{"id":"https://openalex.org/W7217879681","doi":null,"title":"ADVANCED THREE-LEVEL CLLC RESONANT CONVERTER FOR HIGH-EFFICIENCY BIDIRECTIONAL EV CHARGING SYSTEMS","display_name":"ADVANCED THREE-LEVEL CLLC RESONANT CONVERTER FOR HIGH-EFFICIENCY BIDIRECTIONAL EV CHARGING SYSTEMS","alternate_titles":[],"publication_year":2026,"publication_date":"2026-08-26","ids":{"openalex":"https://openalex.org/W7217879681"},"language":"en","primary_location":{"id":"pmh:oai:ojs2.ijerst.org:article/4474","doi":null,"is_oa":true,"landing_page_url":"https://ijerst.org/index.php/ijerst/article/view/4474","pdf_url":"https://ijerst.org/index.php/ijerst/article/download/4474/4123","source":{"id":"https://openalex.org/S5406990484","display_name":"International Journal of Engineering Research and Science & Technology","issn_l":"2319-5991","issn":["2319-5991"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2319-5991","raw_type":"info:eu-repo/semantics/article"},"parent_works":[],"lineage":["https://openalex.org/W7217879681"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":true,"oa_status":"diamond","oa_url":"https://ijerst.org/index.php/ijerst/article/download/4474/4123","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5155361378","display_name":"CHIRRA RAKESH KUMAR B. YELLA REEDY","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":true,"contributor_roles":[],"raw_author_name":"B. YELLA REEDY, CHIRRA RAKESH KUMAR","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5155361378"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":true,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9901999831199646,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9901999831199646,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11249","display_name":"Wireless Power Transfer Systems","score":0.009100000374019146,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/bidirectional-resonant-converter","display_name":"bidirectional resonant converter","score":0.7459999918937683},{"id":"https://openalex.org/keywords/llc-resonant-converter","display_name":"LLC resonant converter","score":0.7950000166893005},{"id":"https://openalex.org/keywords/three-level-converter","display_name":"three-level converter","score":0.593999981880188},{"id":"https://openalex.org/keywords/parallel-transformers","display_name":"parallel transformers","score":0.8360000252723694},{"id":"https://openalex.org/keywords/electric-vehicle-charging","display_name":"electric vehicle charging","score":0.7689999938011169},{"id":"https://openalex.org/keywords/solar-photovoltaic-charging","display_name":"solar photovoltaic charging","score":0.7620000243186951},{"id":"https://openalex.org/keywords/battery-energy-storage","display_name":"battery energy storage","score":0.722000002861023},{"id":"https://openalex.org/keywords/zero-voltage-switching","display_name":"zero-voltage switching","score":0.9390000104904175},{"id":"https://openalex.org/keywords/zero-current-switching","display_name":"zero-current switching","score":1.0},{"id":"https://openalex.org/keywords/fuzzy-logic-control","display_name":"fuzzy logic control","score":0.8980000019073486},{"id":"https://openalex.org/keywords/bidirectional-power-flow","display_name":"bidirectional power flow","score":0.6790000200271606},{"id":"https://openalex.org/keywords/conversion-efficiency","display_name":"conversion efficiency","score":0.4569999873638153},{"id":"https://openalex.org/keywords/switching-losses","display_name":"switching losses","score":0.4090000092983246}],"concepts":[{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.602400004863739},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.5180000066757202},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.47620001435279846},{"id":"https://openalex.org/C2779502970","wikidata":"https://www.wikidata.org/wiki/Q30592852","display_name":"Resonant converter","level":4,"score":0.45669999718666077},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4487999975681305},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4474000036716461},{"id":"https://openalex.org/C2776422217","wikidata":"https://www.wikidata.org/wiki/Q13629441","display_name":"Electric vehicle","level":3,"score":0.4325999915599823},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.42590001225471497},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4034000039100647},{"id":"https://openalex.org/C150818752","wikidata":"https://www.wikidata.org/wiki/Q83804","display_name":"Buck converter","level":3,"score":0.38909998536109924},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3831000030040741},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.3452000021934509},{"id":"https://openalex.org/C76047896","wikidata":"https://www.wikidata.org/wiki/Q1786258","display_name":"Powertrain","level":3,"score":0.3422999978065491},{"id":"https://openalex.org/C555008776","wikidata":"https://www.wikidata.org/wiki/Q267298","display_name":"Battery (electricity)","level":3,"score":0.3352000117301941},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.32989999651908875},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.32760000228881836},{"id":"https://openalex.org/C204530211","wikidata":"https://www.wikidata.org/wiki/Q752823","display_name":"Thermal","level":2,"score":0.32600000500679016},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.32100000977516174},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.3131999969482422},{"id":"https://openalex.org/C78336795","wikidata":"https://www.wikidata.org/wiki/Q760134","display_name":"Boost converter","level":3,"score":0.3077000081539154},{"id":"https://openalex.org/C178911571","wikidata":"https://www.wikidata.org/wiki/Q593143","display_name":"Power electronics","level":3,"score":0.30720001459121704},{"id":"https://openalex.org/C144534570","wikidata":"https://www.wikidata.org/wiki/Q5325","display_name":"Inductor","level":3,"score":0.30550000071525574},{"id":"https://openalex.org/C58166","wikidata":"https://www.wikidata.org/wiki/Q224821","display_name":"Fuzzy logic","level":2,"score":0.29840001463890076},{"id":"https://openalex.org/C2777618391","wikidata":"https://www.wikidata.org/wiki/Q1483757","display_name":"Solar power","level":3,"score":0.2939999997615814},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.2865000069141388},{"id":"https://openalex.org/C195975749","wikidata":"https://www.wikidata.org/wiki/Q1475705","display_name":"Fuzzy control system","level":3,"score":0.2736000120639801},{"id":"https://openalex.org/C2778284599","wikidata":"https://www.wikidata.org/wiki/Q25340000","display_name":"Overheating (electricity)","level":2,"score":0.2734000086784363},{"id":"https://openalex.org/C2776636718","wikidata":"https://www.wikidata.org/wiki/Q1551796","display_name":"Charge controller","level":4,"score":0.2549999952316284},{"id":"https://openalex.org/C117127486","wikidata":"https://www.wikidata.org/wiki/Q11569191","display_name":"Thermoelectric generator","level":3,"score":0.2531999945640564},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.2531000077724457},{"id":"https://openalex.org/C88182573","wikidata":"https://www.wikidata.org/wiki/Q1139740","display_name":"High voltage","level":3,"score":0.2529999911785126},{"id":"https://openalex.org/C2776582896","wikidata":"https://www.wikidata.org/wiki/Q5368536","display_name":"State of charge","level":4,"score":0.2515999972820282}],"mesh":[],"locations_count":1,"locations":[{"id":"pmh:oai:ojs2.ijerst.org:article/4474","doi":null,"is_oa":true,"landing_page_url":"https://ijerst.org/index.php/ijerst/article/view/4474","pdf_url":"https://ijerst.org/index.php/ijerst/article/download/4474/4123","source":{"id":"https://openalex.org/S5406990484","display_name":"International Journal of Engineering Research and Science & Technology","issn_l":"2319-5991","issn":["2319-5991"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2319-5991","raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":{"id":"pmh:oai:ojs2.ijerst.org:article/4474","doi":null,"is_oa":true,"landing_page_url":"https://ijerst.org/index.php/ijerst/article/view/4474","pdf_url":"https://ijerst.org/index.php/ijerst/article/download/4474/4123","source":{"id":"https://openalex.org/S5406990484","display_name":"International Journal of Engineering Research and Science & Technology","issn_l":"2319-5991","issn":["2319-5991"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2319-5991","raw_type":"info:eu-repo/semantics/article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":1.0},{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":0.7207000255584717}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W7217879681.pdf","grobid_xml":"https://content.openalex.org/works/W7217879681.grobid-xml"},"referenced_works_count":14,"referenced_works":["https://openalex.org/W2249288637","https://openalex.org/W2282243216","https://openalex.org/W2543619047","https://openalex.org/W2789546709","https://openalex.org/W2805249620","https://openalex.org/W2882978001","https://openalex.org/W2948463843","https://openalex.org/W2979706008","https://openalex.org/W2984361232","https://openalex.org/W3002269601","https://openalex.org/W3026443319","https://openalex.org/W3047778266","https://openalex.org/W3162749997","https://openalex.org/W4285176654"],"related_works":["https://openalex.org/W7216836407","https://openalex.org/W7141207670","https://openalex.org/W4382053345","https://openalex.org/W4362647504","https://openalex.org/W4406003251","https://openalex.org/W4416924052","https://openalex.org/W4405974528","https://openalex.org/W2444679619","https://openalex.org/W2500600388","https://openalex.org/W3193100303"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"a":[3,68,82,153],"High-Efficiency":[4],"Bidirectional":[5],"LLC+C":[6,70],"Resonant":[7],"Converter":[8],"with":[9],"Parallel":[10],"Transformers":[11],"designed":[12],"for":[13,107,159],"solar-charged":[14],"electric":[15,162],"vehicle":[16,163],"(EV)":[17],"applications.":[18],"The":[19,65,124,145],"proposed":[20,125,150],"converter":[21],"topology":[22],"enables":[23],"bidirectional":[24,137],"power":[25],"flow":[26],"between":[27],"the":[28,33,38,52,149],"solar":[29,46,119],"photovoltaic":[30],"(PV)":[31],"source,":[32],"battery":[34],"storage":[35],"system,":[36],"and":[37,61,77,90,112,121,135,156,165],"EV":[39],"drivetrain,":[40],"ensuring":[41],"optimal":[42],"utilization":[43],"of":[44,67,110],"harvested":[45],"energy.":[47],"By":[48],"integrating":[49],"parallel-connected":[50],"transformers,":[51],"system":[53,97,126],"achieves":[54],"reduced":[55],"current":[56],"stress,":[57],"improved":[58],"thermal":[59],"performance,":[60,98],"enhanced":[62],"powerhandling":[63],"capability.":[64],"inclusion":[66],"hybrid":[69],"resonant":[71],"tank":[72],"allows":[73],"zerovoltage":[74],"switching":[75,79,92],"(ZVS)":[76],"zero-current":[78],"(ZCS)":[80],"over":[81],"wide":[83],"load":[84,122],"range,":[85],"significantly":[86],"improving":[87],"conversion":[88],"efficiency":[89],"minimizing":[91],"losses.":[93],"To":[94],"further":[95],"enhance":[96],"an":[99],"intelligent":[100],"fuzzy":[101],"logic":[102],"controller":[103],"(FLC)":[104],"is":[105,127,152],"employed":[106],"adaptive":[108],"regulation":[109],"voltage":[111],"current,":[113],"providing":[114],"robust":[115],"control":[116],"under":[117],"varying":[118],"irradiation":[120],"conditions.":[123],"validated":[128],"through":[129],"simulation":[130],"analysis,":[131],"demonstrating":[132],"superior":[133],"efficiency,":[134],"stable":[136],"operation":[138],"compared":[139],"to":[140],"conventional":[141],"single-transformer":[142],"LLC":[143],"converters.":[144],"results":[146],"confirm":[147],"that":[148],"design":[151],"reliable,":[154],"compact,":[155],"efficient":[157],"solution":[158],"next-generation":[160],"solarcharged":[161],"powertrains":[164],"renewable":[166],"energy-based":[167],"charging":[168],"infrastructures":[169]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W7217879681","counts_by_year":[],"updated_date":"2026-11-07T11:25:07.637180","created_date":"2026-10-03T00:00:00"}
