https://www.wikidata.org/wiki/Q7595718","display_name":"Stability (learning theory)","level":2,"score":0.40709999203681946},{"id":"https://openalex.org/C98716924","wikidata":"https://www.wikidata.org/wiki/Q752750","display_name":"Induction generator","level":3,"score":0.40610000491142273},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.40299999713897705},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3368000090122223},{"id":"https://openalex.org/C172205157","wikidata":"https://www.wikidata.org/wiki/Q1782962","display_name":"Model predictive control","level":3,"score":0.33219999074935913},{"id":"https://openalex.org/C38858127","wikidata":"https://www.wikidata.org/wiki/Q5441228","display_name":"Feed forward","level":2,"score":0.2996000051498413},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.2937999963760376},{"id":"https://openalex.org/C85761212","wikidata":"https://www.wikidata.org/wiki/Q1974593","display_name":"Transient response","level":2,"score":0.28999999165534973},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.2849000096321106},{"id":"https://openalex.org/C423512","wikidata":"https://www.wikidata.org/wiki/Q383973","display_name":"Electricity generation","level":3,"score":0.28290000557899475},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.2685000002384186},{"id":"https://openalex.org/C2780992000","wikidata":"https://www.wikidata.org/wiki/Q17016113","display_name":"Generator (circuit theory)","level":3,"score":0.25679999589920044}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.82553/josc.2026.202605131239589","doi":"https://doi.org/10.82553/josc.2026.202605131239589","is_oa":true,"landing_page_url":"https://doi.org/10.82553/josc.2026.202605131239589","pdf_url":null,"source":{"id":"https://openalex.org/S7407052608","display_name":"Journal of Optimization in Soft Computing (JOSC)  \u0628\u0647\u064a\u0646\u0647 \u0633\u0627\u0632\u064a \u062f\u0631 \u0645\u062d\u0627\u0633\u0628\u0627\u062a \u0646\u0631\u0645","issn_l":"3041-8534","issn":["3041-8534"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"JournalArticle"}],"best_oa_location":{"id":"doi:10.82553/josc.2026.202605131239589","doi":"https://doi.org/10.82553/josc.2026.202605131239589","is_oa":true,"landing_page_url":"https://doi.org/10.82553/josc.2026.202605131239589","pdf_url":null,"source":{"id":"https://openalex.org/S7407052608","display_name":"Journal of Optimization in Soft Computing (JOSC)  \u0628\u0647\u064a\u0646\u0647 \u0633\u0627\u0632\u064a \u062f\u0631 \u0645\u062d\u0627\u0633\u0628\u0627\u062a \u0646\u0631\u0645","issn_l":"3041-8534","issn":["3041-8534"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"JournalArticle"},"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","score":1.0,"id":"https://metadata.un.org/sdg/9"},{"display_name":"Affordable and clean energy","score":0.9853000044822693,"id":"https://metadata.un.org/sdg/7"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2546581860","https://openalex.org/W4390075010","https://openalex.org/W4225690485","https://openalex.org/W3011454606","https://openalex.org/W1970645050","https://openalex.org/W4408514879","https://openalex.org/W7082575738","https://openalex.org/W2904282194","https://openalex.org/W3125735272","https://openalex.org/W2161781667"],"abstract_inverted_index":{"The":[0,69,129],"rapid":[1,175],"transition":[2],"toward":[3],"inverter-based":[4],"resources,":[5],"particularly":[6],"Doubly-Fed":[7],"Induction":[8],"Generator":[9],"wind":[10,85,156,165,179],"farms,":[11],"necessitates":[12],"advanced":[13],"tools":[14],"for":[15,42,55,174],"transient":[16,60],"stability":[17,56,61,103],"assessment":[18,62,177],"in":[19,63,82,192],"low-inertia":[20,65],"grids.":[21],"Traditional":[22],"methods":[23],"like":[24],"Critical":[25],"Clearing":[26],"Time":[27],"(CCT)":[28],"and":[29,58,89,162,188],"Transient":[30],"Energy":[31],"Functions":[32],"(TEF)":[33],"are":[34,154],"either":[35],"computationally":[36,171],"prohibitive":[37],"or":[38],"lack":[39],"granular":[40],"insights":[41],"system":[43,83,127],"planning.":[44],"This":[45,167],"paper":[46],"presents":[47],"a":[48,97,101,134,141,170],"multi-parameter":[49,99],"trajectory":[50],"sensitivity":[51,74,117],"analysis":[52,114],"(TSA)":[53],"framework":[54,130],"mapping":[57],"fast":[59],"DFIG-integrated":[64],"hybrid":[66,142],"power":[67,194],"systems.":[68],"proposed":[70],"method":[71],"evaluates":[72],"the":[73,116,183],"of":[75,115,178],"state":[76],"trajectories":[77],"with":[78,144],"respect":[79],"to":[80,107,121,149],"variations":[81],"inertia,":[84],"penetration,":[86],"disturbance":[87],"parameters,":[88],"network":[90],"topology.":[91],"By":[92],"organizing":[93],"these":[94],"sensitivities":[95],"into":[96,140],"formal":[98],"TSA,":[100],"structured":[102],"map":[104],"is":[105,119,131],"constructed":[106],"identify":[108],"critical":[109],"operating":[110],"regions.":[111],"Furthermore,":[112],"correlation":[113],"responses":[118],"employed":[120],"reveal":[122],"dynamic":[123],"similarity":[124],"patterns":[125],"among":[126],"components.":[128],"implemented":[132],"on":[133],"modified":[135],"IEEE":[136],"9-bus":[137],"system,":[138],"transformed":[139],"testbed":[143],"DFIG":[145],"penetration":[146],"levels":[147],"up":[148],"40%.":[150],"Three":[151],"integration":[152,180],"archetypes":[153],"investigated:":[155],"capacity":[157],"addition,":[158],"synchronous":[159],"generator":[160],"retirement,":[161],"geographically":[163],"dispersed":[164],"siting.":[166],"research":[168],"provides":[169],"efficient":[172],"tool":[173],"operational":[176],"scenarios,":[181],"bridging":[182],"gap":[184],"between":[185],"offline":[186],"simulation":[187],"online":[189],"decision":[190],"support":[191],"renewable-rich":[193],"networks.":[195]},"counts_by_year":[],"updated_date":"2026-10-05T09:50:58.205359","created_date":"2026-10-04T00:00:00"}
